Loading...
HomeMy WebLinkAboutA15-0077_Cut Sheets_1442335620.pdf Honeywell 5809 WIRELESS HEAT DETECTOR Honeywell's 5809 wireless fixed heat and rate-of-rise surrounding area.The 5809's rate-of-rise thermostat senses temperature sensor offers expanded fire detection and the rise in temperature and signals an alarm if the increase is installation flexibility. It is ideal for hard to wire locations and 15°or more per minute.A built-in fixed temperature sensor applications that require more than smoke detection. With no will also signal an alarm if the environmental temperature rises wires to run,the 5809 is fast and easy to install. above 135°F.The 5809 is UL Listed (UL521)and CSFM The 5809 combines both rate-of-rise and fixed temperature approved for commercial and residential applications. sensors. Fires typically cause a rapid rise in temperature in the FEATURES • Contains a built-in transmitter which battery. If the battery voltage gets too the control if the unit is removed from can send alarm, supervisory and low, the 5809 sends a low battery the mounting base battery condition messages to the signal to the control panel • UL Listed for Commercial (when using system's receiver/control unit • Features a tamper switch, which 5881 EH Receiver)or Residential • Powered by a three-volt lithium causes a trouble signal to be sent to applications 5809 WIRELESS HEAT DETECTOR SPECIFICATIONS: • Power: - Fixed temperature: 135°F(57°C) Residential applications - 3V lithium battery(Duracell DL123A, - Maximum spacing: 50 ft x 50 ft UL, •Wireless Transmission Path Test: Panasonic CR123A, Sanyo CR123A, 30 ft x 30 ft FM (refer to National Fire -A good RF transmission path must Varta CR123A) Alarm Code Standard NFPA 72 for be established from the proposed - Operating temperature: 40°to application requirements) mounting location before permanently 140°F(6°to 60°C) - Dimensions: 4.4"diameter/2/2" installing the detector. To determine - Rate-of-rise temperature: 15°F(8°C) deep that there is a good signal reception increase per minute(NOTE: Rate of •Agency Listings: from the proposed location, perform rise sensor does not operate above - UL 521 Listed for Commercial the test procedure described in the 38°C) (when using 5881 EH Receiver)or installation instructions procedure. MOUNTING THE DETECTOR: - You can mount the 5809 on a wall or - Refer to NFPA Standard 72 for be used for property protection. ceiling within the protection area: detector spacing and other Reliance should not be placed soley - Wall mounting: Mount the detector requirements. Maximum spacing for on heat detectors for life safety. 4" 6"from the ceiling UL installations is 50' x 50' When life safety is involved, smoke Ceiling mounting: Mount the detector -Avoid mounting the detector near detectors MUST also be used. at least 4"from any wall. Make sure heat generating devices (e.g. ovens, Detectors must not be painted. the normal ceiling temperature will not heat vents, furnaces, boilers) exceed 100°F(37.8° C). IMPORTANT: Heat detectors should TESTING THE DETECTOR: The test procedure should be performed - Use either method (a)or(b)or activate - Exit the control's test mode to determine a good RF transmission the detector FCC ID: CFS 8DL 5809 path and again after installation is completed. (a) Press and release the activation This device complies with part 15 of button on the PC board assembly OR FCC rules. CAUTION:The fixed temperature sensor (b) Holding a portable hair dryer about Operation is subject to the following is intended for one-time use. Prolonged 12 to 18 inches away from the detector, conditions: heat during testing can damage the unit. turn the dryer on and aim the warm air (1)This device may not cause harmful If used carefully following the instructions at the side of the detector. interference, and (2)this device must described below,the heat from a portable CAUTION:Aiming the dryer directly at accept any interference received, hair dryer can be used to test the unit. If the round disk on the detector can including interference that may cause the round disk on top of the detector damage the unit to be replaced. undesired operation. detaches,the detector must be replaced. -The system's keypad should beep and -Activiate the control panel's test mode the detector's ID should be displayed ORDERING 