Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A16-0011_A16-0011 DATA SHEETS_1455834720.pdf
CSWC 210 Marmot Lane #B5 * PO Box 3913 * Eagle, CO 81631 Phone 970.328.1951 Fax 970.328.1956 www.cswcfire.com Commercial Specialist of Western Colorado, LLC VAIL GOLF AND NORDIC CLUB HOUSE MANUFACTURES DATA SHEETS PART NO DESCRIPTION NFW2-100 FireWarden-100-2 addressable fire alarm control panel, 198 addressable devices on one SLC, built in DACT with modem for remote upload/download. Black NP-100 Intelligent Addressable Photo detector, with base. NP-100R Intelligent Addressable Photo detector with remote test capability for use with DNR(W) duct detector. NP-100T Intelligent Addressable Photo/Thermal detector; with base. NMM-100 Addressable Monitor Module; Supervises either a Class A or Class B circuit of N.D. dry- contact input devices. NDM-100 Addressable Dual Monitor Module; 2 Class B. NC-100R Addressable Relay Module ; Provides 2 Form-C dry contacts that switch together. NOT-BG12LX Addressable Pull Station. DNR InnovairFlex intelligent duct detector, non-relay, does not include head. RTS151 Remote test station; with switch, alarm and power LED’s. FCPS-24S6 6.0 amps, 120 VAC remote charger power supply. Includes main printed circuit board, transformers and installation instructions. BAT-12120-BP Four (4) BAT-12120 BAT-12120 (12v, 12aH) P2WK White outdoor horn strobe PC2W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, 30,75,110,115 cd SCW Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, 30,75,110,115 cd PR-1 Relay, SPDT, Multivolt, 24VDC, 24/115VAC DN-60602:A1 • 12/07/2010 — Page 1 of 6 FireWarden-100-2(E) Rev 3 Intelligent Addressable FACP Addressable Fire Alarm Control Panel DN-60602:A1 7101cov.jpgGeneral The Notifier FireWarden-100-2 Rev 3 (NFW2-100) with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The ’s quick-remove chassis protects the electronics during con- struction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS, and increased power for the reset- table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local pro- gramming of the control panel using the PS-Tools Upload/Down- load utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows® XP or greater, a com- patible modem, and PS-Tools—the Upload/Download software kit—may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP’s keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, NP-A100, USB port, NAC circuit diag- nostics, a new report has been added to the walk-test that lists untested devices, new device types added: audio telephone type code for NFV-25/50ZST, Photo Supervisory and auto-reset- table Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term “FireWarden-100-2” is used in this document to refer to both the FireWarden-100-2 and the FireWarden-100-2E FACPs (Fire Alarm Control Panels). Like- wise, “NFW2-100” refers to NFW2-100E as well. Features • Listed to UL standard 864, 9th edition. • On-board DACT. • Remote site or local USB port upload/download, using PS- Tools. • Four (4) Style Y (Class B) NAC circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) • Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. • Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or FDU-80, N-ANN-80 or Legacy ACS Annunciators. • ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): –N-ANN-80(-W) Remote LCD Annunciator –N-ANN-I/O LED Driver –N-ANN-S/PG Printer Module –N-ANN-RLY Relay Module –N-ANN-LED Annunciator Module –N-ANN-RLED Annunciator Module alarms only –ROME Relay Option Module Enclosure • ACS & Terminal-mode Annunciators: –ACS Annunciators: Up to 32 Legacy ACM Series annuncia- tors (ACM-16AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. –Terminal-mode Annunciators: Up to 32 Legacy FDU-80 annunciators. • EIA-232 printer/PC interface (variable baud rate) on main cir- cuit board, for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. • Real-time clock/calendar with automatic daylight savings control. • Detector sensitivity test capability (NFPA 72 compliant). Page 2 of 6 — DN-60602:A1 • 12/07/2010 • History file with 1,000-event capacity. • Maintenance alert warns when smoke detector dust accumu- lation is excessive. • Automatic device type-code verification. • One person audible or silent walk test with walk-test log and printout. • Point trouble identification. • Waterflow (nonsilenceable) selection per monitor point. • System alarm verification selection per detector point. • PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: • SLC can be configured for NFPA Style 4, 6, or 7 operation. • SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). • SLC loop maximum length 10,000 ft. (3,000 m.). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): • Four onboard NACs with additional NAC capability using out- put control modules (NC-100). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. • Silence Inhibit and Auto Silence timer options. • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. • Selectable strobe synchronization per NAC. • 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: • Autoprogram (learn mode) reduces installation time. • Custom English labels (per point) may be manually entered or selected from an internal library file. • Three Form-C relay outputs (two programmable). • 99 software zones. • Continuous fire protection during online programming at the front panel. • Program Check automatically catches common errors not linked to any zone or input point. •OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (NFW2-100 requires PS-Tools Programming software, avail- able on www.magni-fire.com). Upload/download system pro- gramming locally to the NFW2-100 Rev 3 in less than one minute. • USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS • AC Power (green) • Fire Alarm (red) • Supervisory (yellow) • Alarm Silenced (yellow) • System Trouble (yellow) • Maintenance/Presignal (yellow) • Disabled (yellow) • Battery Fault (yellow) • Ground Fault (yellow) KEYPAD CONTROLS • Acknowledge/Step • Alarm Silence • Drill • System Reset (lamp test) • 16-key alpha-numeric pad (similar to telephone keypad) • 4 cursor keys •Enter Product Line Information NFW2-100: FireWarden-100-2 Rev 3 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. NFW2-100R: Same as NFW2-100, except in a red backbox. NFW2-100E: Same as NFW2-100, except with 240 VAC opera- tion. 4XTM Reverse Polarity Transmitter Module: Provides super- vised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style Y (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PS Tools: Programming software for Windows®-based PC computer (cable not included), available on www.firelite.com. DP-9692B: Optional dress panel for FireWarden-100-2 Rev 3. TR-CE-B: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid batter- ies with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E Rev 3. PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download program- ming and updating panel firmware. