A16-0010_5002- NX CUTS_1455817620.pdf
NetworX Control Panels Models NX-4, NX-6, NX-8 -_ • and NX-8E - • l OVERVIEW STANDARD FEATURES The NetworX line of control panels represent a full-featured •Flash memory microprocessor security system that uses advanced technology for burglary,fire •Expanded event log and environmental detection.A highly flexible security option that •Early open/late close reporting is both easy to install and simple to use,NetworX control panels •Programmable loop response can accommodate smaller residential applications up to the most •Accommodates multiple user codes from 8 up to 240 demanding commercial security needs.The series includes the •Up to 8 true partitions with separate account codes,entry/exit delays NX-4,NX-6,NX-8 and NX-8E control panels. and feature selections for each partition •Up to 512-event history log that provides date,time,event and Outstanding features user number Offering up to eight standard hardwire zone inputs,the control •Supports SIA and contact ID communication formats panels also provide four programmable outputs that can be set up •2-wire or 4-wire smoke detector compatibility to activate external devices during an alarm or other system event. •CP-01 2000 compliant The modular design allows for complete integration of multiple systems within one enclosure,and adding more zones or expanding In addition,NX-8E control panel also offers capability is fast and easy.With the addition of a Z-Wave®enabled •Fire alarm verification for greater false alarm immunity Cellular Module,with service from Alarm.com,control of automated •Dynamic battery test lights,door locks,thermostats and more is available using almost •Standard RS-232 on-board interface any Web enabled device. Convenient and flexible Users can conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface.Off-site programming is also available with DL-900 software for Windows. NX-4 Four hardwire zone inputs,expandable to 8 fully programmable hardwire and/or wireless zones NX-6 Six hardwire zone inputs,expandable to 12 fully programmable hardwire or 16 wireless zones NX-8 Eight hardwire zone inputs,expandable to 48 fully programmable hardwire and/or wireless zones NX-8E Eight hardwire zone inputs and two relays,expandable to 192 fully programmable hardwire and/or wireless zones interlogix.com NJ etwo rX North America Asia Australia EuropeLatin America T 855-286-8889 T 852-2907-8108 T 61-3-9239-1200 T 32-2-725-11-20 T 561-998-6114 Control Panels Models NX-4, NX-6, NX-8 and NX-8E Specifications Description NX-4 NX-6 NX-8 NX-8E Standard hardwire zones 4 6 8 8 Maximum hardwire zones 8 12 48 192 Maximum wireless zones 8 16 48 192 Partitions 1 2 8 8 Event log 185 512 User codes 8 40 99 240 Smoke loop 4-wire only 2-wire/4-wire Built-in siren driver 2 Tone(Steady&Yelp) Operating power 16.5VAC,40VA Auxiliary power 1 Amp 2 Amp Operating temperature 0°C to 49°C(32°F to 120°F) Dimensions(H x W x D) 8.3 x 9.3 x 3.5 in. 11.3 x 11.3 x 3.5 in. Regulatory UL365,609,985,1023,1610,1635,1637 CAN/ULC-S303-M91;S545-M89;ORD-C1023-1974 Ordering Information Accessories Four Hardwire Zone Inputs,Expandable 600-1023 Transformer, 16.5VAC,40VA NX-4 to 8 Fully Programmable Hardwire and/or NX-320E Smart Power Supply and Bus Extender Wireless Zones Six Hardwire Zone Inputs,Expandable NX-148E LCD Keypad NX-6 to 12 Fully Programmable Hardwire or NX-148E-RF LCD Keypad w/Integrated 48-Zone Wireless Receiver 16 Wireless Zones NX-548E 48-Zone Wireless Receiver Eight Hardwire Zone Inputs,Expandable NX-8 to 48 Fully Programmable Hardwire and/or NX-582E AES Long-Range Radio Interface Module Wireless Zones NX-584 Home Automation Interface Module with RS-232 Eight Hardwire Zone Inputs and Two Relays, NX-590NE TCP/IP Module NX-8E Expandable to 192 Fully Programmable Hardwire and/or Wireless Zones NX-591 NE-GSM 3G/4G GSM Module(Multi-Carrier) NX-592E-GSM-ZX-AT Alarm.com 3G/4G GSM Module w/Z-Wave®AT&T" NX-592E-GSM-ZX-TM Alarm.com 3G/4G GSM Module w/Z-Wave,T-Mobile® NX-592E-CDMA-ZX-VZ Alarm.com CDMA Module w/Z-Wave,Verizon®Wireless interlogix d interlogix.com Z-Wave®is a registered US trademark of Zensys A/S. Complies with FCC and Industry Canada regulations. Specifications subject to change without notice. ©2013 Interlogix. All rights reserved. Interlogix is part of UTC Climate,Controls&Security, a unit of United Technologies Corporation. 302-3631 2013/06 (73841) NetworX Wireless LCD DisplayKeypad71:1 OVERVIEW STANDARD FEATURES The NetworX wireless LCD display keypad is an integrated 48-zone •Integrated 48-zone wireless receiver wireless receiver LCD keypad with traditional design and an easy-to- •Optimize wireless reception by having the keypad/receiver read,customizable display. It is compatible with all NetworX in the best location control panels. •LCD,easy-to-read programmable display •Traditional design to go with any decor The NetworX wireless LCD display keypad offers the convenience •Compatible with all NetworX series control panels of having an integrated wireless receiver built into the keypad along •Easy to install,program and maintain with standard hardwire features.A removable door allows the user to swing the door down or simply take it off for use.The emergency Specifications keys are highlighted on the keypad and can be programmed to Electrical contact and send complete information to a responding police,fire Current 75mA maximum or EMS unit with just one touch.There are also five pre-programmed Wireless touch keys that allow the most common functions to be performed Frequency 319.5MHz with ease.All keys are backlit to ensure error-free operation —even Range 600ft.