5809 Heat Detector Honeywell Security&Custom Electronics Honeywell Honeywell 2 Corporate Center Drive Suite 100 P.O. 9040 Melville, NY 11747 U5809/D www.honeywell.com October 2007 r 2007 Honeywell International Inc. Honeywell 580000 CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER Vi • S 415 S UL The 580000 is a 3V battery powered wireless carbon The detector consists of an electrochemical carbon monoxide (CO)detector intended for use with Honeywell monoxide sensor assembly coupled with a wireless alarm systems that support 5800 Series wireless devices. transmitter. The transmitter can send alarm, trouble, It provides early warning when its electrochemical sensing end-of-life, tamper and low battery condition messages technology measures carbon monoxide levels in the air. to the alarm panel. The 580000 is specifically designed for system operation Since there are no holes to drill or wires to run, you can and is fully listed to UL 2075 as a system supervised preserve the beauty of the home or building while detector.* It contains a piezoelectric horn which generates protecting its occupants from harmful carbon monoxide the ANSI S3.41 temporal 4 pattern in an alarm condition. gas. The 580000 is an ideal carbon monoxide detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist. What is Carbon Monoxide and How Can it Harm Consumers? Carbon monoxide (CO)is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels such as wood, gasoline, charcoal and oil are burned with insufficient air. The majority of residential and commercial fatalities caused from these fuels come from heating systems, engine powered tools and charcoal grills. Carbon monoxide is harmful when inhaled because it displaces oxygen in the blood and deprives the heart, brain and other vital organs of oxygen. Large amounts of CO can overcome a person in minutes without warning—causing them to lose consciousness and suffocate. The 580000 is designed to warn the end-user well before the CO reaches a fatal level. The detector's CO sensitivity is evaluated to UL 2034. CO Levels and Time to Alarm CO Concentration Min. Time to Alarm Max. Time to Alarm 30 ppm +/- 5 ppm 30 days Indefinite** 70 ppm +/- 5 ppm 60 minutes 240 minutes 150 ppm+/- 5 ppm 10 minutes 50 minutes 400 ppm+/- 5 ppm 4 minutes 15 minutes *For a complete list of products that support system operation of the 580000 to UL standard 2075, please visit: www.honeywell.com/security/hsc/resources/agency/co **Life of product 580000 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER KEY FEATURES Electrochemical Sensing Technology- Electrochemical Full Supervision - The 580000 is fully supervised to monitor detectors are the newest, most refined CO detectors available for low battery, case tamper and trouble conditions. and provide the most accurate measurement of CO Test/Hush Button-This dual purpose button allows the concentration obtainable. They can take readings from low end-user to perform periodic testing of the detector. In the levels that may be hazardous over long periods of time to event of a CO alarm, this button will silence the local sounder high concentrations that present an immediate danger. alarm for a five minute period. Note: the Hush feature will not Local Sounder-A built-in piezoelectric horn generates the operate at levels above 350 ppm (parts per million)carbon ANSI S3.41 temporal 4 pattern in an alarm condition. The monoxide (see figure 1). local sounder will also alert the end-user of other conditions Versatile Mounting - Whether you choose to affix the such as low battery, detector trouble and end-of-life. detector to the ceiling or a wall, mounting is made simple LED Status Indicators- Dual LEDs provide local visual with the enclosed hardware. The mounting base has large indication of the detector's status—including normal operation, mounting ports, which accommodate drywall anchors for alarm, low battery, trouble and end-of-life (see figure 1). easy surface mounting (see figure 2). End of Life Timer- When the detector has reached the end Tamper Protection and Tamper Resistant Element- of its life, the detector will send a trouble signal to the panel. The detector has a built-in tamper switch that can This indicates that the CO sensor inside the detector has communicate back to the control panel in the