Loading...
HomeMy WebLinkAboutA15-0100_A15-0100 Data Sheets_1447091640.pdf Honeywell VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS iii4 , , The VISTA-128BPE is a powerful member of the Honeywell The VISTA-128BP and VISTA-128BPE(VISTA-128BP Rev.4) family of commercial alarm panels, integrating burglary, COW are Listed for residential burglary, residential fire and commercial and access control functions. Many features are available that burglary applications(see agency listings in this document for extend the applications of the VISTA-128BP while simplifying more details).They are compatible with a wide range of end-user operation. AlarmNet communications products for alarm reporting, uploading/downloading and remote services. FEATURES Standard features •Zone 7 may be used for keyswitch •Scheduled check-in (VISTA-128BP and VISTA-128BPE): arming/disarming •Arm stay by group • Provides nine style-B hardwired zones • Supports V-Plex®addressable • Supports up to 119 additional zones VistaKey access control (up to eight Enhanced features using a built-in polling (V-Plex, doors and 250 cards) (VISTA-128BPE only): multiplex) loop interface • Easily programmed and maintained • Carbon monoxide(CO)zone • Supports up to 127 wireless zones by Compass Windows-based type support using up to two 5800 series wireless downloader • Expanded RS-232 capability receivers(fewer if using hardwire • Supports up to 96 programmable for third party interface and and/or polling loop zones) outputs automation • Provides one power-limited bell circuit • Programmable to meet SIA false • Internet upload/download over delivering 1.7Amp(max)at 12Vdc alarm prevention specifications. AlarmNet GSM, iGSM and IP • Provides the ability to control eight To meet UL approval for ANSI/SIA communicators over the panel's separate partitions independently, CP-01-2000 order part number keypad (ECP) bus each functioning as if it had its own VISTA-128SIA • Ringback support for AlarmNet separate control • Panel Linking up to eight panels communicators(confirmation of closing report) •Accommodates 150 user codes with • Supports eight numeric •24-hour dialer test support for seven authority levels pager numbers pp •Accommodates 32 keypad macro • AlarmNet devices YpSupports touchscreen Advanced commands per system User Interface(AUI) • Keeps a log of up to 512 events • Smoke detector reset at keypad •VistaView-100 CCTV support • Quick exit • Supports up to 16 compatible two- • Group bypass wire smoke detectors on zone 1 •Arm faulted • Supports up to 50 latching-type • Event arming glassbreak detectors on zone 8 Honeywell VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ADDITIONAL FEATURES Basic Hardwired Zones •Tamper protection for supervised •A Master partition (9), used strictly to Provides nine style-B hardwired zones transmitters assign keypads for the purpose of with the following characteristics: • Individually assignable to one of viewing the status of all eight partitions • EOLR supervision (optional for zones eight partitions at the same time(master keypads) 2-8)supporting N.O. or N.C. sensors Scheduling •All zones assignable to one of (EOLR supervision required for fire Provides the following scheduling eight partitions and UL burglary installations) capabilities: • Keypads assignable to one of eight • Individuallyassignable to one of partitions or to Master partition 9 to g Open/close schedules(for control of eight partitions arming/disarming and reporting) view system status Polling Loop Expansion • Holiday schedules(allows different •Ability to assign relays to one or all Supports up to 119 additional zones time windows for open/close eight partitions using a built-in polling (V-Plex, multiplex) schedules) •Ability to display fire and/or burglary loopinterface. Current draw can total and panic and/or trouble conditions Timed events(for activation of relays, up to 128mA. Polling loop zones have auto-bypassing and unbypassing, at all other partitions' keypads the following characteristics: auto-arming and disarming, etc.) (selectable option) • Must use V-Plex devices • • Individually programmable account Access schedules(for limiting system number, entry delay and exit delay by • Supervised by control panel access to users by time) partition • Individually assignable to one of • End user output programming