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- net internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DN-60408 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W version for white; see DN-7114.) DN-60602:A1 • 12/07/2010 — Page 3 of 6 N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red or black enclosure (see DN-60242). N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242). N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DN- 7107.) ROME-B: Relay Option Module Enclosure (order ROME-B for black or ROME for red). Provides one N-ANN-RLY Relay Mod- ule already installed. The ROME Series provides mounting space for one additional Relay Module or one addressable Multi- module. (See Installation Sheet PN 53530.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.) ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80-char- acter, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the FireWarden-100-2 Rev 3, see the following data sheets (document numbers) ACM-8R (DN-3558), ACS/ACM Series (DN- 0524), LDM Series (DN-0551), FDU-80 (DN-6820). COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-100T: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W) duct smoke detector housings. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100: Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 oper- ation). SMB500: Used to mount all modules except the NMM-100P. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-25. NZM-100-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-25. NOTE: For more information on Compatible Addressable Devicesfor use with the FireWarden-100-2 Rev 3, see the following datasheets (document numbers): N100-ISO (DN-6994), NP-100 series(DN-6995), NI-100 (DN-6996), NH-100 series (DN-6997), ND-100series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/NDM-100/NZM-100 (DN-6999), NC-100/NC-100R (DN-7000),NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM-100-6 (DN-60150). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm²) and no larger than 12 AWG (3.1 mm²). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. Page 4 of 6 — DN-60602:A1 • 12/07/201060417sys2009.wmfANNUNCIATORS ACS/ACM, LDM ANN-BUS DEVICES N-ANN-80, N-ANN-LED, N-ANN-S/PG, N-ANN-I/O ANN-BUS or EIA-485 in ACS mode (two wires) 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8R) Optional REVERSE POLARITY/ CITY BOX OUTPUT (4XTM) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES EIA-232 INTERFACE (PIM-24) built into the motherboard FireWarden-100-2 Rev 3 Fire Alarm Control/ Communicator NOTE: System can use either ANN-BUS devices OR ACS-mode annunciators. They cannot be used simultaneously. NOTE: System can use either the printer OR the FDU-80. They cannot be used simultaneously.EIA-485 INTERFACE (four wires) FDU-80 Up to 6,000 ft. (1825.8 m) between each FDU-80 in the EIA-485 loop, and between each FDU-80 and the FACP. DUCT DETECTORS ND-100, ND-100R, DNR HEAT DETECTORSNH-100, NH-100R, NH-100H SMOKE DETECTORS NP-100, NP-100T, NI-100, NP-A100 MONITOR/CONTROL NMM-100, NZM-100, NDM-100, N100-ISO, NC-100, NC-100R ADDRESSABLE MULTI-MODULE NZM-100-6, NMM-100-10 MINI-MONITOR NMM-100P PULL STATION NOT-BG12LX PRINTER 24 VDC 24 VDC DN-60602:A1 • 12/07/2010 — Page 5 of 6 Page 6 of 6 — DN-60602:A1 • 12/07/2010 System Capacity • Intelligent Signalling Line Circuits......................................... 1 • Addressable device capacity............................................ 198 • Programmable software zones........................................... 99 • ACS Annunciators .............................................................. 32 • ANN-bus devices................................................................ 16 Electrical Specifications AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2 Rev 3(E): 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm²) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batter- ies require an external battery charger such as the CHG-75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block provides connections for two Style Y (Class B) for a total of four Style Y (Class B) or with an optional ZNAC-92 module converts to four Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documenta- tion and Notifier Device Compatibility Document for listed com- patible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each out- put. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a minimum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CE- B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00” (50.80 cm.) high x 22.5” (57.15 cm.) wide x 8.5” (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. NFPA Standards The FireWarden-100-2 Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: –LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). – AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). – REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) –PROPRIETARY (Automatic, Manual, Waterflow and Sprin- kler Supervisory). – CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). –OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100-2 Rev 3 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635 •FM approved •CSFM: 7165-0028:0235 •MEA: 120-06-E, Volume 2 For ULC-listed version, see DN-60600. NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock® is a registered trademark of and Exceder™ is a trademark of Cooper Notification. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com SYSTEM SPECIFICATIONS DN-6995:D • 2/11/2015 — Page 1 of 2 NP-100(A) Series Addressable Photoelectric Detectors Addressable Devices DN-6995:D • A1-320 General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER’s FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACPs). The NP-100T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory, PN RA100Z(A). The NP-100R(A) is a remote test capable detector for use with DNR(A)/DNRW duct smoke detec- tor housings. Features SLC LOOP • Two-wire loop connection. • Unit uses base for wiring. ADDRESSING • Addressable by device. • Rotary, decimal addressing: 01 – 99 with FireWarden-100-2 and NSP-25, and 01 – 50 with FireWarden-50. ARCHITECTURE • Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. • Sleek, low-profile design. • Integral communications and built-in type identification. • Built-in tamper-resistant feature. • Removable cover and insect-resistant screen for simple field cleaning. OPERATION • Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. • Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. • Visible LED “blinks” when the unit is addressed (communicat- ing with the fire panel) and latches on in alarm. MECHANICALS • Sealed against back pressure. • Direct surface mounting or electrical box mounting. • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring — included). OTHER SYSTEM FEATURES • Fully coated circuit boards and superior RF/transient protec- tion. • 94-V0 plastic