Loading...
HomeMy WebLinkAboutA15-0070_A15-0070 product sheets_1439413200.pdf ELS implex TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Sounder Base 4098-9794 for use with MEA (NYC)Acceptance* TrueAlarm Photoelectric and Heat Sensors Features Modular TrueAlarm sensor base with built-in electronic alarm sounder: • Piezoelectric sounder provides high output(88 dBA) with low current requirements(20 mA) I • For use with interchangeable TrueAlarm photoelectric __ irr_ or heat sensors(ordered separately) t �' • Operation is for ceiling or wall mounting Sounder operation details: TrueAlarm Photoelectric Sensor Mounted in Sounder Base 4098-9794 • Powered from 24 VDC or from a compatible Notification Appliance Circuit(NAC) TrueAlarm Analog Sensing Description • Synchronized via communications or by the NAC, if NAC powered** Sounder bases combine an audible notification appliance • Sounder can be manually activated from the control panel and a TrueAlarm analog sensor to provide: • Sensor and sounder operation is listed to UL Standard 268 • Sounder operation is also listed to UL Standard 464 Digital Communication of Analog Sensing. as an audible notification appliance Sensors provide an analog measurement that is digitally communicated to the control panel where it is analyzed TrueAlarm analog sensing operation: and an average value is determined and stored.An alarm • Analog sensor information is digitally communicated or other abnormal condition is determined by comparing to the control panel via ZDNet or MAPNET II the sensor's present value against its average value. two-wire communications • Sensor information is processed by the control panel Intelligent Data Evaluation.Monitoring each sensor's to determine sensor status average value provides a software filtering averaging For use with the following Simplex®products: process that compensates for environmental factors(dust, 4007E5,4010,4010ES,4100ES,and 4100U Series dirt,etc.)and component aging,providing an accurate • control panels;and 4008 Series control panels with reference for evaluating new activity.The result is a reduced feature set(refer to data sheet S4008-0001 for significant reduction in the probability of false or details) nuisance alarms caused by shifts in sensitivity,either up • 4020,4100,and 4120 Series control panels,and or down. Universal Transponders equipped for MAPNET II Control Panel Selection.Peak activity per sensor is operation stored to assist in evaluating specific locations.The alarm General features: set point for each TrueAlarm sensor is determined at the • Louvered smoke sensor design enhances smoke control panel,selectable as more or less sensitive as the capture by directing flow to chamber;entrance areas individual application requires. are minimally visible when ceiling mounted Timed/Multi-Stage Selection.Alarm set points can be • Designed for EMI compatibility programmed for timed automatic sensitivity selection • Magnetic test feature is provided (such as more sensitive at night,less sensitive during • Optional accessories include remote LED alarm day).Control panel programming can also provide indicator and output relays multi-stage operation per sensor.For example,a 0.2% Additional base reference: level may cause a warning to prompt investigation while a • For standard bases,refer to data sheet 54098.0019 2.5%level may initiate an alarm. • For isolator bases,refer to data sheet S4098-0025 Sensor Alarm and Trouble LED Indication.Each + For photo/heat sensors,refer to data sheet S4098-0024 sensor base's LED pulses to indicate communications (single address)and S4098-0033(dual address) with the panel.If the control panel determines that a sensor is in alarm,or that it is dirty or has some other type * This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section of trouble,the details are annunciated at the control panel 13144.1 of the California Health and Safety Code.See CSFM Listings 7300-0026:217 and and that sensor base's LED will be turned on steadily. 