A16-0014_VS2 system_1456158960.pdf
� �_.,� .iii�� sir;Ak i.. TM '1:1; IGILAN -1.71 AR!, Fire & Life Safety g - rttl S LI e S . fety System 102 I telligent „,,, „, � � U ps .. •, 8'3000 S3000 s5 16f7,;014, FDNY APPROVAL 16020 Ove iew Features The Vigil.nt VS2 intellige t life safety system offers the speed of • Comes standard with one loop (expandable to two)that high-en• intelligent processing in a configuration that delivers an supports up to 250(expandable to 500)intelligent devices: uncomp icated solution for small to mid-sized applications.Wit-) each VS2 loop supports up to 125 detectors and up to 125 intelligen detection, elec ironic addressing, automatic device modules. mappin., optional Ethern-t®connectivity, and a full line of easily- • Four Class B NACs or two Class A NACs. configured option cards .nd modules,this quick-to-inslall system offers ve satility that ben- its building owners and contractors • Form C contacts for alarm and trouble, Form A for supervisory alike. • Electronic addressing with automatic device mapping The VS•provides one Class A or Class B analog device loop that • Optional Ethernet port for diagnostics, programming and a supports up to 250 devic- addresses. A second 250-point loop variety of system reports may be .dded to the VS.to expand total system capacity to up • Two programmable switches with LEDs and custom labeling to 500 device addresses. The panel includes four NACs that may • Supports fire suppression routines with a dedicated intelligent be wired for either Class or Class B operation. releasing module This life safety system fea ures an attractive contemporary design • that fits ith any decor. It• gently curved doorfront offers a distinc Supports Genesis horn silence over two wires and UL tive flair ith available red or silver finishes. Controls are discreetly 1971 compliant strobe synchronization inset beh nd a striking blas k bezel. • Supports up to eight serial annunciators, (LCD, LED-only, and The VS2 supports a wide ange of accessories and related equip graphic interface). ment, inc uding: • 1,000 event panel history log • Intel]gent modules, d-tectors, and bases • Can use existing wiring for most retrofit applications • R-Series remote ann nciators • Supports V-Series single and multisensor detectors • option cards that expend system capacity and exteid system • Upload/download remotely or locally capabilities. • Two-level maintenance alert reporting • Integ ated Carbon Monoxide gas sensing with V-PCOS de- teeters including disti ct audible signaling • Pre-alarm and alarm verification by point • Adjustable detector sensitivity • 4 x 20 character backlit LCD display • Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Page 1 of 1* M85005-0130 issue 6 Mplicalion Operation The VS2 life safety system is an easy-to-use intelligent solution for The front panel provides an easy-to-use operator's interface, as small to mid sized buildings.Analog technology delivers the benefits well as all the necessary controls for front panel programming. of quick an. uncomplicated system installation,while a clean and A large back-lit 80-character LCD displays system status, event easy-to-ope atate user interface makes panel operation and system details, and programming prompts. Large tactile control buttons maintenanct quick and intuitive. are easy to see in low light conditions, and bright multi-color LEDs offer at-a-glance status indication. The smart+ hoice LCD System Electronic addressing eliminates the tedium of setting dipswitches, display LEDs and automa is device mapping ensures that each device resides %S on the syste at its correct location. Meanwhile, innovative pro- Banne-� o a r ® gramming al ows the designer to customize the system to pre— cisely suit th- needs of the building owner. �� r 9 cable ©. _ _ re Versatility right inQ �w J J Two fully-programmable front panel switch/LED combinations pro- C I vide an add:d measure of simplicity.Their slide-in labels take the [ ) 1=1-c- 3 DEE mystery out of custom applications, and present a clean finished CO R `' 6""° � ()won i appearance. �oFr�� 7'''"s 8 W 9a MONROH a POV s, I..