Loading...
HomeMy WebLinkAboutA15-0094_Ademco VISTA-128BPBPE_1445271060.pdf Honeywell VISTA- 128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS II, - foli t� ��s. ,'RAR The VISTA-128BPE is a powerful member of the Honeywell The VISTA-128BP and VISTA-128BPE(VISTA-128BP Rev.4) family of commercial alarm panels, integrating burglary, CCTV are Listed for residential burglary, residential fire and commercial and access control functions. Many features are available that burglary applications(see agency listings in this document for extend the applications of the VISTA-128BP while simplifying more details).They are compatible with a wide range of end-user operation. AlarmNet communications products for alarm reporting, uploading/downloading and remote services. FEATU RES Standard features • Zone 7 may be used for keyswitch • Scheduled check-in (VISTA-128BP and VISTA-128BPE): arming/disarming • Arm stay by group • Provides nine style-B hardwired zones • Supports V-Plex® addressable VistaKeyaccess control (upto eight Enhanced features • Supports up to 119 additional zones (VISTA-128BPE only): using a built-in polling (V-Plex, doors and 250 cards) multiplex)loop interface • Easily programmed and maintained • Carbon monoxide(CO)zone • Supports up to 127 wireless zones by Compass Windows-based type support using up to two 5800 series wireless downloader • Expanded RS-232 capability receivers (fewer if using hardwire • Supports up to 96 programmable for third party interface and and/or polling loop zones) outputs automation • Provides one power-limited bell circuit • Programmable to meet SIA false • Internet upload/download over delivering 1.7Amp (max)at 12Vdc alarm prevention specifications. AlarmNet GSM, iGSM and IP • Provides the ability to control eight To meet UL approval for ANSI/SIA communicators over the panel's separate partitions independently, CP-01-2000 order part number keypad (ECP)bus each functioning as if it had its own VISTA-128SIA • Ringback support for AlarmNet separate control • Panel Linking up to eight panels communicators(confirmation of • Accommodates 150 user codes with closing report) • Supports eight numeric seven authority levels pager numbers • 24-hour dialer test support for AlarmNet devices • Accommodates 32 keypad macro • Supports touchscreen Advanced commands per system User Interface(AUI) • Keeps a log of up to 512 events • Smoke detector reset at keypad • VistaView-100 CCTV support • Quick exit • Supports up to 16 compatible two- • Group bypass wire smoke detectors on zone 1 • Arm faulted • Supports up to 50 latching-type • Event arming glassbreak detectors on zone 8 Honeywell VISTA- 128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ADDITIONAL FEATURES Basic Hardwired Zones • Tamper protection for supervised • A Master partition(9), used strictly to Provides nine style-B hardwired zones transmitters assign keypads for the purpose of with the following characteristics: • Individually assignable to one of viewing the status of all eight partitions • EOLR supervision (optional for zones eight partitions at the same time(master keypads) 2-8)supporting N.O. or N.C. sensors Scheduling • All zones assignable to one of (EOLR supervision required for fire Provides the following scheduling eight partitions and UL burglary installations) capabilities: • Keypads assignable to one of eight • Individually assignable to one of • Open/close schedules (for control of partitions or to Master partition 9 to eight partitions arming/disarming and reporting) view system status PollingLoopExpansion • Ability to assign relays to one or all p Holiday schedules(allows different Supports up to 119 additional zones time windows for open/close eight partitions using a built-in polling (V-Plex, multiplex) schedules) • Ability to display fire and/or burglary loopinterface. Current draw can totaland panic and/or trouble conditions • Timed events (for activation of relays, up to 128mA. Polling loop zones have auto-bypassing and unbypassing, at all other partitions' keypads the following characteristics: (selectable option) auto-arming and disarming, etc.) • Must use V-flex devices • Access schedules (for limiting system • Individually programmable account • Supervised by control panel access to users by time) number, entry delay and exit delay by partition • Individually assignable to one of • End user output programming mode eight partitions (provides 20 timers for output control) Wireless Expansion Eight Partitions Supports up to 127 wireless zones Provides the ability to control eight using up to two 5800 series wireless separate areas independently, each receivers(fewer if using hardwire functioning as if it had its own separate and/or polling loop zones). control. Partitioning features include: Wireless zones have the following • A Common Lobby partition (1-8), characteristics: which can be programmed to arm • Supervised by control panel for automatically when the last partition check-in signals (except certain that shares the common lobby is non-supervised transmitters) armed, and to disarm when the first partition that shares the common lobby is disarmed I1 = I V-Plex Loop . 