(183m)open air in a dark room. Environmental The NetworX wireless LCD display keypad is cost-effective and easy Operating temperature 32°F-120°F(0°C-49°C) to install.Designed for functionality and compatibility,it's the right Physical keypad to fit any application. Dimensions(HxWxD) 5.3 x 6.2 x 1.1 in.(135 x 157 x 27 mm) Construction ABS plastic Color White Ordering Information NX-148E-RF NetworX 48-Zone LCD Display Keypad w/Door and Integrated Wireless Receiver interlogix interlogix.com Specifications subject to change without notice. ©2014 United Technologies Corporation. North America All rights reserved. T 855-286-8889 Interlogix is part of UTC Building&Industrial Systems, Latin America a unit of United Technologies Corporation. T 561-998-6114 305-3662 2014/03 (74998) PinPoint . _ • • Addressable Point • ID Systems - ` ' ......m. :_ . OVERVIEW STANDARD FEATURES Bringing together the functionality of the NetworX NX-8E and the •Single two-wire loop up to two miles means fast and easy reliable performance of Interlogix sensors,the PinPoint addressable installation for new construction or retrofit applications Point ID solution is well suited for a variety of modern applications. •Addressable sensors indicate exact location of alarm event Supporting up to 192 devices on a single two-wire loop up to two •Supports up to 192 devices miles,this point ID solution easily installs in new construction or •Advanced digital communications from the sensors retrofit applications. to the panel •Supports 3 Class B loops Components for this system include the Network NX-8E, Pinpoint Interface Card,AP Series Motion Sensor,ShatterPro"Glassbreak Sensor and Input/Out devices. For use with the NX-2192E PinPoint ID bus interface AP750-ID Addressable PIR SI-ID Single Input Device - •Adaptive Signal Processing—3D signal •Supports a single, non addressable device processing with gliding focus mirror optics I • • Employs advanced digital data communication analyzes size,speed,shape and adaptive protocol that ensures the integrity of the alarm threshold data communication • Provides four separate curtain coverage patterns with 50' (15.2m)range • Flat wall or corner mounting height up to 10' (3m) 4140-ID Four Input Four Output Device •Supports four inputs and four unsupervised •Ships with two plastic inserts,each covering half outputs(horns, bells,sirens,etc.) the coverage area for more flexible mounting • Employs advanced digital data communication options(center curtain always active) protocol that ensures the integrity of the data 5845-ID Addressable ShatterPro® communication Glassbreak Sensor L •ShatterPro's Pattern Recognition Technology— NX-2192E Point ID Bus Interface Card for superior detection and false alarm immunity •Attached to NX-8E control panel • Protects all glass types up to standard thickness • Bus interface supports up to 192 addressable of 1/4"(6.4mm)including plate,wired,tempered devices on two-mile loop and laminated glass •Supports three class B loops •Senses through light blinds and unlined drapes. Suitable for use in occupied areas on the perimeter loop North America Latin America Fi n Po nt T 855-286-8889 T 561-998-6114 Addressable Point ID Systems Specifications Model AP750-ID 5845-ID SI-ID 4140-ID NX-2192E Housing material Flame retardant ABS Flame retardant ABS Flame retardant ABS Flame retardant ABS Operating voltage 8 to 27V(as supplied 8 to 27V(as supplied 8 to 27V(as supplied 8 to 27V(as supplied by NX-2192E) by NX 2192E) by NX-2192E) by NX-2192E) Signaling voltage 4 to 9V 4 to 9V Current draw 250 pA typical avg. 250 pA typical avg. 250mA 2.2A max. 170mA standby max. 3mA with LED 3mA with LED momentarily on momentarily on Microphone Omni-directional electret Detection range 50 ft.(15.2m) Mounting height 6 to 10 ft.(1.8 to 3m) Number of curtains 7 Input loop resistance >1 MO —Open >1 MO —Open (47k EOL included) 47k±5% —Single EOL 47k±5% —Single EOL 94k±5%—Double EOL 94k±5% — Double EOL >200 — Short >200 —Short Operating temperature 32°F-131°F 14°F-120°F 32°F-131°F 32°F-131°F 32°F-122°F (0°C-55°C) (-10°C-50°C) (0°C-55°C) (0°C-55°C) (0°C-50°C) Relative humidity 10%-90% 10%-90% 10%-90% 10%-90% (non-condensing) (non-condensing) (non-condensing) (non-condensing) Maximum line length 10,000 ft.(3km) 10,000 ft.(3km) 10,000 ft.(3km) 10,000 ft.