mode eight partitions (provides 20 timers for output control) Wireless Expansion Eight Partitions Supports up to 127 wireless zones Provides the ability to control eight using up to two 5800 series wireless separate areas independently, each receivers(fewer if using hardwire functioning as if it had its own separate and/or polling loop zones). control. Partitioning features include: Wireless zones have the following •A Common Lobby partition (1-8), characteristics: which can be programmed to arm • Supervised by control panel for automatically when the last partition check-in signals(except certain that shares the common lobby is non-supervised transmitters) armed, and to disarm when the first partition that shares the common lobby is disarmed I I_ I . ______77,--..: V PIex Loop s FG1625SN Glassbreak 4208U Eight-zone 11.111.65 5193 4101 SN DT7500SN Expansion Module and 4293SN Adapters Series Smoke Detectors Relay Module V-Plex DUAL TEC 4208EX Eight-zone Motion Sensor V-flex Expander 5881 ECP Bus I Wireless 1 Receiver ii • 6160 • Console 710 ............ Light ;. Parallel Printer RS-232IN= 4204 litNotification Relay Appliances • KOption Module Serial Printer Option 4146 /MUM ilt C I > Phone Line to Central Station 748 I { Horn JI Alpha Paging 1=1 —or— or- Module - 78471 GSM iGSM NOTE:Please refer to the website(www.honeywell.com/security/hsc)for the latest product information. Honeywell VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ACCESSORIES Auxiliary Devices • 5193SD Wireless Devices • 4204 - Relay Module, four form C • 5193SDT • 5804 -Wireless Key contacts Passive Infrared Detectors • 5804BD- Bidirectional Key • 5881 Series RF Receiver supporting • 998MX • 5804BDV- Bidirectional with voice 5800 wireless detectors • 6160 Alpha Keypad/Annunciator • IS2500SN • 5816 - Door/Window Transmitter • 6220S -System Printer used with • DT7500SN • 5819 -Shock Sensor 4100SM serial module • QUEST2260SN • 5827BD- Bidirectional Keypad •VA8200 - (PLM) Panel Linking Module V-Plex(Addressable)Contacts • 5853 -Glassbreak Detector •VA8201 - (APM)Alpha Paging Module • 4939SN-WH • 5894 -Wireless PIR Motion Sensor Manual Pull Stations • 4944SN-WH • 5890 - Passive Infrared Detection • 5140MPS-1 • 4959SN, 9500SN • 5800PIR-OD -Outdoor • 5140MPS-2 V-Plex Glassbreak Detectors Motion Sensor V-Plex(addressable) Devices • FG1625SN • 5870API Asset Protection Device • 4101 SN Single Relay/zone Module VISTA Interactive Phone Module • COM—Wireless RE Motion Detectors COM—Wireless Detectors • 4190SN Remote Point Module- • 4286 VIP Module • 580000/A Wireless Carbon two zones Optional Communicators Monoxide Detector • 4193SN Two zone Serial Interface •AlarmNet Internet/Intranet • 5800RP-Wireless Repeater Module communicators and digital cellular • 4208EX- Eight zone expander for communicators • 5808W3 Wireless Smoke Detector ULC commercial installations Access Control • 5809 -Wireless Heat Detector • 4208U Loop Expansion Module •VISTAKey V Plex(addressable) Commercial Listed eight zones Access Control Wireless Devices • 4209U Group zoning Module .VISTAKey SK Starter Kit • 5817CB- Commercial UL Burglary, two/four zones Universal Contact Monitoring • 4293SN One zone Serial Interface •VISTAKey-EX Expansion Kit Transmitter* Module • 5869 -Commercial UL Wireless • 4297 Isolation/Extender Module V-Plex CCTV Hold-up Button* (addressable)smoke detectors • Optiflex CCTV module • 5881 ENHC and 5883H Receivers •VSI Short/Overload Isolation Module *When used with 5881 ENHC and/or 5883H receiver. , ,c.i.,„sr:t1 .. 1 III L__ 7.1. 71 6-5-0 • 4190SN 4959SN 4944SN IS2500SN 4208U 4193SN Remote Point Module Overhead Door Contact Contact VISTAKey V-Plex V-Plex PIR Eight-zone Serial Interface Module Access Control Motion Sensor Expansion Module 5808W3 Module 5881ENHC Wireless Glassbreak Detectors Commercial Wireless Receiver SmokeECP Bus (Max Two) Detector 5800 SeriesWireless — 58901111H WWII 6160 5816 Devices Wireless PIR Console Door/Window - [- Transmitter 71 / I `.