Loading...
HomeMy WebLinkAboutA16-0008_FA000_1455748740.pdf tatitli OF p... till. 1111 ,1111 '11. Z ec _LEGE\ D : SYMBOL DEVICE MANUFACTURER/PART# MOUNTING `�,r., ��r��. � # r• LS� r FACP Honeywell Vista-1286PT �� +��lG/y Yr .15.,1% �:. 2/1716&Emergency Services Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox © �, .0e... .4 352331 645 FOREST ROAD KP i...,_j0., i,i, ': Ademco Vista 128 FACP LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox ', •. - •,�w;• Standby �•` S/Otktl4L ,r'" Number of Current Total Current Combination Smoke & •*•...... Device Type Devices (Amps) (Amps) Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box Main FACP CPU 1 x 0.032 = 0.032 4193SN Serial Interface 1 X 0.00015 = 0.00015 Combination Smoke and COSMOD4W Module 3 X 0.052 = 0.156 Oco CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box i3 Smoke Detector 5 X 0.0005 = 0.0025 i4 Smoke/CO Detector 9 X 0.0005 = 0.0045 O System Sensor 5601 P 6160 Keypad 1 X 0.04 = 0.04 Heat Detector w/4193SN Addressable module 4" square box SUM COLUMN FOR STANDBY LOAD 0.23515 = AMPS Alarm Load ElCosmo Interface Module COSMOD4W Number of Current Total Current Device Type Devices (Amps) (Amps) IKBI Knox Box Main FACP CPU 1 X 0.032 = 0.032 4193SN Serial Interface 1 X 0.00015 = 0.00015 COSMOD4W Module 3 X 0.075 = 0.225 ,0, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox i3 Smoke Detector 5 X 0.035 = 0.175 i4 Smoke/CO Detector 9 X. 0.04 = ' 0.36 6160 Keypad 1 X 0.1 = 0.1 Outside Horn/Strobe 1 X 0.195 = 0.195 SUM COLUMN FOR ALARM LOAD 1.08715 = AMPS GENERAL NOTES: o Standby Load Required Standby Time in Hours rL Current (Amps) 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN 0 0.23515 X 24 = 5.64 ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE w 0 Alarm Load Required Alarm Time in Hours DEPARTMENT REQUIREMENTS AND NFPA 72. z Current (Amps) (15 MINUTES) 2. REFER TO MANUFACTURERS DATA SHEETS AND o 1.08715 X 0.25 = 027 5 INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION Add Standby and Alarm Load for Required cc Ampere Hour Battery 5.92 REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Multiply by the Derating Factor of 1.2 PROGRAMMING AND DEVICE OPERATION. . Total Ampere Hours Required = 7.10 Batteries Provided: 12AH Minimum Approved as noted. Field locate devices if w 1- needed per conditions at rough in. Post a permit and plans on job site. d Z N tO 07 0 SEQUE\CE OF Z Q o (J) o 0 R OJ MOPEATIONS: N Q Z } ZzZZ '- 6 ° OD VO i C LO J z LO CO w (nQ (nQ wQ Ozw •....... Oo D LL Q O D c w D z w .1"..... >, Q o E _ = o a_ o 0 0 O 0 O c o y x coU Z1- < u) E I- ct (2 - m -45 x .._ 0 OOU Z O 70 _ _ O lll -2 DEVICE > > o zz -e z -e > zZ >z � +� DESCRIPTION Q Q Q - t a a i 1- o F- o I- 1- Q O Q O (� Q o„ O o h. SMOKE DETECTOR X X X r IMP�� �qIB ip CD z HEAT DETECTOR X X X E O z 0 CARBON MONOXIDE DETECTOR X X Co SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X OO CO CO 1- 0) PROJECT I \ FOVATO \ : rn 645 FOREST COAD o VAIL COLORADO rn w 0 FRE ALARIV SYSTEM D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) 0 i X = 2-WIRE DATA, 2-#16AWG EOL EOL AHJ: VAIL FIRE 8c EMERGENCY SERVICES z W 2 APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 O z N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG i Q Z = 2-WIRE DATA CIRCUIT, 2-#16AWG D D FULLY SPRINKLERED F- KP = KEYPAD CIRCUITING, 4-#18AWG FIRE ALARM SYSTEM FOR DUPLEX UNIT. SYSTEM INCLUDES NEW 0 = RISER NOTES: co 2 ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE J Q DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE W 1 1 . REFER TO VISTA INSTALLATION MANUAL FOR D ( CO OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE J 0 MORE INFORMATION. 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS L,N L,N PROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. HEAT DETECTORS D CO 0 W MANUFACTURERS SPECIFICATIONS. c �� WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO < 0 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W MP) (TYP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE PRIOR TO INSTALLATION. WIRING DIAGRAM IS O <HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM O 0 INCLUDED SUBMITTAL BOOKS. SYSTEM. 0 CO 120VAC DEDICATED POWER VISTA 128FPB Z (/) O H Q CONTROL PANEL - FLOW SWITCH W J 0W Z TAMPER SWITCH O z TELEPHONE LINE - FIRE TELEPHONE LINE - SECURITY BELL N WP FIRE PROTECTION ENGINEER: O 0 I- O OUTPUT CO, EOLR DEBORAH SHANER, P.E., SHANER LIFE SAFETY Lc) J Z LLJ CO 80443 ' Q 0 W DATA/COM KP I I PO BOX 1073, FRISCO, 0 0 ISE IAG �A V OUTPUT KEYPAD KEYPAD PHONE: 970-409-9082 FAX: 970-797- 1898 SHEET DESCRIPTION: FIRE ALARM PLAN DRAWN BY: DATE: DLS 1/25/16 SHEET#: FA-0.00