HomeMy WebLinkAboutA15-0087_XP-95 Bases SNDR_1444243620.pdf �Gamewell Series 95 Bases Fe' FIRE TRUMENTS CONTROL INS by Honeywell Description Analog Addressable Sensors The Gamewell-FCI XP-95 Series bases provide superior flexibility for the installation of the Gamewell-FCI, XP95 family of addressable detectors. Whether the project requires a 4.0" (10.16 cm), relay or sounder base, the XP95 *y family has a base to meet building aesthetics, constraints, • retrofit limitations or functional needs. The device address :„10011111:::1 ; is held in the base, ensuring that the device address will + J. not be changed no matter how often a detector is replaced, _ and verifying a consistent match between device type and r device address. Each XP95 analog addressable head is compatible with a wide variety of XP-95 bases, ranging from one-piece low- Series 95 profile units to four-wire relay and sounder bases that can be controlled individually or as a group.The XP95 Series of Features detector bases has been designed to enable sensors to be plugged-in with minimum force and to have a "one-way- only" fit. Relay and sounder bases can be addressed and • Compatible with all of the Gamewell-FCI 600 Series controlled individually or by a group in response to the analog addressable detectors sensor alarms. • Base options include: — 4.0"(10.16 cm)or 6.0"(15.24 cm) ultra-low-profile Programming bases feature'one-way"fit with low insertion force — 6.0"(15.24 cm)relay base(4 wire) The only programming required at the Series 95 sensors is — Audible alarm sounder bases controlled individually address setting, via the patented XPert addressing card. or by group • The card is inserted into the sensor base.When the sensor Device address is stored in the sensor base • head is inserted into the base,the address is automatically Address is set by patented XPert addressing card • relayed to the sensor. Changing the sensor does not Compatible with all Gamewell-FCI XP95 protocol detection devices require additional programming since the address remains on the XPert Card located in the base. All other sensor- specific programming is accomplished at the Fire Alarm Control Panel (FACP). The XPert addressing card ensures that only the correct device types can be installed in given locations after cleaning or other maintenance operations. Installation The complete range of Series 95 addressable mounting An ISO 9000-2000 Company bases will accept any of the Series 95 sensors. The bases SIGNALING have a wide interior diameter for ease of access to wires 0 and terminals.The design of the base is such that the LISTED S1195 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2048 Rev.al page 1 of 2 Installation (Continued) Specifications (Continued) sensor will fit in only one way, and a simple clockwise motion(without force)is required to plug-in the sensor.The Relay Base mounting base will have provisions for the insertion of the Model: XP95-B6R4 XPert addressing card as a means for programming and Alarm Current: 0.0036 A maintaining the sensor's address. Standby Current: 2 pA. Relay Rating: 0.04 A @ 125 VAC resistive The XP95-B4 base 4.0" (10.16 cm) will mount directly to a loading. 3.5" (8.89 cm) octagonal box (Raco 110 or equal) or a 4" Sounder Level: N/A (10.16 cm) octagonal box (Raco 125 or equal) with a round Captive Terminals: Yes cover/plaster ring (Raco 727 or equal).The other Series 95 bases 6.0" (15.24 cm) will mount directly to a 3.5" (8.89 cm) Sounder Base octagonal box (Raco 110 or equal); to a 4.0" (10.16 cm) Model:XP95-B65NDR octagonal box (Raco 125 or equal); or to a 4.0" (10.16 cm) Alarm Current: 0.030 A square backbox(Raco 190 or equal). Standby Current: 2 pA. Relay Rating: N/A Engineer's Specifications Sounder Level: 85 dB @ 10 ft.(3.048 m) Captive Terminals: Yes The contractor shall furnish and install, as indicated on the plans, either dual-chamber ionization (Gamewell-FCI Ordering Information model XP95-I) or photoelectric (Gamewell-FCI model XP95-P) smoke sensors, analog addressable multisensor Model Description (XP95-M) or electronic thermal sensor (Gamewell-FCI XP95-B4 4.0"(10.16 cm) mounting base with model XP95-T)with one of the several addressable mount- XPert addressing card XP95-B6R4 6.0"(15.24 cm) relay base(four- ing base available options. The combination sensor head wire)with XPert addressing card and twist-lock mounting base shall be UL Listed and UL XP95-B6EZ 6.0"(15.24 cm) ultra-low-profile EZ- Listed as compatible with the Gamewell-FCI 600 Series fit mounting base with XPert analog addressable fire alarm control panels. The base addressing card shall permit free interchange of sensor heads without XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible requiring any additional wiring or additional programming alarm sounder in the base of the head or base. (MB-SDR-XP95) 30203 Remote LED (24 VDC) 71112 Additional Bbank XPert Specifications addressing cards 4" Base Model: XP95-B4 Alarm Current: N/A Standby Current: N/A Relay Rating: N/A Sounder Level: N/A Captive Terminals: Yes 6" Base Model:XP95-B6EZ Alarm Current: N/A Standby Current: N/A Relay Rating: N/A Sounder Level: N/A Captive Terminals: Yes GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2048 Rev.al page 2 of 2 www.gamewell-fci.com