Loading...
HomeMy WebLinkAboutA15-0087_XP95-P_1444243620.pdf Gamewell XP95-P Fe' FIRE TRUMENTS CONTROL INS by Honeywell Description Photoelectric Smoke Sensor The Gamewell-FCI XP95-P analog addressable photoelec- tric sensor operates with the Gamewell-FCI analog addres • - sable Fire Alarm Control Panels (FACPs). The • photoelectric sensor digitally transmits its address and the Y 1 chamber's analog values to the FACP for analysis. The • photoelectric sensor is distinguished by the clear status LED, which flashes red briefly when the device is polled and turns on continuously when the device is in alarm. � I / Operation 01.4— / The XP95-P photoelectric sensor constantly monitors its _ sensing chamber and its internal electronics. The results 0 are then reported along with the unit's address through the XP95-P integral communications electronics located in the sensor head. The XP95 photoelectric sensor utilizes a patented smoke chamber and infrared smoke sensing design. The Features infrared emitter generates a burst of light every second, or in response to direct interrogation. • Compatible with the Gamewell-FCI 600 Series analog In clean air, the photo diode receives no light from the addressable control panels emitter because of the arrangement of the chamber.When • Fits 4.0"(10.16 cm)or 6.0"(15.24 cm) ultra-low-profile smoke enters the chamber, it scatters light from the emitter E-Z fit bases onto the photo diode receptor in proportion to smoke char- • Audible alarm sounder base acteristics and density. As the smoke content in the cham- • Four-wire relay base ber increases, the signal from the photo diode receptor • Address is stored in the sensor base increases. This information is processed and conditioned • Address is set by XPert addressing card by an on-board, advanced-technology ASIC and digitally • Two-color status LED transmitted to the FACP. • Infrared smoke sensing design • Continuous communications Trouble and Alarm conditions of the XP95 sensors are • Optional remote LED actually determined at the control panel. The status infor- mation of each sensor is analyzed for off-normal conditions by the FACP. If the sensor reports a condition that matches its programmed trouble signature,the FACP will detect that the sensor is in trouble and will follow its programmed response sequence. If the status reported matches the alarm signature, the FACP will follow the programmed An ISO 9000-2000 Company alarm response for the specific device in alarm. When a SIGNALING sensor is in alarm,the integral LED in the sensor's housing will light continuously. L ® MEA LISTED Approved 51195 APPROVED 149-99-E GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fcLCom CS-2054 Rev.al page 1 of 2 Operation (Continued) Ordering Information The XP95-P photoelectric device is connected to a two- Model Description wire SLC carrying both data and a 17 to 28 VDC supply XP95-P Photoelectric sensor, analog voltage, and is insensitive to loop connection polarity. A addressable (55000-650) remote LED indicator may be connected. The device is XP95-B4 4.0"(10.16 cm)mounting base with compatible with point-or group-addressable relay and XPert addressing card (45681-2101) sounder bases. XP95-B6R4 6.0"(15.24 cm)relay base (four-wire)with XPert addressing card Engineer's Specifications XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible alarm The contractor shall furnish and install, where indicated on sounder in the base the plans, photoelectric smoke sensors with one of the 71112 Additional blank XPert addressing cards several addressable mounting base options available. The 30203 Remote LED (24 V)on single gang combination sensor head and twist-lock mounting base plate shall be UL Listed and UL Listed as compatible with the Gamewell-FCI 600 Series analog addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The photo- electric smoke sensor shall be the Gamewell-FCI model XP95-P. Specifications Standby Current: 340 pA Alarm LED Current: 0.00434 A Remote Alarm Output: 0.004 A @ 5 VDC Temperature Range: 32°F to 140°F(0° C to 60° C) Relative Humidity: (non-condensing)0%to 95% Recommended Spacing: Meets the 30 ft. (9.1 m)spacing guidelines in NFPA 72 Chapter 2. However,this spacing is based on ideal conditions and is to be used as a layout guide only.Appropriate installation-specific engineering is required. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2054 Rev.al page 2 of 2 www.gamewell-fci.com