HomeMy WebLinkAboutA15-0067_FA-0_1438967160.pdf lilei OF go,/ 40 itt -jig 01 Vail Fire&Emergent Services AHJ - Vail Fire Department 08/0715 BATTERY CALCULATIONS IFC 2 012 Occupancy Class - Residential multi- SYSTEM OUTPUTS LOCATION: 1st Level Mechanical family 907. 2. 11 . 2 Group R- 3, R- 3, R- 4. Single o r CONTROL PANEL HOURS OF SUPERVISION: 24 HOURS NOTIFICATION SAFETY CONTROLS PANEL: ADEMCO 128BPT MINUTES OF ALARM: 15 MINUTES multiple station smoke alarms shall be ANNUNCIATION Device Device Total installed regardless of occupant load at Total Alarm QTY PARTNUMBER Supervisory Alarm Supervisory o DESCRIPTION OF DEVICES Current Current Current Current all of the following Ioeations: 1 ADE-128BPT FACP 0.25000 0.33000 0.25000 0.33000 1 . On ceiling or wall outside each separate T y 1 ADE-4204 4 zone relay card 0.01500 0.16000 0.01500 0.16000 0 = 1 ESL-204 12/24 End of line power Supervision Module 0.00000 0.01400 0.00000 0.01400 sleeping area . °' o 1 ESL 405-05 ESL Reversal Relay 0.00000 0.03400 0.00000 0.03400 ti cl , Q ti .� Property: 3 ADE 4208U 8 Zone Expansion Module 0.02730 0.02730 0.08190 0.08190 2. In each room used for sleeping o b a - o o , t ' 756 Forest U . - s U H U' Q+ '/.' 1 ADE-6160 Annunciator 0.04000 0.15000 0.04000 0.15000 - - - o C f 7 11 SYS-C012241R Monitored Carbon Monoxide Detector 0.00200 0.04000 0.02200 0.44000 3. In each story within dwelling unit �� o p Road 15 ESL 541NCSXT Monitored Smoke Detector 0.00200 0.04000 0.03000 0.60000 VA I L FIRE INSTALLATION STANDARDS: o ' 28 ADE 4193 SN Addressable Modules 0.00150 0.00150 0.04200 0.04200 c3 c d a y fir, Y 1 SYS-MHW Interior Siren 0.00000 0.07500 0.00000 0.07500 1 . Smoke detection required in living rooms, ¢ ¢ ! P Q x - 5, c p ,, CO q o s Address: 1 SYS P2RK Exterior Horn Strobe 0.00000 0.21800 0.00000 0.21800 Q o d d U L o c ? s f •- 2 SYS-5603 135 degree fixed heat detector 0.00000 0.00000 0.00000 0.00000 family rooms and home theaters. o o 12 E'' COo E~ 756 Forest Rd 1 MAC-GD2A Combustible Gas Detector 0.04500 0.07000 0.04500 0.07000 F C . . o o 6 t, : :-: -=- ,,,o n . valla CO 8165'] a) �. �. - r TOTAL: 0.52590 2.21490 2. Boiler Mechanical rooms required heat detectors. W SUPERVISORY: E E E 2 0 0 0 3. Storage rooms not req d to have smoke detection . y 0 0 0 0 0 0 0 C 0 0 P Owner: SUB-TOTAL: 0.53 AMP 0 o 0 0 0 0 0 0 o COi, CO CO y ,y, _, o 24 HOURS OF SUPERVISORY: 24.00 HOURSsounder. ¢ ? w w w 4. Garages shall have a Smoke or Heat Detector x x x x x x SUB-TOTAL: 12.62 AMP HOURS ALARM: 5. Smokes/Heats shall be oriented to center of area. Carbon Monoxide Detector x x X x x x SUB-TOTAL: 2.21 AMP Ground Fault x x General Contractor: 15 MINUTES OF ALARM: 0.25 HOURS 6 . C 0 required in kitchens and indoor fireplaces. Scott S. Turnipseed Open Circuit x x x N 1143 Capitol St, Suite 211 SUB-TOTAL: 0.55 AMP HOURS 7. Crawl s aces do not require heats unless there is Notification Circuit Trouble x x x x p TOTALS: p P.O. Box 3388 TOTAL SUPERVISORY: 12.62 AMP HOURS mechanical equipment installed . Low Battery x x x x