HomeMy WebLinkAboutA16-0005_FA604_1477928640.pdf 4 IDNET CHANNEL 1:M10 SWITCH SETTINGS IDNET CHANNEL 1:M10 SWTCH SETTINGS E VAIL VALLEY MEDICAL CENTER-WEST WING BSMT 4100es XPDR Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 9 Address 1 2 3 4 5 6 7 8 9 Vail Fire&Emergen , srvi e§ 10/31/16 0C- Standby Total Alarm Total M10-1 2ND FLR ELEVATOR LOBBY X ON 1:M10-126 ADRPUL PULL M10-126 2ND FLR N ICU NURSE STATION 2024 XXXXXX ON Qa 1' Module Qty Description Current Standby Current Alarm ; M10-2 2ND FLR RANDY'S MECHANICAL ROOM X ON 1:M10-127 ADRPUL PULL M10-127 2ND FLR W NURSE STATION 2011 X XXXXXX ON M� C•7 CO E Panel Equipment X X ON 1:M10-128 ADRPUL PULL M10-128 2ND FLR s NURSE STATION 2011 X ON o o 4100-9601 1 LOCAL MODE TRANSPONDER * 0.0870 0.0870 0.0870 0.0870 1:M10-4 SPARE X oN 1:M10-129 PHOTO SMOKE M10-129 2ND FLR CORRIDOR C2COR7 X X ON LU 1:M10-5 SPARE X X ON 1:M10-130 PHOTO SMOKE M10-130 2ND FLR CORRIDOR C2COR8 X x ON Z v 4100-0622 1 DIGITAL AUDIO RISER MODULE 0.0700 0.0700 0.0700 0.0700 -- 0>3 , ,1 1:M10-6 SPARE X X ON 1:M10-131 PHOTO SMOKE M10-131 2ND FLR CORRIDOR C2COR9 X X X ON E 4100-1328 1 DIGITAL 100W AMP,6NAC,120VAC,25V 0.0850 0.0850 3.8000 3.8000 1:M10-7 SPARE X X X ON 1:M10-132 PHOTO SMOKE M10-132 2ND FLR ANTE 2220A X X ON 4100-1334 1 BACKUP DIGITAL 100W AMP,120VAC,25V 2 0.0850 0.0850 0.0000 0.0000 1:M10-8 _ SPARE X oN 1:M10-133 PHOTO SMOKE M10-133 2ND FLR CORRIDOR C2COR10 X X X ON 1:A3: ENHANCED POWER SUPPLY - CHANNEL 1 SWITCH SETTINGS 4100-5311 1 ENHANCED POWER SUPPLY, 3 CHANNELS, IDNet, 120V 0.2250 0.2250 0.4900 0.4900 1:M10-9 SPARE X X oN 1:M10-134 PHOTO SMOKE M10-134 2ND FLR W NURSE STATION 2011 X X X ON [DNw ac Number Device Type HD Candela Custom Label (Max 40 Characters) 1 ¢ o 4100-0634 1 POWER DISTRIBUTION MODULE 120V 0.0000 0.0000 0.0000 0.0000 1:M10-10 SPARE X X ON 1:M10-135 PHOTO SMOKE M10-135 2ND FLR CORRIDOR C2COR5 XXX X ON 1:A3:1-1 SV 49SV-APPLC 15cd 2ND FLR CORRIDOR C2COR8 X ON11■ z 5z in 1:M10-11 SPARE X X X ON _ 1:M10-136 PHOTO SMOKE M10-136 2ND FLR CORRIDOR C2COR4 X x ON 1A3:1-2 VO 59VD-WWF 15cd 2ND FLR STAFF TLT 2021A X ON -0u, a 4100-2320 1 AUDIO EXPANSION BAY KIT 0.0000 0.0000 0.0000 0.0000u, 1:M10-12 SPARE X X ON 1:M10-137 PHOTO SMOKE M10-137 2ND FLR CORRIDOR C2COR4 X X X ON 1:A3:1-3 STRB 4906-9204 30cd 2ND FLR STAFF LOUNGE/ LOCKERS 2021 X X ON gm �aoo` 4100-2300 1 EXPANSION BAY (PHASE 10 ONLY) 0.0000 0.0000 0.0000 0.0000 1:A3:1-4 VO 59VO-WWF 15cd 2ND FLR CONFERENCE ROOM 2022 X ON v a o 0 M10-13 2ND FLR PCU NORTH STAIRWELL X X X oN 1:M10-138 RIAM DHOLDER M10-138 2ND FLR CORRIDOR C2COR8 DHOLD X X X ONX�") 1 Panel