A15-0106_RFS Cable Plenum_1450719060.pdf
Product Data Sheet ICA12-50JPL Wa 1/2" ClearFill®Line Plenum-Rated Air-Dielectric Coaxial Cable for In-Building Applications 1 Product Description ClearFill®Line 1/2"low loss air dielectric cable,Plenum-rated Application: Plenum In-Building 1=1111/1rtiVrt - - 1/2"Plenum-Rated In-Building Cable Features/Benefits •Supports Multiple RF Signals •Complete Shielding Frequency Attenuation Power The solid outer conductor of the ClearFill®Line coaxial cable creates a continuous RFI/EMI shield that [MHz] [dB/100m [dB/100ft] [kW] minimizes system interference. 0.5 0.148 0.0452 21.4 •Outstanding Intermodulation Performance 1.0 0.210 0.0641 21.4 RFS coaxial cable's solid inner and outer conductors virtually eliminate intermods. 1.5 0.258 0.0785 21.4 Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory. 2.0 0.298 0.0908 21.4 •Wide Range of Applications 10 0.671 0.204 21.4 Typical areas of application are:feedlines for plenum-space installations within 20 1.17 0.2918 .3516.5 30 1. occupied 9 ied buildin s or structures. 50 1.52 0.4658 13.4 1.52 0.465 10.3 88 2.04 0.622 7.71 100 2.18 0.665 7.21 108 2.27 0.692 6.93 Technical150 2.70 0.822 5.82 Features 174 2.92 0.889 5.39 Structure 200 3.14 0.957 5.01 Inner conductor: Copper-Clad Aluminum Wire [mm(in)] 4.8(0.19) 300 3.89 1.19 3.47 400 4.54 1.39 3.47 Dielectric: Extruded Polyethylene [mm(in)] 15.8(0.623) 450 4.84 1.48 3.25 Outer conductor: Annularly Corrugated Copper [mm(in)] 13.8(0.54) 500 5.13 1.56 3.07 Jacket: Plenum [mm(in)] 15.93(0.627) 512 5.19 1.58 3.03 Mechanical Properties 600 5.66 1.73 2.78 700 6.16 1.88 2.56 Weight,approximately [kg/m(lb/ft)] 0.40(0.27) 800 6.64 2.02 2.37 Minimum bending radius,single bending [mm(in)] 120(5) 824 6.75 2.06 2.33 Minimum bending radius,repeated bending [mm(in)] 254(10) 894 7.06 2.15 2.23 Bending moment [Nm(Ib-ft)] 4.1(3.0) 900 7.08 2.16 2.23 Max.tensile force [N(Ib)] 1112(250) 925 7.19 2.19 2.19 Recommended/maximum clamp spacing [m(8)] 0.5/0.9(1.8/3.0) 0960 7.34 2.24 2.15 1000 7.51 2.29 2.10 Electrical Properties 1250 8.52 2.60 1.85 Characteristic impedance [n] 50+/-2 1500 9.45 2.88 1.67 Relative propagation velocity [%] 91 1700 10.2 3.09 1.55 Capacitance [pF/m(pF/ft)] 76(23.2) 2000 13.20 1.4 2000 111.2.2 3.40 1.41 Inductance [pH/m(pH/ft)] 0.190(0.058) 2200 11.8 3.59 1.34 m Max.operating frequency [GHz] 6 2300 12.1 3.69 1.31 ✓ Jacket spark test RMS [V] 8000 2600 13.0 3.96 1.22 o Peak power rating [kW] 21.4 3000 14.1 4.31 1.12 ° RF Peak voltage rating M 1500 3500 15.5 4.73 1.02 [0/km(fl/1000ft)] 1.48(0.45) 3600 15.8 4.81 1.00 E DC-resistance inner conductor4000 16.8 5.13 0.945 m DC-resistance outer conductor [0/km(0/1000ft)] 1.90(0.58) 4500 18.1 5.51 0.878 o Recommended Temperature Range 5000 19.3 5.88 0.825 Storage temperature [°C(°F)] -15 to+85(5 to+185) 5500 20.4 6.23 0.781 4t6000 21.6 6.58 0.739 � Installation temperature [°C(°F)] -15 to+60(5 to+140) o Operation temperature [°C(°F)] -15 to+85(5 to+185) Attenuation at 20°C(68°F)cable temperature 11 Other Characteristics Mean power rating at 40°C(104°F)ambient temperature g Fire Performance: Flame Retardant,Plenum Rated VSWR Performance: Standard [dB(VSWR)] 18(1.228:1)in specified 5 bands y Other Options: m m v c N N N a N L_ C_ t d C C 0 0 C O .@ E , c RFS The Clear Choice® ICA12-50JPL Rev:BO/14.June.2010 Please visit us on the internet at htto://www.rfsworld.com/ Radio Frequency Systems