HomeMy WebLinkAboutA15-0090_FA000_1457542440.pdf ii1 X44! X LEGEND : Vail Fire&Emergency Services 03/09/16 SYMBOL DEVICE MANUFACTURER/PART# MOUNTING FACP Honeywell Vista-128BPT Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox 1 KP LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox OCombination Smoke & System Sensor i3 series 4WTA—B Heat Detector w/Sounder w/4193SN Addressable module 4" square box OCombination Smoke and Address Type of Device Level Description �o CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box 001 MONITOR MODULE 1 SPRINKLER WATERFLOW 002 MONITOR MODULE 1-,SPRINKLER TAMPER ® System Sensor 5601P z 003 CO/SMOKE DETECTOR 1 EXERCISE AREA Heat Detector w/4193SN Addressable module 4" square box P I- 004 CO/SMOKE DETECTOR 1 THEATER E 005 SMOKE DETECTOR 2 NE BEDROOM © v Cosmo Interface Module COSMOD4W v 006 SMOKE DETECTOR 2 NW BEDROOM o 007 SMOKE DETECTOR 2 SOUTH BEDROOM z 008 'CO/SMOKE DETECTOR 2 LEVEL 2 HALLWAY ❑M 0 Addressable Monitor Module 4193SN Addressable module v 009 CO/SMOKE DETECTOR 3 MUDROOM w 010 HEAT DETECTOR 3 GARAGE r 011 CO/SMOKE DETECTOR 4 LIVING ROOM KB Knox Box 012 CO/SMOKE DETECTOR 4 MASTER BEDROOM 013 014 - Q Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox 015 1- 016 GENERAL NOTES: o 017 018 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER STANDARDS, 019 v FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. 0 020 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR FURTHER Z 021 approved as noted. INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, PROGRAMMING AND DEVICE 022 OPERATION. N l- 023 _ O z 024 rn 025 rn Q 026 CO 027 ®� v) OI o U 028 029 * .a, .I la a' gew- rn Ua,�vo L I: I030 Q;..�.,EIGk . c031 �' ,' �fi�, �_ o z 032 ' i 4 _ Q 033 ovP 352331 rn .r• g ®� CL _ 034 l ar• C'r 036 �".. 81Gf�tAVc100'� =' ati 3 037 038 i o® 039 040 a.i. NOTE: LEVEL WILL BE INCLUDED IN DEVICE ADDRESS DESCRIPTION. D = 4—WIRE DATA/POWER, 4—#16AWG (2 PAIR) I X = 2—WIRE DATA, 2—#16AWG N = 2—WIRE SOUNDER CIRCUIT, 2—#18AWG Battery Calculations _ Ademco Vista 128 FACP L = 2—WIRE DATA CIRCUIT, 2—#16AWG 1 1 Standby KP = KEYPAD CIRCUITING, 4—#18AWG • Number of Current Total Current t 0 0 Device Type Devices (Amps) (Amps) RISER NOTES: 00 Main FACP CPU 1 X 0.032 = ' 0.032 6150 Keypad 1 :C 0.04 - _ - 0.04 1. REFER TO VISTA 128 INSTALLATION MANUAL FOR co L7io i3 Smoke Detector with Sounder 3 X 0.00005 = 0.00015 MORE INFORMATION. EOL rO i4 COSMO Smoke/CO Detector wlSounder 6 ' X 0.00005 = 0.0003 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETSi. COSMO Interface Module 6 X 0.022 = 0.132 MANUFACTURERS SPECIFICATIONS. D N ® o O 4193SN Serial Interface 6 ' X 0.00015 = 0.0009 x - SUM COLUMN FOR STANDBY LOAD : ' 0.20535 = AMPS X l °°0 c Alarm Load X cV) Number of Current Total Current L N 0 L © L M o f Device Type Devices (Amps) (Amps) 120VAC DEDICATED POWER VISTA128 Main FACP CPU 1 X 0.032 = 0.032 CONTROL PANEL (TYP) (TYP) (TYP) 6150 Keypad 1 . X' 0.1 = 0.1 i3 Smoke Detector with Sounder 3 . X' 0.025 = ' 0.075 TELEPHONE LINE — FIRE BELL N ,WP i4 COSMO Smoke/CO Detector wlSounder 6 X 0.04 = 0.24 TELEPHONE LINE — SECURITY OUTPUT IQ EOLR COSMO Interface Module 6 0.034 0.204 4193SN Serial Interface 6 X 0.00015 _ 0.0009 Outside Horn/Strobe 1 X� 0.212 = 0.212 DATA/COM KP 6160 SUM COLUMN FOR ALARM LOAD 0.8639 = AMPS RISER DIAGRAM OUTPUT KEYPAD Standby Load Required Standby Time in Hours Current (Amps) 0.20535 X 24 = 4.93 Alarm Load Required Alarm Time in Hours Current (Amps) (15 MINUTES) UJJ 0.8639 X 0.25 = 0,22 Add Standby and Alarm Load for Required Ampere Hour Battery 5,14 Ce Multiply by the Derating Factor of 1.2 LLJ Total Ampere Hours Required = 6,17 uJ z Minimum Battery Size Provided: 12AH PROJECT INFORMATION . � Q C) SEQUENCE OF Z J 463 BEAVER DAN c Li, UJ L Z VAIL COLORADO QOPERATIONS: ZzzZ o z N 0 J FIRE ALARM SYSTEM fmcnQQ 1-11I.7 VI J W Q m N w N m N o o Z 0_ w AHJ: VAIL FIRE & EMERGENCY SERVICES 0 W CO 0 Q 2 N 2 2 2 w co 7) w APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC F- W � o � o cno o1- . I owo OCCUPANCY: GROUP R 0 CO 0 DEVICE w cno No No QN Qo Q� USE: DUPLEX < Q - - zm zm zm DESCRIPTION I g o g o g o 0 a 0 o 0 o FIRE ALARM SYSTEM FOR DUPLEX. TWO SEPARATE SYSTEMS WILL BE m Q 1- 1- 1- 1- 1- 1- Qm acn < I INSTALLED, WITH TWO SEPARATE PERMITS. SYSTEMS WILL INCLUDE A NEW W 0 c SMOKE DETECTOR X X ADDRESSABLE FACP. COMBINATION SMOKE/HEAT DETECTORS WILL BE Q O < z INSTALLED IN SLEEPING ROOMS WITH SMOKE/HEAT/CO DETECTORS ON W 0 < CD HEAT DETECTOR X X STAIRWELL LANDINGS, WITHIN 15' OF FIREPLACES AND AREAS OUTSIDE OF CO J w CO SLEEPING ROOMS. A HEAT DETECTOR WILL BE INSTALLED IN THE MCS Q CL W CARBON MONOXIDE DETECTOR X X X X GARAGE. DETECTORS HAVE INTEGRAL SOUNDERS. A KNOX BOX WILL BE > p MOUNTED ON THE OUTSIDE OF THE HOME. THE SPRINKLER SYSTEM SPRINKLER WATERFLOW SWITCH X X X WILL BE MONITORED, SHEET DESCRIPTION: FIRE PROTECTION ENGINEER: COVER SHEET SPRINKLER TAMPER SWITCH X X DEBORAH SHANER, P.E., SHANER LIFE SAFETY DRAWN BY: DATE: PO BOX 1073, FRISCO, CO 80443 POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X PHONE: 970-409-9082 DLS 10/8/15 FAX: 970-797- 1898 SHEET#: OWNER SIDE FA-000