=Iof croCE ® �' Perfect for etrofits System The VS2 is particularly well-suited to retrofit applications.All LEDs control buttons connections :re made over standard wiring—no shielded cable required. Thi• means that in most situations existing wiring can be used to upgrade a legacy control panel to V-Series technology Control buttons without the e pense or disruption of rewiring the entire building. Button Description Reset Initiates a system reset. Signals wit a difference ACK/Panel Silences the panel and remote annunciators during VS2 NACs ar- configurable to fully support the advanced signaling Silence an active trouble,supervisory,or alarm event and capabilities o'Edwards Genesis and Enhanced Integrity noti-ica acknowledges new event activations. Signal Silence Alarm mode:Silences active notification appliances. tion appliances.These devices offer precision synchronizaticn of strobes to U 1971 standards For Genesis devices, enabling this Pressing Signal Silence a second time turns NACs back feature allow connected horns to be silenced while strobes on on. the same two wire circuit cont nue to flash until the panel is reset. Drill Initiates a drill confirmation.Pressing drill a second time turns off the drill function. Remote Dialer:Disables or enables dialer. Clear-cut re ote annunciation Disconnect Dialer set to modem only:Disables or enables the Remote annu ciation is a strong suit of the VS2. Up to eight an- common alarm relay. nunciators ca be installed on a single system. Compatible annun- Left arrow Display mode:Moves the cursor to the left. ciators includa a range of LED and LCD models that provide zone Menu mode:Toggles between programming or point annu ciation, as well es common control capabilities. selections. The VS2 also .upports graphic annunciation with optional RA Right arrow Display mode:Moves the cursor to the right. Menu mode:Retrieves a programming option's sub Graphic Annu icator interface modules. Each interface provides menu and toggles between a programming option's common cont ol, indicators, and 32 LEDS. Consult the Ordering selections. Information se tion for details. Up arrow Display mode:Advances to the previous event. Menu mode:Moves the cursor up. complete lie of accessories Down arrow Display mode:Advances to the next event. AThe VS2 life safety system is sLpported by a complete line of Menu mode:Moves the cursor down. intelligent date tors, modules and related equipment. Consult the Enter Display mode:Displays selected event details. Ordering Infor ation section for details. Menu mode:Retrieves a programming option's sub menu or jumps to the Save function in the menu, Entry mode:Enters the selected data into the system. Cancel Display mode:Exits the detailed information display. Menu mode:Exits the current menu level. Entry mode:Clears the current entry. Menu Display mode: Enters the menu mode Menu mode: Exits menu mode Space Enters a space,such as a space between words. Alphanumeric Entry mode:Pressing a button once enters the number keypad on the button.Pressing the button twice enters the secondary value. Programmable These buttons can be programmed to control outputs, buttons disable devices or unlatch system outputs.The buttons can be labeled with a slip-in insert. Page 2 of ID 5005- 0130 Issue 6 System LEDs Panel Operation Options LED Description Language English or French Alarm Red LED. On steady when there is an active Marketplace U.S.or Canada alarm. AC fail delay Off:Off-premise notification of an AC power failure Trouble Yellow LED. Flashes when there is a fault on a is immediate. monitored circuit or system component, or when 1 to 15 hours:Delays the off premise notification of a circuit is disabled. an AC power failure by the time period selected. Supv Yellow LED. On steady when there is an active Zone resound On:NACs resound each time a device in the zone supervisory LED event. goes into alarm even if they were silenced Off: Inhibits the NACs from turning on again(after AC Power Green LED. On when the panel has AC power. they were silenced)when a second device in the Disable Yellow LED. Double-flashes when there is a dis- zone goes into alarm. abled circuit or alarm relay. Reset inhibit after Off:Panel reset is operational immediately. Ground Yellow LED.On steady during an active ground NAC5 turn on 1 minute:Panel reset is inhibited for one minute. Fault fault. Auto signal Off:Allows immediate silencing of signals from an silence offnormal condition using the Signal Silence button Test Yellow LED. Flashes when performing an audible walk test.Steady