HomeMy WebLinkAboutA15-0069_DATA SHEETS_1438981320.pdf GENTEX CORPORATION Photoelectric System 8000 / Smoke Detector 8003 Applications The Gentex 8000/8003 Series of photoelectric smoke detectors are SERIES designed for commercial, industrial, residential and institutional applications. The 8000/8003 is engineered to provide outstanding performance wherever reliable fire protection is required. The Gentex 8000/8003 Series provides an exclusive patented three • position test feature that simulates a 0.85% and a 3.5% actual smoke 111II0I condition, in full compliance with ANSI/UL 268 Standards for installation per NFPA 72 and the International Codes (IBC/IFC/IRC).The test feature • U IIIIII/ has the capability to let you know when maintenance is required. • A standard Form A dry relay contact for connection to the system initiating circuit and an auxiliary Form C dry relay contact is provided on all models for use as remote annunciation as a releasing device. Other options •••■••••••10e-- include reverse/local 90dBA solid-state piezo horns and 135°F (57.2°C) fixed temperature self-restoring integral or isolated thermals to meet your specific requirements. Easy Wash® - The 8003 Series provides the temporal 3 evacuation tone as a standard � On Site feature.When testing the 8003 Series it may take up to 16 seconds longer Maintenance to go in or out of alarm. Program Standard Features Product Listings • Available in 120VAC and 24VDC SIGNALING • Listed for releasing device service v�s "q"� • Horn frequency 3100 Hz (nominal) o` Ns►Ary=e • Temporal 3 evacuation sounding device (8003 Series) • Patented three position test LISTED I 1 • Nominal 2.5%sensitivity • ANSI/UL 268 Listed • Easy Wash°on-site maintenance washing program • CSFM:7272-0569:102 • Form A/Form C dry relay contacts • MEA#928-84-SA • Quick-disconnect wiring harness • MSFM Listing#1929 • 5-to-1 signal-to-noise ratio • Pulsing LED sensing chamber Product Compliance • Fully insect screened • NFPA 72 • Solid-state LED condition indicator • IBC/IFC/IRC • Mounting hardware adapts to standard junction boxes • Quality Management System is certified to: • Dust cover to prevent contamination during installation ISO 9001:2008 • Protective high air velocity gasket • 24 month warranty from date of purchase SAI 1� .l MEMBER ASSEMBLED IN THE USA 8000 (8240/8100) Series - Solid State Piezo Sounder (P Models only) Reverse/ Model Part Voltage Local 90dBA Integral 135°F Isolated 135°F Non-Latching Number Number Piezo Thermal Thermal Circuit"Y" 8240 908-1201-002 24VDC 8240Y 908-1207-002 24VDC • 8240T 908-1203-002 24VDC • 8240P 908-1202-002 24VDC • 8240PT 908-1205-002 24VDC • • 8240PTY 908-1209-002 24VDC • • • 8240PY 908-1208-002 24VDC • • 8240PH 908-1206-002 24VDC • • 8240PHY 908-1210-002 24VDC • • • 8100 908-1233-002 120VAC 8100Y 908-1239-002 120VAC • 8100T 908-1234-002 120VAC • 8100P 908-1236-002 120VAC • (local) 8100PY 908-1240-002 120VAC • (local) • 8003 (8243/8103) Series - Temporal 3 Piezo Sounder (P Models only) Reverse/ Model Part Integral 135°F Isolated 135°F Non-Latching Number Number Voltage Local 90dBA Thermal Thermal Circuit"Y" Piezo 8243P 908-1211-002 24VDC • 8243PT 9• 08-1212-002 24VDC • • 8243PTY 9• 08-1215-002 24VDC • • • 8243PY 908-1214-002 24VDC • • 8243PH 9• 08-1213-002 24VDC • • 8243PHY 9• 08-1216-002 24VDC • • • 8103P 908-1243-002 120VAC • (local) 8103PY 908-1246-002 120VAC • (local) • NOTES • The 8000/8003 Series are round units. • When testing 8103P/8243P Series, it may take up to 16 seconds longer for smoke alarm to go in or out of alarm mode. • It is recommended that 8000/8003 Series smoke detector be