Loading...
HomeMy WebLinkAboutA16-0006_Coax Cable&Passive Components_1453306800.pdf ProductSpecifications ANDREW. Cort m5Cope Company CE LLMAX-D-C PUS Cell-MaxTM Directional In-building Antenna, 824-960 MHz and 1710-2500 MHz ■ CHARACTERISTICS Dimensions Height 203.00 mm I 7.99 in Length 46.00 mm I 1.81 in Net Weight 0.50 kg I 1.10 lb Width 156.00 mm I 6.14 in Electrical Specifications Beamwidth, Horizontal 85° nominal Beamwidth, Vertical 75° nominal Gain at Frequency Band 7.0 dBi @ 824-960 MHz Impedance 50 ohm Input Power, maximum 50 W Operating Frequency Band 824 - 960 MHz Polarization Vertical Return Loss 11.0 dB VSWR 1.7:1 Electrical Specifications (Band 2) Beamwidth, Horizontal 85° nominal Beamwidth, Vertical 75° nominal Gain at Frequency Band 7.0 dBi @ 1710-2500 MHz Operating Frequency Band 1710 - 2500 MHz Return Loss at Frequency Band 11.0 dB @ 1710-2500 MHz From North America,toll free Outside North America ©2008 CommScope,Inc.All rights reserved. Telephone: 1-800-255-1479 Telephone:+1-708-873-2307 All specifications are subject to change.Please see page 1 of 2 Fax: 1-800-349-5444 Fax:+1-779-435-8579 www.andrew.com for the most current information. 12/2/2008 ProductSpecifications ANDREW. CortFrrtScope Company CELLMAX-D-CPUS VSWR 1.7:1 Environmental Specifications Application Indoor Operating Temperature -30 °C to +70 °C (-22 °F to +158 °F) Relative Humidity Up to 100% General Specifications Antenna Type Directional Operating Frequency Band 1710 - 2500 MHz I 824 - 960 MHz Brand Cell-MaxTM Color White Interface N Female Package Quantity 1 Pigtail Cable RG58, plenum rated Radome Color White Radome Material Description ABS, UV resistant Mechanical Specifications Mounting 4-hole wall mounting plate and hardware included Pigtail Length 350.0 mm I 13.8 in Packed Dimensions Height 60.0 mm I 2.4 in Length 270.0 mm I 10.6 in Shipping Weight 0.73 kg I 1.61 lb Volume 0.0037 m3 Width 230.0 mm I 9.1 in From North America,toll free Outside North America ©2008 CommScope,Inc.All rights reserved. Telephone: 1-800-255-1479 Telephone:+1-708-873-2307 All specifications are subject to change.Please see page 2 of 2 Fax: 1-800-349-5444 Fax:+1-779-435-8579 www.andrew.com for the most current information. 12/2/2008 40°' Product Specifications ANDREW. A CommScope Company C E L LMAX-O-C F U S E Cell-Max-"' Omnidirectional In-building Antenna, 698-960 MHz and 1710-2700 MHz • This product is part of the CommScope Wired for Wireless-r"' Solution CHARACTERISTICS General Specifications Antenna Type Omnidirectional Operating Frequency Band 1710 - 2700 MHz I 698 - 960 MHz Brand Cell-MaxTM Color White Interface N Female Package Quantity 1 Pigtail Cable KSR195, plenum rated Radome Color White Radome Material ABS, UV resistant Electrical Specifications Operating Frequency Band 698 - 800 MHz Beamwidth, Horizontal 360° omnidirectional Beamwidth, Vertical 80° nominal Gain at Frequency Band 1.5 dBi @ 698-800 MHz Impedance 50 ohm Input Power, maximum 50 W Polarization Vertical Return Loss 10.9 dB VSWR 1.8:1 Electrical Specifications (Band 2) Operating Frequency Band 1710 - 2700 MHz I 800 - 960 MHz Beamwidth, Horizontal 360° omnidirectional Beamwidth, Vertical 65° nominal Gain at Frequency Band 1.5 dBi @ 800-960 MHz I 5.0 dBi @ 1710-2700 MHz Return Loss at Frequency Band 13.9 dB www.COmrnscope.corn/a nd rew ©201 1 CommScope,Inc.All rights reserved. All trademarks identified by®or TM are registered trademarks or trademarks,respectively,of CommScope.All specifications are subject to change. page 1 of 2 See www.commscope.com/andrew for the most current information. 3/15/2011 40°' Product Specifications ANDREW. A CommScope Company CELLMAX-O-CPUSE VSWR 1.5:1 Mechanical Specifications Mounting Thru-hole ceiling mount (optional) Pigtail Length 315.0 mm I 12.4 in Environmental Specifications Application Indoor Operating Temperature -40 °C to +60 °C (-40 °F to +140 °F) Relative Humidity Up to 100% Dimensions Diameter, maximum 186.00 mm I 7.32 in Height 85.00 mm I 3.35 in Length 186.00 mm I 7.32 in Net Weight 0.30 kg I 0.66 lb Width 186.00 mm I 7.32 in Packed Dimensions Height 135.0 mm I 5.3 in Length 195.0 mm I 7.7 in Shipping Weight 0.41 kg I 0.90 lb Volume 5133.3000 cc Width 195.0 mm I 7.7 in Regulatory Compliance/Certifications Agency Classification RoHS 2002/95/EC Compliant by Exemption ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system ,•... ReF�S WWW.co mrnscope.com/andrew ©2011 CommScope,Inc.All rights reserved. All trademarks identified by®or TM are registered trademarks or trademarks,respectively,of CommScope.All specifications are subject to change. page 2 of 2 See www.commscope.com/andrew for the most current information. 3/15/201 1 Product Data Sheet I-ATB1-790/2700 Indoor/Outdoor Bidirectional Antenna 790-2700 MHz Product Description This bidirectional antenna is specifically designed for broadband in-/out-door distribution of 2G/3G/ 4G(LTE)/WLAN/WIMAX services.The antenna is constructed from lightweight materials suitable for wall and mast mounting. Bidirectional Antenna Features/Benefits •Bidirectional Antenna •Broadband,coverage 790 to 2700MHz •Sealed with radome,Strong protection ability •Low VSWR,High gain,Stable performance •Supplied with bracket kit Technical Specifications Product Type Bidirectional Antenna Application Indoor/Outdoor Frequency Range, MHz 790-960/1710-2700 Number of Input Ports 1 Connectors N female Impedance,Ohm 50 VSWR(50 Ohm) <_1.7 @790-960 and 1710-2700MHz Total Input Power,W max.50 Gain,dBi 6.0 @ 790-960 MHz 7.0 @ 1700-2700 MHz Polarization Vertical Horizontal Beamwidth,deg 85/60 Vertical Beamwidth,deg 60/50 Connector Cable, mm(in) 185(7.28) Radome Material ABS Radome Color White(RAL9010) o Mounting Hardware included Downtilt bracket kit Temperature Range, °C(°F) -40 to+60(-40 to 140) Height,mm(in) 210(8.27) o Width, mm(in) 65(2.55) Length,mm(in) 588(23.04) 0 Weight,kg(Ib) 1.35(2.98) o Environmental Class IP33 Notes y •When installing the antenna the little drainage hole in the random has to face downwards in order to prevent water ingress. � •Windspeed: 60m/s y Other Documentation N N a 0 U O RFS The Clear Choice® I-ATB1-790/2700 Rev:A/2013/02/06 Print Date:11.06.2014 Please visit us on the internet at http://www.rfsworld.com/ Radio Frequency Systems Product Data Sheet I-ATB1-790/2700 Indoor/Outdoor Bidirectional Antenna 790-2700 MHz Beam pattern 4 . /./.<--........,._ .------' \ . . -_ \ ‘r 1 i ,) v• \ . , . - - / ‘.,,,s'N.i... ' ''.. A 1 / \...,...:__ . ,.. . '''' ..„' r 1700 METz E plane 1700 MHz H plane . • . 790 MHz E plane 790 MHz H plane - - --* •-• • • • •(-.. -.-.-._ .7. I), , .r.,. .,.,.., \, .-- .. . .' r ) 190MlzEplane 1990MHzHplane plane 960MHzH plane , Installation Sketch Antenna ii-777 2500 MHz E plane 2300 MHz H plane Bracket _. c-- .1 _ . • Zi5 P r i ,_ .•. = Connector 0 \ / Z 6 r• E • ,,,) . _ ,_ 1 // \ , 7E_ custcrnel 11 L,____.--„-- , i . ..° . .. Mast by_. ,. § .2 2700 MHz E plane 2700 MHz H plane 115., c7, 2 ll 2 r, -E. ii 0. a, c S 2 42 8 2 'a E. ° S RFS The Clear Choice® I-ATB1-790/2700 Rev:A/2013/02/06 Print Date:11.06.2014 Please visit us on the internet at htto://www.rfsworld.com/ Radio Frequency Systems Product Specifications COMMSa3PE Systimax Solutions AL4RPV-50 AL4RPV-50, HELIAX® Plenum Rated Air Dielectric Coaxial Cable, corrugated aluminum, 1/2 in, off white PVC jacket • This product is part of the CommScope Wired for Wireless® Solution Construction Materials Jacket Material PVC Dielectric Material PE spline Flexibility Standard Inner Conductor Material Copper-clad aluminum wire Jacket Color Off-white Outer Conductor Material Corrugated aluminum Dimensions Nominal Size 1/2 in Cable Weight 0.21 kg/m I 0.14 lb/ft Diameter Over Jacket 15.926 mm I 0.627 in Inner Conductor OD 4.5720 mm I 0.1800 in Outer Conductor OD 14.046 mm I 0.553 in Electrical Specifications Cable Impedance 50 ohm +2 ohm Capacitance 76.0 pF/m I 23.0 pF/ft dc Resistance, Inner Conductor 1.570 ohms/km I 0.480 ohms/kft dc Resistance, Outer Conductor 1.570 ohms/km I 0.480 ohms/kft dc Test Voltage 4000 V Inductance 0.190 pH/m I 0.058 pH/ft Insulation Resistance 100000 Mohms•km Jacket Spark Test Voltage (rms) 5000 V Operating Frequency Band 1 - 6000 MHz Peak Power 40.0 kW Power Attenuation 2.325 Pulse Reflection 0.5% Velocity 86.5% Environmental Specifications Installation Temperature -20 °C to +60 °C (-4 °F to +140 °F) Operating Temperature -20 °C to +85 °C (-4 °F to +185 °F) Storage Temperature -20 °C to +85 °C (-4 °F to +185 °F) General Specifications Brand HELIAX® ©201 2 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively, of CommScope. page 1 of 4 All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised:April 23, 201 2 June 12,2012 Product Specifications COMMSa3PE AL4RPV-50 Mechanical Specifications Bending Moment 6.8 N-m I 5.0 ft lb Fire Retardancy Test Method NFPA 262/CATVP/CMP Flat Plate Crush Strength 1.4 kg/mm I 80.0 lb/in Minimum Bend Radius, Multiple Bends 127.00 mm I 5.00 in Minimum Bend Radius, Single Bend 64.00 mm I 2.50 