indicates a silent test. 5 to 30 minutes:Delays the silencing of signals from an off-normal condition by disabling the Signal Monitor Yellow LED. On steady when there is an active Silence button for the time period selected. monitor event. Day start Start time for daytime sensitivity Service Yellow LED. Indicates that detector needs servic- Night start Start time for nighttime sensitivity Detector ing. Date MM/DD/YYYY, DD/MM/YYYY Signal Yellow LED. On steady indicates that NAC cir- Sounder Base Six configuration settings Silence cuits are turned off but the panel is still in alarm. Mapping Disabled:Device mapping is not available Remote Yellow LED. On steady indicates that the diale Enabled:Device mapping is available Disconnect is disabled or that the alarm relay is enabled o LCD banner Banner text for line one and line two. Each line is disabled when the dialer is set to modem only. capable of up to 20 characters. Drill Yellow LED. Indicates that the panel is in drill. Event notification Zone:When a device is a member of a zone,only Reset Yellow LED. Indicates that the panel is resetting. the zone information is sent to the LCD display, LEDs,printer,and dialer. Panel Yellow LED. Indicates that the panel has been Zone/device:Zone information is sent to the LCD Silence silenced during an active trouble, supervisory, or display and LEDs.Device information is sent to the alarm event and indicates that new event active- printer and dialer. tions have been acknowledged. Device:Only device information is reported. User keys Yellow LED. Programmable. Programming Dimensions V-Series panels are simple to set up, quick to program, and easy to maintain.The auto programming feature quickly gets the pa-el Surface mounting holes Backbox with Backbox with door and operational using factory default settings. Basic zone and point l.--D2-.11.--D3-01door attached trim ring attached settings can be programmed easily through the front panel inter- 0°' '00 0 °O • •-57-01 face, so the system is up and running in no time. I' o ° ' ® O t 0 0 For more advanced system configuration and correlaticn groups t o 0 programming, V-Series panels interface to a PC running compat- Jz 0 0 0.ible VS-CU software.This option offers full system conf guration 1 D1 , o D'E D8 in the familiar Windows®operating environment. Connection is ® ® o ® 0 0 typically made to a laptop through the panel's optional RS-2324 communications port, which can also be used to connect a sys- Surface mounting holes ° . 5 5 tem printer. Among the many innovations of the VS2 control panel is the 14 .,_____D6—.D5 I.D9.1 -.)Ds.1 optional network card. This module provides a standard 10/ 00 Base T Ethernet®network connection that permits access tc Backbox and backbox with door the control panel from any remote location with the correct D1* D2 D3 04 D5' iD6 07 03 09 communicati ns ls. The can be used to download toothe panel froom the VS-CU,connection upl ad and view 71.1cm 9.8 m 22.8cm 55.8cm 40.o m , .93.c^ 21. c° 2c° 26.0cm 9.9cm 71.6cm 6.8cm system eports using the VS-CU. *Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim kit. Available system reports include: • Correlation groups • Device details • Device maintenance • History • Internal status • System configuration • System status • Walk test • Dialer • CO Runtime Page 3 of 1fl M85005-0130 issue 6 I , I Wiring , Winng I Configuration Notificatio appliance circuits(TB2) Device loop V-Series co trol panels come equipped with two notification The control panel provides one device loop circuit that can sup- appliance ci cuits. Each circLit can be individually configured for port 125 detectors and 125 module addresses.The loop circuit is continuous,temporal, synchronized, latching, and coded output. supervised for opens, shorts, and grounds. Circuit ape ifications Circuit specifications Circuit Type 4 Class B or 2 C ass A,2.5 amps each Device loops 1 loop,expandable to 2,Class A or B,each loop Voltage 24 VFWR supporting up to 250 device addresses Current 6.0 A total,2.5 A max.per circuit at 120/230 VAC 60 Hz Communication Maximum 20 V peak-to-peak 5.0 A total at 23 VAC 50 Hz line voltage 2.5 A max.per circuit Circuit current 0.5 A max Impedance 26 0 total,0.35 _IF max Circuit 660 total,0.5 pF,max EOLR 15 K 0,Y2 W impedance Isolators 64 maximum Class B wiring Class B Wiring Class A Wiring 0 NAC1- -N