Loading...
HomeMy WebLinkAboutA16-0002_cut sheets_1451947320.pdf E SimpIEX TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors— Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories � Features TrueAlarm analog sensing provides: • Digital transmission of analog sensor values via IDNet ` .• or MAPNET II two-wire communications • For use with the following Simplex®products: • 4007ES,4010,4010ES,4100ES,and 4100U Series control panels;and 4008 Series control panels with -----� A f/ reduced feature set(refer to data sheet S4008-0001 for \ — f details) ' • 4020,4100,and 4120 Series control panels,Universal 4098-9714 TrueAlarm Photoelectric Transponders,and 2120 TrueAlarm CDTs equipped Sensor Mounted in Base for MAPNET II operation Fire alarm control panel provides: Descri•tion • Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Digital Communication of Analog Sensing. • Sensitivity monitoring satisfying NFPA 72 sensitivity TrueAlarm analog sensors provide an analog testing requirements; automatic individual sensor measurement digitally communicated to the host control calibration check verifies sensor integrity panel using Simplex addressable communications.At the • Automatic environmental compensation,multi-stage control panel,the datais analyzed and an average value is alarm operation,and display of sensitivity directly in determined and stored.An alarm or other abnormal percent per foot condition is determined by comparing the sensor's present • Ability to display and print detailed sensor value against its average value and time. 1 information in plain English language Intelligent Data Evaluation.Monitoring each sensor's Photoelectric smoke sensors provide: average value provides a continuously shifting reference • Seven levels of sensitivity from 0.2%to 3.7% point.This software filtering process compensates for I (refer to additional information on page 3) environmental factors(dust,dirt,etc.)and component I Heat sensors provide: aging,providing an accurate reference for evaluating new • Fixed temperature sensing activity.With this filtering,there is a significant reduction • • • Rate-of-rise temperature sensing in the probability of false or nuisance alarms caused by • Utility temperature sensing shifts in sensitivity,either up or down. • Listed to UL 521 and ULC-S530 Control Panel Selection.Peak activity per sensor is General features: stored to assist in evaluating specific locations.The alarm • Operation is for ceiling or wall mounting set point for each TrueAlarm sensor is determined at the •• • Listed to UL 268 and ULC-S529 host control panel,selectable as more or less sensitive as the individual application requires. • Louvered smoke sensor design enhances smoke capture by directing flow to chamber;entrance areas Timed/Multi-Stage Selection.Sensor alarm set points • are minimally visible when ceiling mounted can be programmed for timed automatic sensitivity • Designed for EMI compatibility selection(such as more sensitive at night,less sensitive • Magnetic test feature is provided during day).Control panel programming can also provide • Different bases are available to support a supervised multi-stage operation per sensor.For example,a 0.2% or unsupervised output relay,and/or a remote LED level may cause a warning to prompt investigation while a alarm indicator 2.5%level may initiate an alarm. Additional base reference: Sensor Alarm and Trouble LED Indication.Each • For isolator bases,refer to data sheet S4098-0025 sensor base's LED pulses to indicate communications • For sounder bases,refer to data sheet S4098-0028 with the panel.If the control panel determines a sensor is • For photo/heat sensors,refer to data sheet S4098-0024 in alarm,or is dirty or has some other type of trouble,the (single address)and S4098-0033(dual address) details are annunciated at the control panel and that sensor • These products have been approved by the California State Fire Marshal(CSFM)pursuant to base's LED will be turned on steadily.During a system Section 13144.1 of the California Health and Safety Code.See CSFM Listings alarm,the control panel will control the LEDs such that • 7272-0026:218,7271-0026:231,7270-0026:216,and 7300-0026:217 for allowable values an LED indicating a trouble will return to pulsing to help and/or conditions concerning material presented in this document Accepted for use—City of identify the alarmed sensors. New York Department of Buildings—MEA3S-93E.Additional listings may be applicable, contact your local Simplex product supplier for The latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S4098-0019-20 112015 TrueAlarm Sensor Bases and Accessories Description Sensor Base Features - TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the Base mounted address selection: detachable photoelectric or heat sensors.Each sensor's • Address remains with its programmed location output is digitized and transmitted to the system fire alarm • Accessible from front(DIP switch under sensor) control panel every four seconds. General features: • Automatic identification provides default sensitivity when Since TrueAlarm sensors use the same base,different substituting sensor types sensor types can be easily interchanged to meet specific • Integral red LED for power-on(pulsing),or