in Number of Bends, minimum 15 Tensile Strength 159 kg I 350 lb Note Performance Note Values typical, unless otherwise stated Standard Conditions Attenuation, Ambient Temperature 20 °C I 68 °F Average Power, Ambient Temperature 40 °C I 104 °F Average Power, Inner Conductor Temperature 100 °C I 212 °F Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 806-960 MHz 1.25 19.00 1700-2200 MHz 1.25 19.00 ©201 2 CommScope, Inc.At rights reserved.All trademarks identified by®or TM are registered trademarks, respectively, of CommScope. page 2 of 4 All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised:April 23, 201 2 June 12,2012 Product Specifications COMMSa3PE AL4RPV-50 Attenuation Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW) 0.5 0.152 0.046 40.00 1 0.216 0.066 35.37 1.5 0.264 0.081 28.84 2 0.306 0.093 24.95 10 0.691 0.211 11.04 20 0.985 0.3 7.75 30 1.213 0.37 6.29 50 1.581 0.482 4.83 88 2.126 0.648 3.59 100 2.274 0.693 3.35 108 2.368 0.722 3.22 150 2.821 0.86 2.70 174 3.054 0.931 2.50 200 3.292 1.003 2.32 300 4.104 1.251 1.86 400 4.808 1.466 1.59 450 5.134 1.565 1.49 500 5.445 1.659 1.40 512 5.517 1.682 1.38 600 6.032 1.839 1.26 700 6.583 2.007 1.16 800 7.105 2.166 1.07 824 7.227 2.203 1.06 894 7.574 2.308 1.01 960 7.892 2.405 0.97 1000 8.081 2.463 0.94 1250 9.207 2.806 0.83 1500 10.256 3.126 0.74 1700 11.053 3.369 0.69 1800 11.439 3.487 0.67 2000 12.192 3.716 0.63 2100 12.559 3.828 0.61 2200 12.92 3.938 0.59 2300 13.276 4.046 0.57 2500 13.975 4.259 0.55 2700 14.656 4.467 0.52 3000 15.649 4.77 0.49 3400 16.928 5.159 0.45 3700 17.859 5.443 0.43 4000 18.768 5.72 0.41 5000 21.671 6.605 0.35 6000 24.42 7.443 0.31 * Values typical, guaranteed within 5% Regulatory Compliance/Certifications Agency Classification RoHS 2002/95/EC Compliant ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system ETL Certification CATVP/CMP ©201 2 CommScope, Inc.At rights reserved.All trademarks identified by®or TM are registered trademarks, respectively, of CommScope. page 3 of 4 All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised:April 23, 201 2 June 12,2012 Product Specifications coMMSC( PE- POWERED BY 01110NpREW. LDF4-50A LDF4-50A, HELIAX® Low Density Foam Coaxial Cable, corrugated copper, 1/2 in, black PE jacket Construction Materials Jacket Material PE Outer Conductor Material Corrugated copper Dielectric Material Foam PE Flexibility Standard Inner Conductor Material Copper-clad aluminum wire Jacket Color Black Dimensions Nominal Size 1/2 in Cable Weight 0.15 lb/ft I 0.22 kg/m Diameter Over Dielectric 12.954 mm I 0.510 in Diameter Over Jacket 15.875 mm I 0.625 in Inner Conductor OD 4.8260 mm I 0.1900 in Outer Conductor OD 13.970 mm I 0.550 in Electrical Specifications Cable Impedance 50 ohm +1 ohm Capacitance 23.1 pF/ft I 75.8 pF/m dc Resistance, Inner Conductor 0.450 ohms/kft I 1.480 ohms/km dc Resistance, Outer Conductor 0.820 ohms/kft I 2.690 ohms/km dc Test Voltage 4000 V Inductance 0.190 pH/m I 0.058 pH/ft Insulation Resistance 100000 Mohms•km Jacket Spark Test Voltage (rms) 8000 V Operating Frequency Band 1 - 8800 MHz Peak Power 40.0 kW Pulse Reflection 0.5% Velocity 88% Environmental Specifications Installation Temperature -40 °C to +60 °C (-40 °F to +140 °F) Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F) Storage Temperature -70 °C to +85 °C (-94 °F to +185 °F) General Specifications Brand HELIAX® Mechanical Specifications Bending Moment 3.8 N-m I 2.8 ft lb Flat Plate Crush Strength 110.0 lb/in I 2.0 kg/mm ©2013 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively,of CommScope. page 1 of 4 All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised:April 23, 2012 June 26,2013 Product Specifications coMMSC( PE- LDF4-50A POWERED fry ANDREW Minimum Bend Radius, Multiple Bends 127.00 mm I 5.00 in Minimum Bend Radius, Single Bend 50.80 mm I 2.00 in Number of Bends, minimum 15 Number of Bends, typical 50 Tensile Strength 113 kg I 250 lb Note Performance Note Values typical, unless otherwise stated Standard Conditions Attenuation, Ambient Temperature 20 °C I 68 °F Average Power, Ambient Temperature 40 °C I 104 °F Average Power, Inner Conductor Temperature 100 °C I 212 °F Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 806-960 MHz 1.13 24.30 1700-2000 MHz 1.13 24.30 ©2013 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively,of CommScope. page 2 of 4 All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised:April 23, 2012 June 26,2013 Product Specifications coMMSC( PE- LDF4-50A POWERED BY ANDREW Attenuation Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW) 0.5 0.149 0.045 40.00 1 0.211 0.064 36.11 1.5 0.259 0.079 29.46 2 0.299 0.091 25.50 10 0.672 0.205 11.35 20 0.954 0.291 7.99 30 1.172 0.357 6.51 50 1.521 0.463 5.02 88 2.031 0.619 3.76 100 2.169 0.661 3.52 108 2.256 0.688 3.38 150 2.673 0.815 2.85 174 2.887 0.88 2.64 200 3.103 0.946 2.46 300 3.835 1.169 1.99 400 4.462 1.36 1.71 450 4.749 1.447 1.61 500 5.021 1.53 1.52 512 5.085 1.55 1.50 600 5.533 1.686 1.38 700 6.009 1.831 1.27 800 6.456 1.968 1.18 824 6.56 1.999 1.16 894 6.855 2.089 1.11 960 7.124 2.171 1.07 1000 7.284 2.22 1.05 1250 8.226 2.507 0.93 1500 9.093 2.771 0.84 1700 9.744 2.97 0.78 1800 10.058 3.066 0.76 2000 10.666 3.251 0.72 2100 10.961 3.341 0.70 2200 11.251 3.429 0.68 2300 11.535 3.516 0.66 2500 12.09 3.685 0.63 2700 12.627 3.849 0.60 3000 13.407 4.086 0.57 3400 14.401 4.389 0.53 3700 15.118 4.608 0.50 4000 15.815 4.82 0.48 5000 18.01 5.489 0.42 6000 20.055 6.113 0.38 8000 23.826 7.262 0.32 8800 25.244 7.694 0.30 * Values typical, guaranteed within 5% Regulatory Compliance/Certifications Search Catalog Classification RoHS 2011/65/EU Compliant China RoHS SJ/T 11364-2006 Below Maximum Concentration Value (MCV) ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system ©2013 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively,of CommScope. page 3 of 4 All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised:April 23, 2012 June 26,2013 Product Specifications COMMSCLPE POWERED BY ANDREW L4TNM-PSA Type N Male Positive StopTM for 1/2 in AL4RPV-50, LDF4-50A, HL4RPV-50 cable This product is part of the CommScope Wired for Wireless® Solution General Specifications Interface N Male Body Style Straight Brand HELIAX® I Positive StopTM Harmonized System (HS) Code 854420 (Coaxial cable and other coaxial electric conductors) Mounting Angle Straight Ordering Note CommScope® standard product (Global) Electrical Specifications Connector Impedance 50 ohm Operating Frequency Band 0 - 8800 MHz Cable Impedance 50 ohm 3rd Order IMD, typical -116 dBm @ 910 MHz 3rd Order IMD Test Method Two +43 dBm carriers RF Operating Voltage, maximum (vrms) 707.00 V dc Test Voltage 2000 V Outer Contact Resistance, maximum 0.30 mOhm Inner Contact Resistance, maximum 2.00 mOhm Insulation Resistance, minimum 5000 MOhm Average Power 0.6 kW @ 900 MHz Peak Power, maximum 10.00 kW Insertion Loss, typical 0.05 dB Shielding Effectiveness -130 dB ©2015 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 2 of 4 All specifications are subject to change without notice.See www.commscope.com for the most current information. Revised:February 9,2015 August 14,2015 Product Specifications coMMsCL_PE° L4TNM-PSA L POWERED BY SSW J Outline Drawing MATES TO MI L—S1D-348, 304.2 OR EQUIVALENT 19.0mm WRENCH FLATS c . ,m — — — — (91&,Onr ) • Ne/11 3/96" WRENCH FLATS (78.7arnm) Mechanical Specifications Outer Contact Attachment Method Ring-flare Inner Contact Attachment Method Captivated Outer Contact Plating Trimetal Inner Contact Plating Silver Attachment Durability 25 cycles Interface Durability 500 cycles Interface Durability Method IEC 61169-16:9.5 Connector Retention Tensile Force 890 N I 200 lbf Connector Retention Torque 5.42 N-m I 48.00 in lb Insertion Force 66.72 N I 15.00 lbf Insertion Force Method MIL-C-39012C-3.12, 4.6.9 Coupling Nut Proof Torque 176.26 N-m I 1560.00 in lb Coupling Nut Retention Force 444.82 N I 100.00 lbf Coupling Nut Retention Force Method MIL-C-39012C-3.25, 4.6.22 Dimensions Nominal Size 1/2 in Diameter 22.35 mm I 0.88 in Length 76.70 mm I 3.02 in Weight 94.71 g I 0.21 lb ©2015 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 3 of 4 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:February 9,2015 August 14,2015 Product Specifications coMMsCL_PE° L4TNM-PSA POWERED sr I 10°'AND /11/J Environmental Specifications Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F) Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F) Immersion Depth 1 m Immersion Test Mating Unmated Immersion Test Method IEC 60529:2001, IP68 Water Jetting Test Mating Unmated Water Jetting Test Method IEC 60529:2001, IP66 Moisture Resistance Test Method MIL-STD-202F, Method 106F Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition I Thermal Shock Test Method MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C Vibration Test Method IEC 60068-2-6 Corrosion Test Method MIL-STD-1344A, Method 1001.1, Test Condition A Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 45-1000 