event it is passed the end of its life and the detector needs to be removed from the base. For an added level of security, replaced. The detector's lifespan is approximately six years the detector also includes a tamper resistant element that from the date of manufacture. prevents removal from the base without the use of a tool (see figure 2). MOUNTING SCREWS A (INSTALLED) El TEST BUTTON .,3° oolnal 1111111111111 V ` \ )D6')',0) >b -YO O4)bA �,°+ a°� NsnH 1s�1 ooyo� sa 10* 1 ddmB TAMPER 6 RELEASE TAB O z GREEN LED ^� EEST RED LED ESZ 0 Q J/ GQ ENGAGE NOTCH WITH TAMPER RELEASE TAB ON BASE AND TURN CLOCKWISE TO LOCK Figure 1 Figure 2 580000 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER MOUNTING RECOMMENDATIONS CO is slightly lighter than air and when heated by a fuel-burning source, the lighter weight and warm temperature of the CO causes it to quickly rise to the ceiling and mix freely with the air. Check with the local Authority Having Jurisdiction (AHJ)for CO detector requirements in your area. Some recommendations for installing the 580000 are as follows: - On every floor of the facility - Inside any areas that contain a fuel-burning appliance - In the vicinity of flame-fueled appliances, but no closer than 10 feet / Ak ■ • For wall mount BEDROOM - The detector should be at least as high as a light switch and at least six inches from the ceiling TO BEDROOM BR BEDROOM • For ceiling mount ■ KITCHEN GARAGE - The detector should be at least 12 inches from CLOSED LIVING DOOR any wall ROOM MIN • CARBON MONOXIDE ALARM LOCATION FOR MULTI-LEVEL RESIDENCE SPECIFICATIONS • Power Source: One 3V CR123A lithium battery(included) • Audible Signal (temporal 4 tone): 85 dB in alarm (at 10 ft.) • Height: 2.3" (58mm) • Diameter: 5.3" (135mm)with mounting base • Weight: 7 oz. (241 g)without battery • Operating Ambient Temperature Range: 32° F to 100° F(0° C to 37.8° C) • Operating Humidity Range: 15% to 95% relative humidity, non-condensing • Agency Listings: - Listed to UL standard 2075, *CO sensitivity is evaluated to UL 2034 - 580000A ULC Listed - tested to the CAN/CSA 6.19.01 standard ORDERING 580000 Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter 580000A Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter with ULC listing *For a complete list of products that support system operation of the 580000 to UL standard 2075 and 580000A ULC standard, please visit: www.honeywell.com/security/hsc/resources/agency/co Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 L/58000D/D Melville, NY 11747 March 2009 March 2009 www.honeywell.com ©2009 Honeywell International Inc. i I I • 1 .. lait4 • 5800WAVE WIRELESS SIREN • Honeywell's 5800WAVE is a fully wireless siren that provides periodic status information and battery back up for an added level of performance and protection. The flexible design simplifies installation, saves time and installs in seconds at any location without the need to run wires. System status is shown on the 5800WAVE with three LED's directly on the front of the unit. FEATURES • Siren output level is 95 dB at three feet • AC powered with a rechargeable • Lowers labor costs and 12 hour battery backup saves time •Transmits module status, including mounting tamper, low battery and • Plugs in to any standard duplex • Simplifies installation AC loss to the control panel receptacle and installs in seconds • Compatible with LYNXR(Rev 10 • LED; show system status of the device • Provides temporal pulse sounding for or higher)and VISTA controls that fire alarms support the 5883 transceiver SPECIFICATIONS • Dimensions: 4.5" W x 7.5" H x 2.25" D • Frequency of Operation: 345 MHz • Current: 202mA Typical (114mm x 191 mm x 57mm) • Input Voltage: 120VAC • Operational Temperature • Output Level: 95 dB at three feet 32° F to 122° F(0°to 50°C) ORDERING mi IMMO' 5800WAVE Wireless Siren Honeywell Security&Communications Honeywell Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 U5800WAVE/D March 2008 www.honeywell.com ©2008 Honeywell International Inc. Honeywell 5808W3 < 0 PHOTOELECTRIC SMOKE/HEAT DETECTOR WITH BUILT-IN ( 1 WIRELESS TRANSMITTER ir4r. _ Honeywell's 5808W3 is a 3V lithium powered, Since there are no holes to drill or wires to run, you can photoelectronic smoke/heat detector with a built-in preserve the beauty of the building while