HomeMy WebLinkAboutA16-0021_FA-0_1478896303.pdf 3QO Vail Fire&Emergenc Services 04/26/16 AHJ - Vail Fire Department Occupancy SYSTEM OUTPUTSBATTERY CALCULATIONS IFC2012 Class - Residential multi - CONTROL PANEL LOCATION: 1st Level Mechanical family 907. 2. 11 . 2 Group R - 3, R - 3, R - 4. SingIe or ANNUNCIATION NOTIFICATION PANEL: ADEMCO 128BPT HOURS OF SUPERVISION: 24 HOURS multiple station smoke alarms shall be MINUTES OF ALARM: 15 MINUTES Device Device Total - o Total Alarm installed regardless of occupant load at �, , y QTY PART NUMBER Supervisory Alarm Supervisory consult April 2016 version DESCRIPTION OF DEVICES Current Current Current Current all of the following locations: m o o Property: 1 ADE-128BPT FACP 0.25000 0.33000 0.25000 0.33000 .� o t) 1 ADE-4204 4zonerelaycard 0.01500 0.16000 0.01500 0.16000 1 . On ceiling or wall outside each separate - o S 8 Iu o Q :, 2645 Bald 1 ESL 204 12/24 End of line power Supervision Module 0.00000 0.01400 0.00000 0.01400 -' S " u 0 Mountain Rd sleeping area . n . 40 H 7) o 1 ESL 405-05 ESL Reversal Relay 0.00000 0.03400 0.00000 0.03400 �; S �, y o p 2. In each room used for sleeping .,- 2 ... N H _ 0 ADE 4208U 8 Zone Expansion 0.02730 0.02730 0.00000 0.00000 � ' 'B Q � � � °' � � � � � � � 1 ADE-6160 Annunciator 0.04000 0.15000 0.04000 0.15000 d ¢ Address: 3. In each story within dwelling unit Q o o 2 ESL 26000 MonitoredCarbonMonoxide Detector 0.00200 0.04000 0.00400 0.08000 Q o o o 5 SYS 4WTAB Monitored Smoke Detector 0.00500 0.05000 0.02500 0.25000 VA I L FIRE INSTALLATION STANDARDS: ¢ ¢ o o ¢ ¢ x x ¢ .4 2645 Bald Mountain Rd. 11 ADE 4193 SN Addressable Modules 0.00150 0.00150 0.01650 0.01650 - - o - .° � 0 z �. o o wall, CO 81657 4 SYS-MHW Interior Siren 0.00000 0.07500 0.00000 0.30000 °�' a.) a" a ° ° C k D 3 6 H 0 1 . Smoke detection required in living rooms, Cg E A H F W ' 1 1 SYS P2RK Exterior Horn Strobe 0.00000 0.21800 0.00000 0.21800 i .� -2 -� y Owner: family rooms and home theaters. 14 . y Y g y y .? Ce Ce Ce C E. 5 SYS-5603 135 degree fixed heat detector 0.00000 0.00000 0.00000 0.00000 o 0 MAC-GD2A Combustible Gas Detector 0.04500 0.07000 0.00000 0.00000 ¢ Q ¢ ¢ Q ¢ ¢ ¢ ¢ ¢ H H H H TOTAL: 0.35050 1.55250 2. Boiler/Mechanical rooms required heat detectors. Smoke or Heat Detector X X X X X X Carbon Monoxide Detector X X X X X X SUPERVISORY: 3. Storage rooms not r e ' d to have smoke detection . Ground Fault X X X General Contractor: SUB-TOTAL: 0.35 AMP - ULF and Associates 24 HOURS OF SUPERVISORY: 24.00 HOURS 4. Garages shall have a sounder. - Open Circuit X X X X Carl Bruggeman SUB-TOTAL: 8.41 AMP HOURS Notification Circuit Trouble X X X X 97 Main St. #300 ALARM: 5. Smokes/Heats shall be oriented to center of area . Low Battery X X X X Edwards, Colorado 81633 SUB-TOTAL: 1.55 AMP AC Power Failure X X X X 970-926-7600 15 MINUTES OF ALARM: 0.25 HOURS 6 . CO required in kitchens and indoor fireplaces. Telephone Line Fault-daily timer test X X SUB-TOTAL: 0.39 AMP HOURS Panel Silence Feature X X 7. Crawl spaces do not require heats unless there isCodeComplience: TOTALS: Sprinkler Flow 2012 International Fire Code TOTAL SUPERVISORY: 8.41 AMP HOURS mechanical equipment installed . Sprinkler Tamper 2010 NFPA-72 Nat. Fire Alarm Code TOTAL ALARM: 0.39 AMP HOURS 2011 NFPA-70 Nat. Electrical Code TOTAL: 8.80 AMP HOURS Vail Fire Ammendments *SPARE