MHz 1.02 39.00 1010-2200 MHz 1.03 37.00 2210-3000 MHz 1.05 33.00 3010-4000 MHz 1.09 27.00 4010-6000 MHz 1.25 19.00 6010-8000 MHz 1.33 17.00 Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant by Exemption China RoHS SJ/T 11364-2006 Above Maximum Concentration Value (MCV) ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system rn) * Footnotes Immersion Depth Immersion at specified depth for 24 hours Insertion Loss, typical 0.05v freq (GHz) (not applicable for elliptical waveguide) ©2015 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 4 of 4 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:February 9,2015 August 14,2015 Product Specifications 1114111127: DREW Environmental Specifications Corrosion Test Method MIL-STD-1344A, Method 1001.1,Test Condition A Immersion Depth 1 m Immersion Test Mating Unmated Immersion Test Method IEC 529:1989, IP68 Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition I Moisture Resistance Test Method MIL-STD-202F, Method 106F Operating Temperature -55 °C to+85°C (-67°F to+185 °F) Storage Temperature -55 °C to+85°C (-67°F to+185 °F) Thermal Shock Test Method MIL-STD-202F, Method 107G,Test Condition A-1, Low Temperature-55 °C Vibration Test Method IEC 68, Part 2-6 Water Jetting Test Mating Unmated Water Jetting Test Method IEC 529:1989, IP66 Standard Conditions Attenuation, Ambient Temperature 20°C ( 68 °F Average Power, Ambient Temperature 40°C I 104°F Return Loss Frequency Band Return Loss (dB) 45-1000 MHz 39.00 1010-2200 MHz 37.00 2210-3000 MHz 33.00 3010-4000 MHz 29.00 4010-6000 MHz 25.00 6010-8000 MHz 23.00 * Footnotes Immersion Depth Immersion at specified depth for 24 hours From North America,toll free Outside North America ©2007 Andrew Corporation,Westchester,IL 60154 US Telephone: 1-800-255-1479 Telephone:+1-708-873-2307 All designs,specifications,and availabilities of products and page 2 of 2 Fax: 1-800-349-5444 Fax:+1-779-435-8579 services presented are subject to change without notice 5/16/2007 Wireless Indoor Solutions RADIO FREQUENCY SYSTEMS I I I C L i e d I L I I U I l C RFS Lite Plenum - Rated Cables ClearFill®Line aluminum plenum-rated wideband coaxial cable offers a cost-effective, lighter weight alternative to copper cabling ETL tic Listed Cable ICA12-50JPLLW — 1/2" Diameter — Wideband — CMP Rated Radio Frequency Systems'(RFS) 1/2" aluminum plenum Exclusive Features rated wideband cable, tested up to 6 GHz, delivers outstanding electrical performance and supports all wireless in-building applications. A cost-effective alternative to copper cabling, it • Plenum-rated —CMP, ETL listed to UL444 maintains compatibility with existing connectors,tools —Meets the most stringent industry standards for and hanging hardware for easy and convenient installation. maximum safety ICA LITE is available in a white jacket(ICA12-50JPLLW) model. • Continuous (star-shaped) dielectric for total It utilizes the same Star-Dielectric Spline as RFS' popular inner conductor support ICA12-50JPL plenum-rated copper cables, providing uniform —Eliminates electrical or mechanical problems in support throughout the length of cable for superior tight bending areas; minimizes kinks performance by eliminating electrical and mechanical problems in tight bending areas. Additionally, the • Wideband Operation — Up to 6 GHz aluminum outer conductor minimizes system interference by —Suitable for all in-building applications for providing a continuous RFI/EMI shield and ICA LITE's UV- maximum flexibility resistant jacket allows it to withstand outdoor storage. • Maintains compatibility with existing All RFS wideband Y2" plenum cable offers outstanding connectors, tools and hanging hardware electrical performance and has met the most stringent plenum —Increases system flexibility and eases network cable standards for maximum safety, including CMP, ETL planning listed to UL444,and also comply with Canadian CSA C.22.2/FT6 standard,with low-flame-spread and low- • Lighter weight than copper smoke characteristics. Due to low attenuation, outstanding —Eases installation and reduces the number of heat transfer properties and temperature-stabilized dielectric hanging clamps materials, ICA LITE provides a safe, long-term operating life at high-transmit power levels. • Copper-clad center conductor with AL outer conductor Q RFS 1/2" plenum-rated cables -Provides good electrical performance meet the most stringent industry • UV resistant jacket for outdoor storage standards for maximum safety -Ensures product reliability • t i s i r • WIRELESS I MOBILE RADIO MICROWAVE I IN-TUNNEL I IN-BUILDING I TV & RADIO I HF & DEFENSE www.rfsworld.corn Product Data Sheet ICA12-50JPLLW -ff 1/2" ClearFill®Line Aluminum Plenum-Rated Air-Dielectric Coaxial Cable for In-Building Applications Product Description ClearFill®Line 1/2"low-loss air dielectric cable,Plenum-rated,CMP Application: Plenum In-Building p / I 1/2"Aluminum Plenum-Rated In-Building Cable Features/Benefits • Supports Multiple RF Signals Frequency Attenuation Power • Complete Shielding [MHz] [dB/100m [dB/100ft] [kW] The solid outer conductor of the ClearFill®Line coaxial cable creates a continuous RFI/EMI shield that ] minimizes system interference. 0.5 0.148 0.045 21,4 • Outstanding Intermodulation Performance 1 0.213 0.065 21,4 RFS coaxial cable's solid inner and outer conductors virtually eliminate intermods. 1,5 0.259 0.07921.4 Intermodulationperformance is also confirmed with state-of-the-art equipment at the 2 0.679 0.091 21,4 10 0.679 0.207 21,4 RFS factory. 20 0.965 0.294 16,4 • Wide Range of Applications 30 1.19 0.363 13,3 Typical areas of application are:feedlines for plenum-space installations within occupied buildings or 50 1.55 0.472 11.8 structures 88 2.08 0.635 7.66 100 2.23 0.679 7.16 108 2.32 0.708 6.89 i Technical Features 150 2.77 0.843 5.36 174 2.99 0.912 5.36 Structure 200 3.23 0.983 4.98 Inner conductor: Copper-Clad Aluminum Wire [mm(in)] 4.8(0.19) 300 4.04 1.23 3.45 400 4.72 1.44 3.45 Dielectric: Extruded Polyethylene [mm(in)] 11.8(0.464) 450 5.02 1.53 3.24 Outer conductor: Corrugated Aluminum [mm(in)] 13.8(0.54) 500 5.35 1.63 3 Jacket: Plenum Rated/color white [mm(in)] 15.93(0.627) 512 5.41 1.65 2.8 Mechanical Properties 600 5.91 1.8 2.77 700 6.46 1.97 2.55 Weight,approximately [kg/m(Ib/ft)] 0.19(0.13) 800 6.96 2.2 2.36 Minimum bending radius,single bending [mm(in)] 125(5) 824 7.09 2.16 2.33 Minimum bending radius,repeated bending [mm(in)] 254(10) 894 7.41 2.26 2.22 Bending moment [Nm(lb-ft)] 5.4(4) 960 7.74 2.36 2.14 Max.tensile force [N(Ib)] 549(150) 1000 7.91 2.41 2.09 Recommended/maximum clamp spacing [m(ft)] 0.5/0.9(1.8/3) 1250 2.75 1.85 1500 100.0.0 4 3.06 1..77 Electrical Properties 1700 10.83 3.3 1.55 Characteristic impedance [n] 50+/-1 1800 11.22 3.42 1.46 Relative propagation velocity [%] 91 2000 11.94 3.64 1.41 Capacitance [pF/m(pF/ft)] 75(22.86) 2100 1 3.75 1.37 2200 12..6 6 6 3.86 1.35 Inductance [pH/m(pH/ft)] 0.19(0.058) 2300 13.02 3.97 1.32 0, Max.operating frequency [GHz] 6 2500 13.68 4.17 1.25 t Jacket spark test RMS [V] 8000 2700 14.37 4.38 1.11 `o Peak power rating [kW] 21.4 3000 15.32 4.67 1.05 6 RF Peak voltage rating [V] 1500 3400 16.6 5.06 1 [0/km(n/1000ft)] 1.48(0.45) 3700 17.49 5.33 0.9 E DC-resistance inner conductor 4000 18.41 5.61 0.8 TO DC-resistance outer conductor [4/km(0/1000ft)] 2.29(0.7) 5000 21.23 6.47 0.4 c ° Recommended Temperature Range 6000 23.92 7.29 0.1 1,1Attenuation at 20°C(68°F)cable temperature E Storage temperature [°C(°F)] -40 to 85(-40 to 185) Mean power rating at 40°C(104°F)ambient temperature Installation temperature [°C(°F)] -20 to 60(-4 to 140) o Operation temperature [°C(°F)] -40 to 85(-40 to 185) d Other Characteristics yFire Performance: Flame Retardant,Plenum-rated,CMP Iq Regulatory NEC Article 800 Communication Circuits y Compliance: ETL Listed to UL444 m m Canadian CSA C.22.2/FT6 v VSWR Performance: 19.0(1.25)@ 806-960,1700-2155 [dB(VSWR)] Z 0 o Other Options: 0. 0 t G 0 d c 2 c 0 O C O .9 O C RFS The Clear Choice® ICA12-50JPLLW Rev:A/28.Jan.2014 Please visit us on the internet at htto://www.rfsworld.com/ Radio Frequency Systems Product Data Sheet LCF12-50J .2 1/2" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable Product Description CELLFLEX®1/2"low loss flexible cable Application: OEM jumpers,Main feed transitions to equipment,GPS lines 1/2"CELLFLEX®Low-Loss Foam Dielectric Coaxial Cable Features/Benefits • Low Attenuation Frequency Attenuation Power The low attenuation of CELLFLEX®coaxial cable results in highly efficient signal transferin your RF [MHz] [dB/100m [dB/100ft] [kW] system. ] • Complete Shielding 0.5 0.149 0.0454 38.0 The solid outer conductor of CELLFLEX®coaxial cable creates a continuous RFI/EMI shield that minimizes 1.0 0.211 0.0643 38.0 system interference. 1.5 0.258 0.0788 32.9 • Low VSWR 2.0 0.298 0.0910 28.5 10 0.671 0.204 12.7 Special low VSWR versions of CELLFLEX®coaxial cables contribute to low system noise. 