alarm or trouble location requirements.This feature also allows intentional (steady on) sensor substitution during building construction.When • Locking anti-tamper design mounts on standard outlet box conditions are temporarily dusty,instead of covering the Magnetically operated functional test smoke sensors(causing them to be disabled),heat sensors • may be installed without reprogramming the control Sensor Bases panel.Although the control panel will indicate an incorrect sensor type,the heat sensor will operate at a 4098-9792,Standard Sensor Base default sensitivity providing heat detection for building 4098-9789,Sensor Base with wired connections for: protection at that location. • 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Mountin• Reference Supervised Relay Bases(not compatible with 2120 CDT): • 4098-9791,4-Wire Sensor Base,use with remote or Electrical Box Requirements:(boxes are by others) locally mounted 2098-9737 relay,requires separate 24 VDC Without relay in the box:4"octagonal or 4"square,1-1/2"deep; ' • 4098-9780,2-Wire Sensor Base,use with remote or single gang,2"deep locally mounted 4098-9860 relay,no separate power With relay in the box:4"octagonal or 4"square,1-1/2"deep, required _ with 1-1/2"extension ring • Supervised relay operation is programmable and can be 4"(102 mm)Square Box 4"(102 mm)Octagonal Box manually operated from control panel Surface mount referenc- • Includes wired connections for remote LED alarm indicator —_i i or 4098-9822 relay(relay is unsupervised and requires separate 24 VDC) ME C ED Sensor Base 0•tions }r 1-1/2"(38 mm) + 2098-9737, Remote or local mount supervised relay: minimum box depth Flush mount reference,mount even with final • DPDT contacts for resistive/suppressed loads,power limited surface,or with up to 1/4"(6.4 mm)maximum recess rating of 3 A @ 28 VDC;non-power limited rating of 3 A 2098-9737 Supervised Relay 4098.9822 Relay(mounts @ 120 VAC(requires external 24 VDC coil power) (mounts in base electrical box or in base electrical box) 4098-9860,Remote or local mount supervised relay: remotely) `� - • SPDT dry contacts,power limited rating of 2 A @ 30 VDC, �` -' resistive;non-power limited rating of 0.5 A @125 VAC, (s resistive Relay Size: 2-1/2"X 1-1/2"X 1" 4098-9822,LED Annunciation Relay: (3.75 in3)(64 mm X 38 mm X 25.4 mm) l' • Activates when base LED is on steady,indicating local if.- alarm alarm or trouble 4098-9860 Supervised Relay(mounts in base electrical box or remotely;2-3/8"X 1-1/4"X 11/32" • DPDT contacts for resistive/suppressed loads,power limited (1 in3)(60.4 mm X 31.8 mm X 8.6 mm) Alliill.41.71 rating of 2 A @ 28 VDC;non-power limited rating of mi®lml 1/2 A @ 120 VAC,(requires external 24 VDC coil power) NOTE:Review total wire count,wire size,and accessories being 4098-9832,Adapter plate: wired to determine required box volume. I • Required for surface or semi-flush mounting to 4"square electrical box and for surface mounting to 4"octagonal box I I. 6-3/8"(162 mm) l • Can be used for cosmetic retrofitting to existing 6-3/8" t 4098-9832 Adapter Plate,required for diameter base product N. . 1/4" mounting to su ace mounted boxes 2098-9808, Remote red LED Alarm (6.4 mm) and 4"s uare flush box • B Indicator: 14-7/8"(124 mm)___,,..I • Mounts on single gang box(shown in illustration to right) ALARM0 (24 mm)I- o ) TrueAlarm Bases Simplex 4098-9780,4098-9789,4098-9791,&4098-9792 S/ 2 - S4098-0019-20 1/2015 I TrueAlarm Sensors 1 Features 4098-9733 Heat Sensor Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate Interchangeable mounting compensated,fixed temperature sensing,selectable with EMI/RFI shielded electronics or without rate-of-rise temperature sensing.Due to its I. Heat sensors: small thermal mass,the sensor accurately and quickly • Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire sensing with or without rate-of-rise operation alarm control panel. • Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the control panel for either 15°F(8.3°C)or 20°F(11.1°C) Fixed Temp. UL&ULC FM Spacing,Either Fixed per minute,Fixed temperature sensing is independent of ' 1 Setting Spacing Temperature Setting rate-of-rise sensing and programmable to operate at 135°F 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fixed 135°F(57.2°C)or 155°F(68°C).In a slow developing (57.2°C) (18.3 m) temperature only;RTI=Quick 50 ft x 50 ft(15.2 m)for fixed fire,the temperature may not increase rapidly enough to 155°F 40 ft x 40 ft temperature with either rate-of-rise operate the rate-of-rise feature.However,an alarm will be (68°C) (12.2 m) selection;RTI=Ultra Fast initiated when the temperature reaches its rated fixed Smoke Sensors: temperature setting. • Photoelectric technology sensing TrueAlarm heat sensors can be programmed as a utility • 360°smoke entry for optimum response device to monitor for temperature extremes in the range from 32°F to 155°F(0°C to 68°C).This feature can • Built-in insect screens provide freeze warnings or alert to HVAC system problems.Refer to specific panels for availability. 