protecting it.The wireless transmitter. It is intended for use with any 5808W3 is an ideal smoke detector for those difficult to wire 5800 Series Wireless Receiver/Transceiver for residential locations, applications where room aesthetics are critical, or installations(for commercial installations,the 5881 ENHC where hazardous materials exist. or the 5883H receiver is required). All models also feature a restorable, built-in, fixed temperature The transmitter can send alarm, tamper, maintenance(when (135°F)thermal detector that is also capable of sensing a control panels are equipped to process maintenance signals), pre-freeze condition if the temperature is below 41°F. and battery condition messages to the system's receiver. Smoothing algorithms minimize nuisance alarms by smoothing out short term spikes from dust and smoke— virtually eliminating nuisance alarms. FEATURES • Improved Robust RF Field • Drift Compensation • Easy-to-install Mounting Base Strength Virtually eliminates nuisance alarms The sturdy mounting base allows the The distance between the detector from long-term dust build-up by detector to be more easily installed and receiver has been significantly automatically adjusting the detector's on uneven surfaces(i.e. stucco). The increased without the need for a sensitivity mounting base has larger mounting repeater • Removable Detector Cover and ports, which accommodate drywall • Smoothing Algorithms Chamber Top anchors for easy surface mounting. Mathematical calculations in the The technician is able to quickly and detector's software that minimize easily clean the detector chamber ADDITIONAL FEATURES: nuisance alarms by smoothing out without disassembling the detector . Utilizes one long life 3V lithium short term spikes from dust and head battery smoke • Approved UL Listings for Residential pp g Microcontroller runs on a 4.0 MHz • Smart Check and Commercial Applications clock A signal is sent to the control panel Both residential and commercial • Horn operates at 3.3 KHz with sound when the detector requires cleaning. installation requirements are met pressure level of 85 dBA at 10 feet This allows a regular, non emergency •Additional LED Status Indicators • Built-in wireless transmitter, temporal service call to clean the detector Identifying between alarm or trouble code 3 sounder before it goes into alarm. conditions is a snap with green and • Maintenance signal fully complies red LED status indicators.A green LED with the sensitivity test requirement denotes a normal condition while the specified in NFPA 72, 7-2.2 and is red LED indicates abnormal conditions. approved by UL 5808W3 PHOTOELECTRIC SMOKE/HEAT DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER SPECIFICATIONS • Dimensions •Air Velocity • Power Source -Diameter: 5.3"*, Height: 2.30" - 1,000 ft./min. max. -One 3V CR123A lithium Batteryt •Weight • Operating Voltage •Audible Output -8.5 ounces(without batteries) -2.5-3.6VDC -85 dB min. at 10 ft. • Operating Temperature • Standby Current • Fixed Temperature Heat Sensor -32-100° F(0-37.8°C) -8.5 mA avg. -135° F Fixed • Humidity Range •Alarm Current •Agency Listings -0%to 95% RH, non-condensing -35 mA max. -UL268-Commercial and Residential With adapter bracket(4.9"without mounting base) t Replacement batteries include Duracell DL123A,Sanyo CR123A,Panasonic CR123A,or ADEMCO 466 ACCESSORIES(sold separately) SENS-RDR Infrared ,, RT Removal Tool Sensitivity Reader . ... ........ .... Simplifies the attachment • . Reduce testing time with the . • and removal of the handheld SENS-RDR infrared detector head to the . `' `.,. sensitivity reader.The reader mounting base; it may _ _§ • _ simplifies sensitivity measurements be attached to a threaded . .