O NAc * 1.111M11110 Loop 1 SEC +® Data Line EOLR C>, NAC2- Loop 1 PRI -(®111itgeBill 11.011111 e;) NAC2+ lailliMININI +, . Loop Loop Loop Loop TB2 Loop card device device device device Data Line 0 NAC3- 1011114/ 0 NAC3+ la Man Marking indicates EOLR 0 NAC4- output signal aolarity O NAC4+ lailludillin when the circuit is ac- Annunciator loop (TB4) tive,Polarity reverses TB6 when the circuit is not The control panel provides a connection for up to eight serially active,Wire notification driven and supervised remote annunciators. appliances accordingly. Class A wiring Notification appliance Circuit specifications polarity shown in ac- Device loops Class B(Style Y)or Class A(Style Z) 0 NAC1- + ,....„ + .„....„. tee state. O NAC1+ la SN, c"... Circuit voltage 2.55 V - Circuit current 30 mA max O NAC2- + Circuit Up to 8 annunciators or 4000 feet <0 NAC2+ lank impedance _ TB2 Class B Class A 0 0 + Channel 1 Channel 2 Channel 1 Channel 2 O + (S) (I) (S) (S) TB4 (S) (S) (S) (S) TB4 Annunciator Annunciator TB6 ®CH1(+)IN (S)CH1(+)IN (S)CH1(-)IN (S)CH1(-)IN (3)CH2(+)IN G;)CH2(+)IN Auxiliary& 'oroke power outputs (T63) ®CH2(-)IN (5)CH2(-)IN The control p.nel provides two auxiliary power outputs which can be used for sowering ancillary equipment such as remote an- nunciators a d two wire smoke detectors. Aux 2 can be software selected to o oerate continuous.The circuit is supervised for shorts Alarm,trouble,and supervisory relay(TB3) and grounds. The trouble relay is normally-open, held closed, and opens on any Note: For a complete list of devices that can be connected to this trouble event or when the panel is de-energized.The supervisory circuit, refer to the VS Series Compatibility List. relay is normally-open, and closes on any supervisory event.The Circuit sped'cations alarm relay changes over on any alarm event. Circuit voltage. range 21.9 to 28.3 V Relay specifications Resettable cir uit 24 VDC nominal at 500 mA Alarm 1 Trouble Supervisory (Aux power 2) Type Form C Form A Continuous ci cuit 24 VDC nominal at 500 mA. Use this circuit for Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive (Aux power 1) powering two-wire smoke detectors. Note:Any curren above 0.5 amp connected to both Aux 1 and 2 will reduce the total Relay circuits can only be connected to power-limited sources. available NAG po er Oy that amount. Page 4 of 10 M85005-01 30 Issue 6 Option Cards V-Series panels are supported by a complete line of modules and SMK Smoke Power Converter related equipment that onhance performance and extend system The SMK Smoke Power capabilities. Option card. are easy to install and set up.They Converter Module pro- Za voc auxilliary + ®i simply plug directly into he control panel main circuit board or are vides a regulated power (not esettaOle) connected to it with a ri.bon cable. After installation, terminals source for two-wire smoke remain easily accessible for quick connection of field wiring.The circuits connected to a cabinet provides ample oom for wire routing, keeping wiring reat Signature data circuit.The ©I__ --1 1 )©© and easy to service at al times. SMK monitors the operat- SMK 8 7 6 5 + + ing power from the power Power in I Power out supply. When power be- SA-ETH Ethernet trtte`''ace Card gins to degrade, the SMK P;2 g � v`;,-0 5A-ETH wiring The SA-H I H card provides a provides the necessary l P'—En . etwor .nnneetcw nk standard 10/100 Base T Ethernet operating voltage to the Network cable .► p g g Two wire smoke 1 network connection for connect- two-wire smoke detection detectors Ving to an intranet, a local net- circuits. ©p�;o�i�r®,eei work, or the Internet.The card - 16151413 32j1 21110 9 .,,:. 0 ,,,,,,s�„nij + ® can be used to download JP1 – 8o r, configuration programming from the VS-CU to the par el over the a 7 6 5 403 2 1 li network. © _ ^ ® ©- The Ethernet card is installed on Data in D 6a the plastic assembly and con- Two-wire smoke. Ethernet card nects to the main circuit board detectors .4 via a ribbon cable. 