7271-0026:231 for allowable values and/or conditions concerning material presented in this document Accepted for use—City of New York Department of Buildings—MEA3S-93E.Additional During a system alarm,the control panel will control the listings may be applicable,contact your local Simplex product supplier for the latest status.Listings LEDs such that an LED indicating a trouble will return to and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection pulsing to helpIdents the alarmed sensors. Products. P g identify ""Total quantity of sounder bases available for coding on the same communications channel may vary with panel application and availability of NAC power.Refer to specific control panel requirements. S4098-0028-11 1/2015 Additional Sounder Base Features Mountin• Reference Base mounted address selection allows the address to remain with its programmed location when the sensor is removed for service or type change.Access is from the Electrical Box Requirements:(boxes are by others) front under the removable sensor. Without relay:4"octagonal or 4"square,1-1/2"deep;single gang, Automatic sensor type identification provides 2"deep default sensitivitywhen substitutingsensor types. Wth relay_4"octagonal or 4"square, 1-112"deep,with 1-112" extension ring Different sensor types can be easily interchanged to meet 4^(102 mm)Square Box 4"(102 mm)Octagonal Box specific location requirements.This feature also allows Surface mount reference intentional sensor substitution during building r t-r A construction. When conditions are temporarily dusty, .---. . __ 1-1/2"(38 mm) _ ` ` instead of covering the smoke sensors(causing them to be minimum box depth_,' disabled),heat sensors may be installed without reprogramming the control panel. r ' 4 integral red LED indicates ower on bypulsing,or Flush mount reference,mount even with final 13 P P g� surface,or with up to 114"(6.4 mm)maximum recess alarm or trouble when steady on.The exact status is annunciated at the fire alarm control panel. r 1 C�I Optional 4098-9822 Relay Fire alarm control panel provides: i �p� \ (Mounts in base electrical box Note:Single gang and requires additional • Peak value logging allowing accurate analysis of each adapter plate(RACO volume,see notes below) sensor for individual sensitivity selection No.767 or equal)is • Sensitivity monitoring satisfying NFPA 72 sensitivity required when using ) ` square box(by otherss) (., testing requirements;automatic individual sensor Relay size: ', I,,I,o 2-112"X 1-112"X 1" `I, E,1. calibration check verifies sensor integrity _r2'_ (64 mm X 38 mm X • Automatic environmental compensation,multi-stage 25.4 mm),3.75 cubic inches alarm operation,and display of sensitivity directly in percentper foot 6-318"Dia. x 114"thick 4098-9832 Adapter Plate,required for mounting • Ability to display and print detailed sensor to surface mounted boxes(mounts inverted) information in plain English language 1 Accessories Lo 6-7/16"(164 mm) 1.1 ,---j 1-118" 4098-9822, LED Annunciation Relay activates when (29 mm ----------- -------- base LED is on steady,indicating a local alarm or trouble. r Contacts are DPDT,rated 2 A @ 30 VDC; 1/2 A @ 120 VAC for transient suppressed loads(requires external LED status Sound output louvers 24 VDC coil power). inndd icator extend from front to side C 2098-9808, Remote red LED Alarm Indicator mounts on a single gang box to provide status indications where theiri � �'1; ffiff sensor location may not be readily visible. ��.ti�1�---- 7(Photoelectric sensor shown for reference) NOTES: 1. Review actual wire size,wire count,box type,and whether 4098-9822 relay is used before determining box size_ ALARM2. Mounting to flush mounted box also fits single gang handy box, 4 2-118"(51 mm)deep if wiring allows-(Not applicable if 4098-9822 relay is used.) 3. For surface mounted boxes,use 4"square box with single gang adapter plate(RACO No.787 or equal,by others)or 4"octagonal f5Iplex box,both require 4098-9832 Adapter Plate_ 4. When 4098-9822 relay is used,mount relay in electrical box and use 1-112"extension ring(by others)on 4"square or octagonal box of 1-1/2"or 2-1/8"depth as required. 5.Refer to Installation Instructions 574-707 for additional information. 2098-9808 Remote LED Alarm Indicator 2 54098-0028-11 1/2015 TrueAlarm Analo• Sensor Features 4098-9733 Heat Sensor Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate compensated,fixed temperature sensing,selectable with Electronics are EM1lRFI shielded or without rate-of-rise temperature sensing.Due to its Heat sensors: small thermal mass,the sensor accurately and quickly • Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire sensing with or without rate-of-rise operation alarm control panel. • Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the Fixed Temp. UL 8 ULC FM Spacing,Either Fixed control panel for either 15°F(8.3°C)or 20°F(11.1'C) Setting Spacing Temperature Setting per minute.Fixed temperature sensing is independent of 135"F 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fixed rate-of-rise sensing and programmable to operate at (57.2°C) (18.3 m) temperature only;RT1=Quick 135°F(57.2°C)or 155°F(68°C).In a slow