�------, —�- 4209U �� GroModuleing 5869 Commercial UL4-,,,p OP IM14. Supports Up To !1� r 4204 Wireless Hold-up 5817CB Universal v� 16 Conventional -— Relay 4204CF Button Contact MonitoringTwo-etec � Module Supervised Smoke Detectors PI NAC Module Transmitter _ m lilli Panel Linking Module Panel Linking Module VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS SPECIFICATIONS Agency Listed to the Electrical Main Dialer Following Standards: •Voltage Input: From Honeywell No. • Formats Supported:ADEMCO • UL609 Grade A Local Mercantile 1361 Plug-In Transformer or Contact ID, ADEMCO High Speed, Premises and Mercantile Safe 1361X10 transformer(for X-10 ADEMCO 4+2 Express,ADEMCO and Vault installations)rated 16.5VAC,40 VA Low Speed, Sescoa and Radionics • UL611/UL1610 Grades A, M • Use 1361CN plug-in transformer Low Speed Central Station for Canada • Line Seize: Double Pole • UL365 Grades A,M Police Connect •Alarm Sounder Output: 10VDC- • Ringer Equivalence: 0.7B • UL985 Household Fire 13.8VDC, 1.7 amps max., (UL1023, Cabinet Dimensions UL609 installations); 750mA less aux. • UL1023 Household Burglar Alarm current draw(UL985 installations) 12-1/2" W X 14 1/2" H X 3" D California State Fire Marshall (CSFM) • UL1635 Digital Alarm •Auxiliary Power Output: 9.6VDC- 13.8VDC, 750mA max. For UL Communicator System Units installations,the accessories • CAN/ULC -S303 connected to the output must be UL • CAN/ULC -S304 Listed, and rated to operate in the • CAN/ULC -S545 above voltage range • CAN/ULC -S1023 • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid.YUASA NP4-12 • For commercial burglary attack proof (12V, 4AH)or NP7-12(12V, 7AH) requirements, use VISTA-ULKT attack recommended proof enclosure • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts).A solid state circuit breaker is used on auxiliary power output to protect against wiring faults(shorts). ORDERING VISTA-128BP Commercial Burglary Alarm Control Panel (UL Listed) VISTA-128BPE Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending) VISTA-128SIAE SIA Approved Enhanced Commercial Burglary Alarm Control Panel For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications 2 Corporate Center Dr. Suite 100 Honeywell P.O. Box 9040 Melville, NY 11747 1.800.467.5875 L ISTA128BPD/D April 2010 www.honeywell.com ©2010 Honeywell International Inc. ****DISARMED**** READ1 TO IRM 6160 �- ALPHA DISPLAY KEYPAD H� READY TO PPM • WITH DOOR ATTACHED 1 ri7M- Mr r - I .1� 15. 18+.r .. ....- Iv— *.... -•.. la I ...- WITHOUT DOOR The 6160 Deluxe Keypad is easy to install and simple to The oversized function keys are easily accessed even when use. The attractive white console blends with any decor and the keypad door is closed, and can be programmed for fire, features a contoured, removable door that conceals burglary, personal emergencies and other operations. Colored illuminated soft-touch keys.The 6160 also features a new self-adhesive labels are included. larger and brighter 32-character display with easy-to-read plain-English status messages. FEATURES • Large, easy-to-use keypad •Zones and system events displayed •System functions clearly labeled • Keys continuously backlit for greater in plain English • Functions performed by just entering visibility • No confusing blinking lights security code plus command • Speaker with audible beeps • Four programmable function keys •White with removable door blends to indicate: with any decor -System status - Entry/exit delay -Other alarm situations SPECIFICATIONS Physical Wiring Compatibility • 5-5/16"H x 7-3/8"W x 1-3/16"D • - (Black): Ground • Fully compatible with all (135mm x 190mm x 30mm) VISTA controls. • +(Red): +12 VDC (Aux. Power) Current • D1 (Green): "Data in"to control panel • Standby 40mA • DO(Yellow):"Data out"from •Activated Transmission-160mA control panel ORDERING 6160 Alpha Display Keypad Honeywell Security&Custom Electronics Honeywell Honeywell International Inc. PO Box 9035 COo6o10 Syosset, NY 11791 U6160/D September 2006 www.honeywell.com ©2006 Honeywell International Inc. Honeywell 5193S D/5193S DT V-PLEX® ADDRESSABLE SMOKE DETECTOR LI 7 IP # Honeywell's 5193SD/SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL-listed Honeywell control panels that support V-Plex technology.The detector incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit's chamber. The 5193SDT also features a restorable, built-in, fixed temperature(135° F/57.2° C)thermal detector. FEATURES • Easy Installation: Installation of the 5193SD/SDT detector •Versatile Mounting: Mounting is made simple with the is simplified by the use of a mounting base that may be included hardware and the large mounting ports, which pre-wired to the system, allowing