0 isi&sA'1®®®®l o 16151413 3U 12 11 10 6 SA-ETH specifications , JP1 Terminate or to next Ethernet 10/100 Base T o 0 - um Operating environment s s s 4 3 Ti,------ Temperature 32 to 120°F(0 to 49°C) 0[&0,6L® I © Humidity 0 to 93%RH, noncondensing at 90°F Data out (32°C) , EMI(specifications Input voltage 21.9 to 28.3 VDC(not resettable) V-SLC Loop Expander Card Output voltage 24 VDC nom.at 200 mA,max.,special The V-SLC Loop Expander Card provides an additiona device applications loop on the control panel.The card expands the control panel's Ground fault 10 k ohm device capacity to 500 total device addresses, 250 per loop. The impedance card is compatible with Class B or Class A wiring. It is compatible Operating environment with VS2 control panels only. Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) The loop expander card connects to connector J7 on the mair Storage temperature -4 to 140°F(-20 to 60°C) circuit board. Compatible electrical North American 4 inch square x 2-1/2 in. Class B Wiring Class A Wiring boxes (64 mm)deep 2 gang box or Standard 4 in. - square box 1-1/2 in.(38 mm)deep + Loop 1 SEC ® —Data Line Wire size 14, 16,or 18 AWG wire(1.5, 1.0,or 0.75 sq. &Ewe + 110 + mm)(Sizes 16 and 18 AWG are preferred) Loop 1 PRI Loop Loop Loop Loop Loop card device device device device Data Line V-SLC specifications Device addresses on loop 125 detectors and 125 modules Wiring Class B(Style Y)or Class A(Style Z) Operating voltage 20 V peak-to-peak Operating current 0.5 A total Circuit impedance 66 0,0.5 pF, max Terminal rating 12 to 18 AWG(0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) Page 5 of 10 M85005-01 30 Issue 6 SA-DACT Dialer CSA-REL Releasing Module The SA-DACT provides corn-nunications between the control The GSA-REL is an analog addressable module that communicates panel and the central station over a telephone line system. It directly with the fire alarm panel Signature loop controller.The GSA- transmits system status changes(events)to a compatible digital REL controls sprinkler, pre-action and deluge systems, and may alarm communicator receiver over the public switched telephone also be used to release extinguishing agents such as CO2, Halon,or network.The dialer is capable of single, dual, or split reporting foam.The module is easily configured in the field and offers a wide of events to two different account and telephone numbers.The range of options that ensure dependable service, while preventing modem feature of the SA-DPCT can also be used for uploading the unnecessary release of extinguishing agent. and downloading panel configuration, history, and current status to a PC running the VS-CU. GSA-RL specifications SA-DAL'r Phone line 2 The dialer phone lines connect to Input voltage 24 Vdc(power limited) wiring Phone line 1Q To wall connectors on the dialer's main circuit Supervisory current 25 mA,max. 91 phone jack board.Phone line 1 connects to connec- Power riser Riser input current 4 amps maximum Phone cables��7 R s tor J4 and phone line 2 connects to Alarm 170 mA min.;4 A max. (supplied) lacks 5 a-J connector J1. Output rating 2 A @ 24 Vdc(per circuit) 1 The SA-DACT queues messages Valves per circuit 4 valves, max. 9 1 Release Max.supervisory current 0.4 mA(short circuit) II3. oo and transmits them based on prior- circuits Nominal supervisory current 0.18 mA 7. 1 D; ty(alarm, supervisory,trouble, and Supervisory voltage 26 Vdc,max.(open circuit) ° o.Qo monitor). Activations are transmitted End of line device 47k Ohm EOL a�0-ii ] before restorations. 2 A @ 24 Vdc(for each °Opl°®° .i.-'° Output rating °°0riE ° � Max.supervisory current circuit) �0❑«00 ❑o The SA-DACT is installed on the Pre-release p ry 0.4 mA(short circuit) ��°° �g ° clastic assembl and connects to the Nominal supervisory current Y alarm circuits Supervisory voltage 0.18 mA 'Hain circuit board via a ribbon cable. End of line device 26 Vdc,max.(open circuit) 47k Ohm resistor SA-DACT s e cifications Max.supervisory current 0.4 mA(short circuit) Phone line type One or two loop-start lines on a publ c, Nominal supervisory current 0.18 mA switched network Manual Supervisory voltage 26 Vdc,max.(open circuit) Phone line connector RJ-31/38X(C31/38X) release input End of line device 47k Ohm resistor circuit Communicat on formats Contact ID(SIA DC-05) Circuit type Class B N.O.latching Operating environment Circuit capacitance 0.1 NF,max Temperature 32 :o 120°F(0 to 49°C) Max.supervisory current 0.4 mA(short circuit) Humidity 0 to 93%RH, noncondensing at 90°F Nominal supervisory current 0.18 mA (32°C) Abort circuit Supervisory voltage 26 Vdc,max.