developing 50 ft x 50 ft(15.2 m)for fixed fire,the temperature may not increase rapidly enough to 155°F 40 ft x 40 ft temperature with either rate-of-rise (68'C) (12.2 m) selection;RTi=Ultra Fast operate the rate-of-rise feature.However,an alarm will be initiated when the temperature reaches its rated fixed Smoke Sensors: temperature setting. • Photoelectric technology sensing TrueAlarm heat sensors can be programmed as a utility • 360°smoke entry for optimum response device to monitor for temperature extremes in the range • Built-in insect screens from 32°F to 155°F(0°C to 68°C).This feature can provide freeze warnings or alert to HVAC system problems.Refer to specific panels for availability. 4098-9714 Photoelectric Sensor 6-7/16"(164 mm) rl TrueAlarm photoelectric sensors use a stable,pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing.Seven levels of sensitivity are available 2-9116" for each individual sensor,ranging from 0.2%to 3.7%per (65 mm) foot of smoke obscuration. Sensitivities of 0.2%,0.5%, 111II�'IIII.I. and 1%are for special applications in clean areas. IlI. Standard sensitivities are 1.5%,2.0%,2.5%,3.0%,and 3.7%.Application type and sensitivity are selected and then monitored at the fire alarm control panel.* 4098-9733 Heat Sensor with 4098-9794 Sounder Base The sensor head design provides 360°smoke entry for optimum smoke response.Due to its photoelectric WARNING: In most fires,hazardous levels of smoke operation,air velocity is not normally a factor,except for and toxic gas can build up before a heat detection impact on area smoke flow. device would initiate an alarm.In cases where Life Safety is a factor,the use of smoke detection is highly r 6-7116"(164 mm) -a recommended. Application Reference Sensor locations should be determined after careful 2-5/16" consideration of the physical layout and contents of the (38 mm) 11•111111•11•111MIN1111111111111area to be protected.Referto NFPA 72,the National Fire Ilt \�� �� Alarm and Signaling Code.On smooth ceilings,smoke sensor spacing of 30 ft(9.1 m)may be used as a guide. For detailed application information,refer to 4098 4098-9714 Photoelectric Sensor with Sounder Base Detectors,Sensors, and Bases Application Manual,Part Number 574-709.* *For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0028-11 112015 TrueAlarm Analo• Sensin• Product Selection Chart TrueAlarm Sounder Base* Model Description Compatibility Mounting Requirements Sounder Base with connections Sensors:4098-9714 and 4098-9733 4098-9794 for Remote LED Alarm Indicator Refer to page 2,mounting reference or Unsupervised Relay Options:2098-9808 remote LED alarm indicator or 4098-9822 relay TrueAlarm Sensors (ordered separately) Model Description Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Refer to page 2,mounting reference 4095-9733 Heat Sensor Sounder Base Accessories (ordered separately if required) Model Description Mounting Requirements 4098-9832 Adapter Plate, required for surface mounted 4"electrical boxes Refer to page 2,mounting reference 2098-9808 Remote red LED Alarm Indicator on single gang Single gang box,1-1/2"minimum depth Choose one if stainless steel plate required Relay,tracks base LED status(unsupervised,to be Mounts in base electrical box(requires 1-112" 4098-9822 mounted only in base electrical box) extension on 4"square or octagonal box) Refer to data sheet 54098-0019 for other compatible bases.Refer to Installation Instructions 574-707 and Application Manual 574-709 for additional information. S•ecifications General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications,auto-selected, 1 address per base Communications and Sounder Power Connections Screw terminals for in/out wiring,18 to 14 AWG(0.82 mm2 to 2.08 mm2) Current 1 mA typical supplied from communications,no impact to alarm current Remote LED Alarm Indicator LED Connections Color coded wire leads,18 AWG(0.82 mm2) UL Listed Temperature Range 32°F to 100°F(0°C to 38°C) Operating With 4098-9733 32°F to 122°F(0°C to 50°C) Temperature Range With 4098-9714 15°F to 122°F(-9°C to 50°C) Storage Temperature Range 0°F to 140°F(-18°C to 60°C) Humidity Range 10 to 95%RH Smoke Sensor 4098-9714, Air velocity is 0-4000 fUmin(0-1220 rnlmin) Ambient Ratings Photoelectric Sensor Housing Color Frost White Sounder Operation Sounder Voltage 18 to 32 VDC from steady external source or from NAC Alarm Current(Sounder On) 20 mA @ 24 VDC,24 mA maximum @ 32 VDC 88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling Sounder Output Appliances and UL Standard 268,Smoke Detectors for Fire Protective Signaling Systems Sounder