20 0.951 0.290 8.93 • Outstanding Intermodulation Performance 30 1.17 0.356 7.26 CELLFLEX®coaxial cable?s solid inner and outer conductors virtually eliminate intermods.Intermodulation 50 1.51 0.462 5.63 performance is also confirmed with state-of-the-art equipment at the RFS factory. 88 2.02 0.616 4.21 • HiHigh Power Rating100 2.16 0.658 3.93 9 108 2.24 0.684 3.79 Due to their low attenuation,outstanding heat transfer properties and temperature stabilized dielectric 150 2.66 0.810 3.19 materials,CELLFLEX®cable provides safe long term operating life at high transmit power levels. 174 2.87 0.875 2.96 • Wide Range of Application 200 3.08 0.940 2.76 Typical areas of application are:feedlines for broadcast and terrestrial microwave antennas,wireless 300 3.81 1.16 2.23 cellular,PCS and ESMR base stations,cablingof antenna arrays,and radio equipment interconnects. 400 4.43 1.35 1.92 450 4.71 1.44 1.80 Technical Features 500 4.98 1.52 1.71 512 5.04 1.54 1.69 Structure 600 5.48 1.67 1.55 Inner conductor: Copper-Clad Aluminum Wire [mm(in)] 4.8(0.19) 700 5.95 1.81 1.43 Dielectric: Foam Polyethylene [mm(in)] 11.9(0.47) 750 6.17 1.88 1.38 Outer conductor: Corrugated Copper [mm(in)] 13.8(0.54) 800 6.39 1.95 1.33 Jacket: Polyethylene,PE [mm(in)] 15.8(0.62) 824 6.49 2.07 1.31 894 6.78 2.07 1.25 Mechanical Properties 900 6.80 2.07 1.25 Weight,approximately [kg/m(lb/ft)] 0.2(0.14) 925 6.90 2.10 1.23 Minimum bending radius,single bending [mm(in)] 70(3) 960 7.04 2.15 1.21 1000 7.20 2.19 1.18 Minimum bending radius,repeated bending [mm(in)] 125(5) 1250 8.12 2.48 1.05 Bending moment [Nm(lb-ft)] 6.5(4.79) 1400 8.64 2.63 0.983 Max.tensile force [N(Ib)] 1100(247) 1500 8.97 2.73 0.947 Recommended/maximum clamp spacing [m(ft)] 0.6/1(2/3.25) 1700 9.61 2.93 0.884 E Electrical Properties 1800 9.91 3.02 0.857 `� 2000 10.5 3.20 0.809 0 o Characteristic impedance [n] 50+/-1 2100 10.8 3.29 0.787 o Relative propagation velocity IN 88 2200 11.1 3.38 0.765 E Capacitance [pF/m(pF/ft)] 76(23.2) 2400 11.6 3.54 0.732 Inductance [pH/m(pH/ft)] 0.19(0.058) 2500 11.9 3.62 0.714 m 2600 12.2 3.70 0.696 o Max.operating frequency [GHz] 8.8 IJacket spark test RMS [V] 8000 2700 12.4 3.78 0.644 Peakpower rating [kW] 38 3500 13.2 4.018 0.644 �� 3500 14.4 4.38 0.590 g RF Peak voltage rating [V] 1950 4000 15.5 4.72 0.548 o DC-resistance inner conductor [0/km(0/1000ft)] 1.57(0.48) 5000 17.6 5.37 0.483 d DC-resistance outer conductor [O/km(0/1000ft)] 2.7(0.82) 6000 19.6 5.97 0.433 Recommended Temperature Range 7000 21.4 6.54 0.397 y p 9 8000 23.2 7.07 0.366 2 Storage temperature [°C(°F)] -70 to 85(-94 to 185) 8800 24.6 7.49 0.345 t Installation temperature [°C(°F)] -40 to 60(-40 to 140) Attenuation at 20°C(68°F)cable temperature 2 Operation temperature [°C(°F)] -50 to 85(-58 to 185) Mean power rating at 40°C(104°F)ambient temperature m Other Characteristics y Fire Performance: Halogene Free o Contact RFS for your VSWR performance specification for G VSWR Performance: Standard [dB(VSWR)] your required frequency -o band. .5 Other Options: Phase stabilized and phase matched cables and assemblies are available upon request. c 0 U C O 12 O C • RFS The Clear Choice® LCF12-50J Rev:D/15.Aug.2013 Print Date:17.12.2013 Please visit us on the internet at htto://www.rfsworld.com/ Radio Frequency Systems Product Data Sheet NM-LCF12-0O2 N Male Connector for 1/2" Coaxial Cable, OMNI FITTM standard Product Description OMNI FITT"' high performance connectors are designed for use with both CELLFLEX®(copper) and CELLFLEX®Lite(aluminum)cables.They are designed specifically to provide the highest quality connector-cable interface while simplifying and speeding up connector attachment.All RFS connectors are fully tested for mechanical and electrical compliance to industry specifications. OMNI FITT'Standard Connectors Features/Benefits • Cost effective two-piece design for safe and easy installation • Compatible with copper and aluminium cable types i.e.one connector for both outer conductor materials eliminates the risk of faulty connector installation and helps to keep inventory down • Robust mechanical design for low and consistent intermodulation performance i.e.keeps the mobile network performance up reduces the number of dropped calls and avoids revenue losses • Superior electrical performance for consistent and repeatable VSWR i.e.ensure network system performance • Waterproof to IP 68 i.e.no downtime risk,secures revenue • RoHS(EU)and CRoHS(China)compliant i.e.can be used on a global basis Technical Specifications Transmission Line Type Coaxial Cable Cable Size 1/2" Cable Type Foam Dielectric,Radiating Model Series LCF12-50 Series Connector Interface N Nominal Impedance,ohms 50 Connector Type OMNI FITT"' Standard Sealing Method 0-ring Gender Male Plating Outer/Inner Trimetal/Silver Length,mm(in) 58.7(2.31) Outer Diameter,mm(in) 25.9(1) Weight,kg(Ib) 0.12(0.26) Inner Contact Attachment Basket Outer Contact Attachment Spring C-Ring 3rd Order IM Product @ 2x20 Watts,dBc -159 typical Maximum Frequency,GHz 6 VSWR(Return Loss,dB) 0<f=1.0 GHz: 1.030(36.6) 1.0<f=2.7 GHz: 1.040(34.1) 2.7<f=3.7 GHz: 1.080(28.3) ▪ Wrench size front,mm(in) 24(15/16) Wrench size rear,mm(in) 24(15/16) 8 Waterproof Level IP68 Notes s Other Documentation y Application Note: 10000009163-01_Application Note_Installation of Heat Shrink Sleeves for additional sealing of Connectors.pdf Installation instruction: 10000009476-02.pdf a d a a a C O O O C, E O C • RFS The Clear Choice® NM-LCF12-0O2 Rev:F/03.Mar.2015 Print Date:14.08.2015 Please visit us on the internet at htto://www.rfsworld.com/ Radio Frequency Systems Product Data Sheet NM-LCF12-0O2 N Male Connector for 1/2" Coaxial Cable, OMNI FITTM standard III LOILMAI I■r.�� repi �� 0 0 N E 42 0 E O U O d J N � N t0 N N d N U N C O O C, E O C RFS The Clear Choice® NM-LCF12-0O2 Rev:F/03.Mar.2015 Print Date:14.08.2015 Please visit us on the internet at htto://www.rfsworld.com/ Radio Frequency Systems OO TIMES MICROWAVE SYSTEMS LMR®-400 fg Flexible Low Loss Communications Coax EIdeal for... • Drop-in replacement for RG-8/9913 Air-Dielectric type Cable i>° • Jumper Assemblies in Wireless Communications Systems �a4 • Short Antenna Feeder runs • Any application (e.g. WLL, GPS, LMR, WLAN, WISP, WiMax, SCADA, Mobile Antennas) requiring an easily routed, , low loss RF cable • LMR®standard is a UV Resistant Polyethylene jacketed Size for size LMR has the lowest loss of any flexible cable cable designed for 20-year service outdoor use. The and comparable loss to semirigid hard-line cables. bending and handling characteristics are significantlybetter • RF Shielding is 50 dB greater than typical single than air-dielectric and corrugated hard-line cables. shielded coax(40 dB). The multi-ply bonded foil outer • LMR®-DB is identical to standard LMR plus has the conductor is rated conservatively at>90 dB(i.e.>180 advantage of being watertight. The addition of dB between two adjacent cables). waterproofing compound in and around the foil/braid • Weatherability: LMR-400 cables designed for insures continuous reliable service should the jacket be outdoor exposure incorporate the best materials for UV inadvertently damaged during installation or in the future. resistance and have life expectancy in excess of 20 years. • LMR®-FR is a non-halogen(non-toxic),low smoke, • Connectors:Awide variety of connectors are available fire retardant cable designed for in-building runs that can for LMR-400 cable,including all common interface types, be routed anywhere except air handling plenums. reverse polarity, and a choice of solder or non-solder LMR-FR is UL/NEC & CSA rated'CMR' and `FT4' center pins. Most LMR connectors employ crimp outer respectively,meets FAA FAR25 requirements and is attachment using standard hex crimp sizes. MSHA-P for mining operations. • Cable Assemblies: All LMR-400 cable types are • LMR®- FR-PVC is a general-purpose indoor cable available as pre-terminated cable assemblies. Refer to and has a UL/NEC&CSA rating of'CMR'and `FT4' the section on FlexTech for further details. respectively.It is less expensive than LMR-FR,however Part Description Stock it emits toxic fumes (HCL) and greater smoke density Part Number Application Jacket Color Code when burned. LMR-400 Outdoor PE Black 54001 • LMR®-PVC is designed for low loss general-purpose LMR-400-DB Outdoor/Watertight PE Black 54091 LMR-400-FR Indoor-RiserCMR FRPE Black 54030 applications and is somewhat more flexible LMR-400-FR-PVC Indoor-RiserCMR FRPVC Black 54073 than the standard polyethylene jacketed LMR. LMR-400-PVC General Purpose PVC Black 54218 • LMR®-PVC-W is a white jacketed version of LMR- LMR-400-PVC-W General Purpose PVC White 54204 PVC for marine and other applications where color compatibility is desired. Construction Specifications • Flexibility andbendability are hallmarks of the LMR- Description Material In. (mm) 400 cable design.The flexible outer conductor enables Inner Conductor Solid BCCAI 0.108 (2.74) the tightest bend radius available for any cable of similar Dielectric Foam PE 0.285 (7.24) Outer