4098-9714 Photoelectric Sensor 4-7/8"(124 mm) TrueAlarm photoelectric sensors use a stable,pulsedI infrared LED light source and a silicon photodiode II�LI=n status indicator i receiver to provide consistent and accurate low power 2-318" IME smoke sensing.Seven levels of sensitivity are available (60 mm) 1 for each individual sensor,ranging from 0.2%to 3.7%per ��I;�III■I r `_I foot of smoke obscuration.Sensitivities of 0.2%,0.5%, �.F and 1%are for special applications in clean areas. _ Standard sensitivities are 1.5%,2.0%,2.5%,3.0%,and - 3.7%.Application type and sensitivity are selected and 4098-9733 Heat Sensor with Base then monitored at the fire alarm control panel.* The sensor head design provides 360°smoke entry for WARNING: In most fires, hazardous levels of smoke optimum response to smoke from any direction.Due to its and toxic gas can build up before a heat detection photoelectric operation,air velocity is not normally a device would initiate an alarm.In cases where Life factor,except for impact on area smoke flow. Safety is a factor,the use of smoke detection is highly recommended. I 4-7/8"(124 mm) °"—LED status indicator Application Reference 2-1/8" (54 mm) Sensor locations should be determined only after careful 1=1l1•�I=IlM.11iMM consideration of the physical layout and contents of the I ��■����� -1/ area to be protected.Refer to NFPA 72,the National Fire Alarm and Signaling Code.On smooth ceilings, smoke 4098-9714 Photoelectric Sensor with Base sensor spacing of 30 ft(9.1 m)may be used as a guide.* "For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-20 1/2015 ' I • TrueAlarm Analo• Sensin• Product Selection Chart TrueAlarm Sensor Bases(for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description Compatibility Mounting Requirements 4098-9792 Standard Sensor Base No options 4"octagonal or 4"square box, 1-1/2"min. depth;or single gang box,2"min.depth Sensor Base with connections for 2098-9808 Remote Alarm Indicator or 4098-9789 Remote LED Alarm Indicator or 4098-9822 Unsupervised Relay 4"octagonal or 4"square box Unsupervised Relay 4-Wire Sensor Supervised Relay 2098-9737 Supervised Remote Relay Note:Box depth requirements depend on total wire count and wire size,refer to 4098-9791** Base with connections for LED 2098-9808 Remote Alarm Indicator or Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay accessories list below for reference. 2-Wire Sensor Supervised Relay 4098-9860 Supervised Remote Relay ""NOTE:4098-9791 and 4098-9780 are NOT 4098-97804' Base with connections for LED 2098-9808 Remote Alarm Indicator or compatible with the 2120 CDT `; Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay _3 TrueAlarm Sensors Model Description Compatibility Mounting Requirements � i„ I 4098-9714 Photoelectric Smoke Sensor Bases 4098-9792,4098-9789, •i —p4098-9733 Heat Sensor 4098-9791,and 4098-9780 Refer to base requirements TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements • • 2098 9737 Supervised Relay,mounts remote or in base For use with 4098 9791 base Remote Mounting requires 4"octagonal electrical box or 4"square box,1-1/2"minimum depth 4098-9860 Supervised Relay,mounts remote or in base For use with 4098-9780 base Base Mounting requires 4"octagonal electrical box box,2-1/8"deep with 1-1/2"extension ring • 2098-9808 Remote Red LED Alarm Indicator on single Bases 4098-9789,4098-9791, Single gang box, 1-1/2"minimum depth gang stainless steel plate and 4098-9780 • 4098-9822 Unsupervised Relay,tracks base LED status; Bases 4098-9789,4098-9791, 4"octagonal box,2-1/8"deep with 1-1/2" Note:Mounts only in base electrical box and 4098-9780 extension ring Bases 4098 9792,4098 9789, Required for surface or semi-flush 4098-9832 Adapter Plate 4098 9791,and 4098 9780 mounted 4"square box and for surface mounted 4"octagonal box S•ecifications General Operating Specifications Communications and Sensor Supervisory PowerIDNet or MAPNET II communications,auto-selected,1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical,no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads,18 AWG(0.82 mm2) UL Listed Operating Temperature Range 32°to 100°F(0°to 38°C) Operating Temperature with 4098-9733 Heat Sensor 32°to 122° F(0 to 50°C) `t Range with 4098-9714 Smoke Sensor 15°to 122°F(-9°to 50°C) i.j Storage Temperature Range 0° F to 140°F(-18°C to 60°C) 1 Humidity Range 10 to 95%RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min(0-1220 m/min) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737(see page 2 for contact ratings) • Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) • Supervisory Current 270µA,from 24 VDC supply __ Alarm Current with 2098-9737 Relay 28 mA,from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860(see page 2 for contact ratings) Power Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789.4098-9791,and 4098-9730(see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) . Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TYCO,SLVPLEX,and rhe product names listed in this material are marks and'or registered narks.Unauthorized use is stricrly prolnhued.NFPA 72 and National Fire Alarm and Signaling Code are trademarks'of the National Fire protection Association(NFPA). aS i m pl ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4098-0019-20 1/2015 -. www.simplex-fire.com 02015 Tpcn Fire Protection Products.All rights reserved.All specifications and other•infomaation shown were current as of document revision date and are subject to change without notice. :i