Totals 0.5520 4.4470 - 1:A3:1-5 SV 49SV-APPLC 75cd 2ND FLR CORRIDOR C2COR8 X X ON ■ % la w<ui i IDNet Addressable Devices (SLC) M10-14 2ND FLR PCU NORTH CORR BY STAIR X X X oN 1:M10-139 RIAM DHOLDER M10-139 2ND FLR CORRIDOR C2COR10 DHOLD X X X X ON 1:A3:1-6 VO 59VO-WWF 15cd 2ND FLR ANTE 2220A X X ON % opj 1:M10-15 SPARE X XXX ON 1:M10-140 RIAM DHOLDER M10-140 2ND FLR CORRIDOR C2COR7 DHOLD X X X ON 1A3:1-7 SV 49SV-APPLC 75cd 2ND FLR CORRIDOR C2COR10 X X X ON N New 4099-9006 5 ADDRESSABLE DOUBLE ACTION MANUAL STATION, PUSH * 1:M10-16 SPARE X _ ON 1:M10-141 RIAM DHOLDER M10-141 2ND FLR CORRIDOR C2COR1 DHOLD X X X X ON 1A3:1-8 SV 49SV-APPLC 15cd 2ND FLR CORRIDOR C2COR10 X ON ¢"' 8 1:M10-17 SPARE X X ON ]:M]0-142 RIAM DHOLDER M40-142 2ND FLR CORRIDOR C2COR3 DHOLD XXX X ON 1 .03:1-9 SV 49SV-APPLC 15cd 2ND FLR CORRIDOR C2COR5 X X ON42 4090-9002 11 IDNET RELAY IAM * 1:M10-18 SPARE X X oN 1:M10-143 RIAM RELAY M10-143 2ND FLR ELEV 5 SMOKE CURTAIN XXXX X ON 1:A3:1-10 VO 59VD-WWFO WP75 2ND FLR TUB ROOM X X ON 1411 2A 1:A3:1-11 STRB 4906-9204 15cd 2ND FLR CORRIDOR C2COR7 X X X ON �_ 4098-9714 27 TRUEALARM PHOTO SMOKE SENSOR Constant current draw of .8mA standby and .1mA alarm 1:M10-19 SPARE X X X oN 1:M10-144 RPHOTO SDUCT M10-144 2ND FLR CORR C2COR9 EF-7 EXH FSD X XON 1.03:1_12 SV 49SV-APPLC 15cd 2ND FLR CORRIDOR C2COR7 X X ON per address used. Devices requiring additional current are ON H 0 q g 1:M10-20 SPARE X X _ 1:Mt0-145 RPHOTO SDUCT M10-145 2ND FLR C2COR7 AHU-1 SUP FSD X X X ON 1:A3:1-13 SV 49SV-APPLC 15cd 2ND FLR CORRIDOR C2COR5 X XWX ON accounted for in the section labeled "Miscellaneous 1:M10-21 SPARE X X X oN 1:M10-146 RPHOTO SDUCT M10--146 2ND FLR C2COR7 EF-14 EXH FSD X X X aN 1:A3:1-14 STRB 4906-9204 30cd 2ND FLR W NURSE STATION 2011 XXX ON �� 4098-9751 1 TRUEALARM IN-DUCT SENSOR BASE W/ RELAY * Peripheral Devices Requiring Additional System Power"- 1:M10-22 SPARE X X X ON 1:M10-147 RPHOTO SDUCT M10-147 2ND FLR STORAGE AHU-1 SUP FSD X X X XON 1:A3:1-15 VO 59VD-WWF 15cd 2ND FLR HOSPETALIST 2012 XXXX ON till 1 iiiii L.: T2' 4098-9756 15 TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT * ONON 1:A3:1-16 X ON CO - 1:M10-23 SPARE X X X X 1:M10-148 RPHOTO SDUCT M10-148 2ND FLR STORAGE AHU-1 RET FSD X X X a 1:M10-24 SPARE X X oN 1:M10-149 RPHOTO SDUCT M10-149 2ND FLR C2COR1 AHU-1 SUP FSD X X X X ON g 4098-9792 27 TRUEALARM SENSOR BASE * - "I M10-25 2ND FLR PCU NORTH CORR BY RM 216 X X X ON 1:M10-150 RPHOTO SDUCT M10-150 2ND FLR C2COR1 AHU-1 RET FSD X X X X ON Miscellaneous Peripheral Devices That Require (Additional) System Power M10-26 2ND FLR PCU NORTH