Loading...
HomeMy WebLinkAboutA15-0067_CO1224T-TR_1438292940.pdf SYSTEM �$ SENSOR° C01224T and C01224TR • • • mull Carbon Monoxide Detectors with RealTest°Technology *. . The System Sensor C01224T and C01224TR(round) ..#. Carbon Monoxide(CO)Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features With RealTest®technology,the CO gas sensing cell used in the CO1224T and CO1224TR CO detectors can be tested using a • RealTest®enables a functional test using canned CO CO gas agent,fully meeting the requirements of NFPA 720:2009. • Full compliance with UL 2075 Simply put the detector into RealTest mode,spray a small amount • A code-required trouble relay of CO into the detector per the installation instructions,and within seconds the detector will alarm,indicating successful gas entry.(See • Wiring supervision with SEMS terminals the reverse page or the user manual for complete instructions.) • A six-year end-of-life timer • 12/24 VDC When dangerous amounts of CO are detected,the CO1224T and A low current draw of 20 mA in standby and 40 mA in alarm CO1224TR detectors alert residents by sounding and flashing a • temp 4 signal alarm.With 24/7 central station monitoring, residents • Versatile mounting for wall and ceiling are guaranteed protection whether they are away from home, • Accurate and reliable electrochemical sensing technology sleeping,or already suffering from the effects of CO. • Optional CO-PLATE CO Detector Replacement Plate to upgrade The CO1224T and CO1224TR are designed for system operation. previously installed competitor detectors to the CO1224T These detectors are fully listed to UL 2075 and offer a code- required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.The CO1224T and CO1224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision.With a low current draw,these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels.As 12/24 VDC detectors,the CO1224T and CO1224TR will operate on most industry security and fire alarm control panels. Agency Listings U :5rry4 L • s... LISTED 115 E307195 E304075 5276-1653:0194 C01224T and C01224TR Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide(CO)detector shall be a system-connected System Sensor model number C01224T or C01224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct(surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual-color LED indication that blinks to indicate normal standby,alarm,or end-of-life.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million(ppm),as verified by a Nationally Recognized Test Laboratory. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size:C01224T Length:5.1 in,Width: 3.3 in,Height: 1.3 in C01224TR Diameter:6 in,Height: 1.3 in Approximate Weight C01224T:7 oz;C01224TR: 11 oz Operating Temperature Range 32°F to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single-gang back box;surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal(standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern RealTest®Feature: The System Sensor C01224T and C01224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. C Push and hold the Test/Hush button for Spray canned CO agent into Verify CO sensing at the two seconds to enter RealTest mode.The the detector. control panel.The detector will green LED will flash once every second automatically exit RealTest alarm to indicate RealTest mode has started. mode after about 20-60 seconds. NOTE:Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes(except in RealTest mode). IMF Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-Life Timer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel to indicate it is time to replace the detector.An electrochemical CO detector lifespan is about six years.The detector must be replaced by the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint(when necessary)of previously installed competitive carbon monoxide detectors that require replacement. Ordering Information CO PLATE Part No. Description C01224T 12/24 volt,4-wire system-monitored carbon monoxide detector with RealTest®Technology C01224TR 12/24 volt,4-wire system-monitored round carbon monoxide detector with RealTest®Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2012 System Sensor. Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SENSOR® for current product information,including the latest version of this data sheet www.systemsensor.com scoso0loo•4/12