(open circuit) End of line device 47k Ohm resistor Compatible DACRs Circuit type Class B N.O.non-latching ReceiveModels Formats capacitance 0.1 pF,max Ademco 685 Contact ID First alarm 3 A @ 24 Vdc out put rela Contact rating FBI! CP220 Contact ID P y (0.6 power factor)Form C Operating voltage 5.2 to 19.95 Vdc Osborne-Ho man OH 2000 Contact ID Signature Supervisory current 1000 pA Radionics D6600 Contact ID Data line Alarm current 1000 pA Silent Knight 9800 Contact ID Note:Output circuits are power-limited when the riser circuit is power-limited. Sur-Gard SG-MLR-, MLR2 Contact ID VS2 Control Panel O Signature Series smoke detectors • Loop Controller I M I Signature Series modules SA-232 RS-232 interfaceJ Di Horn circuit The SA-232 card provides an RS-232 SA-232 wiring interface with VS2 panels. It can be GND(black wire) I M Strobe circuit TXD(white wire) 1 SD I Service Disconnect Station used for con lecting a printer o the —RXD(red wire) I A I Manual Abort Station control panel to print system events.The MR I Manual Release Station card also car be used for connecting a 't�GG� T Fire Alarm Control Panel 11 First Alarm Output Relay computer to download a conf guration E L_i r program from the VS-CU to the control 1 -HtM —I panel. The RS-232 card is installed cn the plastic assembly and can- Auxiliary RELA-EOL Release Circuitt nects to the main circuit board via a ribbon cable. Auxiliary Releasing Module Power Supply (GSA-REL) SD RELA-EOL Release Circuit2 SA-232 specifications Operating voltage Standard EIA-232 I A I I MR Terminal rating . 12 to18 AWG(0.75 to 2.5 sq mm) For detailed specification and ordering information on the GSA-REL,refer Operating environment to Data Sheet M85001-0531 --Releasing Module. Temperature 32 to-20°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(72°C) Page 6 of 10 5005-0130 Issue 6 Specifications Device loops 1 loop,expandable to 2,Class A or 3,each loop Battery placement VS2 cabinets accommodate up to 18 NH batteries. supporting up to 250 device addresses Use a external cabinet for larger battery sizes. NAC circus s 4 Class B or 2 Class A,2.5 amps each Batteries Batteries must be sealed lead acid type only. Power supply 6.0 A total,2.5 A max.per circuit at 120/230 VAC Maximum charging capacity=26 Ah. 60 Hz Loop circuit Maximum loop resistance:66 D.Maximum loop 5.0 A total at 230VAC 50 Hz,2.5 A max.per capacitance:0.5 pF.Style 4, 6,and 7 wiring. 64 circuit isolators maximum. 0.5 amps aux power GSA-UM/GSA-MAB 1.5 mA(see the UL and ULC compatibility list for NAC Operating 24 VDC.NAC minimum voltage: 19.5 VDC for the maximum quantity of detectors per circuit) voltage 20.4 V battery voltage Compatibility ID 100 SLC Loop circuit 20 V peak-to-peak Alarm contact Form C 24 VDC 1 A(resistive load) operating voltage Trouble contact Form C 24 VDC @ 1 A(resistive load) Primary power 120 VAC,60 Hz,230 VAC 50-60 Hz Supervisory contact Form A 24 VDC @ 1 A(resistive load) Aux Power 1 24 VDC nominal at 500 mA.A SMK module is Environmental Temperature:0 to 49°C(32 to 120'F). (Continuous circuit) required when using the GSA-UM module to Humidity:0 to 93%RH,noncondensing. support two wire smoke detectors. Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 Aux Power 2 24 VDC nominal at 500 mA. mm2) (Resettable circuit) Serial Voltage:2.55 V Current:30 mA max Auxiliary output 19 .0 25.7 VDC communications Base panel Standby: 172 mA Remote annunciator 8 drops max, RS-485 Class A or B current draw Alarm:267 mA Input zones 32 max. Panel History Log 1,000 events Agency Listing UL,CSFM,ULC and NYFD#6020 Ordering Information Part Descripr Ion VS2 Intelligent Multi-Loop Systems,500 analog point capacity VS2-R 1 Loop System,4 NACs, Red door.Surface mount enclosure, 115 Vac, English. VS2-RD 1 Loop System,two-line dialer,4 NACs, Red door.Surface mount enclosure, 115 Vac,English. VS2-G 1 Loop System,4 NACs,Silver door.Surfaoe mount enclosure, 115 Vac, English. VS2-GD 1 Loop System,two-line dialer, 4 NACs,Siker door. Surface mount enclosure, 115 Vac,English. VS2-GC 1 Loop System,4 NACs, 16 zone LED display,Silver door.Surface mount enclosure, 115 Vac,English. VS2-G-F"' 1 Loop System,4 NACs, 16 zone LED display,Silver door.Surface mount enclosure, 115 Vac,French. VS2-G-2(2) 1 Loop System,4 NACs,Silver door.Surface mount enclosure,230 Vac, English, VS2-R-2 22' 1 Loop System,4 NACs, Red door.Surface mount enclosure, 230 Vac, English. VS2-G-SP02j 1 Loop System,500 point capacity,4 NACs,silver