the detector to be easily accommodate drywall anchors for easy surface mounting. installed or removed for maintenance or service. (See (See Figure 1). Figure 1). •Tamper Protection and Tamper Resistance:The detector • LED Status Indicators:Two LEDs(green and red) provide contains a built-in tamper switch that can communicate local visual indication of the detector's status—including back to the control panel in the event the detector is normal operation, alarm, out of sensitivity and trouble removed from its base. For an added level of security, conditions. the detector also includes a tamper resistant element that •Test button:This button allows the user to perform periodic prevents removal from the base without the use of tools. testing of the detector's circuitry and verify that the detector (See Figure 1). is within the sensitivity limits. DIRECT MOUNT HOLES ...,� , 111' 1_` ,�rrJ • SNAP OFF TAB FOR TAMPER LOCK TAMPER RELEASE TAB Figure 1:Tamper-Resistant Feature/Wiring 5193S D/5193S DT V—PLEX® ADDRESSABLE SMOKE DETECTOR SPECIFICATIONS • Heat Sensor: (Model 5193SDT): • Diameter(including base): 5.3 inches 135° F(57.2° C); Fixed Temperature Electronic Thermistors • Height(including base): 2.0 inches • Weight: 6.3 oz. • Operating Ambient Temperature Range: 32°to 100° F(0°to 38° C) • Agency Listing: UL-268 • Operating Humidity Range: • System Voltage Range: 7-14V 0 to 95% RH non-condensing • Standby Current(maximum @ 12V) • Storage Temperature Range: LED off: 1.2mA -4°to 158° F(-20°to 70°C) LED on: 2.8mA ACCESSORY(sold separately) To measure the detector's sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately) should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. \n�T7 • Mir • 411 - If Figure 2: Position of Reader .8 ORDERING 5193SD Addressable Photoelectric Smoke Detector 5193SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor Accessory sold separately: SENS-RDR Handheld Sensitivity Reader Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 ve193sDTio May 2009 www.honeywell.com ©2009 Honeywell International Inc. Honeywell 580000 CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER 0 0 J0 415 The 580000 is a 3V battery powered wireless carbon The detector consists of an electrochemical carbon monoxide(CO) detector intended for use with Honeywell monoxide sensor assembly coupled with a wireless alarm systems that support 5800 Series wireless devices. transmitter. The transmitter can send alarm, trouble, It provides early warning when its electrochemical sensing end-of-life, tamper and low battery condition messages technology measures carbon monoxide levels in the air. to the alarm panel. The 580000 is specifically designed for system operation Since there are no holes to drill or wires to run, you can and is fully listed to UL 2075 as a system supervised preserve the beauty of the home or building while detector.* It contains a piezoelectric horn which generates protecting its occupants from harmful carbon monoxide the ANSI S3.41 temporal 4 pattern in an alarm condition. gas. The 580000 is an ideal carbon monoxide detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist. What is Carbon Monoxide and How Can it Harm Consumers? Carbon monoxide(CO) is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels such as wood, gasoline, charcoal and oil are burned with insufficient air. The majority of residential and commercial fatalities caused from these fuels come from heating systems, engine powered tools and charcoal grills. Carbon monoxide is harmful when inhaled because it displaces oxygen in the blood and deprives the heart, brain and other vital organs of oxygen. Large amounts of CO can overcome a person in minutes without warning—causing them to lose consciousness and suffocate. The 580000 is designed to warn the end-user well before the CO reaches a fatal level. The detector's CO sensitivity is evaluated to UL 2034. CO Levels and Time to Alarm CO Concentration Min.Time to Alarm Max.Time to Alarm 30 ppm +/- 5 ppm 30 days Indefinite** 70 ppm +/- 5 ppm 60 minutes 240 minutes 150 ppm+/- 5 ppm 10 minutes 50 minutes 400 ppm+/- 5 ppm 4 minutes 15 minutes *For a complete list of products that support system operation of the 580000 to UL standard 2075, please visit: www.honeywell.com/security/hsc/resources/agency/co **Life of product 580000 