flammability rating. • Low standby current. OPTIONS • Remote LED output connection, PN RA100Z(A). Applications Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, especially where smol- dering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. NP-100(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation NP-100(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class B) wiring. NP-100R(A) mounts in a DNR(A)/DNRW duct detector housing. Operation Each NP-100(A) series detector uses one of 99 possible addresses on the FireWarden-100-2 and NSP-25, or one of 50 possible addresses on the FireWarden-50 Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the NP-100(A) series has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar chamber, the NP-100(A) series is approximately two times more respon- sive than most photoelectric sensors. This makes it a more sta- ble detector. NP-100(A) in B210LP(A) Base 2151_2251B_CEILING.png Page 2 of 2 — DN-6995:D • 2/11/2015 NOTIFIER® and FireWarden® are registered trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a FireWarden-100-2 or FireWarden-50 addressable fire alarm control panel. The results of the sensitiv- ity test can be printed off the FireWarden-100-2 or FireWarden- 50 for record keeping. Specification Voltage range: 15 – 32 VDC (peak). Standby current: 300 µA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched “ON”). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Size: 2.1" (5.33 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100(A): 0°C to 49°C (32°F to 120°F); for NP-100T(A): 0°C to 38°C (32°F to 100°F). NP-100R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C – 49°C (32°F – 120°F). Relative humidity: 10% – 93%, non-condensing. Listings Listings and approvals below apply to the NP-100(A), NP- 100T(A), and NP-100R(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or list- ing may be in process. Consult factory for latest listing status. •UL Listed: S1115. •ULC Listed: S1115. •CSFM: 7272-0028:0231. •MEA: 243-02-E Vol. 2. •Maryland State Fire Marshal: permit 2173. •FM approved. Product Line Information NOTE: “A” suffix indicates ULC Listed model. NP-100: Addressable photoelectric detector; B210LP base included. NP-100A: Sames as NP-100 with ULC Listing; B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric detector for use with a DNRA/DNRW duct detector housing; B210LP base included. NP-100RA: Same as NP-100R with ULC Listing for use with a DNRA duct detector housing; B210LPA base included. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Standard European flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DN-6994). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to low- profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with NP-100(A) only; box of 10. WCK-200B: White detector covers for use with NP-100(A) only; box of 10. DN-6997:D • 5/17/13 — Page 1 of 2 NH-100(A) Series Intelligent Addressable Thermal Detectors for FireWarden Series Addressable DN-6997:D • A1-320 General The NOTIFIER NH-100(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors provide open- area protection and are intended for use with FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25) addressable Fire Alarm Control Panels (FACPs). The NH-100(A) and NH-100R(A) sensors provide fixed tem- perature alarm detection at 135°F (57°C). The NH-100R(A) sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute. The NH-100H(A) is a fixed high-tem- perature detector that activates at 190°F (88°C). These ther-mal detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory, the RA100Z. Features SLC loop: • Two-wire SLC loop connection. • Unit uses base for wiring. Addressing: • Addressable by device. • Rotary, decimal addressing: 01 – 99 with FireWarden-100- 2, NSP-25, 01 – 50 with FireWarden-50. Architecture: • Sleek, low-profile, stylish design. • State-of-the-art thermistor technology for fast response. • Integral communications and built-in device-type identifica- tion. • Built-in tamper resistant feature. • Built-in functional test switch activated by external magnet. Operation: • Factory preset at 135°F (57°C) for the NH-100(A) and NH- 100R(A); 190°F (88°C) for the NH-100H(A). • Rate-of-rise triggers at 15°F (8.3°C) per minute for the NH- 100R(A). • 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. • Visible LEDs “blink” every time the unit is addressed. Mechanicals: • Sealed against back pressure. • SEMS screws for wiring of the separate base. • Designed for direct-surface or electrical-box mounting. • Plugs into separate base for ease of installation and main- tenance. • Separate base allows interchange of photoelectric, ioniza-tion and thermal sensors. Other system features: • Remote test feature from the panel. • Walk test with address display. • Low standby current. • 94-5V plastic flammability rating. Options: • Remote LED output connection to optional RA100Z remote LED annunciator. • Flanged surface mounting kit. Installation NH-100(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white fire-resistant plastic. The NH-100(A) Series plug-in intelligent thermal detectors are designed to commercial standards and offer an attractive appearance. Operation Each NH-100(A) Series detector uses one of 99 (FireWarden- 100-2, NSP-25) or 50 (FireWarden-50) possible addresses on a control panel SLC loop. It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimu- lates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The NH-100(A) Series offers features and performance that represent the latest in thermal detector technology. NH-100(A) in B210LP(A) Base B210-2251.jpg Page 2 of 2 — DN-6997:D • 5/17/13 NOTIFIER® and FireWarden® are registered trademarks of Honeywell International Inc. ©2013. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Spefications Size: 2.1" (5.3 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Installation temperature: –NH-100(A), NH-100R(A): –4°F to 100°F (–20°C to 38°C). –NH-100H(A): –4°F to 150°F (–20°C to 66°C). Humidity range: 10% to 93% relative humidity (noncon- densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 μA @ 24 VDC (one communication every five seconds with LED blink enabled). LED current: 6.5 mA @ 24 VDC. Mounting: B210LP(A) flanged base, included. See “Product Line Information: Intelligent Bases” if using a different base. Fixed-temperature setpoint: 135°F (57°C) for the NH-100 and NH-100R(A)(A); 190°F (88°C) for the NH-100H(A). Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Listings and Approvals Listings and approvals below apply to the NH-100(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S747. •ULC Listed: S747. •CSFM: 7270-0028:0234. •MEA: 387-02-E Vol. II. •FM approved. Product Line Information NOTE: “A” suffix indicates ULC Listed model. NH-100: Intelligent thermal sensor; 135° F (57° C); B210LP base included. NH-100A: Same as NH-100 but with ULC Listing; B210LPA base included. NH-100R: Same as NH-100 with rate-of-rise feature; B210LP base included. NH-100RA: Same as NH-100R but with ULC Listing; B210LPA base included. NH-100H: Intelligent fixed high-temperature thermal detector; 190° F (88° C); B210LP base included. NH-100HA: Same as NH-100H but with ULC Listing; B210LPA base included. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Standard European flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DN-6994). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. DN-6999:D • 01/20/2015 — Page 1 of 4 Monitor Modules NMM-100(A), NMM-100P(A), NZM-100(A), and NDM-100(A) for FireWarden Series Intelligent Addressable Devices DN-6999:D General Four different monitor modules are available for Notifier’s FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- tact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeed™ is a communication protocol that greatly increases the speed of communication between analog intel- ligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. NMM-100(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 – 99 on FireWarden-100- 2, 01 – 50 on FireWarden-50. • LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 µA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM-100P(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two-wire SLC loop. No additional power required. NMM-100(A) (Type H)6999cov.jpg Page 2 of 4 — DN-6999:D • 01/20/2015 • High noise (EMF/RFI) immunity. • Tinned, stripped leads for ease of wiring. • Direct-dial entry of address: 01 – 99 on FireWarden-100- 2, 01 – 50 on FireWarden-50. The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelli- gent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two- wire initiating device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-100P(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. NMM-100P(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). NMM-100P(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 µA, 1 communication every 5 seconds, 47k EOL; 600 µA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 µA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM-100(A) Interface Module • Supports compatible two-wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry entry of address:, 01 – 99 on FireWarden- 100-2, 01 – 50 on FireWarden-50. • LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intel- ligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 300 µA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box.6720m101.wmf DN-6999:D • 01/20/2015 — Page 3 of 4 NDM-100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 µA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 µA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address “26”, then it will automati- cally assign itself to addresses “26” and “27”. NOTE: “Ones” addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S635 •ULC: S635 • FM Approved •CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100) •MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100) Product Line Information NOTE: “A” suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-100P(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. !CAUTION: Avoid duplicating addresses on the system. Page 4 of 4 — DN-6999:D • 01/20/2015 Notifier® and FireWarden® are registered trademarks and LiteSpeed™ and FireWatch™ are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com DN-7001:D • 4/13/2012 — Page 1 of 2 NOT-BG12LX Addressable Manual Pull Station Intelligent/Addressable Devices DN-7001:D • A1-380 The NOT-BG12LX Addressable Manual Pull Station 6643cov1.jpgGeneral The Notifier NOT-BG12LX is a state-of-the-art, dual-action(i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide-lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonatematerial with a textured finish. Specifications •Shipping Weight: 9.6 oz. (272.15 g) •Normal operating voltage: 24 VDC. •Maximum SLC loop voltage: 28.0 VDC. •Maximum SLC standby current: 375 μA. •Maximum SLC alarm current: 5 mA. •Temperature Range: 32°F to 120°F (0°C to 49°C) •Relative Humidity: 10% to 93% (noncondensing) •For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTI- VATED” (in bright yellow) appears at the top of the handle,while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 99 on NFW2-100/NFW2-100C, 1 – 50 for NFW-50/NFW- 50C). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shallappear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flushmounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed Page 2 of 2 — DN-7001:D • 4/13/2012 NOTIFIER® is a registered trademark of Honeywell International Inc.©2012 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provideaddress setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro-cess. Consult factory for latest listing status. •UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). •MEA: 67-02-E Vol. IV. •CSFM: 7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. dn-60528:a • 03/12/10 — Page 1 of 2 ND-200 Intelligent Non-Relay Photoelectric Duct Smoke Detector for FireWarden Series Panels Intelligent Devices dn-60528:a General The Notifier ND-200 intelligent non-relay photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. The unit senses smoke in the most challenging conditions, oper- ating in airflow speeds of 100 to 4,000 feet per minute, tempera- tures of -4 degrees F to 158 degrees F, and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sen- sor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. Features • Photoelectric, integrated low-flow technology • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s) • Versatile mounting options: square or rectangular configura- tion • Broad ranges for operating temperature (-4F to 158F) and humidity (0% to 95% non-condensing) • Patented sampling tube installs from front or back of the detector with no tools required • Cover tamper signal • Increased wiring space with a newly added 3/4” conduit knockout • Available space within housing to accommodate mounting of a relay module • Easily accessible code wheels on NP-100R sensor head (included) • Clear cover for convenient visual inspection • Remote testing capability • Requires com line power only • Accommodates the installation of an addressable relay mod- ule, sold separately, (NC-100R) for applications requiring a Form-C relay Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm)Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width;2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Operating Temperature Range: -4 degrees F to 158 degrees F (-20 degrees C to 70 degrees C) Storage Temperature Range: -22 degrees F to 158 degrees F (-30 degrees C to 70 degrees C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s) Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detec- tors, all duct smoke detectors accessories are UL listed. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA100Z 0mA 12 mA Max RTS151/ RTS151KEY 0mA 12mA Max intelligent innovairflex.jpg Page 2 of 2 — dn-60528:a • 03/12/10 ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.com Made in the U.S. A. Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. •UL/ULC Listed: S1115 •CSFM: 3240-0028:236 Product Line Information NOTE: “A suffix indicates ULC listed model. ND-200(A): Intelligent, non-relay, photoelectric, low flow duct smoke detector. Includes DNR-InnovairFlex duct detector hous- ing and NP-100R (Remote Test Capable) photo electric detec- tor. DNRW: Watertight, intelligent, non-relay, photoelectric, low flow duct smoke detector housing. NEMA-4. See DN-60429. NP-100R(A): Remote test capable addressable low-profile pho- toelectric smoke detector for FireWarden series panels. Included with the ND-200. Order seperately for ND-200 detec- tor replacement or for watertight applications using the DNRW. DST1(A): Metal sampling tube duct width up to 1 ft (0.3m) DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m) DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m) DST5(A): Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m) DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m) DH400OE-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21-00: End cap for metal sampling tubes RA100Z(A): Remote annunciator alarm LED RTS151(A): Remote test station RTS151KEY(A): Remote test station with key lock Important Note • For watertight applications use a DNRW duct detector hous- ing with a NP-100R. dn-60535:b1 • 1/27/12 — Page 1 of 4 Duct Smoke Detector Accessories for Notifier/System Sensor Products Miscellaneous dn-60535:b1 60535cov.wmfGeneral Duct smoke detector accessories add functionality to the duct smoke system by allowing quick, convenient inspections at eye level and effective audible and visual notification options. All System Sensor duct smoke detectors and accessories are UL listed. Specifications APA151 PIEZO ANNUNCIATOR The APA151 piezo annunciator, which replaces the APA451with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicatepower status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a systemcontrol panel, to comply with NFPA 90A. MHR/MHW MINI-HORNS The MHR and MHW SpectrAlert® Advance mini-horns featuretemporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. APA151 Piezo Annunciator Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 32°F to 120°F (0°C to 49°C) Relative Humidity 10 to 93%, non-condensing Wire Gauge 12 to 18 AWG Dimensions 4.6” H x 2.9” W x .45” D APA151.wmfMHR.wmf, MHW.wmfMHR/MHW SpectrAlert Advance Mini-Horns Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33 VDC (9 to 33 VDC with Sync-Circuit™ Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max. at 8 to 17.5 Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12 to 18 AWG Dimensions 4.6”H x 2.9”W x 0.45”D Page 2 of 4 — dn-60535:b1 • 1/27/12 RA100Z/RA100ZA REMOTE ANNUNCIATORS The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LEDprovides visual indication of an alarm condition. RTS151/RTS151KEY REMOTE TEST STATIONS The RTS151 and RTS151KEY remote test stations are auto- matic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151KEY test station features a multi-colored LED that alter- nates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. RTS2/RTS-AOS MULTI-SIGNALLING ACCESSORIES The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. RA100Z/RA100ZA Remote Annunciator Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 10 mA Dimensions 4.6”H x 2.8”W x 1.3”D RTS151 Remote Test Station Power Requirements Alarm LED 2.8 to 32 VDC, 10 mA max. Total Current: 95 mA max. Test Switch 10 VA @ 32 VDC Reset Switch 10 VA @ 32 VDC Alarm Response Time 40 seconds max. Temperature Range 14°F to 140°F (-10°C to 60°C) Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Dimensions 4.8”H x 2.9W x 1.4”D RA100Z.wmfRTS151.wmf, RTS151KEY.wmfRTS151KEY Remote Test Station with Key Power Requirements Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (RED): 2.8 to 32 VDC, 12 mA max. Alarm Response Time 40 seconds max. Temperature Range 14°F to 140°F (-10°C to 60°C) Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Dimensions 4.6”H x 2.75W x 1.8”D RTS2 and RTS-AOS Multi-signaling Accessory Voltage 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without Strobe: 30 mA max. Alarm with Strobe: 55 mA max. Sounder 85 dBA at 10 ft. Temperature Range 14°F to 140°F (-10°C to 60°C) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8”W x 5.3”H x 1.6”D RTS-AOS.wmf, AOS.wmf dn-60535:b1 • 1/27/12 — Page 3 of 4 Product Line Information APA151: Piezo Annunciator MHR: Mini-Horn, Red MHW: Mini-Horn, White RA100Z/RA100ZA: Remote Annunciator RTS151: Remote Test Station RTS151KEY: Remote Test Station with Key RTS2: Multi-signaling Accessory AOS: Add-On Strobe RTS2-AOS: Multi-Signaling Accessory Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49ºC/32 – 120ºF and at a relative humidity 93% ± 2% RH (noncondensing) at 32ºC ± 2ºC (90ºF ± 3ºF). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27ºC/60 – 80ºF. Agency Listings and Approvals The listings and approvals below apply to the basic products. In some cases, certain modules may not be listed by certainapproval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S4011 (APA 151, MHR, MHW), S2522 (RTS2, RA100Z, RTS151, RTS151KEY, RTS2-AOS) • FM Approved • CSFM: 7135-1653:0212 Page 4 of 4 — dn-60535:b1 • 1/27/12 FlashScan®, NOTIFIER® and System Sensor® are registered trademarksof Honeywell International Inc.©2012 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. DN-6927:A2 • 5/17/13 — Page 1 of 2 FCPS-24S6(C/E) & FCPS- 24S8(C/E) 6- & 8-Amp 24-Volt Remote Power Supplies Power Supplies DN-6927:A2 General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) areremote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be config-ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries.FCPS-24S6C & FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features • UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex “Commander2” appliances. • Operates as a “sync-follower” or as a “sync-generator” (default). See note on page 2. • Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma-nently “ON” (stand-alone mode). • Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous output in stand-alone mode (UL 1481). • Compatible with coded inputs; signals passed through. • Optional power-supervision relay (EOLR-1). • In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. • Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and othersystem peripherals requiring regulated/filtered power. • Power-limiting technology meets UL power-limiting require- ments. • Form-C normally-closed trouble relay. • Fully supervised power supply, battery, and NACs. • Selectable earth fault detection. • AC trouble report selectable for immediate 2-hour delay. • Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated NAC power). • Requires input trigger voltage of 9 - 32 