CORR BY RM 214 X X X oN _ 1:M10-151 RPHOTO SDUCT M10-151 2ND FLR C2COR1 EF-14 EXH FSD XXX X X ON S' L4 E 1:M10-27 SPARE X X X X ON 1:M10-152 RPHOTO SDUCT M10-152 2ND FLR C2COR1 AHU-1 SUP FSD X X X ON ki) 4098-9843 15 ENCAPSULATED RELAY PAM-SD 0.0000 0.0000 0.0150 0.2250 1:M10-28 SPARE X X X oN 1:M10-153 RPHOTO SDUCT M10-153 2ND FLR PAT 2225 5 EF-14 EXH FSO X X X X ON RI 2 4098-9756 15 TRUEALARM DUCT SMOKE SENSOR WJ RELAY OUTPUT 0.0030 0.0450 0.0150 0.2250 X X X'X oN 1:M1D-154 RPHOTO 5DUCT M10-154 2ND FLR PAT 2225 AHU-3 SUP FSD X X X X ON 1:A3:1 Notification SLC Distributed Load Voltage Drop Notification Appliances M10-30 2ND FLR PCU N CORR BY SOILED UTIL _ XXXX oN 1:M10-155 RPHOTO SDUCT M10-155 2ND FLR PAT RM 209 AHU-2 RET FSD X X X X X ON 'g Starting Voltage: 29vdc 4906-9204 1 ADDRESSABLE CEILING MNT MC V/O, WHITE 15 0.0008 0.0008 0.0600 0.0600 M10-31 2ND FLR LAB AREA DR HLDRS X XXXX ON 1:M10-156 RPHOTO SDUCT M10-156 2ND FLR PAT RM 209 AHU-2 SUP FSD XXX X °N Min. Device Voltage: 23.vdc Primary Wire Gauge: 1490 Wire Res. Per Ft. 0.003.1 ® 75' Celsius 4906-9204 2 ADDRESSABLE CEILING MNT MC V/O, WHITE 30 0.0008 0.0016 0.0920 0.1840 M10-32 2ND FLR PCU MECH 273 EXHAUS FAN-2 X oN 1:M10-157 RPHOTO SDUCT M10-157 2ND FLR PAT RM 209 EF-3 EXH FSD X X X X X ON Allowable % Drop: 20.7% Home Run Wire Gauge: 14 a r e > t 9 9 Wire Res. Per Ft. 0.0031 75' Celsius i 49SV-APPLC 12 TA ADDRESSABLE S/V APPLIANCE ONLY, CEIL MT 15 0.0008 0.0096 0.0590 0.7080 1:M10-33 SPARE X X ON 1:M10-158 RPHOTO SDUCT M10-158 2ND FLR PAT RM 209 EF-1 EXH ESD XXXX X ON gs�f :.mak ':- 495V-APPLC 3 TA ADDRESSABLE S/V APPLIANCE ONLY, CELL MT 30 0.0008 0.0024 0.0820 0.2460 M10-34 2ND FLR PCU N TELECOM RM X X °N 1:M10-159 RIAM DHOLDER M10-159 2ND FLR CLEAN SUPPLIES DHDLD XXXXX X °N Class B Calculations �� �+ ON Distance Device Current Voltage Voltage % Vdrop r . •.R•• r 49SV-APPLC 2 TA ADDRESSABLE S/V APPLIANCE ONLY, CEIL MT 75 _ 0.0008 0.0016 0.1450 0.2900 1 M10-35 SPARE X X X 1:M]0-160 SPARE X X • - ; oN ON Branch Device # From (Feet) PID Candela Draw at Device Drop at Device Wire Length N • X X 1:M10-161 SPARE X X X • •: •„ 59VD-WWFO 2 TA ADDR LED V/0, WALL MT, WHITE, WEATHERPROOF WP75 0.0008 0.0016 0.0700 0.1400 oN 1 I:A3:1-1 PANEL 62 49SV-APPLC 15cd 0.0590 0.891 0.339 28.661 Branch 1: 3.38% 35418 1:M10-37 SPARE X X X 1:M10-162 SPARE X X X E 59V0-WWF 10 TA ADDR LED V/0, WALL MT, WHITE 15 0.0008 0.0080 0.0310 0.3100 - 1 1:A3:1-2 1:A3:1-3 27 59VD-WWF 15cd 0.0310 0.031 0.005 28.639 Length: 531 `� 1:14110-38 SPARE X X X ON1:M10-163 SPARE X X X X ON 1 1:A3:1-3 1A3:1-1 29 4906-9204 3Dcd 0.0920 0.092 0.016 28.644 =O.t' �a 59Vfl-WWF 1 TA ADDR LED V/0, WALL MT, WHITE 75 0.000B 0.0008 0.0600 0.0600 oN -::...,:4%p'.' 