Loading...
HomeMy WebLinkAboutAdemco Vista 128BPT.PDF Honeywell VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS Iill 111 The VISTA-128BPT is a powerful member of the Honeywell The VISTA-128BPT and VISTA-128BPTSIA are listed for family of commercial alarm panels, integrating burglary, COW residential burglary, residential fire and commercial burglary and access control functions. Many features are available that applications(see agency listings in this document for extend the applications of the VISTA-128BPT while simplifying more details).They are compatible with a wide range of end-user operation. AlarmNet communications products for alarm reporting, uploading/downloading and remote services. FEATURES Standard features •Zone 7 may be used for keyswitch •Group bypass (VISTA-128BPT and VISTA-128BPTSIA): arming/disarming •Arm faulted • Provides nine style-B hardwired zones • Integrates with WIN-PAK access • Event arming • Supports up to 119 additional zones control systems to provide increased using a built-in polling (V-Plex®, users, event log and scheduling • Carbon monoxide(CO)zone multiplex) loop interface • Supports V-Plex addressable type support • Supports up to 127 wireless zones VistaKey access control (up to eight • Expanded high-speed RS 232 using up to two 5800 series wireless doors and 250 cards) capability for third party interface receivers(fewer if usinghardwire and automation Easily programmed and maintained and/or polling loop zones) by Compass Windows-based • Internet upload/download • Provides one power-limited bell circuit downloader over AlarmNet GSM and/or SupportsIP communicators over the panel's delivering 1.7Amp(max)at 12VDC • up to 96 programmable keypad (ECP) bus • Provides the ability to control eight outputs • Ringback support separate partitions independently, • Programmable to meet SIA false each functioning as if it had its own alarm prevention specifications. communicatoorsrs(confirmationfnoAlarmNetr of closing report) separate control To meet UL approval for ANSI/SIA •Accommodates 150 user codes with CP-01-2010, order part number • 24-hour dialer test support for seven authority levels V128BPTSIA AlarmNet devices •Accommodates 32 keypad macro • Supports up to six touchscreen • Supports V-Plex Smart Contact commands per system Advanced User Interface(AUI) feature for improved responsiveness • Keeps a log of up to 512 events devices(6272 or later) on systems with many V-Plex zones • Supports up to 16 compatible • Smoke detector reset at keypad •Telco line cut detection two-wire smoke detectors on zone 1 • Quick exit VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ADDITIONAL FEATURES Basic Hardwired Zones Wireless Expansion Eight Partitions Provides nine style-B hardwired zones Supports up to 127 wireless zones Provides the ability to control eight with the following characteristics: using up to two 5800 Series wireless separate areas independently, each • EOLR supervision (optional for zones receivers(fewer if using hardwire functioning as if it had its own separate 2-8)supporting N.O. or N.C. sensors and/or polling loop zones). control. Partitioning features include: (EOLR supervision required for fire Wireless zones have the following •A Common Lobby partition (1-8), and UL burglary installations) characteristics: which can be programmed to arm • Individually assignable to one of •Supervised by control panel for automatically when the last partition eight partitions check-in signals(except certain that shares the common lobby is • Up to 16 two-wire smoke detectors non-supervised transmitters) armed, and to disarm when the first on zone 1 •Tamper protection for supervised partition that shares the common lobby is disarmed • Four-wire smoke or heat detectors transmitters on zones 1-8(power to four-wire • Individually assignable to one of •A Master partition (9), used strictly to smoke detectors must be supervised eight partitions assign keypads for the purpose of viewing the status of all eight partitions with an EOL device). Listed for Scheduling at the same time(master keypads) residential fire only. Provides the following scheduling •All zones assignable to one of Polling Loop Expansion capabilities: eight partitions Supports up to 119 additional zones •Open/close schedules(for control of • Keypads assignable to one of eight using a built-in polling (V-Plex, multiplex) arming/disarming and reporting) partitions or to Master partition 9 to loop interface. Current draw can total • Holiday schedules(allows different view system status up to 128mA. Polling loop zones have time windows for open/close •Abilityto assign relays to one or all the following characteristics: g y schedules) eight partitions • Must use V-Plex devices •Timed eventsfor activation of relays,( Y Ability to display fire and/or burglary • Supervised by control panel auto-bypassing and unbypassing, and panic and/or trouble conditions • Individually assignable to one of auto-arming and disarming, etc.) at all other partitions' keypads eight partitions •Access schedules(for limiting system (selectable option) • Supports VSI Module access to users by time) • Individually programmable account • Supports 4297 Expander Module • End user output programming mode number, entry delay and exit delay • Maximum wiring distance= (provides 20 timers for output control) by partition 12,000 feet -....ij _ V-Plex Loop -:* ® �I 5193 4101 SN DT7500SN FG1625SN