door.Surface mount enclosure, 115 Vac,Spanish VS2-G-2 SP 1s 1 Loop System,500 point capacity,4 NACs,silver door.Surface mount enclosure,230 Vac,Spanish VS2-G-PG 02' 1 Loop System,500 point capacity,4 NACs,silver door.Surface mount enclosure, 115 Vac, Portuguese VS2-G-2-PG(2) 1 Loop System,500 point capacity,4 NACs silver door.Surface mount enclosure,230 Vac,Portuguese SA-TRIM2 Flush moult trim,black Replacement Electronics 500elec-VS Replacement Base electronics,Vigilant,50Opt system,includes main hoard,base plate,User interface and 1 loop. 500elec-VS-FR"' Replacement Base electronics,Vigilant, 50Opt system,includes main board,base plate,User interface and 1 loop, French 500elec-VS-SP'21 Replacement Base electronics,Vigilant,50Opt system, includes main board,base plate,User interface and 1 loop,Spanish 500elec-VS-PG?1 Replacement Base electronics,Vigilant, 50Opt system,includes main board,base plate,User interface and 1 loop, Portuguese Option Cards SA-DACT Dual Line Dialer/Modem,supports 4/2 and Contact ID,mounts in cabinet on base plate. SA-232 Serial Port;RS-232),for connection to printers&computers,mounts in cabinet to base plate SA-ETH Ethernet Port,Slave, mounts in cabinet on base plate V-SLC SLC Loop Expansion Module.Adds second oop to VS2 systems,250 point capacity. Mounts in cabinet on main board. D16L-VS LED Annunciator Module, 16 groups,2 LEDs per group with insertable labeling. Mounts in cabinet on VS2 systems. Page{of 10 M85005-0130 6 Remote Annunciators(refer to Data Sheet 85005-0128) LCD Remote Annunciators(mount to standard 4"square electrical box) RLCD Remote Annunciator,4X20 LCD&Common Ind cators for displaying system status.Off-white housing. RLCD-R Remote Annunciator,4X20 LCD&Common Ind cators for displaying system status.Red housing. RLCD-C Remote Annunciator,4X20 LCD.Common cont-ols and status indicators.Off-white housing. RLCD-CR Remote Annunciator,4X20 LCD.Common cont'ols and status indicators.Red housing. RLCDF " Remote Annunciator,4X20 LCD&Common Ind cators for displaying system status.Off-white housing. _ RLCD-CF"' Remote Annunciator,4X20 LCD.Common cont-ols and status indicators.Off-white housing. RLCD-SP l='' Remote Annunciator,4X20 LCD.Common system status indicators.Off-white housing.Spanish. RLCD-PG'2' Remote Annunciator,4X20 LCD.Common system status indicators.Off-white housing. Portuguese. RLCD-C-SP'2) Remote Annunciator,4X20 LCD.Common cont-ols and status indicators.Off-white housing.Spanish. RLCD-C-PG'2( Remote Annunciator,4X20 LCD. Common cont-ols and status indicators.Off-white housing. Portuguese. LED Remote Annunciators&Expander(mount to standard t"square electrical box) RLED-C Remote Annunciator.Common controls and sta us indicators with 16 X 2-LED groups for zone display.Off-white housing. RLED-CR Remote Annunciator.Common controls and sta us indicators with 16 X 2-LED groups for zone display. Red housing. RLED-CF"' Remote Annunciator.Common controls and sta us indicators with 16 X 2-LED groups for zone display.Off-white housing, French. RLED-C-SP'a' Remote Annunciator,common controls and stabs indicators. 16 groups w/2 LEDs each for zone display.Off-white housing.Spanish. RLED-C-PG(2) Remote Annunciator,common controls and stats indicators. 16 groups w/2 LEDs each for zone display.Off-white housing.Portuguese. RLED24 Remote Annunciator Zone expander.24 X 2-LED groups with custom label areas for display of alarm and trouble.Off-white housing. RLED24R Remote Annunciator Zone expander.24 X 2-LED groups with custom label areas for display of alarm and trouble.Red housing. Remote Annunciator Cabinets&Accessories RA-ENC1 Remote Annunciator Enclosure,key locked with plexiglass window for one RLCD(C)or RLED(C). RA-ENC2 Remote Annunciator Enclosure,key locked with plexiglass window with space for 2 of either RLCDx, RLEDx or RLED24. RA-ENC3 Remote Annunciator Enclosure,key locked with plexiglass window with space for 3 of either RLCDx, RLEDx or RLED25. RKEY Keyswitch,single gang,provides key operated Enable or disable of common controls on RLCD or RLED units. LSRA-SB Surface Mount Box-for R Series single units. Graphic Annunciator Drivers(comes with a snap track for mounting in custom graphic enclosures) GCI Provides outputs for common indicators and 32 alarm/sLpv zones as well as inputs for common switches. Programming Tools VS-CU Vigilant