(3km) Dimensions(WxDxH) 2.9 x 2.2 x 5.1 in. 3.13 x 1.7 x 4.2 in. 3.3 x 1.3 x 2.8 in. 6.8 x 2.0 x 4.8 in. 2 x 1.25 x 9 in (74 x 56 x 129mm) (80 x 43 x 108mm) (84 x 33 x 71 mm) (173 x 51 x 122mm) (51 x 32 x229mm) Regulatory UL 639,FCC,CE FCC,CE UL 365,UL 609, UL 365,UL 609, UL 365,UL 609, UL 985,UL 1023, UL 985,UL 1023, UL 985,UL 1023, UL 1610,FCC,CE UL 1610,FCC UL 1610,UL 1635, UL 1637,FCC,CE Ordering Information AP750-ID Addressable AP750W PIR Motion Sensor Features Adaptive Signal Processing that Analyzes Size,Speed,Shape and Adaptive Alarm Threshold.Provides 4 Separate Curtain Coverage Patterns w/50' Range.Flat Wall or Corner Mounting.UL,FCC,CE Approved 5845-ID Addressable ShatterPro Glassbreak Sensor.Featuring Pattern Recognition Technology for Superior Detection and False Alarm Immunity,it Protects All Glass Types Up to a Thickness of 1/4".It Has a Range of 20'and Can Be Wall or Ceiling Mounted.FCC,CE Approved SI-ID Single Input Device,Addressable.The Addressable Single Input Device Connects a Single Non-Addressable Device to the NX-2192 Interface Card.UL,FCC,CE Approved 4140-ID Four Input,Four Output Device,Addressable.The Addressable Four Input,Four Output Device Allows Connection of Up to 4 Non- Addressable Devices to the NX-2192 Interface Card.Supports 4 Inputs and 4 Unsupervised Outputs(Horns,Bells,Sirens,Etc.). UL,FCC Approved interlogix NX-2192E NetworX Pinpoint Interface Card Attaches to the NX-8E Control Panel.Supports Up to 192 Addressable Devices on a Two-Mile Loop.Supports Two Class B Loops and One Class A Loop.UL, FCC,CE Approved interlogix.com NX-8E NetworX Control Panel Includes Owner's Manual and Installation Specifications subject to change without notice. Instructions.Keypad and Transformer Sold Separately.UL,FCC, ©2014 United Technologies Corporation. CE Approved All rights reserved. Interlogix is part of UTC Building&Industrial Systems, a unit of United Technologies Corporation. 302-3647 2014/03 (73949) CONVENTIONAL DETECTION 5600 Series Mechanical f SYSTEM Heat Detectors �$ SENSOR' Models Available ,,::(il,,,: Single-circuit Models '. 5601 135°F Fixed Temperature / Rate-of-Rise 110U/rj ' ti'` 5602 194°F Fixed Temperature / Rate-of-Rise ;. 5603 135°F Fixed TemperatureR. _': 5604 194°F Fixed Temperature ,jM1 E % , Dual-circuit Models �''%- • :ve;:'';<'z 5621 135°F Fixed Temperature / Rate-of-Rise • ,.40—.-6.--'''•• 5622 5622 194°F Fixed Temperature / Rate-of-Rise ' �...: 5623 135°F Fixed Temperature l". `.`.�. °`' 5624 194°F Fixed Temperature C C.. Product Overview Multiple configurations available to System Sensor's 5600 series mechanical heat detectors offer a low-cost means for satisfy a broad range of installations: property protection against fire, and for non-life-safety installations where smoke • Single-and dual-circuit models detectors are inappropriate. • Fixed temp and combination fixed-temp/rate-of-rise Multiple configurations. The 5600 series offers a full-line of configurations to • 135°F or 194°F ratings. accommodate a broad range of applications. Both single- and dual-circuit mod- els are offered, each available for low- and high-temperature ratings with either Simple to read alphanumeric text on fixed temperature or combination fixed temperature/rate-of-rise (ROR) activa- the exterior of the detector indicates tion. The ROR element of the fixed/ROR models is restorable, to activation method and temperture rating accommodate field-testing the unit. Easy to use terminal screws that provide Installation flexibility. To satisfy a variety of installations, the 5600 series a more positive wiring connection easily mounts to single-gang and octagonal back boxes. These models also A broader range of back box accommodate four-square back boxes, when used with a square to round mounting options: plaster ring. The mounting bracket is reversible to allow for flush- and • Single gang surface-mount back box installations. • 3.5" and 4" Octagonal • 4" square with square to round Visual identification. The 5600 series provides clear markings on the exterior plaster ring of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Reversible mounting bracket for degrees Fahrenheit and Celsius. Fixed temperature models are identified "FX", flush and surface mount installations while combination fixed/rate-of-rise units are marked "FX/ROR". The 5600 series also provides a post-activation indicator in the form of a collector. Once ® MEA the detector has been activated, the collector drops from the unit, to easily approved identify the specific unit in alarm. LISTED 199-03-E ,, 321 ® v APPROVED ERvs 3016008 7270-1209:227 Engineering Specification Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed tem- perature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C)per minute.The detector shall include a reversible mount- ing bracket for mounting to 3Y2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise ele- ment of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Electrical Specifications Operating Voltage/ Contact Ratings 6—125 VAC/ 3A 6—28 VDC/ 1A 125 VDC/0.3A 250 VDC/0.1A Physical Specifications Maximum Installation Temperature Alarm Temperature Rate-of-Rise Threshold 5601, 5603, 5621, and 5623: 100°F(38°C) 5601, 5603,5621,and 5623: 135°F(57°C) 15°F(8.3°C) rise per minute 5602, 5604, 5622, and 