Power Supervision Supervised Select for continuous 24 VDC power,loss of power is communicated to panel (Selectable) Unsupervised Select when connected to NAC for sounder power,NAC provides supervision NAC Powered Operation When in alarm,will sound when NAC is in alarm,allowing synchronized pattern(Temporal or March Time,etc.)controlled by the NAC 4098-9822 Unsupervised Relay Option Externally Supplied Relay Voltage 18-32 VDC,steady source recommended(wires to remote LED leads) Alarm Current 13 mA from separate 24 VDC supply Contact Ratings,DPDT contacts for Power limited rating:2 A @ 30 VDC resistive/suppressed loads Non-power limited rating: 1/2 A @ 120 VAC Relay Operation Tracks base LED status,relay is on with trouble or alarm at the base TYCO,SIMPLEX,and the product names listed in this material are marks ancd'or registered marks.Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the Notional Fire Protection Association(NFPA). 0®Si m plev Tyco Fire Protection Products•Westminster,MA-01441-0001•USA S4098-0028-11 1/2015 www.simplex-fire.corn C 2015 Tyco Fire Protection Products.All rights reserved A11 specifications and other infonnation shown were current as ofdocument revision date and are subject to change without notice. EtSimplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNet and MAPNET ll Communicating Devices, MEA (NYC)Acceptance* Individual Addressable Modules (IAMs) - IDNet or MAPNET II addressable communications supply both data and power over a single wire pair Aiaiu riot ftcc:3ts co-. to provide**: 4090 900 SOTEMISfD 1,4C • Supervised Class B monitoring of normally open,dry MI.its't sit-33l Air COR- contacts • Total wiring distance from IAM to supervision mak' resistor(s)of up to 500 ft(152 in) 1 oppdotitip • Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications 4090-9001 Supervised IAM • For use in indoor locations up to 158°F(70°C)such as (shown approximately 3/4 size) attic spaces or similar applications For use with following Simplex control panels: • Model Series 4007ES,4008,4010,4010ES,and 41 ODES fire alarm control panels for ZDNet communications • Model Series 4100/4100U/4100ES,4120,4020,and 2120 Communicating Device Transponders(CDTs) equipped with MAPNET Il communications Model 4090-9001: • Enclosed design minimizes dust infiltration _x • Mounts in standard single gang electrical box • Screw terminals for wiring connections • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be 4090-9051 Supervised IAM viewed after installation(requires mounting bracket, (shown approximately 3/4 size) ordered separately) Model 4090-9051: • Encapsulated design for extended exposure to high humidity(LED is not present on this model) ❑escri.tion • Color coded 18 AWG leads for wiring Individual addressable modules (IAMs)receive IDNet communications provides current limited both power and communications from a two-wire monitoring: MAPNET II or IDNet circuit.They provide location • Provides monitoring of tamper switch(supervisory) specific addressability to a single initiating device(such and waterflow switch(alarm)on same circuit using as single station smoke detector alarm contacts or heat one point detector contacts)or multiple devices at the same location by monitoring normally open dry contacts and the wiring • Available with IDNet communications only to an end-of-line resistor. Multiple operation modes are available and are selectable at the control panel: Model 4090-9001 is packaged in a thermoplastic • Contact closure status can be tracked housing and provides screw terminal connections and a status indicating LED. • Momentary contact closure conditions can be selected at the panel to be latched or tracked(not available with the Model 4090-9051 is an encapsulated package with wire 2120 CDT) leads.It does not provide a status indicating LED. UL listed to Standard 864 • These products have been approved by the California State Fire Marshal(CSFM)pursuant to Section 131441 of the California Health and Safety Code.See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in'his document.Accepted for use—City of New York Department of Buildings—MFA35-93E. Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products 54090-0001-11 1112014 Operation Current Limited Operation Applications Contact Closure. Closure of the monitored contact(s) For use with IDNet communications only,these initiates an alarm or other response as programmed at the IAMB can provide quad-state sensing of normal,open fire alarm control panel.An open in the monitored circuit circuit,short circuit,and current limited conditions. wiring will cause a trouble to be reported. (Program type is"T-sense.")With the proper end-of-line Panel Selections.Selections can be made at the control and current limiting resistors,dual functions such as panel to maintain the alarm condition if the initiating tamper switch and waterflow switch monitoring can be device contacts are momentary,such as from a determined and communicated by a single addressable rate-of-rise heat detector,or to track the device contact point. status(not available with the 2120 CDT). IAM Product Selection Model Description 4090-9001 Supervised IAM,mounted in thermoplastic housing with screw terminals;see applicable options below 4090-9051 Supervised IAM,encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws;galvanized steel 4090-9810 Mounting bracket,mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses(ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 kt2, 1/2 W;Standard end-of-line resistor harness for N.O.contact supervision 4081-9003 733-896 4.7 kQ, 1/2 W Use for current limited monitoring applications 4081-9005 733-984 1.8 kt2, 112 W S•ecifications Electrical Power and Communications MAPNET II or ZDNet,auto selected, 1 address per IAM Input Requirements Normally open, dry contacts 4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire Wire Connections (0.82 mm2 to 2.08 mm2) 4090-9051 Color coded wire leads, 18 AWG(0.82 mm2),8"long(203 mm) Installation Instructions 574-331 for 4090-9001;579-572 for 4090-9151 Reference Documents Field Wiring Diagrams 842-073 for IDNet operation;841-804 for MAPNET II operation Wiring Distances 500 ft(152 m)maximum without protectors Distance from IAM to Contacts 400 ft(122 m)maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 2500 ft(762 m)maximum from fire alarm control panel IDNet Communications 10,000 ft(3048 m)maximum total wiring distance(including T-Taps) Mechanical 4090-9001 1-9116"Wx 1-314"H x 1-114"D(40 mm x 44 mm x 32 mm) Dimensions 4090-9051 1-9116"Wx1-9116"H x 9/16"D(40 mm x 40 mm x 14 mm) Housing Material,4090-9001 Black thermoplastic Encapsulation Material,4090-9051 Epoxy,beige Temperature Range 32°to 158°F(0°to 70°C);intended for indoor operation Humidity Range Up to 93%RH at 100°F(38°C) 2 34090-0001-11 11/2014 Mounting information 4090-9001 IDNet ! + wf Field wiring shown supervised IAM /ll for reference p �' c ---------------____________ ,It(ii...z_or - 0 IIIII 3ihBii II&r.:�;i4 fh I, '• '----- 41%1P 11,110,1 IIS!.',SSRIli-L r� "-'��^•� LED viewing port Ir [ ui!J' —. ' Single gang electrical �1i `~ box 2-112"(64mm) ® I minimum depth (supplied by others) Address setting under resealable label rio Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed(supplied by others) Mounting Reference, Single Gang Blank Cover Plate [ , 0 0 0 o Light pipe for [ im 1 LED viewing 4-114" 4-1/2' ( ) {114 mm 108 mm ) DISCONNECT POWER DISCONNECT POWER EEFORE SERVICING BEFORE SERVICING © © �o� ‘111111111 it • 2-112" 2-13116" (64 mm) 2-1/2" 1412-13/16" mm) Owl 4090-9806,Trim plate for 4090-9807,Trim plate for 4090-9810 Mounting semi-flush mounted box surface mounted box bracket, ordered separately NOTE:These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 2 S4090-0001-11 11/2014 4090-9051 Mountin. Information Address setting is ® at rear of housing ` 4090-9051 Encapsulated �� Supervised IAM I . 11111 ®a�a r�4 0011647) Single gang electrical box 2-112"(64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) EtS I m p 1 EX Tyco Fire Protection Products•Westminster, MA•01441-0001•USA S4090-0001-11 11/2014 A www.simptex-fire.com co 2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Carbon Monoxide *Th_ SYSTEM (CO) DetectionSENSOR' PRODUCTS Accessories Conventional Detectors • • • C . . co COI 224T & C01224TR Carbon Monoxide Detectors The C01224T and C01224TR are designed for system operation. These detectors are fully listed to UL 2075 and offer a code-required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.The C01224T and C01224TR also use • • • SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels. As 12/24 VDC detectors, the C01224T and C01224TR will operate on most security and fire alarm control panels. C . . Carbon Monoxide Detectors Co1224T 12/24 volt,4-wire system monitored carbon monoxide detector with ReallestTechnology,Square C0122TR 12/24 volt,4-wire system-monitored round carbon monoxide detector with RealTest Technology,Round Features • RealTestf enables a functional test using canned CO • Full compliance with UL 2075 • A code-required trouble relay • Wiring supervision with SEMS terminals • A six-year end-of-life timer Simplify Replacements . 