1 3 I I I .....4,. _I FG1625SN Glassbreak 4208U Eight-zone 5193 4101SN DT7500SN Expansion Module and 4293SN Adapters Series Smoke Detectors Relay Module V-Plex DUAL TEC 4208EX Eight-zone Motion Sensor V-Plex Expander 5881 ECP Bus Wireless Receiver ---J 6160 ._ . Console gh Parallel Printer RS-232 LightIiii Notification ' • PliR4204 1 Appliances Keyswitch -- Module Serial Printer Y� ° Option 7.as-1.- .-- 4146 1 ' I > Phone Line to Central Station ., 748 Horn Alpha Paging .•.. —or— —or-- -- Module I 7847i GSM iGSM NOTE:Please refer to the website(www.honeywell.com/security/hsc)for the latest product information. Honeywell VISTA- 128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ACCESSORIES Auxiliary Devices • 5193SD Wireless Devices • 4204- Relay Module, four form C • 5193SDT • 5804- Wireless Key contacts Passive Infrared Detectors • 5804BD- Bidirectional Key • 5881 Series RF Receiver supporting • 998MX • 5804BDV- Bidirectional with voice 5800 wireless detectors • 6160 Alpha Keypad/Annunciator • IS2500SN • 5816- Door/Window Transmitter • 6220S- System Printer used with • DT7500SN • 5819 Shock Sensor 4100SM serial module • QUEST2260SN • 5827BD- Bidirectional Keypad • VA8200- (PLM)Panel Linking Module V-Plex(Addressable)Contacts • 5853- Glassbreak Detector • VA8201 - (APM)Alpha Paging Module • 4939SN-WH • 5894- Wireless PIR Motion Sensor Manual Pull Stations • 4944SN-WH • 5890- Passive Infrared Detection • 5140MPS-1 • 4959SN, 9500SN • 5800PIR-OD- Outdoor • 5140MPS-2 V-Plex Glassbreak Detectors Motion Sensor •V-Plex(addressable) Devices • FG1625SN 5870API Asset Protection Device •• 4101SN Single Relay/zone Module VISTA Interactive Phone Module 5800—Wireless RES/Detect Detectors Motion Detectors • 4190SN Remote Point Module- • 4286 VIP Module • 580000/A Wireless Carbon two zones Optional Communicators Monoxide Detector • 4193SN Two zone Serial Interface • AlarmNet Internet/Intranet • 5800RP-Wireless Repeater Module communicators and digital cellular •• 4208EX- Eight zone expander for communicators 5808W3 Wireless Smoke Detector ULC commercial installations Access Control • 5809- Wireless Heat Detector • 4208U Loop Expansion Module • VISTAKey V-Plex(addressable) Commercial Listed eight zones Access Control Wireless Devices • 4209U Group zoning Module • VISTAKey-SK Starter Kit • 5817CB- Commercial UL Burglary, two/four zones Universal Contact Monitoring • 4293SN One zone Serial Interface • VISTAKey-EX Expansion Kit Transmitter* Module • 5869- Commercial UL Wireless • 4297 Isolation/Extender Module V-Plex CCTV Hold-up Button* (addressable)smoke detectors • Optiflex CCTV module • 5881 ENHC and 5883H Receivers • VSI Short/Overload Isolation Module *When used with 5881ENHC and/or 5883H receiver. , a�' MJ 4190SN 4959SN 4944SN IS2500SN 4208U 4193SN Remote Point Module Overhead Door Contact Contact VISTAKey V-flex V-flex PIR Eight-zone Serial Interface Module Access Control Motion Sensor Expansion Module 5808W3 Module 5881ENHC Wireless Glassbreak Detectors 11111/ Commercial Wireless(MaxoSmoke ECP Bus Max Two) — Detector 5800 Series 5890 ' Wireless — "W= 6160 5816 Devices Wireless PIR Console Door/Window -- Transmitter I ` ,...Jimori4209U .� � `� Group Zoning �, �, Module ,1.0114,5869 Commercial UL- I Supports Up To L 51, 4204 Wireless Hold-up 5817CB Universal 16 Conventional ._ Relay 4204CF Button Contact Monitoring Two-Wire Module Supervised Smoke Detectors 4111.IN' • NAC Module Transmitter iirmato Panel Linking Module Panel Linking Module VISTA- 128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS SPECIFICATIONS Agency Listed to the Electrical Main Dialer Following Standards: • Voltage Input: From Honeywell No. • Formats Supported: ADEMCO • UL609 Grade A Local Mercantile 1361 Plug-In Transformer or Contact ID, ADEMCO High Speed, Premises and Mercantile Safe 1361X10 transformer(for X-10 ADEMCO 4 + 2 Express, ADEMCO and Vault installations)rated 16.5VAC,40 VA Low Speed, Sescoa and Radionics • UL611/UL1610 Grades A, AA • Use 1361CN plug-in transformer Low Speed Central Station for Canada • Line Seize: Double Pole • UL365 Grades A, AA Police Connect • Alarm Sounder Output: 10VDC- • Ringer Equivalence: 0.7B • UL985 Household Fire 13.8VDC, 1.7 amps max., (UL1023, Cabinet Dimensions UL609 installations); 750mA less aux. • UL1023 Household Burglar Alarm current draw (UL985 installations) 12-1/2"W X 14 1/2" H X 3" D California State Fire Marshall (CSFM) • UL1635 Digital Alarm • Auxiliary Power Output: 9.6VDC- Communicator System Units 13.8VDC, 750mA max. For UL installations, the accessories • CAN/ULC- S303 connected to the output must be UL • CAN/ULC- S304 Listed, and rated to operate in the • CAN/ULC- S545 above voltage range • CAN/ULC- S1023 • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid. YUASA NP4-12 • For commercial burglary attack proof (12V, 4AH)or NP7-12 (12V, 7AH) requirements, use VISTA-ULKT attack recommended proof enclosure • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). ORDERING VISTA-128BP Commercial Burglary Alarm Control Panel (UL Listed) VISTA-128BPE Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending) VISTA-128SIAE SIA Approved Enhanced Commercial Burglary Alarm Control Panel For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications 2 Corporate Center Dr. Suite 100 Honeywell P.O. Box 9040 Melville, NY 11747 UVSTA128BPD/D 1.800.467.5875 April 2010 www.honeywell.com ©2010 Honeywell International Inc.