5624: 150°F(65.6°C) 5602, 5604, 5622,and 5624: 194°F(90°C) (models 5601,5602,5621,and 5622 only) Operating Humidity Range Input Terminals Mounting 5 to 95%RH non-condensing 14-22 AWG 3°h-inch octagonal back box 4-inch octagonal back box Dimensions with mounting bracket Single gang back box Diameter:4.57 inches(11.6cm) Weight 4-inch square back box with a square to round Height: 1.69 inches(4.3cm) 6 oz. (170 grams) plaster ring Ordering Information Temperature Model Circuit Rating Activation UL Protected Spacing—10 Foot Ceiling* 5601 Single 135°F(57°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single 194°F(90°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual 135°F(57°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual 194°F(90°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor—Far East System Sensor—India 3825 Ohio Avenue Ph:905.812.0767 Ph:86.29.524.6253 Ph:85.22.191.9003 Ph:91.124.237.1770 x.2700 St.Charles, IL 60174 Fx:905.812.0771 Fx:86.29.524.6259 Fx:85.22.736.6580 Fx:91.124.237.3118 Ph:800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor—Australia System Sensor—Russia Fx:630/377-6495 Ph:44.1403.891920 Ph:65.6273.2230 Ph:613.54.281.142 Ph:70.95.937.7982 Documents-on-Demand Fx:44.1403.891921 Fx:65.6273.2610 Fx:613.54.281.172 Fx: 70.95.937.7983 800/736-7672 x3 www.systemsensor.com ©2004 System Sensor.The company reserves the right to change product specifications without notice. A05-0351-000.2/04.#994 12/24VDC r Carbon Monoxide Detector with SafeTestTM 260-CO r=r, Overview Standard Features The SafeAirTM 260-CO carbon monoxide(CO)detector is an accu- • 10-year end-of-life signal rate and reliable means of alerting building occupants of potentially • SafeTesf feature —functional test with spray of real CO gas dangerous levels of CO in the protected area.The internal electro- chemical sensor communicates with a sophisticated on-board • Advanced electro-chemical sensing technology microprocessor that accurately tracks CO levels over time. • Wiring option activates sounders of all connected detectors This commercial-grade detection technology results in quick when any one of them goes into alarm response, reliable sensing,fast reset time, and superior false alarm • Deep housing with plenty of room for wiring immunity. Its small size allows the 260-CO to blend inconspicu- ously with any decor, and its smooth contoured design is compat- • UL 2075 compliant ible with both residential and commercial environments. • Transmits sensor end-of-life to the supervising panel and cen- Unaffected by normal indoor temperature variations,the 260-CO tral station if the system is monitored automatically adjusts for environmental changes and operates • CO sensitivity conforms to UL 2034 requirements reliably under a wide variety of conditions. It also monitors its own • performance and compensates for sensitivity drift throughout the Built in trouble/power supervision relay course of its service life. • Self-diagnostics keep the device operating optimally through- The 260-CO features the SafeTestTM functional test feature,which out its service life facilitates testing with real CO gas.SafeTest meets the functional • 12 or 24VDC operation and 150mA Form C relay test requirement in NFPA 720, 2009/2012 editions. • Large SEMS terminals ease wiring installation 14 to 22 AWG Like all CO detectors,the 260-CO has a limited service life. But • One-touch TEST/HUSH button simplifies local operation unlike most,which last only six years,the 260-CO's advanced sensor features a service life rated at 10 years.When it approach- • Integrated 85 dBa temporal-4 sounder for local notification es this point,the 260-CO's end-of-life timer automatically triggers • On-board LED provides local alarm and trouble indication a warning that indicates the device must be serviced.This warning annunciates at the detector, as well as at the control panel,and • Inconspicuous footprint and attractively contoured design optionally at a remote monitoring station. • Adapter plate simplifies replacing ESL 240-COe detectors An integrated temporal-4 sounder provides local signaling capability for the 260-CO,and it easily interfaces with any intrusion or fire alarm system by means of its output relay. Its low current draw results in little additional demand on the system power supply. Page 1 of 4 DATA SH ESL85001-0632 interlogix.com Not to be used for installation purposes. Issue 1 Application ✓ Centrally located on every habitable level of the building and in every HVAC zone based on an engineering evaluation con- The SafeAir 260 CO Carbon Monoxide Detector is intended for ordinary indoor-dwelling unit applications in both residential and sidering potential sources and migration of carbon monoxide commercial occupancies, including single/multiple family residential 1( On the ceiling in the same room as permanently installed fuel occupancies, hotel rooms, dorm rooms,and other areas approved burning appliances by the authority having jurisdiction(AHJ).The 260-CO detector ✓ In any area required by local building codes, legislation, or