tested monthly. • Refer to Technical Bulletin 002 for Easy Wash°on site washing instructions • 8100P/8240P units produce a non-temporal audible alarm and are therefore not intended for locations where the desired action of the occupant(s) is evacuation. • 8103P/8243P units produce a temporal 3 audible alarm. Per NFPA 72, the American National Standard Audible Emergency Evacuation Signal as defined In ANSI S3.41, is required whenever the intended response is to evacuate the building. Wiring for Releasing Device Service Normally Closed Configuration Normally Open Configuration 120 VAC 120 VAC POWER SUPPLY POWER SUPPLY III WHITE WHITE l! BLACK WHITE BLACK NOTE:The blue wire YELLOW♦ must be capped off I WHITE • BLUE ORANGE ORANGE SSMOKE when wiring DEM CTOR OKE • DETECTOR for closed BLACK I BLACKcontacts. YELLOWBLUE WHITE -. WHITE D�� SMOKE ORANGE•.WHITE SMOKE • ORANGE• .WHITE DETECTOR DETECTOR BLACK BLACK BLACK -0 BLACK il- •• •• I IIID 71 RELEASE RELEASE RELEASE RELEASE Detector Wiring Diagram For "H" — Isolated Thermal — — NOTE:Supervision of power is necessary and is POSITIVE 3 POSITIVE 3 < accomplished by installing POWER NOTE: POWER an End of Line Relay As- NEGATIVE 12 IN NEGATIVE 12 / , IN sembly.The EOL Relay �� 120VAC C` Assembly contacts are POSITIVE 6 POSITIVE 6 closed when energized < POWER (8100 & 8103) / .411 and are wired in series NEGATIVE 15 OUT Hot(Black)Wire: POWER with the alarm loop.Power NEGATIVE 15< 1 OUT failure or a break in the VIOLET 10 Pin 3& Pin 6 power loop de-energizes / I the EOL Relay,causing VIOLET 13 Neutral VIOLET 10 / the relay contacts to open. / y ALARM White Wire: ` This results in a trouble VIO/BLK 1 T CONTACTS ( ) VIOLET 13/ signal at the control panel. VIO/BLK 4 1 Pin 12& Pin 15 ` ill 1 ALARM .44_1 VIO/BLK 1CONTACTS BLUE 7 24VDC 1 I T ��. (8240 & 8243) ORANGE 8 < ACCESSORY VIO/BLK 4 < 4 ALARM Positive YELLOW 9 < CONTACTS (Red)Wire: BLUE 7 \ 1-11 BROWN 2 � Pin 3& Pin 6 ORANGE 8 < AACCES LARMSORY BROWN 5 111I Negative , CONTACTS �J HEAT (Black)Wire: < YELLOW 9 , GRAY 11 ' SENSOR c`; I i Pin 12& Pin 15 GRAY 14 PLUG DETECTOR PLUG DETECTOR Supervised Wiring Diagrams SINGLE LOOP PANEL FUNCTIONAL DIAGRAM POWER [SHOWN l DOUBLE LOOP PANEL FUNCTIONAL DIAGRAM POWER [SHOWN l spvv ENERGIZED SPVY [ENERGIZED] FIRST LAST RELAY MODULE FIRST LAST RELAY MODULE UL LISTED SMOKE SMOKE UL LISTED SMOKE SMOKE CONTROL DETECTOR DETECTOR CONTROL DETECTOR DETECTOR PANEL RED IN OUT RED IN 0 T RED PANEL RED IN OUT RED IN O T RED POWER. � •a BLK lllI•i MM.! POWER 0 BLK O O BLK r' O O BLK a i VIOLWell lllM VIOL VIOL r I VIOL ALARM• • • _•—L•— ALARM 0 !0 'r 0--. o-�lto-� LOOP • VIO/BLK • • VIO/BLK • • VIO/BLK LOOP 0 VIO/BLK --0,i O r VIO/BLK 0 i O VIO/BLK END OF LINE• lJ BLU BLU • BLU ACCESSORY • BLU RESISTOR .ACCESSORY �� • ORN ALARM • ORN LOOP 0- 1 0 ORN ALARM 6 o- O^N 0 TEL CONTACTS • TEL RETURN 0 TEL CONTACTS O TEL DC P+BLK DC Nu] AC[WHTHNEUT] AC[WHTHNEUT] 8000 / 8003 SERIES Electrical Specifications Model Numbers 8240 8100 Operating Voltage Nominal: 24VDC 120VAC Range Min: 18VDC 110VAC Max: 30VDC 130VAC Frequency — 60HZ Current Consumption at Nominal Operating Voltage (Milliamperes): Standby 6mA 70mA Alarm 60mA 70mA Note: For"P"Option (Horn),Alarm Current Consumption is unchanged. Sensitivity 2.5% Nominal Alarm Contacts 1 Form A—N.O.(Resistive) 1 Amp at 24 VDC 0.6A at 120 VAC Auxiliary 1 Form C—N.O.(Resistive) 1 Amp at 24 VDC 0.6A at 120 VAC Temperature 40°- 100°F.(4.4°-38°C) Humidity 10%-93% Relative Humidity Size Diameter at base:5.75 in.(14.605 cm) Overall diameter: 6.25 in.