12/24VDC with CO-PLATE • A low current draw of 20 mA in standby and 40 mA in alarm To upgrade competitive detectors to the CO12241, • Versatile mounting for wall or ceiling installers can easily connect the C01224T to existing wiring. In cases where the footprint of the old detector • Accurate and reliable electrochemical sensing technology must be covered,the CO PLATE perfectly covers the • Optional CO Detector Replacement Plate, CO-PLATE,to upgrade outline of the old and bulky competitive detector.The previously installed competitor detectors to the C01224T C01224T then mounts to the CO-PLATE for a clean, low-profile finish ideal for commercial and residential applications. CO-PLATY CO detector rep.acemeni plate' co Save Lives RealTest® You can save lives! According to the Journal of the American Medical The System Sensor C01224T Association(JAMA), carbon monoxide is the number one cause of and C01224TR CO Detectors unintentional poisoning deaths in the United States. provide RealTest—the first functional CO test fully compliant Installation Guidelines with NFPA 720:2009.With a simple short spray,anyone can test the CO sensing cell to verify The C01224TIC01224TR can be mounted to a single-gang box or surface it is working. mounted to the wall or ceiling. In a wall location, the detector should be at least as high as a light sw}tch and at least six inches from the ceiling. In a ceiling location, the detector should be at least 12 inches from any wall Push and hold the Test/Hush button for two seconds Where to Install CO Detectors to enter ReaiTest mode.The green • Within 10 feet of each sleeping area LED will flash once • Inside each sleeping area if occupied by the hearing impaired . . every second to indicate RealTest • Near kitchens with a gas burning stove mode has started. • On each floor of the house • Away from vents and the reach of children and pets Spray canned • In the vicinity of flame-fueled appliances, but no closer than 10 feet - Co agent into the detector. fr CO Detector Placement a Bedrooms �+ ;_ Verify CO sensing at the control panel. -- 1 1 The detector will automatically exit Reallest alarm mode after about 20-60 seconds. ,t u • " see Kitchen Basement Carbon Monoxide Detector location for multi-level residence systemsensor.comlco Features and Benefits RealTest The CO1224T and C01224TR detectors from System Sensor offer RealTest: a true functional CO test that's the first of its kind.With RealTest, a simple short spray of canned CO is all it takes. Now you can leave your job knowing the detector is doing its job. UL Listed T The 001224T/C01224TR is fully compliant with UL 2075. Electrochemical Sensing • . Electrochemical detectors are the newest, most reliable CO detectors available.They take the most accurate readings of CO, from low levels of CO that may be hazardous over long periods of time to high concentrations that present an immediate danger.They are also less prone to false alarms than other types of CO sensing technologies. End-of-Life Notification The CO-1224T and C01224TR are equipped with a six-year end- of-life notification system that alerts the central station at the end of each detector's functional life span.This enables service providers to proactively make service calls without the homeowner worrying about checking the detector. 62 , 000 SEMS Terminals The CO-1224T/C01224TR features SEMS terminals that provide electrical supervision and fast, easy wiring. People Poisoned by CO Annually Versatile Mounting Options The C01224T/C01224TR can be mounted to a single-gangelectrical box or surface mounted to the wall or ceiling with ample room for wire entry. Low Current Draw The C01224T/C01224TR has a current draw of 20 mA in standby and 40 mA in alarm.This means that mere CO detectors can be connected to the panel without purchasing a more expensive panel or an extra auxiliary power supply. 24-Hour Protection • Protect your customers with 24/7 central station monitoring;you can protect your customers from a poison they cannot see, smell, or taste. 