HomeMy WebLinkAboutA16-0017_FA000_1478896365.pdf f aft, \4 a0 F2;G '=.. ( s))F r !❑; Vail Fire&Emergency Servi:es 0 s 3523,r1 ``SFr _ 03/30/16 LEGEND . SYMBOL DEVICE MANUFACTURER/PART# MOUNTING FACP Mount on wall in Fire Alarm Control Panel Firelite MS-96000DLS manufacturer backbox F Manual Pull Station Firelite BG-12 Dual Action Single gang box OP Photoelectric Smoke Detector Firelite SD-355 w/B350LP Base 4" square box Heat Detector Firelite HD-355 w/B350LP Base 4" square box 0 ,Q Horn/Strobe (candela specified) System Sensor P2R Multicandela, wall mount 4" square box v cnLu Strobe (candela specified) System Sensor SR, Multicandela, wall mount 4" square box z 0 F 0 OP F M Monitor Module Firelite MMF-300 4" square box w N O\ Q EOLR Lu V S 9 6 0 0 PROVIDE POWER 0 L FAC P SUPPLY IF SLC CKT NECESSARY FOR NAC CIRCUIT. 0 z DEDICATED 120V TELEPHONE LINES VOLTAGE DROP CALCULATIONS O N Project:Gorsuch Commissary CO Panel:FRCP Wall Mount Voltage Drop Summary 0 15cd 75cd 0 Q SYSTEM 0\ E LI \ E D I AG A V Estimated Horn/Strobe Horn/Strobe Total Load Wire Voltage Drop ♦ ) 2 Circuit# Source Type Length (ft) 0.066 0.176 (Amps) Gauge (4 Volts Max) C NAC(NEW) FACP ' NV 400 3 8 1.606 14 3.0 TN > Om 0 � s4O 0 c) FIRE ALARM WIRE TYPE CHART 4.-- >, > Label Description Wire TypeLo coo AC 120VAC Power Wiring 3#12 AWG Solid (w/Ground) 0 [) c o 0) L Signaling Line Circuit #16 AWG Twisted Pair W co co cr) 0 x P 24VDC Power Wiring 2#14 AWG Solid (/) +, a I N Notification Appliance (Horn/Strobe) Wiring 2#14 AWG Solid (/•' Q 7 X Auxiliary Circuit (Relay) Wiring 2#14 AWG Solid O ti Z Indicating Device Circuit (Zone) Wiring 2#16 AWG Solid °' A Annunciator Wire 2x #16 AWG Twisted Pair �••• _ fills• �',i�Elp, � NOTE: 1 . NO T—TAPPING PERMITTED ON ANY CIRCUIT I- 0 z 0 co ti CO M GD SEQUE\ CE OF z Q PROJECT \ FO � VATIO \ : 1- OPEATIO \ S : w CT) o < o 0 GO SUCH COV V SSA�Y Q Li z 232 3 AGE STREET, VAIL CO 81 657 0 Li O E O C/') MI—I— OM W < z F � E ALARM SYSTEV D cL N o N Q AHJ: VAIL FIRE & EMERGENCY SERVICES L j o ce U w w Q z z APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 z W DEVICE Q 1- _, z z OCCUPANCY: GROUP A-3 Co z Z DESCRIPTION 0 O N ic O ic O USE: RESTAURANT 0 r: _ Q Q > FIRE SUPPRESSION: FULLY SPRINKLERED U H U) MANUAL PULL STATIONS X X X FIRE ALARM WORK FOR GORSUCH COMMISSARY TENANT FINISH. SCOPE OF WORK INCLUDES: J U LLJ = Q J Q • SMOKE AND HEAT DETECTORS THROUGHOUT W Ct HEAT DETECTORS X X X • MANUAL PULL STATIONS AT EXITS Q J 0 • OCCUPANT NOTIFICATION THROUGH HORNS AND STROBES . 0 THE FOLLOWING CIRCUITS WILL BE UTILIZED. SLC: CLASS B, STYLE 4; NAC: CLASS B, STYLE Y; IDC: CLASS B, u) W = W SMOKE DETECTORS X X X STYLE B. LLJ I— 0 KITCHEN HOOD SUPPRESSION X X X THE SLC AND NAC CIRCUITS THAT WERE EXISTING IN THE PREVIOUS TENANT SPACE WILL BE UTILIZED IN THIS O i_TENANT FINISH. U W Q m X X = 0 U 0 AC POWER LOSS LLI GROUND FAULT X X U) m 0FIRE PROTECTION ENGINEER: FIRE ALARM CONTRACTOR: Z (n X SHANER LIFE SAFETY THUL ELECTRONICS O N 0 W OPEN CIRCUIT PO BOX 1073 PO BOX 534 0 RI U I 0 FRISCO, CO 80443 AVON, CO 81620 PHONE: 970-409-9082 PHONE: 970-949-4638 SHEET DESCRIPTION: FIRE ALARM PLAN DRAWN BY: DATE: DLS 3/14/16 SHEET#: FA-0 .00