the can connect to either UL 985(Household Fire Warning)or UL 864 authority having jurisdiction (Commercial Fire)control panels. It is not intended for use in indus- V On a firm, permanent surface trial applications such as gasoline refineries or parking garages, 1/ Do not install the CO detector: which require different listings. The 260-CO is a four-wire device that uses a Class 2 output from Do not install the CO detector: a control panel. Nonetheless,the primary alarm notification de- X Within 5 ft. (1.5 m)of any cooking appliance vice remains the 260-CO's internal sounder with the control panel X Within 10 ft. (3 m)of a fuel-burning appliance secondary to these purposes.The 260-CO is not a substitute for life safety devices,and should be only considered as an integral part of X Near air conditioners,heating registers,and any other ventilation a comprehensive safety program. source that may interfere with CO gas entering the detector X Where furniture or draperies may obstruct the airflow Selecting a suitable location is critical to the correct operation of CO detectors. Install the 260-CO in accordance with NFPA 720 X In a recessed area Standard for the Installation of Carbon Monoxide(CO)Detection and Warning Equipment. Place wall-mounted detectors at least 5 ft. (1.5 m)up from the floor. For ceiling mounted applications, Operation place the detector at least 1 ft. (0.3 m)from any wall. SafeTest functional test:This test facilitates the use of CO test Recommended CO detector locations: spray to verify the correct operation of the detector,which is man- ✓ Within 10 ft. (3 m)of all sleeping areas, including areas such datory per NFPA 720.The SafeTest mode is activated by pressing as hotel rooms and dorm rooms. and holding the test/hush button for 5-10 seconds.While in Saf- eTest mode, directing UL classified CO testing spray at the sensor ✓ In a suitable environment: areas with a temperature range of 40 to 100°F(4.4 to 37.8°C)and with a relative humidity port will result in the activation of the alarm relay, and the sounder range of 10 to 90% noncondensing. and red LED in a temporal-four pattern. Pressing and holding the test/hush will exit SafeTest mode. ✓ In residential dwellings, locate detectors in every bedroom and on each level.At a minimum, place one detector outside Distinct temporal-four sounder alarm:The 85 dB temporal- the sleeping areas. four sounder provides a distinctive alarm notification that is easy to differentiate from smoke alarm notification devices.The alarm beeps four times, rests five seconds and then repeats the pattern. Test/hush button: Use the test/hush button to test the alarm and 1.1 ��O P- silence an activated alarm. Pushing the test/hush button silences the integral sounder for five minutes.The red alarm light stays on r , ® ® and if CO is still present after five minutes,the detector once again �- D = sounds in the temporal four pattern. , �._ , �� End of sensor life indicator:The detector uses both a flashing I ■111111, = green LED and intermittent sounder chirps to indicate that the de- O tector needs replacing.To silence the detector, push the test/hush ijriMillik I button.The detector also begins signaling a trouble when the CO sensor is approaching end-of-life. 0 Recommended locations for CO detectors Common trouble relay:The trouble relay opens to indicate a trouble condition upon lost power,CO sensor cell trouble, or cell Always check with your local building codes, end-of-life.When connected to a listed control panel,the trouble legislation,and Authority Having Jurisdiction relay can report a trouble condition locally at the panel and option- for specific CO location requirements in your area ally at the central station, if the system is monitored. Recommended CO detector locations in commercial occupancies: ✓ Outside each separate sleeping area in the immediate vicinity WARNINGS:Connect the CO detector only to a zone dedicat of the bedrooms(including areas such as hotel rooms and ed exclusively for CO detection and that is monitored 24 hours dorm rooms) a day. Do not connect to an initiating circuit with fire or security devices. Failure to properly install,test, and maintain a CO V On every occupied level of a dwelling unit, including base- detector may cause it to fail, potentially resulting in loss of life. ments, but excluding attics and crawl spaces Page 2 of 4 DATA SHEET ESL85001-0632 Not to be used for installation purposes. Issue 1 Installation The 260-CO/240-COe . The 260-CO Carbon Monoxide Detector is a four-wire device adapterplate U designed to use a Class 2 output from a control panel or auxiliary Use a 255 0 COPLT adaptor power supply Listed to UL 985 or 864 standards. plate when replacing a 240 -� COe with a 260-CO to cover All wiring must conform to the NFPA 70 National Electric Code, UL any paint discoloration left 2075, NFPA 720, and applicable codes. Use 14 to 22 AWG wire. behind. i 17 - Wiring Single device, Multiple devices, Multiple devices, single zone single zone separate alarm,trouble zone _. EOL device EOL device EOL device