4 111 CO Complete Co Detection r The system-connected CO1224T and CO1224TR CO detectors with RealTest •• • provide early warning by using reliable electrochemical sensing technology to measure CO levels in the air. If a dangerous amount of CO is detected, the CO1224T/CO1224TR will alert residents by sounding a Temporal 4 alarm tone and flashing its red LED. Protection is guaranteed 24/7 by an alarm transmission to a central station. regardless of whether residents are away from home, • • sleeping.or already suffering from the effects of CO. Benefits of Monitored Detection C01224T CO detectors monitored by a central station provide peace of mind Carbon Monoxide Detector by including an extra level of protection when: • The residence is empty • Residents are sleeping • Pets,children,and elderly are alone • Residents are already suffering from symptoms of CO exposure (drowsiness.unconsciousness, etc.) • A maintenance problem arises with the detector 50,0 rrrrti+,p', ;t���f If CO concentration reaches dangerous levels and triggers an alarm,the central cr" station has the abilityto contact the occupant and/or first responders.The central 0f homes have CO detectors installed. p p Fx. station will also alert the end user if the detector: • Has been tampered with • Is experiencing mechanical trouble • Is in sensor end-of-life due to the limited life span of CO detection technologies sT systemsensor.com/co 3 ®simplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; Audible Notification Appliances MEA (NYC) Acceptance* Speakers, 25 or 70.7 VRMS, Wall or Ceiling Mount �z - Fire alarm speakers with models for ceiling or wall mount: • Four inch cone(102 mm)provides high quality tone and voice reproduction - • • Multi-tapped design provides output power of/4, '/z, 1, or 2 W with either 25 or 70.7 VRMS input • In/out wiring terminals for 18 AWG to 12 AWG I • Mounts to 4"square outlet box, 1 ''/2"deep with 1 1/2" deep box extension • Capacitor input for connection to supervised notification y l appliance circuits F I A E. • Rugged,high impact,flame retardant Thermoplastic housings Rectangular Wall Mount Speakers are Available • UL listed to Standard 1480 as Red with White'Fire"Lettering and • ULC listed to Standard S541,refer to page 4 for White with Red"Fire" Lettering required minimum wattage tap per housing type • Compliant with NFPA 72,520 Hz Low Frequency Signal Requirements for Sleeping Areas K, Rectangular housing models feature: • Appearance that complements TrueAlert strobes and r+rf( speaker/strobes ll ` J� • Red or white housings with"FIRE"lettering for surface or semi-flush wall mount • Optional matching adapter skirts for covering surface mounted electrical boxes* • Optional red wire guard Round Speakers are Available in Off-White(no lettering) Round housing models feature: • Off-white color(no lettering)for flush mount on ceiling S.ecif icatlons or wall • Compatible with optional tile bridge 2905-9946 Dimensions,Rectangular Wall Mount Housings Housing Dimensions 5'/"H x 5°W x 1 Y"D I ntroduction (130 mm x 127 mm x 38 mm) Simplex®4902 Series speakers provide high quality sound Depth into Box 2 s1"(70 mm) for emergency fire alarm use as well as for background Dimensions,Round Housings music.The moisture-repellent speaker is designed for Housing Dimensions 7'/z"Diameter,'A"D smooth frequency response with minimal distortion. .(191 mm x'13 mm) The multi-tapped speaker transformer accommodates Depth into Box 2'/"(70 mm) either 25 or 70.7 VRMS and provides an output of from'/4 General Specifications to 2 W to provide flexibility for satisfying the Input Voltage 25 or 70.7 VRMS requirements of the installed conditions. _Power Taps '/, %2, 1,and 2 W Rectangular housing models are for surface or semi-flush Input Terminal Ratings 18 to 92 AWG z wall mount applications.Round housing models are (0.82 mm to 3.31 mm ) typically for ceiling applications but can be wall mounted Frequency Fire Alarm 400 to 4000 Hz if desired.The rectangular housing speakers are designed Response General 125 to 12 kHz to compliment the TrueAlert family of strobes and Signaling speaker/strobes,providing conventional,non-addressable Sound Output See information on page 4 speaker operation. Temperature Range 32°to 100°F(0°to 38°C) • Refer to page 2 for guard and adapter skirt hating.This product has been approved by the Humidity Range 10%to 95% RH from 32°to California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health 122°F(0°to 50°C) and Safety Code.See CSFM Listing 7320-0026:242 for allowable values and/or conditions concerning material presented in this document.Additional listings may be applicable; contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fre Protection Products. S4902-0003-7 5/2014 Product Selection Speakers Model* Description Dimensions 4902-9716(CA) Rectangular housing,wall mount Red with white"FIRE"lettering ' 5'/s"H x 5"W x 11/2"D 4902-9717(CA) speaker White with red"FIRE"lettering (130 mm x 127 mm x 38 mm) 4902-9721 (CA) Round housing speaker,ceiling or wall Off-white(no lettering) 7'/�'Diameter x'/2"D mount (191 mm x 13 mm) * ULC listed