HomeMy WebLinkAboutA15-0091_FA000_1467736500.pdf of 0 LEGEND .• icr�o SYMBOL DEVICE MANUFACTURER/PART# MOUNTING Vail Fire&Emergency Services 07/05/16 FACP Honeywell Vista-128BPT Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox KP LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox OCombination Smoke & System Sensor i3 series 4WTA-B Heat Detector w/Sounder w/4193SN Addressable module 4" square box Combination Smoke and Oco CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box ® System Sensor 5601P Address Type of Device Level Description Heat Detector w/4193SN Addressable module 4" square box 001 MONITOR MODULE 1 SPRINKLER WATERFLOW zz 0 002 MONITOR MODULE 1 SPRINKLER TAMPER C❑ Cosmo Interface Module COSMOD4W H 003 SMOKE DETECTOR 2 OFFICE/BEDROOME 004 CO/SMOKE DETECTOR 2 MUDROOM co 005 'CO/SMOKE DETECTOR 2 RECREATION ROOM M 0 006 CO/SMOKE DETECTOR 3 LEVEL 3 HALLWAY ❑ Addressable Monitor Module 4193SN Addressable module z 0 007 SMOKE DETECTOR 3 SOUTH BEDROOM v,� 008 'CO/SMOKE DETECTOR 3 NORTH BEDROOM KB Knox Box w 009 CO/SMOKE DETECTOR 4 OUTSIDE GARAGE 010 CO/SMOKE DETECTOR 4 GREAT ROOM � 011 HEAT DETECTOR 4 GARAGE V Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox 012 COISMOKE DETECTOR 5 TOP OF STAIRS 013 CO/SMOKE DETECTOR 5 MASTER BEDROOM GENERAL NOTES: 014 1- 015 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER STANDARDS, o 016 FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. 017 - 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR FURTHER 018 INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, PROGRAMMING AND DEVICE o z 019 OPERATION. 020 021 coo w 022 O Z 023 rn t~ 0240 Q 025 026 *..or -a. . ® � 0) OI O r.:3 R L ;j •, U 027 ?.`: . - .; ., ;' ® BE 0 028 a�,* 10 ��;. t J 029 ®.o U 3523a; r)030 k �� o z ,,,,, : 031 : rr, .�W mill CL _ 032 . - 034 ' ) - ) 035 e- 036 037 I ) " 038 039 D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) 11/4.1. 040 X = 2-WIRE DATA, 2-#16AWG - NOTE: LEVEL WILL BE INCLUDED IN DEVICE ADDRESS DESCRIPTION. N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG L = 2-WIRE DATA CIRCUIT, 2-#16AWG KP = KEYPAD CIRCUITING, 4-#18AWG ro RISER NOTES: - Battery Calculations 1. REFER TO VISTA 128 INSTALLATION MANUAL FOR 7co oo Adernco Vista 128 FACP MORE INFORMATION. �. O Standby 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS EOL o Number of Current Total Current MANUFACTURERS SPECIFICATIONS. D N M:1 Device Type Devices (Amps) (Amps) % Main FACP CPU 1 X' 0.032 = 0.032 X d1. 0 O 6160 Keypad 1 X 0 04 = 0.04 0 13 Smoke Detector with Sounder 2 X 0.00005 = 0.0001 L,N L L X _ xO O i4 COSMO Smoke/CO Detectorw/Sounder 8 X 0.00005 = 0.0004 120VAC DEDICATED POWER VISTA128 c M m N COSMO Interface Module 8 X 0.022 = 0.176 CONTROL PANEL (TYP) (TYP) (TYP) o it 4193SN Serial Interface 5 X r 0.00015 = 0.00075 0_ u_ SUM COLUMN FOR STANDBY LOAD ' ' 0.24925 = AMPS TELEPHONE LINE - FIRE BELL N AWP Alarm Load TELEPHONE LINE - SECURITY OUTPUT EOLR Number of Current Total Current Device Type Devices (Amps) (Amps) Main FACP CPU 1 X' 0.032 = 0.032 6160 Keypad 1 X 0.1 = 0.1 DATA/COM KP 6160 13 Smoke Detector with Sounder 2 X 0.025 = 0.05 RISER DIAGRAM OUTPUT KEYPAD 14 COSMO Smoke/CO Detectorw/Sounder 8 X 0.04 = 0.32 COSMO Interface Module 8 X 0.034 0 272 41935N Serial Interface 5 X 0.00015 _ 0.00075 Outside Horn/Strobe 1 X' 0.212 _ 0.212 SUM COLUMN FOR ALARM LOAD 0.98675 = AMPS Standby Load Required Standby Time in Hours W Current (Amps) 0.24925 X 24 = 5.98 0- Alarm Load Required Alarm Time in Hours Current (Amps) (15 MINUTES) Cew 0.98675 X 0.25 = 0.25 PROJECT INFORMATION : Add Standby and Alarm Load for Required z Ampere Hour Battery 6.23 J 473 BEAVER DAV w Q Multiply by the Derating Factor of 1.2 SEQUENCE OF zw w = Total Ampere Hours Required = 7.47 OPERATIONS: N Q z 00 VAIL COLORADO co _ FIRE ALARM SYSTEM = co Minimum Battery Size Provided: 12AH J O p 0 cn O p M z Q U L1J 1Y E m N w u) m N o o Z a_ 1.,., AHJ: VAIL FIRE & EMERGENCY SERVICES n2 Dz o z uj m - 7) w0 APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC � � U Q Ft N Ft 1- Ft w Q 1503 (n o (n o (n o O l- U I o 0 OCCUPANCY: GROUP R w CO w mz mz � z w I w w ' 0 w USE: DUPLEX 0 DEVICE 1-, zM zM zM aN Qz Q� DESCRIPTION a ¢ a N a ,o , o , o a m a o F.A. FIRE ALARM SYSTEM FOR DUPLEX. TWO SEPARATE SYSTEMS WILL BE 0 < (f) � � � � � � � INSTALLED, WITH TWO SEPARATE PERMITS. SYSTEMS WILL INCLUDE A NEW CO SMOKE DETECTOR X X ADDRESSABLE FACP. COMBINATION SMOKE/HEAT DETECTORS WILL BE w 0 o 0 INSTALLED IN SLEEPING ROOMS WITH SMOKE/HEAT/CO DETECTORS ON > 0 J z X X HEAT DETECTOR STAIRWELL LANDINGS, WITHIN 15' OF FIREPLACES AND AREAS OUTSIDE OF w 0 < SLEEPING ROOMS. A HEAT DETECTOR WILL BE INSTALLED IN THECO X X X X GARAGE. DETECTORS HAVE INTEGRAL SOUNDERS. A KNOX BOX WILL BE J W (J) CARBON MONOXIDE DETECTOR MOUNTED ON THE OUTSIDE OF THE HOME. THE SPRINKLER SYSTEM ti Q - w SPRINKLER WATERFLOW SWITCH X X X WILL BE MONITORED, ' > LI- 0 FIRE PROTECTION ENGINEER: SHEET DESCRIPTION: SPRINKLER TAMPER SWITCH X X DEBORAH SHANER, P.E., SHANER LIFE SAFETY COVER SHEET PO BOX 1073, FRISCO, CO 80443 POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X PHONE: 970-409-9082 DRAWN BY: DATE: FAX: 970-797- 1898 DLS 10/8/15 SHEET#: SPEC SIDE FA-000