c FM � Nc ��� Nc l ��� _\\ NC RI NC 17 i_yl ��n ]� �iC 71 O No '_0�7 NO 1 Ir J Alarm , - �� c W. c I IDC Power f� Nc :0] NC +Iw. Iw. -I. — - w, Tandem Interconnect: Use a Single Circuit Reversal Module when wiring multiple 260-CO detectors for tandem NC ,cel NC interconnect. On alarm,the ;:O; Ne module disconnects the detec- tor from its normal power supply c e and applies reverse polarity from I NC I E NC the notification appliance circuit. +I.1 EOL device EOL device -I.v -II[oi This causes the sounders to I I + I activate on other 260-CO detec- e z m a e tors that are on the same loop. Onlythe initiatingdetector will ESL 405 ESL 405 Polarity Reversal Polarity Reversal sound and blink red.All others Module Module in tandem mode will sound but 1M NC 1 8 5 7 li_o�7i NC 1 3 5 , not blink red. — ;0; 0 0 ® ® il,ell-c` at t9 t9 i0: il_o•]i NO I Si ® 0 0 0 0 0 0 8 0 1 0 Alarm Power NAC Alarm SUPV Power NAC IDC Control Panel IDC IDC Control Panel Page 3 of 4 DATA S H E E'i ESL85001-0632 Not to be used for installation purposes. Issue 1 Specifications Input voltage 12 or 24 VDC supplied by UL 985 or UL 864 listed control panel or resettable auxiliary power supply Current consumption Normal 20 mA Alarm 40 mA(75 mA in test) Alarm relay 150 mA at 33 VDC Type Form C UL rating Zone Common trouble relay 150 mA at 33 VDC Type Normally opened held closed with power applied UL rating Common Sensor life 10 years from date of manufacture Sounder 85 dB Compatible control panel Listed to UL 985 or 864 standards Compatible electrical box 2-1/2 in.(64 mm)single-gang Wire size 14 to 22 AWG(0.25 to 2.0 mm2) Dimensions(W x L x D) Detector 3.1 x 4.6 x 1.4 in.(7.8 x 11.7 x 3.6 cm) Adapter plate 4.5 x 6.5 x 0.2 in.(11.4 x 16.5 x 0.5 cm) Color White Operating environment Temperature 40 to 100°F(4.4 to 37.8°C) Relative humidity 10 to 90%noncondensing CO sensitivity 70 ppm,60 to 240 minutes 150 ppm, 10 to 50 minutes 400 ppm,4 to 15 minutes North America T 885-286-8889 Asia T852-2907-8108 Ordering Information F 852-2142-5063 Model Description Australia 260-CO SafeAir Carbon monoxide detector,alarm&trouble relays, T 61-3-9239-1200 sounder,end-of life signal, 12/24VDC F 61-3-9239-1299 250-COPLT-5PKG Adaptor plate for use when replacing the 240-COe CO detector with a 260-CO Europe ESL 405-01 Polarity Reversal Module,24 VDC T 32-2-725-11-20 ESL 405-03 Polarity Reversal Module, 12 VDC F 32-2-721-40-47 ESL 405-05 Polarity Reversal Module, 12/24VDC Latin America CO Gas Test Spray Functional CO gas test spray Solo C-6 from SDI T 561-998-6114 (www.sdifire.com)available through security distribution. F 561-994-6572 interlogix interlogix.com Specifications subject to change without notice. ©2012 Interlogix. Interlogix is part of UTC Climate Controls&Security, a unit of United Technologies Corporation. All rights reserved Page 4 of 4 DATA SHEET ESL85001-0632 Not to be used for installation purposes. Issue 1 SYSTEM �$ SENSOR• Mini-Horns - - - . - "ter The SpectrAlerr Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. SPECTRIert A N C Features The MHR and MHW mini-horns operate at 12 and 24 volts and are •12 and 24V operation ideal for hotel,motel or residential fire system applications,where a smaller notification device is desired.The mini-horns offer high •High and low volume settings and low volume settings,and temporal or non-temporal tones. The •Temporal and non-temporal tones horns can be mounted to single gang back boxes for aesthetically •Mounts to single gang back box sensitive applications. Synchronization is also provided when using the MDL module. •Compatible with MDL sync module •Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-Alert-sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings UL S N 411> MEA LISTED APPROVED approved 5401 3028007 MEA7-07-E 7135-1653196 SpectrAlerr Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box.Mini- horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.When used with the Sync•Circuit'"Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9'W x.45"D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:single-gang back box Flush:4"x 4"BBD deep back box(23/4"deep) Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output(dBA) Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non-temporal High 72 71 75 74 80 79 4 Non-temporal Low 70 69 73 72 78 77 Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini-Horn,Red MHW Mini-Horn,White *--. SYSTEM ®2007 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Usit systemsensoccom for �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0414-000.1/07•#1743 ESL 405 0 Polarity Reversal Relay Modules LISTED Installation Instructions Description ESL 405 polarity reversal relay modules are designed for use with ESL smoke detectors that have built-in sounders.On alarm,the module disconnects the 0+ N -I' +� detectors from their normal power supply and applies reverse polarity from the 1 _ K1 a _ 2 notification appliance circuit.Applying reverse polarity causes the sounders on detectors not in alarm to activate. 