Conductor Aluminum Tape 0.291 (7.39) size and performance. Overall Braid Tinned Copper 0.320 (8.13) • Low Loss is another hallmark feature of LMR-400. Jacket (see table above) 0.405 (10.29) 22 (800)TMS-COAX • www.timesmicrowave.com Irl-IMEs MICROWAVE SYSTEMS O r O Mechanical Specifications Electrical Specifications I �0 Performance Property Units US (metric) Performance Property Units US (metric) ce 0,,c, Bend Radius: installation in. (mm) 1.00 (25.4) Velocity of Propagation % 85 Bend Radius: repeated in. (mm) 4.0 (101.6) Dielectric Constant NA 1.38 Bending Moment ft-lb(N-m) 0.5 (0.68) Time Delay nS/ft(nS/m) 1.20 (3.92) Weight lb/ft(kg/m) 0.068 (0.10) Impedance ohms 50 Tensile Strength lb(kg) 160 (72.6) Capacitance pF/ft(pF/m) 23.9 (78.4) Inductance uH/ft(uH/m) 0.060 (0.20) Flat Plate Crush lb/in. (kg/mm) 40 (0.71) Shielding Effectiveness dB >90 DC Resistance Inner Conductor ohms/1000ft(/km) 1.39 (4.6) Environmental Specifications Outer Conductor ohms/1000ft(/km) 1.65 (5.4) Performance Property °F °C Voltage Withstand Volts DC 2500 Installation Temperature Range -40/+185 -40/+85 Jacket Spark Volts RMS 8000 Storage Temperature Range -94/+185 -70/+85 Peak Power kW 16 Operating Temperature Range -40/+185 -40/+85 Attenuation vs. Frequency (typical) ll10•0 a- 1.0 0.1 10 100 1,000 10,000 Frequency(MHz) Frequency (MHz) 30 50 150 220 450 900 1500 1800 2000 2500 5800 Attenuation dB/100 ft 0.7 0.9 1.5 1.9 2.7 3.9 5.1 5.7 6.0 6.8 10.8 Attenuation dB/100 m 2.2 2.9 5.0 6.1 8.9 12.8 16.8 18.6 19.6 22.2 35.5 Avg. Power kW 3.33 2.57 1.47 1.20 0.83 0.58 0.44 0.40 0.37 0.33 0.21 Calculate Attenuation= (0.122290)• FMHz + (0.000260)• FMHz(interactive calculator available at http://www.timesmicrowave.com/cable_calculators) Attenuation: VSWR=1.0 ;Ambient= +25°C(77°F) Power: VSWR=1.0;Ambient= +40°C; Inner Conductor= 100°C(212°F); Sea Level; dry air; atmospheric pressure; no solar loading (800)TMS-COAX • www.timesmicrowave.com 23 OTIMEs MICROWAVE SYSTEMS LMR®-400 Flexible Low Loss Communications Coax r Alpe V. %I.' :41Ir SC-400-NM x. TC-400-NM TC-400-NMC EZ-400-NMH-D TC-400-NMH-D TC-400-N MH-RA-D TC-400-NMC-RA(A) EZ-400-N M H-RA ti EZ-400-NMK41;.. IMO - > ilr TC-400-NM-RP 411' EZ-400-NMC-2 cAI Connectors TC-400-NFC Inner Outer Finish* Part Stock VSWR** Coupling Contact Contact Body Length Width Weight nterface Description Number Code Freq. (GHz) Nut Attach Attach /Pin in (mm) in (mm) lb(g) 7-16 DIN Female Straight Jack TC-400-716-FC 3190-376 <1.25:1 (2.5) NA Solder Clamp S/S 1.6 (41) 1.13 (28.7) 0.281 (127.5) 7-16 DIN Male Straight Plug EZ-400-716M 3190-2524 <1.25:1 (6) Hex Spring Finger Crimp NG 1.6 (39.5) 1.38 (35) 0.277 (126.0) 7-16 DIN Male Straight Plug TC-400-716-MC 3190-279 <1.25:1 (2.5) Hex Solder Clamp S/S 1.4 (36) 1.40 (35.6) 0.268 (121.6) 7-16 DIN Male Right Angle TC-400-716MC-RA 3190-1671 <1.25:1 (<3) Hex Solder Clamp NS 2.4 (61.5) 1.88 (47.8) 0.35 (159) 7-16DIN Male Right Angle EZ-400-716M-RA 3190-2545 <1.35:1 (6) Hex Spring Finger Crimp A/G 1.6 (41.7) 1.75 (44.3) 0.374 (0.17) BNC Male Straight Plug TC-400-BM 3190-318 <1.25:1 (2.5) Knurl Solder Crimp N/S 1.7 (43) 0.56 (14.2) 0.063 (28.6) HN Male Straight Plug TC-400-HNM 3190-923 <1.25: (<1) Knurl Solder Clamp S/G 2.3 (59.2) 0.88 (22.4) 0.25 (113.4) HN Male Right Angle TC-400-HNM-RA 3190-2541 <1.25:1 (2.5) Hex Solder Crimp NG 1.6 (41.4) 1.56 (39.6) 0.198 (90.0) QDS Male Straight Plug TC-400-QDSM 3190-620 <1.25: (<3) Knurl Solder Clamp A/G 1.8 (46.6) 1.00 (25.4) 0.25 (113.4) Mini-UHF Straight Plug TC-400-MUHF 3190-520 <1.25:1 (2.5) Knurl Solder Crimp N/G 1.1 (28) 0.50 (12.7) 0.020 (9.1) N Female Straight Jack TC-400-NFC 3190-299 <1.25:1 (2.5) NA Solder Clamp N/S 1.6 (41) 0.75 (19.1) 0.119 (54.0) Straight Jack EZ-400-NFC-2 3190-1907 <1.25:1 (2.5) NA Spring Finger Clamp N/G 1.5 (38) 0.89 (22.6) 0.121 (54.9) Straight Jack EZ-400-NF 3190-956 <1.25:1 (2.5) NA Spring Finger Crimp N/G 1.8 (45) 0.66 (16.8) 0.105 (47.6) Straight Jack TC-400-NF 3190-2255 <1.25:1 (2.5) NA Solder Crimp N/G 1.8 (45) 0.66 (16.8) 0.105 (47.6) Bulkhead Jack EZ-400-NF-BH 3190-518" <1.25:1 (2.5) NA Spring Finger Crimp N/G 1.8 (46) 0.88 (22.4) 0.102 (46.3) Bulkhead Jack TC-400-NFC-BH(A) 3190-872 <1.25:1 (2.5) NA Solder Clamp NG 1.8 (46) 0.88 (22.4) 0.145 (65.8) N Male Straight Plug SC-400-NM 3190-1454 <1.25:1 (2.5) Knurl Solder Crimp N/G 1.5 (38) 0.75 (19.1) 0.090 (40.8) Straight Plug TC-400-NM 3190-188 <1.25:1 (2.5) Knurl Solder Crimp N/G 1.5 (38) 0.75 (19.1) 0.090 (40.8) Straight Plug TC-400-NMC 3190-277 <1.25:1 (2.5) Knurl Solder Clamp N/G 1.5 (38) 0.70 (17.8) 0.121 (54.9) Straight Plug EZ-400-NMC-2 3190-1906 <1.25:1 (2.5) Hex/KnurlSpring Finger Clamp N/G 1.5 (38) 0.75 (19.1) 0.121 (54.9) Straight Plug EZ-400-NMH-D 3190-400" <1.25:1 (10) Hex/KnurlSpring FingerCrimp NG 1.5 (38) 0.89 (22.6) 0.103 (46.8) Straight Plug TC-400-NMH-D 3190-552 <1.25:1 (10) Hex/Knurl Solder Crimp NG 1.5 (38) 0.89 (22.6) 0.113 (51.3) Straight Plug EZ-400-NMK 3190-661 <1.25:1 (10) Knurl Spring FingerCrimp S/G 1.5 (38) 0.75 (22.6) 0.113 (51.3) Right Angle TC-400-NMH-RA-D 3190-2293" <1.35:1 (6) Hex/Knurl Solder Crimp A/G 1.8 (46) 1.25 (31.8) 0.130 (59.0) Right Angle TC-400-NMC-RA(A) 3190-870 <1.35:1 (2.5) Hex Solder Clamp NG 1.8 (46) 1.25 (31.8) 0.150 (68.0) Right Angle EZ-400-NMH-RA 3190-761 <1.35:1 (2.5) Hex Spring Finger Crimp S/G 1.8 (46) 1.25 (31.8) 0.130 (59.0) Reverse Polarity TC-400-NM-RP 3190-960 <1.25:1 (2.5) Knurl Solder Crimp N/G 1.5 (38) 0.75 (19.1) 0.090 (40.8) SMA Male Straight Plug TC-400-SM 3190-439 <1.25:1 (8) Hex Solder Crimp N/G 1.2 (29) 0.50 (12.7) 0.032 (14.5) TNC Female Reverse Polarity TC-400-TF-RP 3190-1063 <1.25:1 (2.5) NA Solder Crimp N/G 1.8 (46) 0.55 (14.0) 0.074 (33.6) Reverse Polarity EZ-400-TF-RP 3190-795 <1.25:1 (2.5) NA Spring Finger Crimp NG 1.8 (46) 0.55 (14.0) 0.074 (33.6) TNC Male Straight Plug TC-400-TM 3190-260 <1.25:1 (2.5) Knurl Solder Crimp N/S 1.7 (43) 0.59 (15.0) 0.074 (33.6) Straight Plug TC-400-TM-D 3190-2532 <1.25:1 (6) Hex/Knurl Solder Crimp NG 1.9 (48) 0.67 (17.5) 0.075 (34.3) Straight Plug EZ-400-TM-D 3190-2533 <1.25:1 (6) Hex/Knurl Spring Finger Crimp NG 1.9 (48) 0.67 (17.5) 0.075 (34.3) Straight Plug EZ-400-TM 3190-650 <1.25:1 (2.5) Knurl Spring Finger Crimp N/S 1.7 (43) 0.59 (15.0) 0.074 (33.6) Right Angle TC-400-TM-RA 3190-442" <1.35:1 (2.5) Knurl Solder Crimp N/G 1.7 (43) 0.59 (15.0) 0.085 (38.6) Reverse Polarity TC-400-TM-RP 3190-1062 <1.25:1 (2.5) Knurl Solder Crimp N/G 1.7 (43) 0.59 (15.0) 0.074 (33.6) Reverse Polarity EZ-400-TM-RP 3190-794 <1.25:1 (2.5) Knurl Spring Finger Crimp NG 1.7 (43) 0.59 (15.0) 0.074 (33.6) UHF Male Straight Plug EZ-400-UM 3190-997 <1.25:1(2.5) Knurl Spring Finger Crimp N/G 1.9 (48) 0.80 (20.3) 0.090 (40.8) 24 *Finish metals:N=Nickel,S=Silver,G=Gold,SS=Stainless Steel,A=Alballoy **VSWR spec based on 3 foot cable with a connector*Available in bulk pack (800)TMS-COAX • www.timesmicrowave.com TIMES MICROWAVE SYSTEMS 0 0 11* , y • Pr_ 0 glio like . Vce ' F '• 4 01 EZ-400-NF EZ-400-NF-BH TC-400-NFC-BH(A) TC-400-TM EZ-400-716M 0.0 C— TC-400-TM-RA 111 . p MI � rer,mss►-- �' colloAlli '.4V' kti F • TC-400-TM-RP TC-400-TF-RP EZ-400-TM - EZ-400-TM-RP EZ-400-TF-RP TC-400-TM-D AP4 i(- el. . r 1 -1 r TC-400-SM TC-400-BM TC-400-MUHF EZ-400-UM TC-400-HNM-RA • 10 } t cies,s 111 TC-400-716FC - TC-400-HNM TC-400-QDSM EZ-400-716M-RA TC-400-716MC t r '"' HG-400T Hardware Accessories gblioGK-S400TT Part Stock Type Number Code Description Ground Kit GK-S400TT GK-S400TT Standard Grounding Kit(each) Hoisting Grip HG-400T HG-400T Laced Type(each) HX-4 04 * RB-456 • ST-400C-2 GST-400 FL Illii , x CCT-01 4. 0010 Pirl-- CR-400 CT-400/301; , CST-400 TK-400EZ DBT-U TK-400-EZ Install Tools Part Stock Type Number Code Description Crimp Tool HX-4 3190-200 Crimp Handle Crimp Dies Y1719 3190-202 .429"Hex Dies Crimp Tool CT-400/300 3190-666 Crimp tool for LMR 400 connectors Crimp Rings CR-400 3190-830 Crimp rings for TC/EZ-400 connectors(package of 10) Strip Tool ST-400C-2 3190-1972 Prep tool for EZ-400-NMC-2 two piece clamp style connector Strip Tool CST-400 3192-004 Combination prep tool for LMR-400 crimp and clamp style connectors Mid-Span Strip Tool GST-400 3190-2174 For ground strap attachment Replacement Blades RB-456 3190-421 Replacement blades for Strip Tool Deburr Tool DBT-U 3192-001 Removes center conductor rough edges Cutting Tool CCT-01 3190-1544 Cable end flush cut tool Replacement Blade RB-01 3190-1609 Replacement blade for cutting tool Tool Kit TK-400EZ 3190-1601 Tool kit for LMR-400 Crimp Connectors(includes CCT-01,CST-400, CT-400/300,Tool Pouch) (800)TMS-COAX • www.timesmicrowave.com 25 o o 7flM ES MICROWAVE SYSTEMS LMR°-600 et Flexible Low Loss Communications Coax MIdeal for... • Jumper Assemblies in Wireless Communications Systems 1` NIs � ° ts • Short Antenna Feeder runs0 • Any application (e.g. WLL, GPS, LMR, WLAN, WISP WiMax, ti SCADA, Mobile Antennas) requiring an easily routed, low loss RF cable 0,fp." • LMR®standard is a UV Resistant Polyethylene jacketed Size for size LMR has the lowest loss of any flexible cable cable designed for 20-year service outdoor use. The and comparable loss to semirigid hard-line cables. bending andhandling characteristics are significantly better • RF Shielding is 50 dB greater than typical single than air-dielectric and corrugated hard-line cables. shielded coax(40 dB). The multi-ply bonded foil outer • LMR®-DB is identical to standard LMR plus has the conductor is rated conservatively at>90 dB(i.e.