- and displays them precisely in �. extension pole or broom ; , terms of percent per foot handle thereby eliminating obscuration. The SENS-RDR the need for ladders. eliminates the need for magnets, voltmeters and ladders. ORDERING 5808W3 Photoelectric Smoke/Heat Detector with Built-in Wireless Transmitter Accessories sold separately: SENS-RDR Hand-held Sensitivity Reader RT i3 Removal Tool used for easy installation and removal of head from base Automation and Control Solutions Honeywell Honeywell Security&Communications Hone 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 L/5808W3DS/D September 2008 www.honeywell.com ©2008 Honeywell International Inc. 6160RF M DELUXE CUSTOM ALPHA INTEGRATED KEYPAD/RECEIVER - S 1 WITH DOOR ATTACHED The 6160RF's integrated keypad and receiver design helps reduce Dealers can add the 5828 and 5828V wireless keypads to VISTA installation, material and inventory costs while increasing valuable for the first time, presenting a tremendous upsell opportunity by add-on opportunities. It adds full wireless capability to any VISTA letting them offer their customers secondary wireless keypads on control without additional wiring or sacrificing zones and can help every installation with virtually no install time. close sales by easily adding 5804, 5804BDV or 5878 wireless interfaces for end-user remote convenience. FEATURES • 6160 Custom Alpha Keypad •The 5800TM Module needed to • Comfortable soft-touch keys labeled • Built in 5881 ENH unlimited zone support the 5804BD and 5804BDV with simple commands are illuminated wireless receiver is already built-in for nighttime visibility • Compatible with 5828/5828V wireless • Supports encrypted operation • Four larger function keys can be keypads on VISTA systems* of the 5804E and 5804BDV programmed for one touch operation • Single four-wire run is all that's required four-button keys and are accessible even when the door is closed • It is the ideal choice where wireless keys are to be used: Easy to Operate - Keys can be programmed at the panel, •The custom alpha display is easy Stylishly Designed just as they would with the 5881 ENH to read, with large characters and • Sleek,white design blends with any decor • Fully compatible with all 5800 wireless simplified descriptions • Contoured, removable door lets devices including bidirectional devices* •The sounder beeps to help identify customers customize the keypad for security system status the look they want *Not compatible with 5839 •With the door closed the keypad has a smooth, unobtrusive appearance SPECIFICATIONS Dimensions Wiring Current • 5 5/16" H x 7 3/8" W x 1 3/16" D • -(Black): Ground • Standby: 50ma (135mm x 190mm x 30mm) •+(Red): +12 VDC(Aux. Power) •Activated: 150ma Sounder • D1 (Green): "Data In"to control panel Compatibility • Piezoelectric • DO(Yellow): "Data out" from • Fully compatible with all VISTA controls control panel ORDERING: 6160RF Keypad/Receiver 5828 Wireless Fixed English Keypad 5828V Wireless Talking Fixed English Keypad Honeywell Security&Custom Electronics Honeywell Honeywell 2 Corporate Center Drive Suite 100 P.O. Box 9040 Melville, NY 11747 116160RF/D September 2007 www.honeywell.com ©2007 Honeywell International Inc. Honeywell VISTA- 128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS II, - foli t� ��s. ,'RAR The VISTA-128BPE is a powerful member of the Honeywell The VISTA-128BP and VISTA-128BPE(VISTA-128BP Rev.4) family of commercial alarm panels, integrating burglary, CCTV are Listed for residential burglary, residential fire and commercial and access control functions. Many features are available that burglary applications(see agency listings in this document for extend the applications of the VISTA-128BP while simplifying more details).They are compatible with a wide range of end-user operation. AlarmNet communications products for alarm reporting, uploading/downloading and remote services. FEATU RES Standard features • Zone 7 may be used for keyswitch • Scheduled check-in (VISTA-128BP and VISTA-128BPE): arming/disarming • Arm stay by group • Provides nine style-B hardwired zones • Supports V-Plex® addressable VistaKeyaccess control (upto eight Enhanced features • Supports up to 119 additional zones (VISTA-128BPE only): using a built-in polling (V-Plex, doors and 250 cards) multiplex)loop interface • Easily programmed and maintained • Carbon monoxide(CO)zone • Supports up to 127 wireless zones by Compass Windows-based type support using up to two 5800 series wireless downloader • Expanded RS-232 capability receivers (fewer if using hardwire • Supports up to 96 programmable for third party interface and and/or polling loop zones) outputs automation • Provides one power-limited bell circuit • Programmable to meet SIA false • Internet upload/download over delivering 1.7Amp (max)at 12Vdc alarm prevention specifications. AlarmNet GSM, iGSM and IP • Provides the ability to control