HomeMy WebLinkAboutA15-0069_FA000_1440091620.pdf „,,,04* XI.) icao'a Vail Fire&Emergency Se vices 08/20/15 FIRE PLACE /i\ BELOW .L-1-/ (EXIST) / LIVING `, 1/4 �� Approved for install ' . /OPEN TO BELOW CD DINING I / LEGEND: 0 i ,_____ SYMBOL DEVICE MANUFACTURER/PART# Z COMMON STAIR COMMON STAIR Firelite MS9200 ON FACP CC Fire Alarm Panel (existing to remain) _ ----) O Gentex 8450 PSY (separate smoke & 0 ' UP , Smoke/Heat Detector heat sensor, with sounder base) BEDROOM J O I , < • DN N EMonitor Module Firelite M301 (existing) w CC) • M❑(NEW - CO DETECTORS) KITCHEN ENTRY J co 00 00 o] J E(EXISTING - SMOKE DETECTORS) ©0 Carbon Monoxide Detector Macurco CM-E1 D Lf,Carbon CM 0 O •71- _- • U BEDROOMJ ' eb loa = O ,o;m Z - OQoCHMMON COMMON A _ A BEDROOM g 1A PROJECT INFORMATION .0 -,,„:*_ ° , _ = ii_._ -_, NORTHWOODS CONDO E31 1C) 1 0 - 600 VAIL VALLEY DR. , VAIL, COLORADO -� JO ) FAMILY ROOM FIRE ALARM SYSTEM di 11 01 0 LINEN LAUD DRY BEDROOM AHJ: VAIL FIRE DEPARTMENT (1 i • -8- APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC roPi 41 • OCCUPANCY: GROUP R-2 0 0 = USE: CONDOMINIUMS 0 0 = FIRE ALARM WORK TO ACCOMMODATE CONDO REMODEL. WORK INCLUDES THE ; 0 REPLACEMENT OF EXISTING SMOKE DETECTORS AND ADDITION OF NEW DETECTORS �� ; / WO BEDROOM AS NEEDED. THE BUILDING HAS AN EXISTING FIRELITE MS9200 FACP. it F -ii ADDRESSABLE MONITOR MODULES ARE LOCATED AT EACH UNIT TO MONITOR THE BEDROOM `�( o HEAT DETECTOR PORTION OF THE NEW GENTEX DETECTORS. NEW DETECTORS WILL -2- BE INSTALLED THROUGHOUT THE REMODELED UNIT. THESE DEVICES PROVIDE A r ° SEPARATE SMOKE AND HEAT SENSOR (SMOKE FOR LOCAL ALARM - NOT CO SUPERVISED BY FACP; HEAT FOR GENERAL ALARM - SUPERVISED BY FACP). EACH DETECTOR HAS BUILT IN SOUNDER, WHICH WILL OPERATE IN TANDEM THROUGHOUT CO LOWER UNIT PLAN - UPPER UNIT PLAN THE UNIT ON A LOCAL ALARM. CARBON MONOXIDE DETECTORS WILL BE INSTALLED SCALE: 1/8' = 1'-0• SCALE: 1/8• = 1'-0• IN LOCATIONS SHOWN. THE BATTERY SIZE WILL NOT BE AFFECTED BY THIS 1- REMODEL. THE EXISTING SEQUENCE OF OPERATIONS WILL REMAIN AS IS. O o Q w ADDRESSABLE LOOP 24V POWER 24V POWER & FIRE PROTECTION ENGINEER: C6ADDRESSABLE LOOP O U W S HAN ER LIFE SAFETY 0 z Z au PO BOX 1073 © PRISCO, CO 80443 J U O El PHONE: 970-409-9082 Q 01— Cn FAX: 970-797-1898 - >w = MS9200 FACP © ® ® LM j W D EXISTING _IO 24V POWER & ~ ct D CO 24V POWER ADDRESSABLE LOOP Z 0 = W > If— 0 TYPICAL WIRING DIAGRAM 0 -I O co O > U o w = Q 0 CC o O co 0 �sFRrR by O Q "Zit �Ye Q � ` YC ``�] SHEET DESCRIPTION: }` :v FIRE ALARM PLAN i dig- 352333' Fit • (. T. fV,,,,IYL`R:, DRAWN BY: DATE: 4 '` ' f '.c7` DLS 8/6/15 eg`•••••"•ff SHEET#: FA-0.00