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER KEY FEATURES Electrochemical Sensing Technology- Electrochemical Full Supervision -The 580000 is fully supervised to monitor detectors are the newest, most refined CO detectors available for low battery, case tamper and trouble conditions. and provide the most accurate measurement of CO Test/Hush Button -This dual purpose button allows the concentration obtainable.They can take readings from low end-user to perform periodic testing of the detector. In the levels that may be hazardous over long periods of time to event of a CO alarm, this button will silence the local sounder high concentrations that present an immediate danger. alarm for a five minute period. Note:the Hush feature will not Local Sounder-A built-in piezoelectric horn generates the operate at levels above 350 ppm (parts per million)carbon ANSI S3.41 temporal 4 pattern in an alarm condition.The monoxide (see figure 1). local sounder will also alert the end-user of other conditions Versatile Mounting -Whether you choose to affix the such as low battery, detector trouble and end-of-life. detector to the ceiling or a wall, mounting is made simple LED Status Indicators- Dual LEDs provide local visual with the enclosed hardware. The mounting base has large indication of the detector's status—including normal operation, mounting ports, which accommodate drywall anchors for alarm, low battery, trouble and end-of-life (see figure 1). easy surface mounting (see figure 2). End of Life Timer-When the detector has reached the end Tamper Protection and Tamper Resistant Element- of its life, the detector will send a trouble signal to the panel. The detector has a built-in tamper switch that can This indicates that the CO sensor inside the detector has communicate back to the control panel in the event it is passed the end of its life and the detector needs to be removed from the base. For an added level of security, replaced.The detector's lifespan is approximately six years the detector also includes a tamper resistant element that from the date of manufacture. prevents removal from the base without the use of a tool (see figure 2). MOUNTING --------..\ SCREWS A (INSTALLED) �t, v \\ :::IIii7I! iii \ \>y 'jSy (::1 moo Zordiligilliiir4"*°:0_, o`o B o Z , „¢ag L ACTIVATE \\ SRM �QPe ®� : -��� TAMPER RESIST D.0,''' go, o o FEATURE) RED LED f / OP � ENGAGE NOTCH WITH TAMPER RELEASE TAB ON BASE AND TURN CLOCKWISE TO LOCK Figure 1 Figure 2 580000 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER MOUNTING RECOMMENDATIONS CO is slightly lighter than air and when heated by a fuel-burning source, the lighter weight and warm temperature of the CO causes it to quickly rise to the ceiling and mix freely with the air. Check with the local Authority Having Jurisdiction (AHJ)for CO detector requirements in your area. Some recommendations for installing the 580000 are as follows: - On every floor of the facility - Inside any areas that contain a fuel-burning appliance - In the vicinity of flame-fueled appliances, but no closer than 10 feet / ■ 6 • For wall mount BEDROOM - The detector should be at least as high as a light switch and at least six inches from the ceiling To BEDROOM BR BEDROOM • For ceiling mount ■ KITCHEN GARAGE - The detector should be at least 12 inches from CLOSED LIVING DOOR any wall ROOM MIN • CARBON MONOXIDE ALARM LOCATION FOR MULTI-LEVEL RESIDENCE SPECIFICATIONS • Power Source: One 3V CR123A lithium battery (included) • Audible Signal (temporal 4 tone): 85 dB in alarm (at 10 ft.) • Height: 2.3" (58mm) • Diameter: 5.3" (135mm) with mounting base • Weight: 7 oz. (241 g)without battery • Operating Ambient Temperature Range: 32° F to 100° F(0° C to 37.8° C) • Operating Humidity Range: 15%to 95% relative humidity, non-condensing • Agency Listings: - Listed to UL standard 2075, "CO sensitivity is evaluated to UL 2034 - 580000A ULC Listed - tested to the CAN/CSA 6.19.01 standard ORDERING 580000 Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter 580000A Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter with ULC listing "For a complete list of products that support system operation of the 580000 to UL standard 2075 and 580000A ULC standard, please visit: www.honeywell.com/security/hsc/resources/agency/co Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 March2o9/D 