Loading...
HomeMy WebLinkAboutA16-0003_Silent Knight SK-Zone_1452118560.pdfMounting The SK-Zone mounts directly to 4-inch square electrical boxes (see Figure 2). The box must have a minimum depth of 21/8 inches. Surface mounted electri- cal boxes (SMB500) are available from Silent Knight Wiring NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. This module is intended for power-limited wiring only. 1. Install module wiring in accordance with the job drawings and appropri- ate wiring diagrams. 2. Set the address on the module per job drawings. 3. Secure module to electrical box (supplied by installer), as shown in Figure 2. Figure 2. Module Mounting: ISOLATED QUADRANT C1066-00 SK-460-012 1 I56-3440-001 SK-Zone interface Module BeFore inStalling This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the opera- tor and local authority that the system will be temporarily out of service. Dis- connect power to the control panel before installing the modules. NOTICE: This manual should be left with the owner/user of this equipment. general deScription The SK-Zone Interface Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with this module. coMpatiBility requireMentS To ensure proper operation, this module shall be connected to a compatible Silent Knight system control panel only (list available from Silent Knight). Figure 1. controlS and indicatorS: C1059-00 SpeciFicationS Normal Operating Voltage: 15 to 32 VDC Maximum Current Draw: 5.1 mA (LED on) Average Operating Current: 270µA (LED flashing) EOL Resistance: 3.9K Ohms Maximum IDC Wiring Resistance: 25 Ohms External Supply Voltage (between Terminals T10 and T11) DC Voltage: Regulated 24 VDC Ripple Voltage: 0.1 Volts RMS maximum Current: 90mA per module Temperature Range: 32˚F to 120˚F (0˚C to 49˚C) Humidity: 10% to 93% Non-condensing Dimensions: 41/2˝ H × 4˝ W × 11/4˝ D (Mounts to a 4˝ square by 21/8˝ deep box.) Accessories: SMB500 Electrical Box I56-3440-001inStallation and Maintenance inStructionS 12 Clintonville Road, Northford, CT 06472 203.484.7161; Fax: 203.484.7118 www.silentknight.com coMpatiBle tWo-Wire SySteM SenSor SMoKe detectorS For uSe With SK-Zone interFace Module With Zone identiFier a: Detector Compatibility Detector Base Base Max Model ID Type Model Identifier Detectors 1451 A Ionization B401/B A 20 2451 A Photoelectric B401/B A 20 2451TH A Photoelectric with Thermal B401/B A 20 1400 A Ionization N/A — 20 2400 A Photoelectric N/A — 20 2400TH A Photoelectric with Thermal N/A — 20 1100 A Ionization N/A — 20 1151 A Ionization B110LP/B401 A 20 2100 A Photoelectric N/A — 20 2100T A Photoelectric with Thermal N/A — 20 2151 A Photoelectric B110LP/B401 A 20 *Used in combination with MTL isolator model MTL3043. Figure 3. interFace tWo-Wire conventional detectorS, nFpa Style B:(+)(–)(+)(–)(+)(–)+–LISTED BATTERY-BACKUP SWITCHED REGUALTED DC POWER SUPPLY POWER TO THE INTERFACE MODULE MUST BE EXTERNALLY SWITCED TO RESET THE DETECTORS. A RELAY CONTROL MODULE CAN BE USED TO SWITCH POWER FROM A STANDARD POWER SUPPLY (SEE FIGURE 5). OPTIONAL BRANCH CIRCUITTO NEXT INTERFACE MODULE. MODULE SUPERVISES SUPPLY VOLTAGE ANDDETECTOR LOOP. (+) (–) TERMINAL WIRING MUST BE POWER LIMITED. TO NEXTDEVICE INTERFACE MODULE SIGNAL LINE CIRCUIT (SLC) 32 VDC MAX.TWISTED PAIRIS RECOMMENDED CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY. FROM PANEL OR PREVIOUS DEVICE 3.9K EOL RESISTOR (INCLUDED) A2143-10 DO NOT LOOP WIRE UNDER TERMINALS. BREAK ALL WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. DETECTORS MUST BE UL LISTED COMPATIBLE WITH MODULE. INSTALL DETECTORS PER MANUFACTURER’S INSTALLATION INSTRUCTIONS *NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE.+–DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR SECURITY DEVICES ON THE SAME MODULE. C1061-00 Figure 4. interFace tWo-Wire conventional detectorS, nFpa Style d:(+)(–)(+)(–)(+)(–)(+) (–)LISTED BATTERY-BACKUP SWITCHED REGUALTED DC POWER SUPPLY POWER TO THE INTERFACE MODULE MUST BE EXTERNALLY SWITCED TO RESET THE DETECTORS. A RELAY CONTROL MODULE CAN BE USED TO SWITCH POWER FROM A STANDARD POWER SUPPLY (SEE FIGURE 5). OPTIONAL BRANCH CIRCUITTO NEXT INTERFACE MODULE. MODULE SUPERVISES SUPPLY VOLTAGE ANDDETECTOR LOOP. TERMINAL WIRING MUST BE POWER LIMITED. 3.9K EOL RESISTOR REQUIRED AT TERMINALS8 & 9 (INCLUDED) A2143-10 DO NOT LOOP WIRE UNDER TERMINALS. BREAK ALL WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. DETECTORS MUST BE UL LISTED COMPATIBLE WITH MODULE. INSTALL DETECTORS PER MANUFACTURER’S INSTALLATION INSTRUCTIONS INTERFACE MODULE TO NEXTDEVICE SIGNAL LINE CIRCUIT (SLC) 32 VDC MAX.TWISTED PAIRIS RECOMMENDED CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY. FROM PANEL OR PREVIOUS DEVICE *NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. + - + - DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR SECURITY DEVICES ON THE SAME MODULE. C1062-00 Figure 5. relay control Module uSed to diSconnect a poWer Supply:(+)(–)(+)(–)(+)(–)(+)(–)(+)(–)SIGNAL LINE CIRCUIT (SLC) 32 VDC MAX.TWISTED PAIRIS RECOMMENDED CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY. FROM PANEL OR PREVIOUS DEVICE RELAY CONTROL MODULE TO NEXTDEVICE POWER LIMITED DC POWER SUPPLY, LISTED FOR FIRE PROTECTION WITH BATTERY BACKUP *NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. C0945-00 SK-460-012 2 I56-3440-001 ©2009 Honeywell International Inc.