VS Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface Notes: ' Available in Canada only. '2'Available in international markets or ly. Analog Addressable Detectors and Bases Shipping Wt. V-PHS Intelligent Analog Optical/Fixed Temperature Detector 0.25(0.11) V-PS Intelligent Analog Optical Smoke Detector 0.25(0.11) V-HRD Intelligent Analog Rate-of-Rise Heat Detector 0.25(0.11) V-HFD Intelligent Analog Fixed Temperature Heat Detector 0.25(0.11) V-PCOS Intelligent Photoelectric Detector with carbon monoxide sensor 0.4(0.16) GSA-SBT Audible(Sounder)Base for CO and Fire De ectors 0.3(0.15) GSA-SD Intelligent Analog Duct Detector 2.4(1.1) B4U Standard Base 0.11 (0.05) RB4U Relay Detector Base 0.11 (0.05) IB4U Isolator Detector Base 0.11 (0.05) SB4U Audible(Sounder)Detector Base 0.11 (0.05) AB4G-SB Surface Box for Audible Base 1.0(0.45) RLED Remote aarm LED, use with standard base only 0.2(.09) System Accessories Shipping Wt, CTM City Tie Module.Mounts in 2-gang electric box.Provides connection to a local energy fire alarm box. 0.6(0.3) BC-1 Battery Cabinet. 14.0"x 18.25"x 7.25"Free-standirg cabinet with key lock.Supports up to 40 Ah batteries. 50.0(22.7) Holds up to 2 12V24A batteries. BC-1R Battery Cabinet-Red. 14.0"x 18.25"x 7.25"Free standing cabinet with key lock.Supports up to 40 Ah 50.0(22.7) batteries. Holds up to 2 12V24A batteries. BC-1 EQ Seismic hardening Kit for VS series panels. ncludes battery hardening for BC-1 enclosure and components to harden panel internal components.See note. I0P3A Isolator Module-RS232. For use with shod haul mcdems. 1.61 (0.7) RPM Reverse Polarity Module 3.0(1.36) MFC-A Multifunct on Fire Cabinet,8"x 14"x 3.5"- RED. 20.6(9.4) MIR-PRT/S System Printer-Desktop style. 36.6(16.6) Page 8of10M85005-0130 issue 6 Analog Addressable Modules hipping Wt, GSA-CC1 Sin jle Input Signal Module(Standard Mount) 0.5(0.23) GSA-MCC1 Single Input Signal Module(UIO Mount) ) 0.18(0.08) GSA-CC1S Synchronization Output Module(Standard Mo int) 0.5(0.23) GSA-MCC1S Synchronization Output Module(UIO Mount) 0.18(0.08) GSA-T3T4 Temporal Pattern Generator 0.2(0.1) GSA-CC2 Dual Input Signal Module(Standard Iv`ount) • 0.5(0.23) GSA-MCC2 Dual Input Signal Module(UIO Mount; 0.18(0.08) GSA-CR Cortrol Relay Module(Standard Mount) 0.4(0.15) GSA-MCR Control Relay Module(UIO Mount) 0.18(0.08) GSA-CRR Polarity Reversal Relay Module(Stancard Mount) 0.4(0.15) GSA-MCRR Polarity Reversal Relay Module(UIO Mount) 0.18(0.08) GSA-RM1 Riser Monitor Module(Standard Mount) 0.5(0.23) GSA-MRM1 Riser Monitor Module(Plug-in) 1 0.18(0.08) GSA-IO Input/Output Module(Standard Mount) j 0.34(0.15) GSA-MID Input/Output Module(Plug-in) 0.22(0.10) GSA-CT1 Sincle Input Module 0.4(0.15) GSA-012 Dua Input Module 0.4(0.15) GSA-MCT2 Dua Input Plug-in(UIO)Module 0.1 (0.05) GSA-IM Faul.Isolator Module 0.5(0.23) GSA-MM1 Monitor Module 0.4(0.15) GSA-REL Analog addressable releasing module 0.5(0.23) 276A-REL Manual releasing station(single-action(.English markings,black text on yellow polycarbonate body. 1.0(0.45) 278A-REL Manual releasing station(double-action).English markings, black text on yellow polycarbonate body. 1.0(0.45) RELA-ABT Manual Abort Station.English markincs,black text on yellow polycarbonate body. 1.0(0.45) RELA SRV 1 Service Disconnect Switch.One n/c ccntact and one n/o contact.English markings,white text on blue 1.0(0.45) polycarbonate body. RELA-EOL Pola'ized end-of-line relay. English markings o stainless steel cover. 0.2(0.1) GSA-VVTM Waterflow/Tamper Module 0.4(0.15) SMK Smoke Power Converter Module 0.4(0.15) Note: For earthquake anchorage,including detailed mounting weights and center of gravity detail,please refer to Seismic Application Glide 310'987- EN.App-oval of panel anchorage to site structure may require local AHJ, structural,or civil engineer -eview. Standby batteries must be mounted externally from fire panel in separately mounted BC-1 enclosure.Order BC-1 and BC-1 EQ separately. • Page 9 of 10 M85005-01 30 issue 6 Contact s... Email: e.wards.fire@fs.utc.com Web: ww.vigilant-fire.corn Vigilant is an EDWARDS brand. 1016 orporate Park Drive Meba e,NC 27302 ©2013 U C Fire&Security Americas Corporati.n,Inc.All rights reserved. Specifica ions subject to change without n.tice.Edwards is part of UTC Climate, I ontrols&Security,a unit of United Te hnologies Corporation. Page 1 of 10M85005-0130 Issue 6