2009 www.honeywell.com ©2009 Honeywell International Inc. SYSTEM �$ SENSOR (011111 . -\\ 5600 Series Mechanical • . . Heat Detectors \r--- 4 System Sensor's 5600 series mechanical heat detectors i offer a low-cost means for property protection against fire,and for non-life-safety installations where smoke �I detectors are inappropriate. ' Features Multiple configurations.The 5600 series offers a full-line of •Multiple configurations for installations: configurations to accommodate a broad range of applications.Both -Single and dual circuit models single-and dual-circuit models are available for low-and high- -Fixed temp and combination fixed temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. •Plain housing for residential installations(Model 5601 P) •Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, •Abroad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back -Single gang boxes.And these models accommodate four-square back boxes, -3.5"and 4"Octagonal when used with a square to round plaster ring.The reversible -4"square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. •Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings 13 ® MEA LISTED APPROVED approved S2101 3016008 199-03-6 7270-1209227 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90°C),and shall activate by means of a fixed temperature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature,approximately 15°F(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601 P,5603,5621,and 5623:100°F(38°C) 5602,5604,5622,and 5624:150°F(65.6°C) Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601 P,5603,5621,and 5623:135°F(57°C) 5602,5604,5622,and 5624:194°F(90°C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 15°F(8.3°C)rise per minute(models 5601P,5602,5621,and 5622 only) Mounting 31/-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact Ratings 6-125VAC/3A 6-28VDC/1 A 125VDC/0.3A 250VDC/0.1 A Input Terminals 14-22 AWG aonik x.1aowxi— '''''s0 11 ----'—''' o o 0 0 ) , 1,.. „,„.,,,,,,‘ ., /.///.. .\\,„ I , . . . . ,,,,,__ _ ____ ---- Iiia Y 3 fit taiklY i 5601P 5602,5622 5603,5623 5604,5624 5621 Ordering Information Identification Method Temperature Model Circuit on Exterior Rating Activation UL Protected Spacing-10 Foot Ceiling* 5601 P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. *Th_ SYSTEM m2006 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Usit systemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0351-002.11/06•#1676 , SYSTEM �$ SENSOR 7:-..-.r __ ,... .._ _ _ , . , ., .,. .. Mini-HornsThe SpectrAlertt Advance series of mini-horn sounders aredesigned to simplify installations to provide primary andsecondary signaling for fire and security applications. SPECTRIert A N C Features The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications,where a • 12 and 24V operation smaller notification device is desired.The mini-horns offer high and • High and low volume settings low volume settings,and temporal or non-temporal tones. The horns • Temporal and non-temporal tones can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the • Mounts to single gang back box MDL module. • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-AlertTM sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories • Listing for ceiling or wall mounting Standard UL 464 for fire protective signaling systems. Agency Listings U` ots,:- OA ® LISTED APPROVED S4011 3028007 CS1C93 7135-1653:196 SpectrAlert®Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini-horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.When used with the Sync•Circuit° Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9"W x .45"D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:deep single-gang back box(23/4"deep) Flush:Standard 4"x 4"back box with single gang mud ring,which allows sufficient clearance for conduit entrance. Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output(dBA) Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 Nominal 12 16-33 16-33 VDC VFWR VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High 72 71 75 74 80 79 temporal 4 Non- Low 70 69 73 72 78 77 temporal Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini-Horn,Red MHW Mini-Horn,White $T SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensotcom �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01500.3/12