VDC. • Self-contained in compact, locking cabinet - 15”H x 14.5”W x 2.75”D (cm: 38.1H x 36.83W x 6.985D). • Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. • Battery charger may be disabled via DIP switch for applica-tions requiring larger batteries. • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: • FCPS-24S6C/-24S8C: 120 VAC, 60 Hz, 3.2A maximum. • FCPS-24S6E/-24S8E: 240 VAC, 50 Hz, 1.6A maximum. • Wire Size: minimum #14 AWG (2.0mm 2) with 600 V insula- tion. Control Input Circuit: •Trigger Input Voltage: 9 to 32 VDC. •Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: • +24 VDC filtered, regulated. • 3.0 A maximum for any one circuit. • Total continuous current for all outputs (stand-alone mode): –FCPS-24S6: 4.0 A maximum. –FCPS-24S8: 6.0 A maximum. • Total short-term current for all outputs (NAC expander mode): –FCPS-24S6: 6.0 A maximum. –FCPS-24S8: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: • Supports lead-acid batteries only. Page 2 of 2 — DN-6927:A2 • 5/17/13 System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.com Made in the U.S. A. • Float-charge voltage: 27.6 VDC. • Maximum current charge: 1.5 A. • Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliancecircuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate theFCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expandingsystem architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flashtiming of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. Wheninstalled at the end of a NAC wire run, the FCPS-24S6/-24S8 can track (i.e. “follow”) the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a “sync follower,” the FCPS’s NAC outputs track thestrobe synchronization pulses present at the FCPS’s sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-24S8 are configured (via DIP switch settings) as a “sync generator,” the FCPS’s sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS’s NAC outputs. In “sync generator” mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24S6 and FCPS-24S8 comply with the following standards: •NFPA 72 National Fire Alarm Code. •UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). •UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified inthis document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S635, S674 •ULC Listed: S635 (FCPS-24S6C & FCPS-24S8C) •CSFM Approved: 7315-0028:225 •MEA: 299-02-E • FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure(15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-listed. FCPS-24S6R: Same as FCPS-24S6 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure(15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-24S8 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wiresmoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). DN-6933:D • 02/28/2013 — Page 1 of 2 BAT Series Batteries Sealed Lead-Acid Power Supplies DN-6933:D • E-205 General BAT Series Batteries are Power-Sonic brand batteries. BATSeries (or Power-Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features • Provide secondary power for control panels. • Sealed and maintenance-free. • Overcharge protected. • Easy handling with leak-proof construction. • Ruggedly constructed, high-impact case (ABS). • Long service life. • Compact design. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batter- ies. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consultfactory for latest listing status. •UL Recognized Components: MH20845 (Power-Sonic). Ordering Information BAT-1250-BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH). BAT-1270-BP: 5-unit bulk pack of BAT-1270 (12 V 7 AH). BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH). BAT-12180-BP: 2-unit bulk pack of BAT-12180 (12 V 18 AH). BAT-12260-BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH). BAT-12550: single battery (12 V 55 AH). BAT-121000: single battery (12 V 100 AH). Part Number Reference & Specifications 6933cov.jpg Part Number Power-Sonic Part Number Battery Description DIMENSIONS Nominal Voltage V Nominal Capacity @ 20 hr. rate A.H. Width Depth Height Height over terminal Weight in. mm in. mm in. mm in. mm lb. kg. BAT-1250 PS-1250 12 5 sealed 3.54 90 2.76 70 3.98 101 4.21 107 3.50 1.59 BAT-1270 PS-1270 12 7 sealed 5.95 151 2.56 65 3.7 94 3.86 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 5.95 151 3.86 98 3.7 94 3.94 100 7.92 3.59 BAT-12180 PS-12180 12 18 sealed 7.13 181 3.00 76 6.59 167 6.59 167 12.6 5.72 BAT-12260 PS-12260 12 26 sealed 6.5 167 6.97 177 4.92 125 4.92 125 17 7.71 BAT-12550 PS-12550 12 55 sealed 9.04 230 5.45 138 8.15 207 8.98 228 36 16.33 BAT-121000 PS-121000 12 100 sealed 12 305 6.6 168 8.15 207 8.98 228 68 30.84 Page 2 of 2 — DN-6933:D • 02/28/2013 NOTIFIER® is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer.©2013 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com )%( oitaR yticapaCTemperature (°C) Discharge TimeegatloV lanimreTDischarge Characteristic Curves at 20°C (68°F) Effect of Temperature on Capacity 6933grf1.ai6933grf2.ai6933grf3.aiPS-121000 Shelf-Life and Storage aCpcaiyteteRntnoitaRoi%()Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF) 20oC (68oF) 5oC (41oF) Chargingisnot necessary unless 100% of capacity is required. Chargingbefore use is necessary to help recoverfull capacity. Chargemayfailto restore full capacity. Do not let batteries reach this state. 13.0 12.0 11.0 10.0 9.0 8.0 14.0 lanimreT)V( egatloVAmbient Temperature 20 oC(68oF) 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 Discharge Time Final Voltage min h 5.01020 50 100 200 6933grf4.aiPS-121000 Discharge Characteristics DN-7087:C1 • 11/9/11 — Page 1 of 4 SpectrAlert® Advance Selectable Output Notification Appliances Audio/Visual Devices DN-7087:C1 General System Sensor® SpectrAlert® Advance selectable-outputhorns, strobes and horn/strobes are rich with features guaran- teed to cut installation times and maximize profits. The Spec- trAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installa- tion of individual devices, and eleven field-selectable candela settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four-inch square, four- inch octagon, or double-gang junction box. The two-wiremounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the product’s tabs in the mounting plate’s grooves. The device will rotate into position, locking the prod- uct’s pins into the mounting plate’s terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: • 12 or 24 volts. • 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 can- dela by way of a rear-mounted slide switch and front view- ing window. • Horn tones and volume by way of a rotary switch. • The SpectrAlert Advance series includes outdoor notifica- tion appliances. Outdoor strobes and horn/strobes (two- wire and four-wire) are available for wall or ceiling. Outdoorhorns are available for wall only. All System Sensor outdoor products are rated between –40°F and 151°F (–40°C and 66°C) in wet or dry applications. Models