OF 20% 1.76 AMP HOURS MINIMUM BATTERY SIZE REQUIRED 10.56 AMP HOURS Levels: BAI1ERIES SUPPLIED 2 x 7 amp 14.00 AMP HOURS / S ys t e 'Y1 Code e f e r e n c e 2 Levels Bldg Height: BATTERY CALCULATIONS: MAIN ALARM CONTROL PANEL 25'± Roof Height Occupancy Loads: Within 21' of door to sleeping area, measured as path of travel. Occupancy Rating: NFPA 72 29.5.1.1 29vR-2 Residential A significant remodel of an existing single family residence is taking Smoke and heat detectors shall be oriented toward the center of ceilings of the protected area. Vail Installation Guidelines 4/23/14 Structure: place. The upper level ceiling is wood tongue & groove and is not Type II/Non-Rated effected by the remodel . We will be installing wireless detection in the / CO On or near ceiling within 'immediate vicinity' of fuel burning appliance. Sq. Footage: NFPA 720 5.5.5.3.1 4053 SgFt f upper level and bunk room because of the ceiling . All wireless devices Outside each sleeping area within 'immediate vicinity' of bedrooms'. NFPA 720 9.4.1.1 Communication Type: are identified on the floor pIans. Mini horns will serve as notification within 15 feet of Within 15 feet of the entrance to each bedroom. Within 25 feet of DACT/POTS Lines in the areas where wireless detection exists. All Equipment and wiring door to sleeping Fuel burning appliance. Colorado HB 1091. Primary Power Location: area. ESL 260-CO Manuf. Guidelines: Place detector at least 5' from floor. Main Elec Panel- Breaker will be replaced with new for this project. Battery calculations only For ceiling, at least 1' from wall. At least 5' from any cooking appliance. Designed and Installed by: reflect hard wired devices. At least 10' from any fuel burning appliance. Sys. Sensor C01224T Manuf. Guidelines: Wall detector at least as high as �� light switch, no closer than 6" from ceiling. Ceiling at least 12" from wall. S c a p e of Wore / ,..„ Superior Alarm & Electronics C DEVICE fVOU \ TI \ G GUIDE 210 Edwards Vill. Blvd. #A108 Edwards, CO 81632 PH 970-926-8788 FX 970-926-8790 SYMBOL DESCRIPTION brad@superioralarmco.com FACP FIRE ALARM CONTROL PANEL OARM ADDRESSABLE RELAY MODULE API REMOTE STATION 0 SMOKE DETECTOR (PHOTOELECTRIC) FKI HORN/SOUNDER SYS# 6101-1759 0135° HEAT DETECTOR FIXED/ROR (TEMP LISTED) /1 HORN WITH STROBE - II��" NATIONAL INSTITUTE FOR CERTIFICATION 15 (NUMBER INDICATES CANDELA) IN ENGINEERING TECHNOLOGIES ANN ANNUNCIATOR 15 (NUMBER DESC IPTI0\ CLASS STYLE TYPE Fire Protection Engineering Technology STROBE Fire Alarm Systems INDICATES CANDELA) ,- -i WATER FLOW SWITCH SIGNALING LINE CIRCUITS/POWER B 4 6 #18 AWG FPLP EOL END OF LINE RESISTOR NOTIFICATION ALARM CIRCUIT/POWER B Y 4 #22 AWG FPLP f-�f VALVE WITH TAMPER SWITCH RE OA\ FIRE DEPARTMENT "KNOX" BOX INITIATING DEVICE CIRCUITS A 4 #18 AWG FPLP AIM ADDRESSABLE INPUT MODULE John Goss CO MONITORED CARBON MONOXIDE DETECTOR NICET # 114260 Level III 0 LEGEND CUSE PLENUM RATED WIRE IN ALL PLENUM SPACES Valid Thru 8/1/17 WIRE CHART ORIG.6/25/1 SCALE: 1/4"=1'0" R//E��V. DATE NOTES: • Point addressable zoning not required. Temporal 3 and 4 sounding shall be provided A • for. A 3 FINAL INSP. Approved as n o e . AS BUILTS: AHJ: Vail Fire Department MLVMike Vaughan COVER PAGE Permit #: PAGE NAME: Title/Bldg/Calcs/Map AHJ : Vail Fire Department - Fire Marshal Mike Vaughan 970 . 479 . 2252 A 0 SHEET 1 OF 3