eight To meet UL approval for ANSI/SIA communicators over the panel's separate partitions independently, CP-01-2000 order part number keypad (ECP)bus each functioning as if it had its own VISTA-128SIA • Ringback support for AlarmNet separate control • Panel Linking up to eight panels communicators(confirmation of • Accommodates 150 user codes with closing report) • Supports eight numeric seven authority levels pager numbers • 24-hour dialer test support for AlarmNet devices • Accommodates 32 keypad macro • Supports touchscreen Advanced commands per system User Interface(AUI) • Keeps a log of up to 512 events • Smoke detector reset at keypad • VistaView-100 CCTV support • Quick exit • Supports up to 16 compatible two- • Group bypass wire smoke detectors on zone 1 • Arm faulted • Supports up to 50 latching-type • Event arming glassbreak detectors on zone 8 Honeywell VISTA- 128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ADDITIONAL FEATURES Basic Hardwired Zones • Tamper protection for supervised • A Master partition(9), used strictly to Provides nine style-B hardwired zones transmitters assign keypads for the purpose of with the following characteristics: • Individually assignable to one of viewing the status of all eight partitions • EOLR supervision (optional for zones eight partitions at the same time(master keypads) 2-8)supporting N.O. or N.C. sensors Scheduling • All zones assignable to one of (EOLR supervision required for fire Provides the following scheduling eight partitions and UL burglary installations) capabilities: • Keypads assignable to one of eight • Individually assignable to one of • Open/close schedules (for control of partitions or to Master partition 9 to eight partitions arming/disarming and reporting) view system status PollingLoopExpansion • Ability to assign relays to one or all p Holiday schedules(allows different Supports up to 119 additional zones time windows for open/close eight partitions using a built-in polling (V-Plex, multiplex) schedules) • Ability to display fire and/or burglary loopinterface. Current draw can totaland panic and/or trouble conditions • Timed events (for activation of relays, up to 128mA. Polling loop zones have auto-bypassing and unbypassing, at all other partitions' keypads the following characteristics: (selectable option) auto-arming and disarming, etc.) • Must use V-flex devices • Access schedules (for limiting system • Individually programmable account • Supervised by control panel access to users by time) number, entry delay and exit delay by partition • Individually assignable to one of • End user output programming mode eight partitions (provides 20 timers for output control) Wireless Expansion Eight Partitions Supports up to 127 wireless zones Provides the ability to control eight using up to two 5800 series wireless separate areas independently, each receivers(fewer if using hardwire functioning as if it had its own separate and/or polling loop zones). control. Partitioning features include: Wireless zones have the following • A Common Lobby partition (1-8), characteristics: which can be programmed to arm • Supervised by control panel for automatically when the last partition check-in signals (except certain that shares the common lobby is non-supervised transmitters) armed, and to disarm when the first partition that shares the common lobby is disarmed I1 = I V-Plex Loop . 1 3 I I I .....4,. _I FG1625SN Glassbreak 4208U Eight-zone 5193 4101SN DT7500SN Expansion Module and 4293SN Adapters Series Smoke Detectors Relay Module V-Plex DUAL TEC 4208EX Eight-zone Motion Sensor V-Plex Expander 5881 ECP Bus Wireless Receiver ---J 6160 ._ . Console gh Parallel Printer RS-232 LightIiii Notification ' • PliR4204 1 Appliances Keyswitch -- Module Serial Printer Y� ° Option 7.as-1.- .-- 4146 1 ' I > Phone Line to Central Station ., 748 Horn Alpha Paging .