available: • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wirehorn/strobe. • Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4- wire horn/strobe. • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. Features • Plug-in design. • Same mounting plate for wall- and ceiling-mount units. • Shorting spring on mounting plate for continuity check before installation. • Captive mounting screw. • Tamper-resistance capability. • Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75 candela. • Outdoor wall and ceiling products. • Outdoor products rated from –40°F and 151°F (–40°C and 66°C). • Outdoor products rainproof per UL50 (NEMA 3R) and weatherproof per NEMA 4X, IP56 • Minimal intrusion into the backbox. • Horn rated at 88+ dbA at 16 volts. • Rotary switch for tone selection. • Three horn volume settings. • Electrically compatible with existing SpectrAlert products. Engineering Specifications SpectrAlert Advance horns, strobes, and horn/strobes shallmount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0" (10.16 cm) octagonal backbox, or a double- gang backbox. Two-wire products shall also mount to a single- gang 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- trAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal12 or 24 volts. When used with the Sync•Circuit Module, 12- volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F (0°C and 49°C) from a regulated DC, or full-wave-recti- fied, unfiltered power supply. Strobes and horn/strobes shallhave field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Indoor Ceiling Horn/Strobe Outdoor Ceiling Strobe Indoor Wall Horn/Strobe Indoor Ceiling Strobe Indoor WallHorn Outdoor WallStrobe7087pho1.jpg7087pho4.jpg7087pho3.jpg7087pho2.jpg7087pho5.jpg7087pho6.jpg Page 2 of 4 — DN-7087:C1 • 11/9/11 STROBE The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-sig- naling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe’s entire operating volt- age range. The strobe light shall consist of a xenon flash tubeand associated lens/reflector system. HORN/STROBE COMBINATION The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector sys-tem. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non-Temporal (continuous) pattern. These options are set by a multiple posi- tion switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. OUTDOOR PRODUCTS SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between –40°F and 151°F (–40°C and 66°C). The productsshall be listed for use with a System Sensor outdoor/weather- proof backbox with half-inch and three-fourths-inch conduit entries. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit MDL3R or MDL3W listed to UL 464 and shall be approved for fire protec- tive service. The module shall synchronize SpectrAlert strobesat 1 Hz and horns at Temporal 3. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) back- box. The module shall also control two Style Y (class B) cir- cuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more syn- chronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Specifications •Standard operating temperature: 32°F to 120°F (0°C to 49°C). •K Series operating temperature: –40°F to 151°F (–40°C to 66°C). •Humidity range: 10% to 93% non-condensing (indoor products). •Strobe flash rate: 1 flash per second. •Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. •Operating voltage range: 8 V to 17.5 V (12 V nominal); or16 V to 33 V (24 V nominal). NOTE: P, S, PC, and SC prod- ucts will operate at 12 V nominal only for 15 cd and 15/75 cd. •Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mm²). •Ceiling-mount dimensions (including lens): 6.8" diame- ter x 2.5" deep (17.3 cm diameter x 6.4 cm deep). •Wall-mount dimensions (including lens): 5.6" H x 4.7" Wx 2.5" D (14.2 cm H x 11.9 cm W x 6.4 cm D). •Horn dimensions: 5.6" H x 4.7" W x 1.3" D (14.2 cm H x11.9 cm W x 3.3 cm D). Agency Listings and Approvals The listings and approvals below apply to SpectrAlert Advance Selectable Output Notification Devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus. •UL Listed: S4011 (HR__, HW__, P2__, P4__, PC2__, PC4__ models); S5512 (models SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, SRHK, SRK). •ULC Listed: S4011 (HRA, HRKA); S5512 (typically “A” models, with exception of outdoor strobes). See Canadian data sheet for listings and specifications. •FM approved •MEA: 452-05-E •CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); 7300-1653:0188 (P2_, P4_, PC2_, PC4_ modules); 7135-1653:0189 (HR, HRK, HW); 7300- 1653:0187 (SCRHK, SCRK, SRHK, SRK). Strobe Current Draw, UL Maximum (mA RMS) Candela 8 – 17.5 V 16 – 33 V DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA N/A 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Horn Current Draw, UL Maximum (mA RMS) Sound Pattern dB 8 – 17.5 V 16 – 33 V DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DN-7087:C1 • 11/9/11 — Page 3 of 4 Two-Wire Horn/Strobe, STANDARD Candela Range (15 – 115 cd), UL Maximum Current Draw (mA RMS) Input, Sound Pattern, dB Level 8 – 17.5 V 16 – 33 V 15 15/75 15 15/75 30 75 95 110 115 DC Input, Temporal, High 137 147 79 90 107 176 194 212 218 DC Input, Temporal, Medium 132 144 69 80 97 157 182 201 210 DC Input, Temporal, Low 132 143 66 77 93 154 179 198 207 DC Input, Non-temporal, High 141 152 91 100 116 176 201 221 229 DC Input, Non-temporal, Medium 133 145 75 85 102 163 187 207 216 DC Input, Non-temporal, Low 131 144 68 79 96 156 182 201 210 FWR Input, Temporal, High 136 155 88 97 112 168 190 210 218 FWR Input, Temporal, Medium 129 152 78 88 103 160 184 202 206 FWR Input, Temporal, Low 129 151 76 86 101 160 184 194 201 FWR Input, Non-temporal, High 142 161 103 112 126 181 203 221 229 FWR Input, Non-temporal, Medium 134 155 85 95 110 166 189 208 216 FWR Input, Non-temporal, Low 132 154 80 90 105 161 184 202 211 Two-Wire Horn/Strobe, HIGH Candela Range (135 – 185 cd), UL Maximum Current Draw (mA RMS) DC Input 16 – 33 V FWR Input 16 – 33 V 135 150 177 185 135 150 177 185 DC, Temporal, High 245 259 290 297 FWR, Temporal, High 215 231 258 265 DC, Temporal, Medium 235 253 288 297 FWR, Temporal, Medium 209 224 250 258 DC, Temporal, Low 232 251 282 292 FWR, Temporal, Low 207 221 248 256 DC, Non-temporal, High 255 270 303 309 FWR, Non-temporal, High 233 248 275 281 DC, Non-temporal, Medium 242 259 293 299 FWR, Non-temporal, Medium 219 232 262 267 DC, Non-temporal, Low 238 254 291 295 FWR, Non-temporal, Low 214 229 256 262 7087dim12009.tif 2.5 2.5” 4.7” 5.6” 6.8” Horn and Horn/Strobe Output (dBA) SwitchPosition Sound Pattern dB 8 – 17.5 V 16 – 33 V DC FWR DC FWR 1 Temporal High 78 78 84 84 2 Temporal Medium 74 74 80 80 3 Temporal Low 71 73 76 76 4 Non-temporal High 82 82 88 88 5 Non-temporal Medium 78 78 85 85 6 Non-temporal Low 75 75 81 81 7* Coded High 82 82 88 88 8* Coded Medium 78 78 85 85 9* Coded Low 75 75 81 81 *NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. Horn and Horn/Strobe Rotary Switch Setting Setting