model are designated with a CA suffix(4902-9716CA). Refer to Installation Instructions 574-765 for non-suffix model numbers and to Installation Instructions 579-324 for CA suffix model numbers. Mounting Adapters Model Description Dimensions 4905-9941 Red Use to cover surface mounted 5'/e"H x 5'/a"W x 3 3/,6"D Surface mount adapter skirt; 1-112"deep box with 1-1/2" (136 mm x 133 mm x 81 mm) 4905-9942 White (not ULC listed) deep extension external to Total surface depth with wall(see diagram on page 3) speaker=4 / (117 mm) 2905-9946 Tile bridge for 4902-9721 Speaker See diagram on page 3 4905-9931 Adapter Plate, red,for mounting to 2975-9145 box(typically for retrofit, 8$/s"x 5 3/."x 0.060"Thick may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red mounting box, requires Adapter Plate 4905-9931 7'/g'x 5'/S'x 2'/"D (200 mm x 130 mm x 70 mm) Covers and Guard Model Description Dimensions 4905-9988 Red speaker cover with white"FIRE"lettering Interchangeable with 5'/B'H x 5"W x 1 '/2"D 4905-9989 White speaker cover with red"FIRE"lettering TrueAlert horns (130 mm x 127 mm x 38 mm) Red wire guard with mounting plate;compatible with semi-flush or surface 6 1/6a H x 6 /e"W x 3'/a°D 4905-9999 mounted boxes;for use with 4"square electrical box mounting hole (154 mm x 154 mm x 79 mm) patterns only(UL listedAge Electronics Inc.)bySpace ace p g Wall Mount S.eakers, Installation Reference Mounting requires a 4"(102 mm)square box, 1-1/2"(38 mm)deep,with a 4"box AMIIMigr extension,1-1/2"deep,by others im -I -1 Speaker assembly ' O I 1■ mix 6 0 �I • 0 R I l ,l®�OI I \ging input terminals and speaker tap OIF O selection are accessible from rear of �f speaker housing Aimin�nwumnmr2nE _ Transparent speaker • housing Removable cover (tool required) • Fl [1 GL5 2 54902-0003-7 5/2014 Round Speaker Installation Reference (typically ceiling mount, can be wall mounted) 4"square,1-112"deep box with 1-1/2"extension(by others) Wiring input terminals and speaker ✓ ✓ �a � tap selection are accessible from rear of speaker housing i✓ 6aPe 0 \,c• r �.� 1lfl 1111 /if Front View 2905-9946 Tile Brid•e Dimensions 0.024"thick sheet 3-314"(95 mm)square metal,folded with cutout,centered on plate 1/2" lip each side 112" (13 mm) n 13-318" 0 - (340 mm) 114"diameter(6 mm) p holes,4 places 6-11116" (170 mm) r V 23-11/16"(602 mm) Surface Mounted Speaker Reference (Adapter Skirts are Not ULC listed) 4"(102 mm)square box,1-112"(38 mm)deep with conduit shown for reference 4"(102 mm)square box extension,1-112"(38 mm)deep it um.l—'I Optional 4905-9999 Wire Guard 111 ELMii .Kamm—;I Speaker assembly 11. \1I1!L . Surface mount adapter skirt,3-3/16"deep: 4905-9941,Red;4905-9942,White Conduit knockouts are provided on all four sides Wall surface 3 54902-0003-7 5/2014 S•eaker Sound Out•ut S•ecifications Sound Output Ratings @ 10 ft(-3 m)per UL 1480 Reverberant Chamber Testing Model Type Input Voltage Selected Tap AW Y2 1W 2W 4902-9716 25 VRMS 80 dBA 83 dBA _ 85 dBA 88 dBA 4902-9717 Rectangular Housing - - 70/VRMS 79 dBA 82 dBA 85 dBA 88 dBA 4902-9721 Round Housing 25 or 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA Sound Output Ratings @ 3 m (-10 ft)per ULC S541 Anechoic Chamber Testing Selected Tap Model Type Input Voltage '/aW '/2W 1W* 2W* (see note) (see note) 4902-9716CA Rectangular Housing* 25 VRMS or 70.7 VRMS 77 dBA 80 dBA 83 dBA 86 dBA 4902-9717CA 4902-9721 CA Round Housing* 25 VRMS or 70.7 VRMS 79 dBA 82 dBA 85 dBA 89 dBA *NOTE: IJLC Fire Alarm applications require use of 1 W or 2 W tap for Round Housing speakers;and 2 W tap for Rectangular Housing speakers. Speaker Polar Dispersion Reference(per ULC S541 Anechoic Chamber Testing) Attenuation Angle -3 dB 30°off-axis -6 dB 55°off-axis 4905-9931 Ada•ter Plate Installation Reference 2975-9145 Box 4905-9931 Adapter Plate Aiiiiimm. mimimpir.i. 1111.111l O 4905-9999 Optional i --- N `�""'1mffs - - amism - Wire Guard P./. ■I�Iimmimm(shown here ��I T !II . m� reference only, aan iIIrIPhl 11l1 I be used on other �iurzi_10=i q I mounting options) �i��� P GI E FM- a R�wl I — 1-: . 4905-9931 Adapter Plate 0 Speaker assembly TYCO,SIMPLEX,and the product names listed in/his material are marks and-or registered marks,Unauthorr_ed use is strictly prohibited NEPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NEPA). ig itS i m p t Ex Tyco Fire Protection Products•Westminster,MA•01441-0001-LISA S4902-0003-7 5/2014 www.simpiex-fire.com 0 2014 T j. o Ere Proteelion Prochicts.All rights reserved All.specifications and other information shown were current at of document revision date and are smbject to change without notice.