(16.51 cm) Depth:2.625 in. Architect & Engineering Specifications The photoelectric smoke detector shall be a Gentex Model 8100/8103/8240/8243 or approved equal and shall operate on the photoelectric light scattering principle and shall be listed by Underwriter's Laboratories, Inc.,the State of California Fire Marshal and the Bureau of Standards and Appeals(NYC). The smoke detector shall contain an infrared LED light source and a light sensing photodiode.These components shall be positioned such that when smoke particles enter the sensing area, light from the LED reflects onto the photodiode.When the amount of light reflected onto the photodiode reaches a predetermined level,the detector shall latch into alarm. The smoke detector shall contain a test knob that,when in TEST 2 Position,scatters the detector's LED light source to the equivalent of a nominal .85%actual smoke condition,when in TEST 1 position the detector shall simulate an equivalent of a nominal 3.5%actual smoke condition.Test feature shall indicate when maintenance is required without the need of additional equipment. A magnetic switch closure or other switch closure,or smoke generating equipment which does not scatter the light beam or test sensitivity is not sufficient. The smoke detector shall be able to contain an optional internal 90dBA horn(at 10 feet)which emits an intermittent tone when the detector alarms.Also have the provision of reverse polarity operation.The horn shall have the capability of being self-restoring. The smoke detector shall be able to provide a self-restoring integral/isolated heat sensor set to alarm at 135°F(57.2°C)fixed temperature. The smoke detector shall be provided from the manufacturer with all internal wiring(power in, power out and alarm contacts have 2 wires, auxiliary relay contacts each have 1 wire) leading into a plug-in terminal socket for ease of field installation.Screws are not acceptable since they make service more difficult.The manufacturer shall further supply the field wiring harness with plug connector for connection to insulated wire connectors. The smoke detector shall mount to a 2"x 3"switch box or 4"octagon junction box using a standard bracket that does not have to be purchased separately.The smoke detector shall be listed for wall or ceiling mounting. 24 units per carton 32 pounds per carton Important Notice: 551-0039-03 G E N T E X These materials have been prepared by Gentex Corporation("Gentex")for informational pur- poses only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such.Gentex makes no representations and warranties,express or implied,that CORPORATION these materials are complete and accurate,up-to-date,or in compliance with all relevant local, state and federal laws,regulations and rules.The materials do not address all legal considera- tions as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and Fire Protection Products Group•www.gentex.com the application of such laws,regulations and rules to particular fact patterns.Each person's activ- ities can differently affect the obligations that exist under applicable laws,regulations or rules. 10985 Chicago Drive •Zeeland, Michigan 49464 Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be responsible for any 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. GAS DETECTION 6 MacurcoTM Carbon Monoxide Detector cm - El 11111111111 0 • + . •• i• CN EI . .. . .. .. . SIGNALING For use with alarm control panels LISTED Carbon Monoxide Detection The CM-E1 is a low voltage detector of Carbon Monoxide (CO). The CM—E1 is designed for connection to UL Listed Fire Alarm/Burglary Control Panels.Alarm control panels that work on 12 or 24 VDC can provide battery