Glassbreak 4208EX Eight-zone 4293SN Adapters Series Smoke Detectors Relay Module V-flex DUAL TEC V-flex Expander and Motion Sensor 4208SN Serialized Eight-zone 5881 Remote Point Module ECP Bus Wireless Receiver 6160 - 7100 Console Strobe Light Notification 4204 Relay ii:i ii Appliances Keyswitch Module �++�� Option 11 4.146 Serial Printer PC Connection I Phone Line to Central Station 748 Horn 1!1111- t„ 111 RS-232 l ,�� —or or—iG �� 78471 GSMV iGSMV NOTE:Please refer to the website(www.honeywell.com/security/hsc)for the latest product information. VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ACCESSORIES Auxiliary Devices Passive Infrared Detectors • 5819- Shock Sensor • 4204 - Relay Module, four form • IS2500SN • 5827BD- Bidirectional Keypad C contacts • DT7500SN • 5853- Glassbreak Detector • 5881 Series RF Receiver supporting V-Plex(Addressable)Contacts • 5898-Wireless DUAL TEC 5800 wireless detectors • 4939SN-WH Motion Sensor • 6160 Alpha Keypad/Annunciator • 5800PIR-OD -Outdoor Motion Sensor • 6220S -System Printer • 4944SN-WH • 4959SN • 5870API -Asset Protection Device Manual Pull Stations • 5800PIR/5800PIR-RES/5800PIR-COM • 5140MPS-1 V-Plex Glassbreak Detectors -Wireless Motion Detectors • 5140MPS-2 • FG1625SN • 580000(580000A- Canada) - V-Plex (addressable) Devices VISTA Interactive Phone Module Wireless Carbon Monoxide Detector • 4101 SN Single Relay/Zone Module • 4286 VIP Module • 5800RP-Wireless Repeater • 4190SN Remote Point Module Optional Communicators • 5808W3(5808W3A-Canada) - two zones •AlarmNet Internet/Intranet Wireless Smoke Detector • 4193SN Two zone Serial Interface communicators and digital cellular • 5809-Wireless Heat Detector Module communicators Commercial Listed • 4208EX- Eight-zone expander for Access Control Wireless Devices ULC commercial installations •VISTAKey V-Plex(addressable) • 5817CB -Commercial UL Burglary, • 4208SN Loop Expansion Module Access Control Universal Contact Monitoring Transmitter* eight zones •VISTAKey-SK Starter Kit • 4209U Group Zoning Module- •VISTAKey-EX Expansion Kit • 5869 Commercial UL Wireless two/four zones Hold-up Button* Wireless Devices • 5881 ENHC and 5883H Receivers • 4293SN One-zone Serial • 5804 Wireless Key Interface Module *When used with 5881 ENHC and/or • 4297 Isolation/Extender Module • 5804BD- Bidirectional Key 5883H receiver. •VSI Short/Overload Isolation Module • 5804BDV Bidirectional Key with voice • 5193SD • 5816 - Door/Window Transmitter • 5193SDT I , - _ Ic • 4193SN 4190SN 4959SN 4944SNCI IS2500SN 4208U Two-zone Serial Interface Modu e Remote Point Module Overhead Door Contact Contact V-Plex PIR Eight-zone Motion Sensor Expansion Module I 5808W3 VISTAKey V-Flex 5881 ENHC J (5808W3A-Canada) Glassbreak Detectors Access Control Commercial Wireless( ireless Receiver Wireless Module ECP Bus (Max Two) Smoke Detector 5800 Series Wireless — 5800PIR Series � III5816 Devices Wireless PIRs —Console DoorNVindow / Transmitter it 4209U ... I Group Zoning. �i nit, Module oust I 5869 Commercial UL' �1, Supports Up To 1 16 Conventional 4204 Wireless Hold-up 5817CB Universal Two-Wire � � Relay Button Contact Monitoring ' Smoke Detectors Module Transmitter VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS SPECIFICATIONS Agency Listed to the Electrical •Standby Time: Four hours min. with Following Standards: •Voltage Input: From Honeywell No. 750mA aux. load using 7AH battery • UL609 Grade A Local Mercantile 1361 Plug-In Transformer or •Circuit Protectors: PTC circuit Premises and Mercantile Safe 1361X10 transformer(for X-10 breakers are used on battery input to and Vault installations)rated 16.5VAC,40 VA protect against reverse battery • UL1610 Grades A,AA • Use 1361 CN plug-in transformer connections and on alarm sounder Central Station for Canada output to protect against wiring faults • UL365 Grades A,M Police Connect •Alarm Sounder Output: (shorts). A solid state circuit breaker • UL985 Household Fire 10VDC-13.8VDC, 1.7 amps max., is used on auxiliary power output to • UL1023 Household Burglar Alarm (UL1023, UL609 installations); protect against wiring faults(shorts). g 750mA less aux. current draw Main Dialer California State Fire Marshall (CSFM) (UL985 installations) • Formats Supported:ADEMCO • UL1635 - Digital Alarm •Auxiliary Power Output: 9.6VDC Contact ID with support for four-digit Communicator System Units 13.8VDC, 750mA max. For UL and ten-digit accounts and • CAN/ULC -S303 installations,the accessories ADEMCO 4+2 Express • CAN/ULC -S304 connected to the output must be UL • Line Seize: Double Pole • CAN/ULC -S545 Listed, and rated to operate in the • Ringer Equivalence: 0.7B above voltage range • CAN/ULC -S1023 Cabinet Dimensions • Backup Battery: 12VDC, 4AH or 7AH • For commercial burglary attack sealed lead acid.YUASA NP4 12 12-1/2" W X 14 1/2" H X 3" D proof requirements, use N5873V4BE (12V, 4AH)or NP7-12 (12V, 7AH) attack proof enclosure provided in recommended VISTA-ULKT kit ORDERING VISTA-128BPT Commercial Burglary Alarm Control Panel (UL Listed) V128BPTSIA SIA Approved Enhanced Commercial Burglary Alarm Control Panel (UL Listed) V128BPTCNKT VISTA-128BPT Commercial Burglary Alarm Control Panel with 1361 CN Transformer(Canada only) For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications 2 Corporate Center Dr. Suite 100 Honeywell ll P.O. Box 9040 Melville, NY 11747 1.800.467.5875 WSTA128BPTD/D April 2011 www.honeywell.com ©2011 Honeywell International Inc.