HomeMy WebLinkAboutA15-0101_FA000P_1447969260.pdf t1 Cir I/4 LEGEND : SYMBOL 1 DEVICE MANUFACTURER/PART# MOUNTING0 ,s' Honeywell Vista-128BPT 'V'' =-''k/` N FACP y at`�;�itlG/ '�• ` •s Vail Fire &Emergency Services .4: � Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox ;s r,'F 11/19/15 KP • O:�, 352331 P40 Z - LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox _„f i,::wf 0 Smoke Detector Honeywell 5193SD 4" square box t4ONA.•".'' z ® System Sensor 5601P o Heat Detector w/4193SN Addressable module 4" square box U H❑ Sounder System Sensor MHW Single gang box o z 0 i-n Co Carbon Monoxide Detector Honeywell 580000 Single gang box w Lt 111 Knox Box ' Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox w I- 0 GENERAL NOTES: 3 #16 PAIR, 1 DATA, 1 SOUNDER, 1 POWER d approved as noted. see comments on garage. 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN / Ci) meet with fire marshal to explore notification of ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE EOLR p El ® e both units when flow switch activated. DEPARTMENT REQUIREMENTS AND NFPA 72. U_ (9) (9) (12) (1) 2. REFER TO MANUFACTURERS DATA SHEETS AND Honeywell z INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION VISTA 128 REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, ,C), PROGRAMMING AND DEVICE OPERATION. Ct KP 0 DIALER IJJ J o DEDICATED 120V J w CV C.0 TELE LINES CO °° co PRIMARY RESIDENCE D x o 2 SYSTEM ONE- LINE DIAGRAM om z NOTE 1. NO T-TAPPING PERMITTED ON ANY CIRCUIT . 0 OD NOTE 2. ALL WIRING TO BE 18AWG FPL. > 0 O J SEQUENCE OFz Q o Q w0 OPERATIONS: (n J Z QZ Z oz X ti,� CO ,ss O (n OO O < O O �' N W N D Z E _ = 2 0_ 2 O 2 O o Zi- < N � � E ct 1- m Li_ M N 0 U) 0 i_ U O Et i_(/) i- IL/) DEVICE aa D � � � A,- > z z z > >DESCRIPTIONo o o a � i- i- a � QOag. SMOKE DETECTOR X X X D1111. ■ ■ HEAT DETECTOR X X X CARBON MONOXIDE DETECTOR X X X NOTE: THIS DUPLEX CONSISTS OF 6 LEVELS. THE LOWER (1ST) LEVEL SERVES AS THE GARAGE SPRINKLER WATERFLOW SWITCH X X X X AND ENTRY FOR BOTH THE PRIMARY AND SECONDARY RESIDENCES. THE 2ND AND 3RD LEVELS 00 ARE DEDICATED TO THE PRIMARY RESIDENCE AND THE 4TH, 5TH & 6TH LEVELS ARE THE SPRINKLER TAMPER SWITCH X X M SECONDARY RESIDENCE. THE UNITS HAVE BEEN SUBMITTED AS TWO SEPARATE PERMITS WITH TWO SEPARATE FIRE ALARM SYSTEMS. 