backup to the CM-E1 detectors. This carbon monoxide detector is designed to detect CO gas from ANY source of combustion. It is NOT designed to detect smoke, fire or any other gas. Features • Listed to UL standard 2075 for the Standard For Safety for Gas and Vapor Detector and Sensors • Tested to UL 2075 using UL 2034 Sensitivity limits for carbon monoxide gas • California State Fire Marshal Listed • Surface mounts to a wall using the supplied enclosure rear housing IPA ,i1/40'1"EctipN • Flush mounts in a 2 x 4 (1-1/2 inch deep minimum) single gang switch, Meagre() or handy electrical box 1972 2012 • Small, low profile, attractive unit in a white plastic case4, • Detector alarms at multiple levels of exposure to carbon monoxide 1. .o 4/I/ based on time weighted averages of the gas present A15<(‘G4.„ Years J 4. • Test & Reset switch conducts internal tests and actuates alarm relay ►�ivTiOty & • Highly linear electrochemical sensor -v^v' • N.O. or N.C. SPST Alarm Relay and N.C. SPST Trouble relay to connect to Alarm Control Panels • Buzzer: Produces repeating loud tone bursts during alarm, and chirps if sensor trouble is found Manufactured by Aerionics, Inc. Round Rock,TX—Phone: 1-877-367-7891 —Email: info@aerionicsinc.com —www.macurco.com CM-E1 Specifications @ • Voltage: 9-32 VDC • Current (normal / alarm): 15mA/ 35mA @ 9-32V 77,Lf, • Size: 3-1/8 X 5-1/8 X 1-1/2 inch (7.94 x 13.02 x 3.81 cm) •Alarm Relay: SPST, 100mA, 40VDC ) J. • Trouble Relay: SPST, 100mA, 40VDC r>'7- • Buzzer Rating: 85 dBA at 10 Feet - , • Shipping Weight: One pound J • Operating Temp. Range: 40°F (4.4°C) to 100°F (37.8°C) fr •Alarm Setting: Per UL 2034 • Color: White • Designed for use with a UL Listed Fire Alarm/Burglary Control Panel Installation With the CM-E1 faceplate mounted on the enclosure's rear-housing the unit can be surface mounted on a wall. A thin mid-plate enclosure component is also supplied with the CM-E1 to mount the CM-E1 on a 2 x 4 inch (5.08cm x 10.16 cm) switch box - single-gang or"handy", provided by the installer. Location There are two usual sources of CO - defective heat sources (furnaces or wood burning stoves) and automobiles running in adjoining garages. The CM-E1 can detect CO from these sources, as well as any other sources of CO. For best operation, mount a CM-E1 in the hallway near each bedroom or office area. In addition, another CM-E1 may be mounted just inside the door from the adjoining garage. Consider placing another detector in a bedroom or office that is adjacent to a furnace room. The detector may be installed on either a ceiling or a wall. If installed on a peaked, gabled, or sloped ceiling, it should be located about 3 feet (1 meter) from the highest point. The unit can be placed vertically or horizontally on a wall, so the information on the front of the CM-E1 can be read in a normal manner (not upside down). Do NOT mount the CM-E1 in a corner. Use the same spacing as for smoke detectors-- 30 foot (9 meters) centers, 900 sq. feet (83 sq. meters) per detector. TYPICAL CONNECTION OF TWO CM-E1 TO AN ALARM CONTROL PANEL TYPICAL COVERAGE 900 SQUARE FEET UL Listed Alarm Control Panel CM-E1 CM-E1 .1_ m N.O. initiating 0 Blue Blue o Circuit 0 Alarm J_ Alarm 70 Relay Z Yellow Relay Z Yellow Battery-backed 12 or 24 VDC Power Supply. Fuse N C Trouble Green • N.C.Trouble Green • or Current limit at 0.2 A for Relay GrayRelay Gray each CM E1 0Black(-) Black(-) GND 9 32VDDC Red(+) GND 9-32VDC Red(+) • Made in the U.S.A.with US and imported materials . ©Aerionics 2012.All rights reserved. IZIININICA Macurco is a trademark of Aerionics,Inc. Gas Detection Experts