HomeMy WebLinkAboutCut Sheets_5.pdf l ES T TM SIGA-CR Control Relay Module Installation Sheet Installation Install this device in accordance with applicable national and , ® local codes,ordinances,and regulations. s..c, WARNING: Connecting a device that exceeds this module's pilot duty contact ratings may cause activation failure.This B module does not support capacitive loads.See"Specifications" �, / u i on page 3 for contact ratings.1111: r Notes • The module is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should not be disassembled. • This module does not operate without electrical power.As fires frequently cause power interruption, discuss further safeguards with the local fire protection specialist. Description • Install the module within the same room as the device it is The SIGA-CR Control Relay Module is an addressable device controlling. that provides one Form C dry contact output relay. The relay To install the module: contacts transfer when the module is activated. The module requires one address on the signaling line circuit 1. Write the address assigned to the module on the label (SLC).Addresses are assigned electronically.There are no provided, and then apply the label to the module. Remove address switches. the serial number label from the module,and then attach it to the project documentation. Diagnostic LEDs provide visible indication of the state of the 2. Wire in accordance with"Wiring"on page 2. module through the cover plate: • Normal: Green LED flashes 3. Using the self-tapping screw provided, attach the wall plate to the module. See Figure 1. • Alarm/active: Red LED flashes 4. Using the two machine screws provided,attach the wall plate and module to the electrical box. Personality codes Use the personality codes described below to configure the SIGA-CR module. See Table 1 for listing information. Table 1: Personality code listing information Code Description UL 864 CAN/ULC- EN 54-18 S527 8 Signal-dry contact output ✓ ✓ ✓ Personality code 8:Signal-dry contact output. Configures the module as a dry relay contact to control external appliances(door closers,fans, dampers)or equipment shutdown. ©2014 UTC Fire&Security Americas Corporation, Inc. 1 /4 P/N 387023P-EN•REV 11 •ISS 23JAN14 Figure 1:Installing the SIGA-CR module Figure 2:Wiring diagram (1) (2) (3) Sit ,ror.,---) J 1 el ���� (4) . (2) (3) r iibl /�'i r,.� 8 7 6 o �iv \ � ' )' \ 0\`, (4) O gz 4 3 2 1 17® (6)± 111111El± (5) ''-..,1 !:4) (7) (1) Compatible electrical box (4) #6-32 x 5/8 machine screw (1) Normally open contact(NO) (2) SIGA-CR module (2X) (2) Common contact(C) (3) Wall plate (5) #4 x 1/2 self-tapping screw (3) Normally closed contact(NC) (4) Not supervised.Power-limited unless connected to a nonpower- limited source.If the source is nonpower-lirnited,eliminate the Wiring power-limited mark and maintain a minimum of 0.25 in.(6.4 mm) space from power-limited wiring.For other mounting methods, Wire this device in accordance with applicable national and see enclosure and bracket installation sheets to maintain local codes,ordinances,and regulations. separation of power-limited and nonpower-limited wiring.The wire size must be capable of handling fault current from nonpower- Notes limited source. • Refer to the Signature loop controller installation sheet for U or— Use type FPL,FPLR,FPLP,or permitted substitute cables, SLC wiring specifications. provided these power-limited cable conductors extending beyond • Each terminal on the module is limited to a single the jacket are separated by a minimum of 0.25 in.(6.4 mm)space conductor. or by a nonconductive sleeve or nonconductive barrier from all other conductors.Refer to the NFPA 70 National Electrical Code for more details. To wire the module: (5) Signaling line circuit(SLC)to next device 1. Verify that all field wiring is free of opens, shorts, and (6) Signaling line circuit(SLC)from previous device ground faults. (7) Power-limited and supervised 2. Strip 1/4 in. (about 6 mm)from the ends of all wires that connect to the terminal block of the module. When stripping wire ends,exposing more wire may cause a ground fault; exposing less wire may result in a faulty connection. 3. Make all wiring connections as shown in Figure 2. 2/4 P/N 387023P-EN•REV 11 •ISS 23JAN14 Specifications Contact information Operating voltage 15.20 to 19.95 VDC For contact information, see www.est-fire.com. Current Standby 75 pA Activated 75 pA Ground fault impedance 10 kO Contact ratings(pilot duty) 24 VDC at 2 A 120 VACat0.5A Relay type Form C,programmable Circuit designation Signaling line circuits Class A,Style 6 or Class B,Style 4 Wire size 12 to 18 AWG(1.0 to 4.0 mm2) LPCB/CPR electrical box Requirements Plastic box with cover plate,no gaps or unused holes Minimum size W x H x D 2.4 x 3.5 x 1.5 in.(60 x 85 x 38 mm) Compatible electrical boxes 2-1/2 in.(64 mm)deep single-gang box;Standard 4 in.square,1-1/2 in. (38 mm)deep box Operating environment Temperature 32 to 120°F(0 to 49°C) Relative humidity 0 to 93%,noncondensing Storage temperature range -4 to 140°F(-20 to 60°C) Regulatory information Manufacturer Edwards,A Division of UTC Fire&Security Americas Corporation,Inc. 8985 Town Center Parkway,Bradenton,FL 34202,USA Authorized EU manufacturing representative: UTC Fire&Security B.V. Kelvinstraat 7,6003 DH Weert,Netherlands Year of The first two digits of the DATE MFG number manufacture (located on the product identification label)are the year of manufacture. FCC compliance This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference,and(2)this device must accept any interference received,including interference that may cause undesired operation. North American CAN/ULC-S527,UL 864 standards EN 54 EN 54-18:2005 Input/output devices EU compliance C E CPR certificates 0832-CPR-F0330` 2002/96/EC(WEEE directive):Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling,return this product to your _ local supplier upon the purchase of equivalent new equipment,or dispose of it at designated collection points.For more information,see: www.recyclethis.info. P/N 387023P-EN•REV 11 •ISS 23JAN14 3/4 4/4 P/N 387023P-EN•REV 11 •ISS 23JAN14