>180 advantage of being watertight. The addition of dB between two adjacent cables). waterproofing compound in and around the foil/braid • Weatherability: LMR-600 cables designed for insures continuous reliable service should the jacket be outdoor exposure incorporate the best materials for UV inadvertently damaged during installation or in the future. resistance and have life expectancy in excess of 20 years. • LMR®-FR is a non-halogen(non-toxic),low smoke, • Connectors:A wide variety of connectors are available fire retardant cable designed for in-building runs that can for LMR-600 cable,including all common interface types, be routed anywhere except air handling plenums. reverse polarity, and a choice of solder or non-solder LMR-FR is UL/NEC & CSA rated'CMR'and `FT4' center pins. Most LMR connectors employ crimp outer respectively,meets FAA FAR25 requirements and is attachment using standard hex crimp sizes. MSHA-P for mining applications. • Cable Assemblies: All LMR-600 cable types are • LMR®-FR-PVC is a general-purpose indoor cable available as pre-terminated cable assemblies. Refer to and has a UL/NEC&CSA rating of`CMR'and`FT4' the section on FlexTech for further details. respectively.It is less expensive than LMR-FR,however it emits toxic fumes(HCL)and greater smoke density Part Description Stock When burned. Part Number Application Jacket Color Code LMR-600 Outdoor PE Black 54003 • LMR®-PVC is designed for low loss general-purpose LMR-600-DB Outdoor/Watertight PE Black 54093 applications and is somewhat more flexible LMR-600-FR Indoor/Outdoor Riser CMR FRPE Black 54032 than the standard polyethylene jacketed LMR. LMR-600-FR-PVC Indoor/Outdoor Riser CMR FRPVC Black 54074 • LMR®-PVC-W is a white jacketed version of LMR- LMR-600-PVC General Purpose PVC Black 54219 PVC for marine and other applications where color LMR 600 PVC W General Purpose PVC White 54206 compatibility is desired. Construction Specifications • Flexibility and bendability are hallmarks ofthe LMR- Description Material In. (mm) 600 cable design.The flexible outer conductor enables Inner Conductor Solid BCCAI 0.176 (4.47) the tightest bend radius available for any cable of similar Dielectric Foam PE 0.455 (11.56) size and performance. Outer Conductor Aluminum Tape 0.461 (11.71) • Low Loss is another hallmark feature of LMR-600. Overall Braid Tinned Copper 0.490 (12.45) Jacket (see table above) 0.590 (14.99) 28 (800) TMS-COAX • www.timesmicrowave.com 7rT I ME S MICROWAVE SYSTEMS o Mechanical Specifications Electrical Specifications (10 Performance Property Units US (metric) Performance Property Units US (metric) 1 44 Ce def cam° Bend Radius: installation in. (mm) 1.50 (38.1) Velocity of Propagation % 87 e. 0 Bend Radius: repeated in. (mm) 6.0 (152.4) Dielectric Constant NA 1.32 -., 2 Bending Moment ft-lb(N-m) 2.75 (3.73) Time Delay nS/ft(nS/m) 1.17 (3.83) Weight lb/ft(kg/m) 0.131 (0.20) Impedance ohms 50 Tensile Strength lb(kg) 350 (158.9) Capacitance pF/ft(pF/m) 23.4 (76.6) Inductance uH/ft(uH/m) 0.058 (0.19) Flat Plate Crush lb/in.(kg/mm) 60 (1.07) Shielding Effectiveness dB >90 DC Resistance Environmental Specifications Inner Conductor ohms/1000ft(/km) 0.53 (1.7) Outer Conductor ohms/1000ft(/km) 1.2 (3.9) Performance Property °F °C Voltage Withstand Volts DC 4000 Installation Temperature Range -40/+185 -40/+85 Jacket Spark Volts RMS 8000 Storage Temperature Range -94/+185 -70/+85 Peak Power kW 40 Operating Temperature Range -40/+185 -40/+85 Attenuation vs. Frequency (typical) 10.0 c- 0 N ..; CU 0 1.0 c � Q d ... a- 0.1 __ , 10 100 1,000 10,000 Frequency(MHz) Frequency (MHz) 30 50 150 220 450 900 1500 1800 2000 2500 5800 Attenuation dB/100 ft0.4 0.5 1.0 1.2 1.7 2.5 3.3 3.7 3.9 4.4 7.3 Attenuation dB/100 m1.4 1.8 3.2 3.9 5.6 8.2 10.9 12.1 12.8 14.5 23.8 Avg. Power kW 5.51 4.24 2.41 1.97 1.35 0.93 0.70 0.63 0.59 0.52 0.32 Calculate Attenuation= (0.075550)• FMHz + (0.000260)• FMHz(interactive calculator available at http://www.timesmicrowave.com/cable_calculators) Attenuation: VSWR=1.0;Ambient=+25°C(77°F) Power: VSWR=1.0;Ambient=+40°C; Inner Conductor= 100°C(212°F); Sea Level;dry air; atmospheric pressure; no solar loading (800) TMS-COAX • www.timesmicrowave.com 29 o - O 7rTIM ES MICROWAVE SYSTEMS 9 LMR®-600 ce Flexible Low Loss Communications Coax E11 2 !!! 3 y 5 Y. * "rt - e lc } EZ-600- 7 6MC • 78EIA TC-600-716FC \, EZ-600-716M-X TC-600-716M-X • e 3190-1373, 3190-375 3190-2643 3190-2642 3190-502 67 = 8 9 10 TC-600-716M-RA-D •(0 _ 3190-2599 • • Y EZ-600-716M-RA-X L " -- EZ-600-716F TC-600-HNMC TC-600-LCM 3190-2546 3190-2447 3190-1429 3190-1406 11 12 13 14 15 .�"- h r r. '� TC-600-NF-X %.'. EZ-600-NF-X +EZ-600-NF-BH TC-600-NF-BH /TC-600-NFC-BH 3190-2816 3190-2817 3190-616 3190-589 3190-466 16 17 0115 18 19 0 20 PI VASS& .4./P0 fiMgal EZ-600-NMK EZ-600-NMC-2-D TC-600-NMC EZ-600-NMH-X -600-NMH-X 3190-669 3190-2641 3190-357 3190-2627 .3190-2628 21 EZ-600-NMH-RA-X 22TC-600-NMH-RA-D 23 24 25/26 3190-2639 3190-2427c. It,0 60111001eX all el; = 3190-2530 �TC-600-NMH-75-50 TC-600-QDSM EZ-600-TM-X 3190-1610 3190-825 3190-2531 Connectors Inner Outer Finish* Part Stock VSWR**Coupling Contact Contact Body Length Width Weight Interface Descri.tion Number Code Fre.. GHz Nut Attach Attach /Pin in mm in mm lb 1.7/8 EIA Flange EZ-600-78EIA 3190-1373 <1.25:1 (2.5) NA Spring Finger Clamp S/S 2.3 (58) 2.60 (66.0) 0.873(396.0) 2.7-16 DIN Female Straight Jack TC-600-716FC 3190-375 <1.25:1 (2.5) NA Solder Clamp S/S 1.1 (28) 1.00 (25.4) 0.249 (112.9) 3.7-16 DIN Straight Plug EZ-600-716M-X 3190-2643 <1.30:1 (6) Hex Spring Finger Crimp A/S 1.6 (42) 1.38 (35.0) 0.209 (94.80 4.7-16 DIN Straight Plug TC-600-716M-X 3190-2642 <1.30:1 (6) Hex Solder Crimp A/S 1.6 (40) 1.38 (35.0) 0.191 (86.6 5.7-16 DIN Straight Plug TC-600-716MC 3190-502 <1.25:1 (2.5) Hex Solder Clamp S/S 2.0 (51) 1.30 (33.0)0.347 (157.4) 6.7/16 Male Right Angle EZ-600-716M-RA-X 3190-2546 <1.35:1 (6) Hex Spring Finger Crimp NG 1.6 (40) 1.38 (35.0) 0.462(210.0) 7.7-16 DIN Right Angle TC-600-716M-RA-D 3190-2599 <1.35:1 (6) Hex Solder Crimp A/S 1.7 (44) 2.00 (50.9) 0.362(164.2) 8.7-16 DIN Straight Jack EZ-600-716F 3190-2447 <1.25:1 (6) Hex Spring Finger Crimp NG 1.8 (45) 1.32 (33.6) 0.158 (71.7) 9.HN Male Straight Plug TC-600-HNMC 3190-1429 <1.25:1 (<1) Knurl Solder Clamp S/g 2.3 (59.2) 0.88 (22.4) 0.25 (113) 10.LC Male Straight Plug TC-600-LCM 3190-1406 <1.25:1 (<1) Hex Solder Clamp N/S 3.1 (78.0) 1.62 (41.1) 1.20 (544) 11.N Female Straight Jack TC-600-NF-X 3190-2816 <1.30:1 (6) NA Solder Crimp NG 1.7 (43) 0.69 (17.6) 0.076 (34.6) 12.N Female Straight Jack EZ-600-NF-X 3190-2817 <1.30:1 (6) NA Spring Finger Crimp NG 1.7 (43) 0.69 (17.6) 0.090 (40.6) 13.N Female Bulkhead Jack EZ-600-NF-BH 3190-616 <1.25:1 (2.5) NA Spring Finger Crimp S/G 2.4 (61) 0.88 (22.4) 0.195 (88.5) 14.N Female Bulkhead Jack TC-600-NF-BH 3190-589 <1.25:1 (2.5) NA Solder Crimp S/G 2.4 (61) 0.88 (22.4) 0.195 (88.5) 15.N Female Bulkhead Jack TC-600-NFC-BH 3190-466 <1.25:1 (2.5) NA Solder Clamp S/G 2.2 (56) 0.94 (23.9) 0.214 (97.1) 16.N Male Straight Plug EZ-600-NMK 3190-669 <1.25:1 (2.5) Knurl Spring Finger Crimp S/G 2.1 (53) 0.92 (23.4) 0.164 (74.4) 17.N Male Straight Plug EZ-600-NMC-2-D 3190-2641 <1.25:1 (6) Hex/Knurl Spring Finger Clamp NG 2.1 (53) 0.92 (23.4) 0.202 (91.6) 18.N Male Straight Plug TC-600-NMC 3190-357 <1.25:1 (2.5) Hex Solder Clamp S/G 2.1 (53) 0.92 (23.4) 0.208 (93.4) 19.N Male Straight Plug EZ-600-NMH-X 3190-2627 <1.25:1 (8) Hex/Knurl Spring Finger Crimp NG 2.1 (53) 0.92 (23.4) 0.164 (74.4) 20.N Male Straight Plug TC-600-NMH-X 3190-2628 <1.25:1 (8) Hex/Knurl Spring Finger Crimp NG 2.1 (53) 0.92 (23.4) 0.166 (75.3) 21.N Male Right Angle EZ-600-NMH-RA-X 3190-2639 <1.35:1 (6) Hex Spring Finger Crimp NG 2.0 (50) 1.42 (36.0) 0.224(101.7) 22.N Male Right Angle TC-600-NMH-RA-D 3190-2427 <1.35:1 (6) Hex Solder Crimp NG 1.8 (46.5) 1.62 (41.2) 0.185 (84.3) 23.N Male Straight Plug TC-600-NMH-75-50 3190-1610 <1.35:1 (6) Hex Solder Crimp N/G 2.1 (52.8) 0.91 (23.1) 0.130 (59.0) 24.QDS Male Straight Plug TC-600-QDSM 3190-825 <1.25:1 (<1) Knurl Solder Clamp NG 2.2 (55.6) 1.00 (25.4) 0.25 (113) 25.TNC Male Straight Plug TC-600-TM-X 3190-2530 <1.25:1 (6) Hex/Knurl Solder Crimp NG 2.3 (57.6) 0.75 (19.0) 0.100 (45.6) 26.TNC Male Straight Plug EZ-600-TM-X 3190-2531 <1.25:1 (6) Hex/Knurl Spring Finger Crimp NG 2.3 (57.6 0.75 (19.0) 0.100 (45.6) 27.TNC Male Reverse Polarity EZ-600-TM-RP 3190-796 <1.25:1 (2.5) Knurl Spring Finger Crimp NG 2.2 (56) 0.87 (22.0) 0.112 (50.8) 28.TNC Male Reverse Polarity TC-600-TM-RP 3190-1064 <1.25:1 (6) Knurl Solder Crimp N/G 2.1 (53.3) 0.68 (17.3) 0.112 (50.8) 29.TNC Male Right Angle TC-600-TM-RA-D 3190-2707 <1.35:1 (6) Hex/Knurl Solder Crimp NG 1.6 (41) 1.75 (44.5) 0.164 (74.3) 30.TNC Female Reverse Polarity EZ-600-TF-RP 3190-797 <1.25:1 (2.5) NA Spring Finger Crimp NG 2.3 (58) 0.87 (22.0) 0.100 (45.4) 31.TNC Reverse Polarity TC-600-TF-RP 3190-1065 <1.35:1 (6) Knurl Solder Crimp N/G 2.2 (55.8) 0.68 (17.3) 0.100 (45.4) 32.UHF Male Straight Plug EZ-600-UM 3190-615 <1.25:1 (2.5) Knurl Spring Finger Crimp S/G 1.7 (43) 0.88 (22.4) 0.164 (74.4) 33.UHF Male Straight Plug TC-600-UMC 3190-213 <1.25:1 (2.5) Knurl Solder Clamp S/G 1.7 (43) 0.88 (22.4) 0.198 (89.8) Finsh metals:N=Nickel,S=Silver,G=Gold,SS=Stainless Steel,A=Alballoy **VSWR spec based on 3 foot cable with a connector pair "Available in bulk pack 30 (800) TMS-COAX • www.timesmicrowave.com 24 EZ-600-NMH-RA-X 25 TC-600-NMH-RA-D 26 3190-2639 '-+- 3190-2427 TTI MS Es MICROWAVE SYSTEMS r • 4- - 4.