•.. —or— —or-- -- Module I 7847i GSM iGSM NOTE:Please refer to the website(www.honeywell.com/security/hsc)for the latest product information. Honeywell VISTA- 128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ACCESSORIES Auxiliary Devices • 5193SD Wireless Devices • 4204- Relay Module, four form C • 5193SDT • 5804- Wireless Key contacts Passive Infrared Detectors • 5804BD- Bidirectional Key • 5881 Series RF Receiver supporting • 998MX • 5804BDV- Bidirectional with voice 5800 wireless detectors • 6160 Alpha Keypad/Annunciator • IS2500SN • 5816- Door/Window Transmitter • 6220S- System Printer used with • DT7500SN • 5819 Shock Sensor 4100SM serial module • QUEST2260SN • 5827BD- Bidirectional Keypad • VA8200- (PLM)Panel Linking Module V-Plex(Addressable)Contacts • 5853- Glassbreak Detector • VA8201 - (APM)Alpha Paging Module • 4939SN-WH • 5894- Wireless PIR Motion Sensor Manual Pull Stations • 4944SN-WH • 5890- Passive Infrared Detection • 5140MPS-1 • 4959SN, 9500SN • 5800PIR-OD- Outdoor • 5140MPS-2 V-Plex Glassbreak Detectors Motion Sensor •V-Plex(addressable) Devices • FG1625SN 5870API Asset Protection Device •• 4101SN Single Relay/zone Module VISTA Interactive Phone Module 5800—Wireless RES/Detect Detectors Motion Detectors • 4190SN Remote Point Module- • 4286 VIP Module • 580000/A Wireless Carbon two zones Optional Communicators Monoxide Detector • 4193SN Two zone Serial Interface • AlarmNet Internet/Intranet • 5800RP-Wireless Repeater Module communicators and digital cellular •• 4208EX- Eight zone expander for communicators 5808W3 Wireless Smoke Detector ULC commercial installations Access Control • 5809- Wireless Heat Detector • 4208U Loop Expansion Module • VISTAKey V-Plex(addressable) Commercial Listed eight zones Access Control Wireless Devices • 4209U Group zoning Module • VISTAKey-SK Starter Kit • 5817CB- Commercial UL Burglary, two/four zones Universal Contact Monitoring • 4293SN One zone Serial Interface • VISTAKey-EX Expansion Kit Transmitter* Module • 5869- Commercial UL Wireless • 4297 Isolation/Extender Module V-Plex CCTV Hold-up Button* (addressable)smoke detectors • Optiflex CCTV module • 5881 ENHC and 5883H Receivers • VSI Short/Overload Isolation Module *When used with 5881ENHC and/or 5883H receiver. , a�' MJ 4190SN 4959SN 4944SN IS2500SN 4208U 4193SN Remote Point Module Overhead Door Contact Contact VISTAKey V-flex V-flex PIR Eight-zone Serial Interface Module Access Control Motion Sensor Expansion Module 5808W3 Module 5881ENHC Wireless Glassbreak Detectors 11111/ Commercial Wireless(MaxoSmoke ECP Bus Max Two) — Detector 5800 Series 5890 ' Wireless — "W= 6160 5816 Devices Wireless PIR Console Door/Window -- Transmitter I ` ,...Jimori4209U .� � `� Group Zoning �, �, Module ,1.0114,5869 Commercial UL- I Supports Up To L 51, 4204 Wireless Hold-up 5817CB Universal 16 Conventional ._ Relay 4204CF Button Contact Monitoring Two-Wire Module Supervised Smoke Detectors 4111.IN' • NAC Module Transmitter iirmato Panel Linking Module Panel Linking Module VISTA- 128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS SPECIFICATIONS Agency Listed to the Electrical Main Dialer Following Standards: • Voltage Input: From Honeywell No. • Formats Supported: ADEMCO • UL609 Grade A Local Mercantile 1361 Plug-In Transformer or Contact ID, ADEMCO High Speed, Premises and Mercantile Safe 1361X10 transformer(for X-10 ADEMCO 4 + 2 Express, ADEMCO and Vault installations)rated 16.5VAC,40 VA Low Speed, Sescoa and Radionics • UL611/UL1610 Grades A, AA • Use 1361CN plug-in transformer Low Speed Central Station for Canada • Line Seize: Double Pole • UL365 Grades A, AA Police Connect • Alarm Sounder Output: 10VDC- • Ringer Equivalence: 0.7B • UL985 Household Fire 13.8VDC, 1.7 amps max., (UL1023, Cabinet Dimensions UL609 installations); 750mA less aux. • UL1023 Household Burglar Alarm current draw (UL985 installations) 12-1/2"W X 14 1/2" H X 3" D California State Fire Marshall (CSFM) • UL1635 Digital Alarm • Auxiliary Power Output: 9.6VDC- Communicator System Units 13.8VDC, 750mA max. For UL installations, the accessories • CAN/ULC- S303 connected to the output must be UL • CAN/ULC- S304 Listed, and rated to operate in the • CAN/ULC- S545 above voltage range • CAN/ULC- S1023 • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid. YUASA NP4-12 • For commercial burglary attack proof (12V, 4AH)or NP7-12 (12V, 7AH) requirements, use VISTA-ULKT attack recommended proof enclosure • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). ORDERING VISTA-128BP Commercial Burglary Alarm Control Panel (UL Listed) VISTA-128BPE Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending) VISTA-128SIAE SIA Approved Enhanced Commercial Burglary Alarm Control Panel For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications 2 Corporate Center Dr. Suite 100 Honeywell P.O. Box 9040 Melville, NY 11747 UVSTA128BPD/D 1.800.467.5875 April 2010 www.honeywell.com ©2010 Honeywell International Inc. SYSTEM �$ SENSOR 5600 Series Mechanical Heat Detectors 5601P 4 System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. .15T 5621 Features Multiple configurations.The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both • Multiple configurations for installations: single-and dual-circuit models are available for low-and high- —Single-and dual-circuit models temperature ratings with either fixed temperature or combination —Fixed temp and combination fixed-temp/rate-of-rise fixed temperature/rate-of-rise(ROR)activation.The ROR element of 135°F or 194°F ratings. the fixed/ROR models is restorable to accommodate field-testing. • Plain housing for residential installations(Model 5601P) • Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back • A broad range of back box mounting options: boxes.And these models accommodate four-square back boxes, —Single gang when used with a square to round plaster ring.The reversible —3.5"and 4"Octagonal mounting bracket permits both flush-and surface-mount back box —4"square with square to round plaster ring installations. • Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/ rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings ® LISTED APPROVED ® ARvi S2101 3016008 CSG?0 7270-1653:0167 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90°C),and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor.The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P,5603,5621,and 5623: 100°F(38°C) 5602,5604,5622,and 5624: 150°F(65.6°C) Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601P,5603,5621,and 5623: 135°F(57°C) 5602,5604,5622,and 5624: 194°F(90°C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 15°F(8.3°C)rise per minute(models 5601P,5602,5621,and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact 6-125VAC/3A Ratings 6-28VDC/1A 125VDC/0.3A 250VDC/0.1A Input Terminals 14-22 AWG O O I?t OO IMOy 5601 P 5602,5622 5603,5623 5604,5624 5621 Ordering Information Identification Method Temperature UL Protected Spacing—10 Foot Model Circuit on Exterior Rating Activation Ceiling* 5601P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) °NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. $T SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com for current product information,including the latest version of this data sheet. www.systemsensor.com SPDS30001•7/13 ,T SYSTEM - �$ SENSOR° Mini-Horns = - The SpectrAlert®Advance series of mini-horn sounders are designed to simplify installations to provide - primary and secondary signaling for fire and security -- ______ _, applications. SPECTRIert A N C Features The MHR and MHW mini-horns operate at 12 and 24 volts and are 12 and 24V operation ideal for hotel,motel or residential fire system applications,where • a smaller notification device is desired.The mini-horns offer high •High and low volume settings and low volume settings,and temporal or non-temporal tones. The •Temporal and non-temporal tones horns can be mounted to single gang back boxes for aesthetically •Mounts to single gang back box sensitive applications. Synchronization is also provided when using the MDL module. •Compatible with MDL sync module •Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-Alert-sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings UL S Nc 4* MEA R"‘ approved APPROVED 54011 3028007 MEA7-07-E 7135-1653196 SpectrAlere Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini- horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.When used with the Sync•Circuit""Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9"W x.45"D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:deep single-gang back box(23/4"deep) Flush:Standard 4"x 4"back box Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output(dBA) Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non-temporal High 72 71 75 74 80 79 4 Non-temporal Low 70 69 73 72 78 77 Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini-Horn,Red MHW Mini-Horn,White *--. SYSTEM m2009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Vsit systemsensoccom for ._)' SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0414-001.12/09•#2266