1i POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X 0) CD PRIMARY RESIDENCE ZONE LIST PRIMARY RESIDENCE PROJECTN FO R MATI 0 N : 6) w Ademco Vista 128 FACP _ 0_ DEVICE # DEVICE TYPE LEVEL DESCRIPTION Standby FISHER RESIDENCE - P R I IV A RY u) 001 MONITOR 2 SPRINKLER WATERFLOW Number of Current Total Current U (2/ 002 MONITOR 2 SPRINKLER TAMPER Device Type Devices (Amps) (Amps) VAIL COLORADO z w 003 SMOKE DETECTOR 1 ELEVATOR LANDING Main FACP CPU 1 X 0.032 = 0.032 z 004 CO DETECTOR 1 MAIN ENTRY 4193SN Serial Interface 12 X 0.00015 = 0.0018 F R E ALARIV SYSTEM O Q = 005 HEAT DETECTOR 1 GARAGE 5192SD Smoke Detectors 12 X 0.00084 0.01008 • 12L006 SMOKE DETECTOR 2 HALLWAY BY BEDROOMS Carbon Monoxide Detectors 9 X 0.00025 0.00225 = 007 CO DETECTOR 2 HALLWAY BY BEDROOMS 6160 Keypad 1 - X- 0.04 =- 0.04 AHJ: VAIL FIRE & EMERGENCY SERVICES U 008 SMOKE DETECTOR 2 NW BEDROOM SUM COLUMN FOR STANDBY LOAD 0.08613 = AMPS APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC w = 009 CO DETECTOR 2 NW BEDROOM OCCUPANCY: GROUP R W < 010 _SMOKE DETECTOR 2 N CENTER BEDROOM Alarm Load 011 SMOKE DETECTOR 2 NW BEDROOM Number of Current Total Current USE: DUPLEX 012 CO DETECTOR 2 FAMILY ROOM Device Type Devices (Amps) (Amps) FIRE ALARM SYSTEM FOR PRIMARY RESIDENCE OF DUPLEX. SYSTEM J m 013 SMOKE DETECTOR 2 FAMILY ROOM Main FACP CPU 1 X 0.032 = 0.032 014 SMOKE DETECTOR 2 EAST BEDROOM 41935N Serial Interface 12 X 0.00015 = 0.0018 INCLUDES NEW ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. = w 015 CO DETECTOR 2 EAST BEDROOM 5192SD Smoke Detectors 12 ' X 0.0196 = 0.2352 SMOKE DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS, STAIRWELL 0 I- Ili 016 SMOKE DETECTOR 3 GREAT ROOM Carbon Monoxide Detectors 9 X 0.00025 = 0.00225 LANDINGS AND AREAS OUTSIDE OF SLEEPING ROOMS. A HEAT DETECTOR 0 - - 017 CO DETECTOR 3 GREAT ROOM 6160 Keypad 1 X 0.1 = 0.1 WILL BE INSTALLED IN GARAGE. SOUNDERS WILL BE PROVIDED IN 121 Qct >- 018 SMOKE DETECTOR 3 MASTER BEDROOM MHVV Sounder 9 X 0.066 = 0.594 O 019 CO DETECTOR 3 MASTER BEDROOM Outside Horn/Strobe 1 X 0.195 = 0.195 SLEEPING ROOMS AND AS NEEDED TO ACHIEVE AUDIBILITY. A KNOX BOX o Q �/O I- 020 SMOKE DETECTOR 3 NW BEDROOM SUM COLUMN FOR ALARM LOAD 1.16025 = AMPS WILL BE MOUNTED ON THE OUTSIDE OF THE HOME. MONITORED CARBON J U 0 021 CO DETECTOR 3 NW BEDROOM Standby Load Required Standby Time in Hours MONOXIDE DETECTORS ARE PROVIDED. J O < w 022 CO DETECTOR 3 HALLWAY BY BEDROOMS Current (Amps) z 023 SMOKE DETECTOR 3 HALLWAY BY BEDROOMS 0.08613 X 24 = 2.07 j U I- 0 024 SMOKE DETECTOR 3 LOUNGE Alarm Load Required Alarm Time in Hours _Iz 025 Current (Amps) (15 MINUTES) Q Q O w 026 1.16025 X 0.25 0.29 > U Q 027 Add Standby and Alarm Load for Required FIRE PROTECTION ENGINEER: 028 Ampere Hour Battery SHEET DESCRIPTION: 029 Multiply by the Derating Factor of 1.2 DEBORAH SHAN ER, P.E., SHAN ER LIFE SAFETY 030 Total Ampere Hours Required 2.83 PO BOX 1073, FRISCO, CO 80443 FIRE ALARM PLAN THRU Batteries Provided: 4AH Minimum PHONE: 970-409-9082 050 FAX: 970-797- 1898 DRAWN BY: DATE: DLS 11/3/15 SHEET#: PRIMARY RESIDENCE FA-0.00P