3 K,b 4 Q* Application Notes 5 ,,,K1 6 Use the following guidelines to determine the appropriate application of the relay modules: • For 2-wire applications,DO NOT connect pull stations,heat detectors or other 7 8 shorting devices. • Use a single reversal module for 4-wire applications. 405-01 and 405-03 • For 2-wire applications,use one reversal module for each initiating circuit. Installation All wiring must conform to National Electrical Code(NEC)and/or local codes having jurisdiction. * Standby terminal connections: The module comes assembled for installation on a standard 4 inch commercial electrical box. Application Terminal 5 Terminal 7 Use the following instructions to install the module in a control panel: 24V fire --1- control +control panel 1. Slide the terminal/circuit board off the gray plastic mounting bracket. 12V burglary/fire +� 2. Remove the two screws holding the plastic mounting bracket to the metal plate. combined control panel 3. Place double-sided adhesive tape on the back of the plastic mounting bracket and stick the bracket inside the control panel enclosure. 4. Slide the terminal/circuit board back into the plastic mounting bracket. 5. Strip 3/8"of insulation from each conductor and insert each one under the appropriate screw terminal.Refer to the wiring diagrams for typical wiring configurations. 6. Tighten the screws and check all wiring connections. WARNING! This device may not be compatible with all power supervision relays.When you use this device on 4-wire circuits,use the ESL 204 series power supervision relay at the end of line.An ESL smoke detector/alarm with a sounder that incorporates an end-of-line/sensitivity relay output may also be used. Wiring Diagrams Two Wire Diagram ESL 2 Wire Sounder smoke detectors Two wire +[C] [0] -Pr 01 initiating — circuit Notification — KC '1711E r r 0 First n End of 405-01 BIC RN Last line device � Appliance diagram ' detector detector Circuit (24VDC)-1-BIC M Notification Appliance ESL 405-01(24VDC) Circuit EOLR Polarity reversal relay *Confirm compatibility when using powered and wire initiating devices. Four Wire Diagram ESL 4 Wire Sounder smoke detectors Switched+RE [0X xl _L M smoke — power —MC (© [Di First Notification LDi r � Last 405-01 — RCdetector Appliance diagram ► • LO] ' detector 3+ Circuit (24VDC)+BIC DIl M Notificationt t t line 405-03 +516ESL 40 5-0 3(12VDC) Appliance ® t® ��®® 0 End of diagram ESL 405-01(24VDC) Circuit EOLR device (12VDC)— [� Polarity reversal relay Initiating NE , Device Circuit DC Specifications Voltage: 405-01 20-30VDC Weight 0.021bs. 405-03 9.2-18VDC Dimensions: Current: Height 2.9"(7.3 cm) 405-01 21mA@24V Width 2.1"(5.3 cm) 405-03 43mA@12V Depth 1"(2.5 cm) Contacts 1A@30VDC resistive Listing UL 864 Product Ordering Model Description 405-01 24VDC, single circuit polarity reversal module, UL & CSFM 405-03 12VDC, single circuit polarity reversal module, UL only in t e r I o g i►�."" 12345 SW Leveton Dr. Tualatin,OR 97062 ©2001 Interlogix,Inc. i PH 503.692.4052 FX 503.691.7566 www.interlogixinc.com Interlogix reserves the right to change specifications without notice. SECURITY&LIFE SAFETY GROUP USA&Canada: 800.547.2556 CleorMe and Stroke!in a can are registered trademarks of Interlogix,Inc. Technical Service:800.648.7424 SafeAir is a trademark of Interlogix,Inc. CADDR ESL CRC I ITI I KALATEL I SENTROL FaxBack:800.483.2495 15845 Rev B 02/01 Installation Instruction for Power Supervision Module 204-6V Model 445A.F okxm atom) 10, contact Oower contact Powerare detector- t — + detector , • LIMP 1111011Pr ilditred CS wtrrll, rr.rlsu�ERu�rIG>t1{ —IIIIIII .. IIII• � (SEE ELECTRICAL 9PECSP �{ • = --g END OF IMIE MICE 204-12/24V olorm last . - contact POwB[ dormOOr11OOt POwer deter c —. + Iw + 1 ,,,,KT,c, ,T . .. . . Epplir.r.„......... :......Niq,. l!, ..... • , + 111111=01....6•iIl._.,... ..,...:.,.....„- ....., uIi„ .U.= ELECT I F dm.* fit# - .. ■i M simel:,,a,-.4.0 . Beta • :; ® t 204-12/24V !�! m corirc} ILfirst ., oiwn cart= pD1VM cOMOcr Wm.. Wawa` • 119.,IX darectot /- — + il :+ Ir — + ^2. ,, . .,.`41Tra \,, .4 •002 4 3 2 1 7 5 4 3 2 1 qct --- � _..til Ad �".J.4 -t 5 MINI 5 I SEE Pectrncµsyscst MI MIMI brown avatn— END OF LK DEVICE 'ntiniWt + ELECTRICAL SPECIFICATIONS Power Supervision Unit 204-6V Power Supervision Unit 204-12/24V Operating Voltage 5.1 - 15 VDC Operating Voltage 8.5-33 VDC Operating Current 33 mA @ 6 VDC;66 mA ® 12 VDC Operating Current 14 mA ® 12 VDC;28 mA 0 24 VDC Contact Rating(resistive) 2A 0 26 VDC or 115 VAC Contact Rating (resistive) 2 A fi! 26 VDC or 115 VAC INSTALLATION INSTRUCTIONS 1.Connect brown initiating leads as indicated such that the end of line 3.Neatly dress wires and power supervision unit into device is connected in series with the power supervising contact. junction box. (see wiring diagram) 4.Mount detector according to manufacturers installation 2.Connect appropriate control leads as shown. Red incoming and red instructions. from module to terminal 1. Black incoming and black from module to terminal 2. E s TL CSentrolor ,Inc. porate Headquarters: Sentrol,Inc.reserves the nght to t 2345 5W Levetan Drive change specifications without notice. Tualatin,OfI 97062 U.S.