HomeMy WebLinkAboutA16-0009_FA000_1455748680.pdf z 3• + RL■.. 1d' g " Vail Fire&Emergency Services LEGE\ 9 : 'o , ;r- gym. o2„7„s SYMBOL DEVICE MANUFACTURER/PART# MOUNTING 7 7%-..-A.'-e,u5233 FACP Honeywell Vista-128BPT ;: ;:' Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox -...:(e, ��Q tl4L 4;•+F 655 FOREST ROAD ` .........-.0' Ademc❑ Vista 128 FACP KP Standby LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox Number of Current Total Current Device Type Devices (Amps) (Amps) Combination Smoke & Main FACP CPU 1 X 0.032 = 0.032 0 Heat Detector w/Sounder System Sensor i3 series 4WTA—B 4” square box 4193SN Serial Interface 1 X 0.00015 = 0.00015 COSMOD4W Module 3 X 0.052 = 0.156 Combination Smoke and 13 Smoke Detector 3 X 0.0005 = 0.0015 ®co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box i4 Smoke/CO Detector 6 X 0.0005 = 0.003 ' 6160 Keypad 1 X 0.04 = 0.04 O System Sensor 5601 P SUM COLUMN FOR STANDBY LOAD 0.23265 = AMPS Heat Detector w/4193SN Addressable module 4" square box Alarm Load C❑ Cosmo Interface Module COSMOD4W Number of Current Total Current Device Type Devices (Amps) (Amps) Main FACP CPU 1 X 0.032 = 0.032 KB Knox Box 4193SN Serial Interface 1 X 0.00015 = 0.00015 COSMOD4W Module 3 X 0.075 = 0.225 3 Smoke Detector 3 X 0.035 - 0.105 ,0, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox Z i4 Smoke/CO Detector 6 X 0.04 = 0.24 0 6160 Keypad 1 X 0.1 = 0.1 a_ Outside Hom/Strobe 1 X 0.195 = 0.195 E SUM COLUMN FOR ALARM LOAD 0.89715 = AMPS w Standby Load Required Standby Time in Hours GENERAL NOTES: Z Current (Amps) 0 0.23265 X 24 = 5.58 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN Alam Load Required Alarm Time in Hours ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE cc Current (Amps) (15 MINUTES) DEPARTMENT REQUIREMENTS AND NFPA 72. 0.89715 X 0.25 = 0.22: 2. REFER TO MANUFACTURERS DATA SHEETS AND Add Standby and Alarm Load for Required INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION Ampere Hour Battery 5.81 Multiply by the Derating Factor of 1.2 REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Q Total Ampere Hours Required = 6.97 PROGRAMMING AND DEVICE OPERATION. 0 Batteries Provided: 12AH Minimum 0 z 0 N CO 07 0 0 Q CC C 0 _ C J 00 >0 = O O Ln SEQUENCE OF J W •— ° 0 OPERATIO\S: Q Q (n J Z 01 .r U vi W Z 0 0 0 (n 0 Oz O `Mf' w co m (/) W W O WcOx c D cn C cn op (n u m M y WQ 0 5 a 0o gz Sz 22 m (nW � �' °' U Z I- Q f (1) CL I- CC Ct l- m CI rn LI AZO i- i- 1- 1- 1- � U Ow O o DEVICE Q h. Q -9 (cn0 � 0 � 0 Q0 ffi l— =' DESCRIPTION 1 1 ct a z z � D I X _ Q Q I- O I- 0 I- 0 0 Q 0 CD Z I z 1- SMOKE DETECTOR X X X o z 0 M ti HEAT DETECTOR X X X CARBON MONOXIDE DETECTOR X X X SPRINKLER WATERFLOW SWITCH X X X X 00 SPRINKLER TAMPER SWITCH X X M POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X 1- C) 0 PROJECT I \ FOVAT O \ : rn LU 655 FOREST ROAD co - VAIL COLOA3O v w FI E9 ALAS Vl SYSTE V 00 z D = 4—WIRE DATA/POWER, 4—#16AWG (2 PAIR) i _ — 2—WIRE DATA, 2—#16AWG EOL EOL AHJ: VAIL FIRE 8c EMERGENCY SERVICES I— X Cr) O O APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 0 N = 2—WIRE SOUNDER CIRCUIT, 2—#18AWG J Q Z = 2—WIRE DATA CIRCUIT, 2—#16AWG D D FULLY SPRINKLERED W 1 KP = KEYPAD CIRCUITING, 4—#18AWG FIRE ALARM SYSTEM FOR DUPLEX UNIT. SYSTEM INCLUDES NEW _I 0 RRISER NOTES: Co co ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE 0 = W DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE < 0 1- 0 1. REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE MORE INFORMATION. 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS PROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. HEAT DETECTORS CL < MANUFACTURERS SPECIFICATIONS. L,N LN n WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO i O 0 CO 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (n'P) (NP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE C!) 0 U 0 PRIOR TO INSTALLATION. WIRING DIAGRAM IS Z HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM W INCLUDED SUBMITTAL BOOKS. � SYSTEM. � 0 < Z 120VAC DEDICATED POWER VISTA 128FPB Z 0 U I— 0 CONTROL PANEL FLOW SWITCH U J = Z TAMPER SWITCH Q 0 UJ TELEPHONE LINE FIRE LO TELEPHONE LINE — SECURITY ;;WP FIRE PROTECTION ENGINEER: > U 0 BELL N �� EOLR OUTPUT DEBORAH SHANER, P.E., SHANER LIFE SAFETY SHEET DESCRIPTION: DATA/COM KP I I I PO BOX 1073, FRISCO, CO 80443 FIRE ALARM PLAN SES AGAV OUTPUT KEYPAD KEYPAD PHONE: 970-409-9082 FAX: 970-797- 1898 DRAWN BY: DATE: DLS 1/25/16 SHEET#: FA-0.00