Loading...
HomeMy WebLinkAboutA16-0026_FA000_1478896378.pdf 4061 OF gr, till. 11 Illi 'In z ec 4.7 10.' IrP FRY aft. 40 kJa! r•, F� r ig4 7V 1463 ASPEN GROVE LANE LEGE\ : e(5.-v,,,.. � � �- �lG Vail Fire&Emergency lervices Ademcv Vista 128 FACP � rr ..pt:: osiozns SYMBOL DEVICE MANUFACTURER/PART# MOUNTING f 04 3523 a4 ii o i Standby a , - ! . Number of Current Total Current FACP Honeywell Vista-128BPT r; ; tt'', Device Type Devices (Amps) (Amps) Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox " * "•. ;:'�t"�; Main FACP CPU 1 X 0.032 = 0.032 -.`-WONAL .� _ 41935N Serial Interface 3 X 0.00015 = 0,00045 KP ''•......--•"' COSMOD4W Module 3 X 0.052 = 0.156 LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox i3 Smoke Detector 4 X 0.0005 = 0.002 i4 Smoke/CO Detector 6 X 0.0005 = 0.003 Combination Smoke & 6160 Keypad 2 X 0.04 = 0.08 0 Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box SUM COLUMN FOR STANDBY LOAD 0.27345 = AMPS Combination Smoke and Alarm Load Oco CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box Number of Current Total Current Device Type Devices (Amps) (Amps) ® System Sensor 5601 P Main FACP CPU 1 X 0.032 = 0.032 Heat Detector w/4193SN Addressable module 4" square box 4193SN Serial Interface 3 X 0.00015 = 0.00045 COSMOD4W Module 3 X 0.075 = 0.225 E Cosmo Interface Module COSMOD4W i3 Smoke Detector 4 X 0.035 = 0.14 i4 Smoke/CO Detector 6 X, 0.04 = 0.24 6160 Keypad 2 X 0.1 = 0.2 KB Knox Box Outside Horn/Strobe 1 X 0.195 = 0.195 SUM COLUMN FOR ALARM LOAD 1.03245 = AMPS U Standby Load Required Standby Time in Hours ,0, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox Current (Amps) z 0.27345 X 24 = 6.56 0 Alarm Load Required Alarm Time in Hours E Current (Amps) (15 MINUTES) GENERAL NOTES: cn 1.03245 X 0.25 = 0.26 0 Add Standby and Alarm Load for Required Ampere Hour Battery 6.82 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN 2 F Multiply by the Derating Factor of 1.2 ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE w Total Ampere Hours Required = 8.19 DEPARTMENT REQUIREMENTS AND NFPA 72. Batteries Provided: 12AHMinimum 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, w PROGRAMMING AND DEVICE OPERATION. Q 0 ZONE LIST ZONE# DESCRIPTION 1 SPRINKLER WATERFLOW d 2 SPRINKLER TAMPER 3 LOWER LEVEL CO DETECTION o 4 LOWER LEVEL SMOKE DETECTION L0 5 MAIN LEVEL CO DETECTION °p 6 MAIN LEVEL SMOKE DETECTION a 7 UPPER LEVEL CO DETECTION r^ cc 8 UPPER LEVEL SMOKE DETECTION v I c 9 GARAGE HEAT DETECTOR J 5 O in 10 SYSTEM TROUBLE SEQUENCE OF z (Li �_ z OPERATIONS: N La z Z z z - -1- UO 00 (n0 z co o 0) m (n W (7) Q V) 1. al 1. O - CO �a 0 z (n 1- 51- -1 O XO Q 0 0 C Wm (n Z W E CO M y d = � Z S- Z 22 m (nW N d co x U z � Q � cnE � E jm `i J ' ° � C) u_ m cn 0 cn 0 cn 0 U O 0 r^ Q g y J DEVICE Q QD (/) 0 No No Q0 a� CC DESCRIPTION Q Q Q �• Q Q a � 1- o 1- o 1- o QO Q0 �•lu•• I **so IIP • 0 z SMOKE DETECTOR X X X F- O z - - - 0 HEAT DETECTOR X X X ti CARBON MONOXIDE DETECTOR X X X SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X OD co CD POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X 1- 0, - C, 0, PROJECT \ EOIVAT O \ : o w 1463 ASPE \ GLOVE LA\ E a_ VAIL COLORADO v E RE ALAV SYSTEV z z D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) 0 < X = 2-WIRE DATA, 2-#16AWG EOL EOL AHJ: VAIL FIRE 8c EMERGENCY SERVICES Ct = O O APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 U N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG z J = Z = 2-WIRE DATA CIRCUIT, 2-#16AWG D D FULLY SPRINKLERED KP = KEYPAD CIRCUITING, 4-#18AWG FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM INCLUDES NEW J J RISER NOTES: �co C?) _I ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE LJJ D CO DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE > = UJ 1 . REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE 0 0 H 0 MORE INFORMATION. 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETSPROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. HEAT DETECTORS 1 0 MANUFACTURERS SPECIFICATIONS. L,N r� L,N r1 WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO C7 < K >- 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (VP) (n'P) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE I CO PRIOR TO INSTALLATION. WIRING DIAGRAM IsW D Z 1 0 HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM SYSTEM. U INCLUDED SUBMITTAL BOOKS. Q LJJ 12OVAC DEDICATED POWER VISTA 128FPB Z U) rN eL Z CONTROL PANEL FLOW SWITCH Q _ I- CD TELEPHONE LINE - FIRE Z TAMPER SWITCH c0 J 0 W TELEPHONE LINE - SECURITY BELL N nWP FIRE PROTECTION ENGINEER: j 0 D OUTPUT - ,O, EOLR DEBORAH SHANER, P.E., SHANER LIFE SAFETY SHEET DESCRIPTION: DATA/COM KP I I I PO BOX 1073, FRISCO, CO 80443 S E� AG SAV OUTPUT KEYPAD KEYPAD PHONE: 970-409-9082 FIRE ALARM PLAN FAX: 970-797- 1898 DRAWN BY: DATE: DLS 4/15/16 SHEET#: FA-0.00