&Canada:800-547-2556 0i994 Sentra!,Inc. �.j t.*Q.D. . E.S E N T R O 1. 1 N C 503-692-4052 Technical Support:600-648-7424 ?:'Printed on recycled paper E-1433-16132']fi" ,. 10266 REV.El 4- ////per/L�/ER��/� //rs0/1//� + �z�. . 1. ) PS-12180 12 Volt 18.0 AH + i ' .° Rechargeable Sealed Lead Acid Battery111 We've Got The Power.'"' Features • Absorbent Glass Mat (AGM) technology for superior 0111111111116 performance Sealed Rechargeable • Valve regulated, spill proof construction allows safe Battery operation in any position powfR/�,/D//SuN MODEL PS92180NB Power/volume ratio yielding unrivaled energy density 12 Volt 18.0 Amp Hr. �5 r� 911® e:'o • Rugged impact resistant ABS case and cover (UL94-HB) MH2�5 Pb • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified CE • U.L. recognized under file number MH 20845 M�,o,, f it l$""I M Terminals (mm) Performance Specifications • �3.4� Nominal Voltage 12 volts(6 cells) F2:Quick g disconnect AMP, INC. 0 116.35 Nominal Capacity Faston tabs, 0.250"x 0.032" I-7.95-1 1 20-hr. (900mA to 10.50 volts) 18.0 AH • PS-12180 NB2:Tin =0.8 10-hr. (1.7A to 10.50 volts) 17.0 AH plated brass post 1 14 l H 5-hr. (3.2A to 10.20 volts) 16.0 AH with 5mm nut&bolt connectors O 61 12 1-hr. (11.1A to 9.00 volts) 11.1 AH 15-min. (34.3A to 9.00 volts) 8.58 AH Physical Dimensions: in(mm) Approximate Weight 12.60 lbs.(5.72 kg) Energy Density(20-hr.rate) 1.53 W-h/in3(93.51 W-h/l) T w Specific Energy(20-hr.rate) 17.14 W-h/Ib(37.79 W-h/kg) 0@ ® 0 I Internal Resistance(approx.) 14 milliohms Max Discharge Current(7 Min.) 54.0 amperes I I' ,__IL_, �� n I Max Short-Duration Discharge Current(10 Sec.) 180.0 amperes Shelf Life(%of nominal capacity at 68°F(20°C)) s---c7,,------ 1 Month 97% efielF sm1/7: HT H 3 Months 91% MODEL PS NB "911"°Nr 80 6 Months 83% .w.... ._ """" Operating Temperature Range Charge -4°F(-20°C)to 122°F(50°C) Discharge -40°F(-40°C)to 140°F(60°C) 1:7.13(181) W:3.00(76) H:6.59(167) HT:6.59(167) Case ABS Plastic Tolerances are+/-0.04 in.(+/-1mm)and+/-0.08 in.(+/-2mm)for Power-Sonic Chargers....PSC-122000A, 124000A, 122000A-C, 124000A-C height dimensions.All data subject to change without notice. To ensure safe and efficient operation always refer to the latest edition of our Technical Manual,as published on our website. All data subject to change without notice. www.power-sonic.com POWER, 4,/""""""""""""""""" PS-12180 12 Volt 18.0 AH �����������%/2SON/C Shelf Life &Storage Discharge Characteristics 100 14.0 III 1 I I I I 1 1 e Charging isnot Ambient Temperature20°C 68°F necessary unless ( ) O 100%of capacity 13.0 ais required. ___ ix 80 j ----- 5°C Charging before use is necessary y 12.0 __ (41°F)- to help recover rn full capacity. w aa) 60 c 11.0 , `o .�` Charge mayfail to restore full o 0.90 w 40°C 30°C 20°C capacity.Do not 10.0 1.8 - 'ti 40 (104°F) (86°F) (68°F) let batteries reach this state. E 3.6 C r - F 9.0 vs 0 9.0 Final 0 2 4 6 8 10 12 14 16 18 20 Voltage 18 Standing Period (Months) 8.0 36 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 Discharge Time vs. Discharge Current I-* min r • h r 1 Discharge Time 20 15 10 \ Life Characteristics in Stand-By Use t \ Ambient Temperature 20°C(68°F) m 5 Final s 0 100 - E Voltage r nol111111111111minprim m 2 10.5V \\ •5 80 rn 10.2V fl- r`a to 60 N ' 1 \ 40 Float Charging Voltage 9.6V \\ o 2.25-2.30 V/Cell 30 00) 20 Y d cG C_ \ 0 F 9.0V 0 1 2 3 4 10 \ \40°C(104°F) 20°C (68°F) Years 0°C (32°F) 5 - 8.1V 1 Life Characteristics in Cyclic Use 0.90 1.8 3.6 9.0 18 36 120 Discharge Current(A) 100 z---\\------,,,,,„ii Charging o ,, 80 Cycle Applications:Limit initial current to 5.4A.Charge until battery voltage coo (under charge)reaches 14.4 to 14.7 volts at 68°F(20°C).Hold at 14.4 to 14.7 a 60 -Discharge Discharge Discharge volts until current drops to under 180mA.Battery is fully charged under these Depth 100% Depth 50% Depth 30% conditions,and charger should be disconnected or switched to"float"voltage. 0 40 - d 1.Discharge Current 0.2C(Final Voltage 1.7V/Cell) "Float"or"Stand-By"Service:Hold battery across constant voltage source of m 20 2.Charge Current:0.1C I I I 13.5 to 13.8 volts continuously.When held at this voltage,the battery will seek its lY 3.Ambient Temperature:20°C to 25°C(68°F to 77°F) own current level and maintain itself in a fully charged condition. 0 0 200 400 600 800 1000 1200 Note:Due to the self-discharge characteristics of this type of battery,it is Number of Cycles imperative that they be charged within 6 months of storage,otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for"C-Series downloads,such as product catalogs,material safety data sheets(MSDS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Technical department for advice if you have difficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1-619-661-3648 Fax:+1-650-366-3662 national-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com battery@power-sonic.com CORPORATE OFFICE • 7550 Panasonic Way • San Diego,CA 92154 • USA• Tel:+1-619-661-2020 • Fax:+1-619-661-3650 408 1M