Eagle, Colorado 81631 TOTAL ALARM: 0.55 ANT HOURS AC Power Failure x X x x 970-328-3900 TOTAL: 13.18 AMP HOURS *SPARE OF 20°l0 2.64 AMP HOURS Telephone Line Fault-daily timer tet x MINIMUM BAl'IERY SIZE REQUIRED 15.81 AMP HOURS Remote Power Supply Trouble Condition Code Complience: BAl'lERIES SUPPLIED 2 x 8 anp 16.00 AMP HOURS Panel Silence Feature x x 2012 International Fire Code S ys t e m Code e f e r e n c e2010 NFPA-72 Nat. Fire Alarm Code Sprinkler Flow x x x x x 2011 NFPA-70 Nat. Electrical Code BATTERY CALCULATIONS: MAIN ALARM CONTROL PANEL Sprinkler Tamper x x x x Vail Fire Ammendments Levels: 3 Levels Bldg Height: 25'f Roof Height Occupancy Loads: EOLIR ( O x 3 Cox 4 THIRD FLOOR OAIM x 3 OAIM x 4 Occupancy Rating: R-2 Residential ANN - Zip x 9 c0 x 5 mi 35' SECOND FLOOR Structure: Type II/Non-Rated/Sprinkled OAIM x 9 OAIM x 5 OAIM Sq. Footage: -C Bell 1 "Aux Pwr 11806 SqFt± ANN 0135' CO �P x 3 Communication Type: Ademco OAIM x 2 0 FIST FLOOR DACT/POTS Lines AIM x 2 AIM x 6 1 28BPT Primary Power Location: /75WP FACP Main Elec Panel -Breaker \ FDC PANEL Designed and Installed by: SLC AIM OAIM OAIM SPRINKLER RISER SYSTEM / \ Phonelines (1) 120 VAC N Dedicated `" i Fi 12VDC 8 AH Batt Backup d Superior Alarm & Electronics 210 Edwards Vill. Blvd. #A108 Edwards, CO 81632 PH 970-926-8788 FX 970-926-8790 brad@superioralarmco.com SYMBOL DESCRIPTION DESCRIPTION CLASS STYLE TYPE FACP FIRE ALARM CONTROL PANEL OARM RELAY MODULE API ARM REMOTE STATION SIGNALING LINE CIRCUITS/POWER B 4 6 #18 AWG FPLR n SMOKE DETECTOR (PHOTOELECTRIC) ISI SYS# 6101-1759 New construction single family residence is being constructed in the Town NOTIFICATION ALARM CIRCUIT/POWER B Y 4 #22 AWG FPLR P I-N HORN/SOUNDER 135° HEAT DETECTOR FIXED/ROR (TEMP LISTED) HORN WITH STROBE of Vail . Residences will be fully s p r i n k l e r e d and a monitored fire INITIATING DEVICE CIRCUITS D 4 #18 AWG FPLR �15 (NUMBER INDICATES CANDELA) NATIONAL INSTITUTE FOR CERTIFICATION ANN ANNUNCIATOR 15 IN ENGINEERING TECHNOLOGIES alarm s s t e m will l l b e installed s t a l l e d with monitored carbon r b o n monoxide STROBE (NUMBER Fire Protection Engineering Technology y RS 485 (SBUS) 4 #18 AWG FPLR INDICATES CANDELA) Fire Alarm Systems detectors. USE PLENUM RATED WIRE IN ALL PLENUM SPACES f-�f WATER FLOW SWITCH / EOL END OF LINE RESISTOR 0 WIRE CHART f-{ -i VALVE WITH TAMPER SWITCH RE O k FIRE DEPARTMENT "KNOX" BOX '7/9�/S Scope of Work AIM ADDRESSABLE INPUT MODULE ICID MONITORED CARBON MONOXIDE DETECTOR George Sharer LEGEND NICET # 98481 Level III 0 Valid Thru 5/1/2017 ORIG.6/25/15 SCALE: 1/4"=1'0" REV. DATE NOTES: Approved for install. Please declutter plans in the future. Difficult to read in A • some areas. Pay attention to permit description. According to the A • description, this permit was for a panel replacement. A FINAL INSP. AS BUILTS: AHJ: Vail Fire Department Mike Vaughan Index. Permit #: PAGE NAME: Title/Bldg/Calcs/Map AHJ : Vail Fire Department - Flre Marshal Mlke Vaughan 970 . 479 . 2252FA-0 Cover Page A O SHEET 1 OF 4