-- TC-600-NMH-75-50 -+..,,.-, 3190-1610 27 28129 110 VII* 30 31 32 . morC-600-TM-X 3190-2530 _ E TC-600-QDSM EZ-600-TM-X EZ-600-TM-RP TC-692 -D EZ-600-TF-RP 3190-825 3190-2531 3190-796 3190- 707 3190-797 33 HX-4 - EZ-600-UM 3190-200 _ 3190-615 34 Mb GST-600A CCT-01 11 r 3190-1051 3190-1544 • 11644Q..1 CST-600-3192-052 �* TC-600-UMC Y1720 ' 3190-213 CR-600to 3190-203 • ' 3190-831 RB- 56 — 3190-421 Y WR-600 3190-11435 � t Install Tools 319-01 3192-086 - ..... iii TK-600E 2 -3 90 60 , Part Stock Type Number Code Description Crimp Tool HX-4 3190-200 Crimp Handle Crimp Dies Y1720 3190-203 .610" Hex Dies Crimp Rings CR-600 3190-831 Crimp Rings for TC/EZ-600 connectors(pkg of 10) Strip Tool CST-600 3192-052 Combination prep tool for LMR-600 crimp and clamp style connectors Replacement Blades RB-456 3190-421 Replacement Blades for Strip Tools Deburr Tool DBT-U 3192-001 Removes center conductor rough edges Midspan Strip Tool GST-600A 3190-1051 For ground strap attachment Wrench WR-600 3190-1435 15/16" Box Wrench(2 required for EZ-600-NMC-2) Cutting Tool CCT-01 3190-1544 Cable end flush cut tool Replacement Blade RB-01 3190-1609 Replacement blade for cutting tool Replacement Blade Kit RB-CST 3192-086 Replacement blade kit for all CST strip tools Tool Kit TK-600EZ 3190-1602 Tool kit for LMR crimp/clamp connectors (includes CCT-01,CST-600, HX-4,Y1720,Tool Pouch) Wit i III -.17:1;‘-......--N 1`y x CS-A600T, ' #+' CS-60120T,CS-60170T 04111 i ril HG-600T SH-U600T CB-600T SC-600T Hardware - , -. Accessories Hanger Support Hardware - GK-S600TT Part Stock Type Number Code Description Ground Kit GK-S600TT GK-S600TT Standard Grounding Kit(each) Hoisting Grip HG-600T HG-600T Split/Laced Type(each) Cold Shrink CS-A600T CS-A600T Cable to Antenna Junction (each) Cold Shrink CS-60120T CS-60120T LMR-600 to-1200 Junction (each) Cold Shrink CS-60170T CS-60170T LMR-600 to-1700 Junction (each) Hanger Blocks CB-600T CB-600T Dual Cable Support Block(kit of 10) Standard Entry Port Cushion SC-600T-3 SC-600T-3 Three cables(each) Snap-In Hangers SH-U600T SH-U600T Snap-In Hangers(Kit of 10) Hanger Block Supporting Hardware Complete Range of Supporting Hardware&Adapters Available (800) TMS-COAX • www.timesmicrowave.com 31 nal tit\ /111\11/V, 4. ` 14Pe /onCC,41/9/ea/ ODIV1111 41,1 Signal Inside coaxial directional couplers feature low PIM, low insertion loss and ,, I power handling capability of 200 Watts* average power. Available with 7/16 DIN or N connectors • • *300 Watts with 7/16 DIN connector Specifications Passive Intermodulation(PIM) <_-150 dBc PIM Test Method 2 tones at+43dBm Impedance 50 Ohm VSWR < 1.20:1 Operating Temperature Range -30°C to+75°C Regulatory Compliance/Certifications RoHS/IP65 Application Indoor/Outdoor Part Number DC-3-N DC-4.8-N DC-6-N DC-8-N DC-10-N I DC-13-N DC-15-N Operating Frequency Band 698-2700 MHz Interface N Female Coupling 3dB 4.8dB 6dB 8dB 10dB 13dB 15dB Split Ratio 2:1 3:1 4:1 6:1 10:1 20:1 30:1 Coupliing Tolerance ±0.6dB ±0.8dB ±0.8dB ±0.8dB ±1.0dB ±1.0dB ±1.0dB Coupling Loss <_3.OdB <_2.OdB <_1.26 dB <_1.1dB x0.45 dB <_0.5dB <_0.4dB Insertion Loss <.25 dB <.25 dB <.25 dB <.20 dB <.20 dB <.20 dB <.20 dB Average Power 200W Peak Power 1.5 kW Part Number DC-3-D DC-4.8-D I DC-6-D DC-8-D DC-10-D DC-13-D I DC-15-D Operating Frequency Band 698-2700 MHz Interface 7/16 DIN Female Coupling 3dB 4.8dB 6dB 8dB 10dB 13dB 15dB Split Ratio 2:1 3:1 4:1 6:1 10:1 20:1 30:1 Coupliing Tolerance ±0.6dB ±0.8dB ±0.8dB ±0.8dB ±1.0dB ±1.0dB ±1.0dB Coupling Loss <_3.OdB <2.OdB <1.26 dB <1.1 dB <_0.45 dB <_0.5dB <_0.4dB Insertion Loss <.25 dB <.25 dB <.25 dB <.20 dB <.20 dB <.20 dB <.20 dB Average Power 300W Peak Power 1.5 kW www.signalinside.com IV ('\i'\J'S\ P '& et 6pfláet 5 ‘6 * r)7 /ode *4 iri s, 3 and y eexy 8/oc.* /e, IQeace✓e 3MdeA5 Signal Inside reactive power splitters are offered with N or 7/16 DIN connectors and are capable of handling high power, up to g_ 4 500 Watts. These units are ideal for either in-building or exterior applications where low Insertion loss and low PIM is important. Operating Frequency Band 698-2700 Impedance 50 ohms - Covers Cellular, UMTS and WiFi bands Power Rating (avg) 300 W - Low PIM Power Rating (max) 3 kW - IP65 Intermod (PIM)* <-150 dBc (2 tones at+43 dBm) - Low Insertion Loss Operating Temperature -25°C to +85°C - Up to 500W Average Power Environmental IP65 Mounting Bracket Built-in - Cost Effective rMIMI { .rte --r II Amplitude Model Model No. of Insertion Input Split Loss Balance, ways Loss VSWR 7/16 DIN N typ. PS-2-D PS-2-N 2 3 dB <0.1 dB 0.2 dB <1.2:1 PS-3-D PS-3-N 3 4.8 dB <0.1 dB 0.2 dB <1.25:1 PS-4-D PS-4-N 4 6 dB <0.2 dB 0.3 dB <1.3:1 www.signalinside.com tiii ri I IN /1 11'11/44111/V, •or 11 lilli 749/Vet-5 61:9,4/ Samar /eiNs gonai j..,07,51 de Ili ir Ar Typically used in Distributed Antenna Systems (DAS), 11 4. _L-,2,.-t. ail. Tappers, also known as signal samplers, operate similar to a directional coupler, but without the directivity.These are available with N female connectors viii jaw Specifications Passive Intermodulation(PIM) <_-150 dBc PIM Test Method 2 tones at+43dBm Impedance 50 Ohm Dissapative Loss 0.1 dB max.(main line) Operating Temperature Range -30°C to+75°C Regulatory RoHS/IP65 Compliance/Certifications Application Indoor/Outdoor Part Number PT-3-N PT-4.8-N PT-6-N PT 8-N PT-10-N PT-13-N PT 15-N PT-20-N PT-30-N Operating Frequency Band 698-2700 MHz Interface N Female Coupling 3dB 4.8dB 6dB 8dB 10dB 13dB 15dB 20 dB 30 dB Split Ratio 2:1 3:1 4:1 6:1 10:1 20:1 30:1 100:1 1000:1 Outputs ref.to Input level,incl. Loss,dB Main/Branch -1.8/-4.8 -1.3/-6.1 -1.0/-7.0 -0.7/-8.6 -0.4/-10.4 -0.2/-13.2 -0.1/-15.1 -0.1/-20.1 -0.1/-30.1 Branch Flatness -0.5/-0.8 +/-0.7 +/-0.7 +/-0.8 +/-1.0 +/-1.0 +/-1.25 +/-1.0 +2.0/-0.5 - Average Power 500W Peak Power 3 kW Part Number PT-3-D PT 4.8-D PT-6-D PT-8-D PT-10-D PT-13-D PT-15-D PT-20-D PT 30-D Operating Frequency Band 698-2700 MHz Interface 7/16 DIN Female Coupling3dB I 4.8dB 6dB 8dB 10dB 13dB I 15dB 20 dB 30 dB Split Ratio 2:1 L 3:1 4:1 6:1 10:1 20:1 IL 30:1 100:1 1000:1 Outputs ref.to Input level,incl. - Loss,dB Main/Branch -1.8/-4.8 -1.3/-6.1 -1.0/-7.0 -0.7/-8.6 -0.4/-10.4 -0.2/-13.2 -0.1/-15.1 -0.1/-20.1 -0.1/-30.1 Branch Flatness -0.5/-0.8 +/-0.7 +/-0.7 +/-0.8 +/-1.0 +/-1.0 +/-1.25 +/-1.0 +2.0/-0.5 Average Power 500W I Peak Power 3 kW www.signalinside.com Detailed Specifications & Technical Data BEL KIN ENGLISH MEASUREMENT VERSION wawo Ixexro►rtsawus 84142 Coax - 50 Ohm Coax For more Information .n. please call 1-800-Belden1 ,M44� Description: 19 AWG solid .037" silver-coated copper-covered steel conductor, plenum, TFE Teflon®insulation, double silver-coated copper braid shields (95% coverage), FEP jacket. Physical Characteristics (Overall) Conductor AWG: # 1 19 Solid SCCCS-Silver-coated Copper-covered Steel 0.037 Total Number of Conductors: 1 Insulation Insulation Material: Teflon® TFE-Tetrafluoroethylene .116 Outer Shield Outer Shield Material: 7711uter Shield ._Silver-coated Copper 95.000 Silver-coated Copper 95.000 Outer Jacket Outer Jacket Material: FEP-Fluorinated Ethylene Propylene Overall Cable Overall Nominal Diameter: 0.195 in. Mechanical Characteristics (Overall) Operating Temperature Range: -70°C To+200°C UL Temperature Rating: 200°C Bulk Cable Weight: 43 lbs/1000 ft. Max.Recommended Pulling Tension: 146 lbs. Min.Bend Radius/Minor Axis: 2 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards&Environmental Programs NEC/(UL)Specification: CMP CEC/C(UL)Specification: CMP EU CE Mark: No EU Directive 2000/53/EC(ELV): Yes EU Directive 2002/95/EC(RoHS): Yes EU RoHS Compliance Date(mm/dd/yyyy): 04/01/2005 Page 1 of 3 09-04-2012 Detailed Specifications & Technical Data BEL KEN ENGLISH MEASUREMENT VERSION wawo Ixexro►rtsawus 84142 Coax - 50 Ohm Coax EU Directive 2002/96/EC(WEEE): Yes EU Directive 2003/11/EC(BFR): Yes CA Prop 65(CJ for Wire&Cable): Yes MII Order#39(China RoHS): Yes Military Specification: MIL-DTL-17H,M17/60 RG Type: 142/U Flame Test C(UL)Flame Test: FT6 Plenum/Non-Plenum Plenum(Y/N): Yes Electrical Characteristics (Overall) Nom.Characteristic Impedance: 50 Nom.Inductance: .067 Nom.Capacitance Conductor to Shield: 29.0 29.0 Nominal Velocity of Propagation: 70% Nominal Delay: 1.Delay(ns/ft) 1.48 Nom.Conductor DC Resistance: 19.3 Nominal Outer Shield DC Resistance: ppm_ CR @ 20°C(Ohm/1000 ft) 2.3 Maximum VSWR: z) 50 '1.11 400 1.14 1000 1.17 3000 1.33 8000 1.33 Nom.Attenuation: Freq.