Repetition Rate dB Level 1 Temporal horn High 2 Temporal horn Medium 3 Temporal horn Low 4 Normal horn High 5 Normal horn Medium 6 Normal horn Low 7* Externally coded High 8* Externally coded Medium 9* Externally coded Low *NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. Page 4 of 4 — DN-7087:C1 • 11/9/11 Sync•Circuit™ is a trademark and NOTIFIER® and SpectrAlert® areregistered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire horn/strobe, standard cd, red.PC2R 2-wire horn/strobe, standard cd, red. P2RH 2-wire horn/strobe, high cd, red.PC2RH 2-wire horn/strobe, high cd, red. P2RK 2-wire horn/strobe, standard cd, red, outdoor.PC2RK 2-wire horn/strobe, standard cd, red, outdoor. P2RHK 2-wire horn/strobe, high cd, red, outdoor.PC2RHK 2-wire horn/strobe, high cd, red, outdoor. P2W 2-wire horn/strobe, standard cd, white.PC2W 2-wire horn/strobe, standard cd, white. P2WH 2-wire horn/strobe, high cd, white.PC2WH 2-wire horn/strobe, high cd, white. P4R 4-wire horn/strobe, standard cd, red.PC4R 4-wire horn/strobe, standard cd, red. P4RH 4-wire horn/strobe, high cd, red.PC4RH 4-wire horn/strobe, high cd, red. P4RK 4-wire horn/strobe, standard cd, red, outdoor.PC4RK 4-wire horn/strobe, standard cd, red, outdoor. P4RHK 4-wire horn/strobe, high cd, red, outdoor.PC4RHK 4-wire horn/strobe, high cd, red, outdoor. P4W 4-wire horn/strobe, standard cd, white.PC4W 4-wire horn/strobe, standard cd, white. P4WH 4-wire horn/strobe, high cd, white.PC4WH 4-wire horn/strobe, high cd, white. WALL STROBES CEILING STROBES SR Strobe, standard cd, red.SCR Strobe, standard cd, red. SRH Strobe, high cd, red.SCRH Strobe, high cd, red. SRK Strobe, standard cd, red, outdoor.SCRK Strobe, standard cd, red, outdoor. SRHK Strobe, high cd, red, outdoor.SCRHK Strobe, high cd, red, outdoor. SW Strobe, standard cd, white.SCW Strobe, standard cd, white. SWH Strobe, high cd, white.SCWH Strobe, high cd, white. ACCESSORIES HORNS BBS-2A Backbox skirt, wall, red.HR Horn, red. BBSW-2A Backbox skirt, wall, white.HRK Horn, red, outdoor. BBSC-2A Backbox skirt, ceiling, red.HW Horn, white. BBSCW-2A Backbox skirt, ceiling, white. ACCESSORIES, continued SA-WBB Weatherproof backbox, wall.TR-HS Trim Ring, wall, red, package of 5 SA-WBBC Weatherproof backbox, ceiling. TRW-HS Trim Ring, wall, white, package of 5 WTP Weatherproof, flush mount plate, red TRC-HS Trim Ring, ceiling, red, package of 5 WTPW Weatherproof, flush mount plate, white TRCW-HS Trim Ring, ceiling, white, package of 5 NOTE: “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. NOTE: For strobes and horn/strobes, add suffix “F” for French or “B” for Bilingual. NOTE: All outdoor models (“K(A)” suffix) include a plastic weatherproof backbox. NOTE: Add “-R” to models for weatherproof replacement device (no back box included). Only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. NOTE: Add “P” to model for plain housing. (No “FIRE” marking on cover.) dn-60383:A2 • 06/17/10 — Page 1 of 2 NC-100R(A) Relay Module for FireWarden Series Panels Addressable dn-60383:A2 General The NC-100R(A) Addressable Relay Module provides NOTI-FIER’s FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features •Built-in type identification automatically identifies these devices to the control panel. •Internal circuitry and relay powered directly by two-wire SLC loop. •Integral LED “blinks” green each time a communication is received from the control panel and turns on in steady when activated. •High noise immunity (EMF/RFI). •Wide viewing angle of LED. •SEMS screws with clamping plates for wiring ease. •Direct Decade entry of address: 01 – 99 with the FireWar- den-100-2(C) and 01 – 50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to resetfour-wire smoke detector power. Construction •The face plate is made of off-white heat-resistant plastic. •Controls include two rotary switches for direct-dial entry of address setting. •The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-100R(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 μA direct poll (CLIP mode), 255 μA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (L/R=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A NC-100R(A)60379cov.jpg Page 2 of 2 — dn-60383:A2 • 06/17/10 NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.com Made in the U.S. A. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL/ULC Listed: S635. •CSFM approved: file 7300-0028:230. •FM approved. •MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document I56-2593-001 and refer to the SLC Wiring Manual, document 52304. DN-6755:A • 08/19/14 — Page 1 of 2 PAM-1, PAM-2, and PAM-4 Multi-Voltage Relay Modules Relays DN-6755:A General Air Products & Controls, Inc. PAM-1, PAM-2, and PAM-4 Multi-Voltage Relay Modules are encapsulated multi-voltage devices. The PAM-1 relay provides 10.0 Amp Form-C contacts and may be energized by one of three input voltages: 24 VAC, 24 VDC, or 115 VAC. The PAM-2 relay provides 7.0 Amp Form-C contacts and may be energized by one of two input voltages: 12 VDC or 24 VDC. The PAM-4 relay provides 10.0 Amp Form-C contacts and may be energized by a wide voltage range from 9 VDC to 40 VDC. A red LED is provided on both models. When illuminated, it indicates the relay coil is energized. Either model may be mounted by using the double-sided adhe- sive tape, the self-drilling screw, or by placing loosely in a backbox. PAM-1, PAM-2, and PAM-4 Relay Modules are ideal for appli- cations where remote relays are required for control or status feedback. They are suitable for use with HVAC, temperature control, fire alarm, security, energy management, and lighting control systems. Specifications Power requirements: • PAM-1: 0.015 Amps per position @ 24 VDC, 24 VAC, 115VAC. • PAM-2: 0.015 Amps per position @12 VDC or 24 VDC. • PAM-4: 0.015 Amps per position @ 24 VDC or 12 VDC. Relay: UL-recognized SPDT. Contact Rating: • PAM-1: 10.0 A @ 115 VAC, 7.0 A @ 28 VDC, 250uA @ 5 VDC. • PAM-2: 7.0 A @ 115 VAC, 7.0 A @ 28 VDC, 250uA @ 5 VDC. • PAM-4: 10.0 A @ 120 VAC, 7.0 A @ 24 VDC, 250uA @ 5 VDC. Ambient Temperature Range: -58°F to 185°F (-50°C to 85°C). Dimensions: 1.5” (3.81 cm) high x 1.0” (2.54 cm) wide x 0.875” (2.223 cm) deep, with 12” (30.48 cm) wire leads @ 18 AWG (0.75 mm2). Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing maybe in process. Consult factory for latest listing status. •UL Listed: S3403 •MEA: 73-92-E, Volume XXI •CSFM: 7300-1004:101 Product Line Information PAM-1: Single SPDT relay with LED, double-sided adhesive tape, mounting screw, 12” (30.48 cm) leads, and six wire nuts. PAM-2: Single SPDT relay with LED, double-sided adhesive tape, mounting screw, 12” (30.48 cm) leads, and six wire nuts. PAM-4: Single SPDT relay with LED, double-sided adhesive tape, mounting screw, 12” (30.48 cm) leads, and six wire nuts. PAM-1 6755pho1.jpg Page 2 of 2 — DN-6755:A • 08/19/14 ©2014 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Wiring Diagrams PAM-1 PAM-2 PAM-4