(MHz)Attenuation(d 10 1.1 50 2.6 100 3.8 200 5.4 400 7.9 700 10.7 900 12.3 1000 13.1 2000 19.3 3000 24.2 5000 32.6 ISO 9001 Certified TM Times Protect LP-BTR Series - f f % • DC Blocked for Maximum _ / I Surge Protection l 'V I • Multi-Strike Capability 411, ....of i. • Broadband Performance from 20MHz i up to 1000MHz . • Exceptional RF Characteristics :_� r • Solid Brass Construction for ` \It _4 Durability and Long Life • Universal Grounding Bracket for Flange or Bulkhead Installations Lightning and Surge Protection for The 21st Century TM '14-1e:17 The Times ProtectTM LP-BTR high performance surge arrestor ------ series addresses applications in the 20MHz-1000MHz spectrum. Our unique DC blocking technology employed in this design pro- vides optimum isolation of the antenna port from the protected equipment port for maximum surge protection. LP-BTR surge I protectors have exceptional RF performance and are constructed from the highest quality materials for unsurpassed durability and i J— longevity. These units meet and surpass all applicable industry standards. The LP-BTR product family is available with N connector _Ill configurations to satisfy various installation requirements. LP-BTR Series: • • LP-BTR-NFF N Female connectors on surge and protected sides • LP-BTR-NMP N Male connector on protected side with N Female connector on surge side • LP-BTR-NMS N Male connector on surge side with N Female connector on protected side TIMES rMICROWAVE SYSTEMS Times-ProtectT M � f S eci ications UM _ _ __ma__ ---lv—1 Electrical Specifications • � . ® 1 Impedance 50 0 I1�!� 1 • fII o Frequency Range 20-1000 MHz Ai O VSWR/Return Loss <1.1:1 /<-26dB 0411 Pi1E:) ,05319k1M1rI "'°"a"" - >, `' Insertion Loss <0.1dB 0 a ' ` ' Impulse Discharge Current 10KA multiple (8x2Ops wave-form) • LP-BTR-NFF Turn-on Voltage 600V±20% 20-1000MHz DC Blocked N Type F/F Turn-on Time 2.5ns for 2kV/ns Energy Throughput Rating <200pJ(4kV/2kA1.2x50/8x2Opswave-form) Qv .,I Power Handling at Frequency 375W (20-220MHz) 125W (220-700MHz) , ," 411 p 50W (700-1000MHz) 1"111111 ,. 0 Protection Circuit DC Blocked °.w'�t.^� ' T,, Mechanical / Environmental Specifications ,,.,_,..,„„0 ` . Temp Range Storage/Operating -40°C-+85°C/-40°C-+50°C • LP-BTR-NMP Weatherization Required for external use 20-1000MHz DC Blocked N Type M on Protected Thermal Shock US MIL STD 202, Meth.107,Cond.B Vibration US MIL-STD 202, Meth.204,Cond.B Shock US MIL-STD 202, Meth.213,Cond.l 7.116 RoHS Compliant Yes -- Mating Life Cycle > 500 NINNMMd Recommended1111.1Coupling Nut Torque 7 to 10 lb-in of*Iil0IIpI � nA Material Specifications ,P.., . ' • Component Material Plating 0 Body Brass White Bronze •LP-BTR-NMS Inner Conductor Male Brass Silver 20-1000MHz DC Blocked N Type M on Surge Inner Conductor Female Phosphor Bronze Silver _ Outer Conductor Brass White Bronze _ All dimensions shown in inches Coupling Nut Brass White Bronze Insulator PTFE -- s11 TYPICAL RETURN LOSS(dB) S21 TYPICAL INSERTION LOSS SdB) -5.0 0.03 - -10.0 - 0-o --- - •15.0 I • .. — _ 0.01 - _ _. -20.0 — — - 0.000 . .. -- - -- -25.0 — -- •0.01 •aa.n •-0.oa �9 - t •i . ► a -40.0 P. • .0 _ a -0.05 - . -50.0 006 —.. . 55.0 - ------ — .— .. 4107 .— I .. .... _ 0.09 0 - -- - -- - - .sss..75•DStart Mit WSW 70kHz Stop 1200MHz •00.1 •7.o- ss , Start 20MHz IFOW 70701-1zSlop OOOMHz i 7rTIMES MICROWAVE SYSTEMS World Headquarters:358 Hall Avenue,Wallingford,CT 06492•Tel:203-949-8400,1-800-867-2629•Fax:203-949-8423 International Sales:4 School Brae,Dysart,Kirkcaldy,Fife,Scotland KY1 2XB UK•Tel:+44(0)1592655428 China Sales:No.318 Yuan Shan Road,Shanghai 201108 China•Tel:86-21-51761234•Fax:86-21-64424098 www.timesmicrowave.com ©2010,Times Microwave Systems,Wallingford,CT 06492 LP-BTR-2 9/10 MCR 806/900 BROADBAND CORNER REFLECTOR WHERE TO MOUNT THE ANTENNA MECHANICAL SPECIFICATIONS The MCR806 and MCR900 corner reflectors may be Part Number MCR806 MCR900 mounted on any mast of 1-1/4" in diameter. Rated Wind Velocity 100 mph Lateral Thrust 111 lbs. MOUNTING INSTRUCTIONS Equivalent Flat Plate Area 1.90 ft' 1. The corner reflector antenna is completely as- Height 14 inches sembled at the factory. Weight 4.4 lbs. 2. Slide a U-bolt over the mast and through one set of Material Heavy aluminum holes in the antenna. Repeatthe same forthe other U-bolt and the mounting holes. Mounting 2 U-bolts furnished to mount on vertical masts of up to 1-1/4"O.D. 3. Attach the cable from the antenna to the feed line from the transmitter and cover the connection with Shipping Information Weight:5 lbs. the connector boot. Secure the cables to the mast Dimensions: 16 1/2"x 16-1/2"x 16-1/2" to eliminate strain along the cable route. ELECTRICAL SPECIFICATIONS Part Number MCR806 MCR900 Power(watts) 100 Max. Gain(forward) 8.5 dB Min. Front-to-Back Ratio 23 dB Min. Frequency(MHz) 806-896 896-970 41F Bandwidth(MHz) 64 VSWR Less than 1.5:1 • Impedence (Ohms) 50 Nominal • Vertical Beamwidth 56° Horizontal Beamwidth 45° Termination RG213/U with"N"connector(supplied) CAUTION AND WARNING! YOU COULD BE KILLED IF THIS ANTENNA COMES IN CONTACT WITH ELECTRIC POWER LINES OR IS BROUGHT IN PROXIMITY WITH A HIGH VOLTAGE FIELD. FOR YOUR OWN SAFETY USE EXTREME CAUTION WHEN INSTALLING THIS ANTENNA. KEEP AWAY FROM POWER LINES. Building Wireless Solutions° )0, 746-896 MHz Yagi Antenna (11 dBi) Specifications r I i T ++4 Gain 11 dBi VSWR <1.7:1 Model Number Horizontal Beamwidth 48° • CSI-AY/746-896/11 Vertical Beamwidth 42° Polarization Vertical Frequency Range Maximum Input Power 100 Watts Electrical Downtilt 0° • 746-896 MHz Front-back Ratio >16 dB Connector N-Female Features & Benefits Lightning Protection Direct Ground • 11 dBi Gain Rated Wind Speed 134 mph (200 kph) • 8 Elements Dimensions 33.1 x 8 x 2.2 in Antenna Weight 1.76 lbs • Hermetically Sealed Driven Element Mounting Hardware U-Bolt • Rugged Lightweight Design Included Mounting Hardward Fits 1 7/8"OD Pipe • Stainless Steel Hardware • Broad Bandwidth Specifications subject to change without notice. Radiation Patterns .) Vertical Horizontal ( f)CSI cellular specialties. 1.877.844.4C51(4274) ©2012 CELLULAR SPECIALTIES INC. www.cellularspecialties.com ECO 2805 021-0047-001 REV D 14 NOV 2012 ROOF MOUNTS - FRM RM FRM NON - PENETRATING The FRM mount is a lightweight mount and is galvanized for corrosion protection.The FRM mount is easily shipped via UPS. Order(1)optional FRMMAT(1/8"thick)or(1)optional FRMPAD(3/8"thick)for a protective barrier between the mount and the roof. Order(1)optional SCK150 • safety cable kit(3/16"x 150'). 1.25"to 2.38"Mast Tube Diameters 2.5'and 5'Overall v , Mast Heights 1NSeescriptions) A ,4) 16"Nominal Blocks O OO . 4 3'Square FRM BA LLA ST REQUIREMENTS Effective Zero Vmax at centroid of projected area,(MPH) Projected Ballast Velocity Vs MAST SPECIFICATIONS Area(EPA) (LBS) Load (MPH) (FT2) (PSF) h=2 FT h=3 FT h=4 FT h=5 FT Mount Mast Mast Description&Height 100 12 140 135 110 96 85 Part No. Part No. 2 200 24 198 188 153 133 119 FRM125 FY202 1.25"O.D.x 16GA.x5.0'(PG) 300 36 242 222 182 157(154) 141 (131) 400 48 280 269 219(197) 190(154) 170(131) FRM150 FY203 1.50"O.D.x16GA.x2.5'(PG) 100 12 99 96 78 68 60 FRM 166 FY204 1.66"O.D.x 16 GA.x 2.5'(PG) 4 200 24 140 133 108 94 84 300 36 171 157 129 111 99(93) 400 48 198 190 155 039) 134009) 120(93) FRM238 FY205 2.38"O.D.x 0.154"wall x 2.5'(HDG) 100 12 81 78 64 55 49 FRM225 FY205SP 2.25"O.D.x 14 GA.x 5.0'(HDG) 6 200 24 114 108 88 77 68 300 36 140 128 105 91 (89) 81 (76) FRM2385P5 FY253 2.38"O.D.x 0.154"wall x 5.0'(HDG) 400 48 161 155 127(114) 110(89) 98(76) PG=Pre-galvanized mast h=Distance from support surface to centroid of EPA. HDG=Hot-dip galvanized mast Vs=Effective wind velocity resulting in sliding on a flat surface with a.50 coefficient of friction. Vmax=Effective wind velocity based on strength or overturning. NOTE:The velocities in( )apply to the FRM125 mount when the strength of the FRM125 mast governs. MIK co Phone (309) 566-3000 • Fax(309) 566-3079 • o w Ho P oo ets.com • The Industry Standard Products LLC ). I I e I 1 a MM2410C MM2410G tp--, 1 • 1 II I t I I 4 III • 1M144OC 1 I MM/440G 5ji1 , ® ® 011:11 ® ® ® ® ® ® ®® ® ® ® ® ® ® ® ® CONFIGURATIONS Multiple combinations of duplex,GFCI,switch,and rounds:1 1/4'11 3/8,1 9/1611 5/8'11 11/16'12 1/£V12 1/4'12 7/16 TAYMAC ITEM# UPC NUMBER DESCRIPTION DEPTH COLOR SHELF PACK SHELF PACK WEIGHT(LBS) 2-Gans In-Use Covers _ MM2410C 0-92326-10406-7 55-in-1 Standard 2.75" Clear 6 3.95 MM2410G 0-92326-10405-0 55-in-1 Standard 2.75" Gray 6 3.95 MM7440C 0-92326-10408-1 55-in-1 Jumbo 4.75" Clear 3 2.70 MM7440G 0-92326-10407-4 55-in-1 Jumbo 4.75" Gray 3 2.70 www.taymac.com 4 TayMac