4e M10-39 2ND FLR PCU CORR BY W NURSE STAT XXX X 1:M10-164 SPARE X X X 1 1:A3:1--4 1:A3:1-1 22 59VD-WWF 15cd 0.0310 0.031 0.004 28.657 �� Peripheral Totals 0.0714 2.4480 - t 1:M10-40 SPARE X X oN 1:M10-165 SPARE X X X X ON 1 1:A3:1-5 1:A3:1-1 41 49SV-APPLC 75cd 0.1450 0.709 0.178 28.482 = f�AL �� x Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices 0.0000 1.1391 - ''�.�pr'�j� 1:M10-41 SPARE X X X ON 1:M10-166 SPARE X X X X ON 1 1:A3:1-6 1:A3:1-7 26 59V0-WWF 15cd 0.0310 0.031 0.005 28.273 '� .i E RUI Totals 0 0.0000 0.0000 _.- 1 1:A3:1-7 1:A3:1-5 59 49SV-APPLC 75cd 0.1450 0.564 0.204 28.278 `� 1:M10-42 SPARE X X X °N 1:M10-167 SPARE X X X X X ON - Address Totals 65 Addresses 0.0520 0.0650 _.-. 1 1:A3:1-8 1:A3:1-7 45 49SV-APPLC 15cd 0.0590 0.419 0.116 28.162 * Device Address current draw included below See Additional Current Draws): System Totals*: Standby 1:M10--43 SPARE X X X K ON 1:M10-168 SPARE X X X ON ( ) Y 0.6754 Alarm 8-0991 • 1 1:A3:1-9 1:.03:1-$ 27 49SV-APPLC 15cd D.059D 0.360 0.060 28.1 D3 E 1:M10-44 SPARE X X X oN 1:M10-169 SPARE X X X X aN 1 1:A3:1-10 1:A3:1-11 30 59VD-WWFO WP75 0.0700 0.070 0.013 28.054 2. Backup Amplifier assumes Main Amplifier alarm current on failure. 1:M10-45 SPARE X X X X ON 1:M10-170 SPARE X X X X ON 1 TAP1 1:A3:1-9 12 _ JBOX 0.0000 0.301 0.022 28.080 Standb Standby 1:M10-46 SPARE X X X X ON 1:M10-171 SPARE X X X X X ON - 1 1:A3:1-11 TAP1 18 4906-9204 15cd 0.0600 0.119 0.013 28.067 f Y Y Alarm Alarm ON ON 1 1:A3:1-12 1:A3:1-11 44 49SV-APPLC 15cd 0.0590 0.059 0.016 28.051 Battery Set #1 (Cabinet/Charger #1) Current Total Current Total 1:M10-47 SPARE XXXX X1:M10-172 SPARE X X X X X X ON 1:M10-]73 SPARE X X X X X ON 1 1:A3:1-13 TAP1 30 49SV-APPLC 15cd 0.0590 0.182 0.034 28.047 s Select ALL Power Supplies on this battery set: -- - 1 1:A3:1-14 1:A3:1-13 26 4906-9204 3Dcd 0.0920 0.123 0.020 28.027 0 1:M10-49 SPARE X X X °N 1:M10-174 SPARE X X X X X ON - EPS-1 0.5384 3.0950 1 1:A3:1-15 1:A3:1-14 33 59VD-WWF 15cd D-0310 0.031 0.006 28.021 E Amp-1 0.0850 3.8000 X X X ON 1:M10-175 SPARE XXXX X XON - 8 1:M1D-51 SPARE X X X X ON 1:M10-176 SPARE X X X ON Sub Total 0.6234 6.8950 - 1 Additional Current Draws: X X X °N 1:M10-177 SPARE X X X X ON IDNac Current Boost for 29vdc Regulated Output ** - X X X X ON 1:M10-178 SPARE X X X X ON I 9 P 0.0000 1.1391 - a - MAPNET/ZDNet Device Address Communication Current 65 x 0.000800 = 0.0520 x 0.001000 = 0.0650 M10-54 2ND FIR PCU WEST STAIRWELL X X X X ON 1:M10-179 SPARE X X X X X ON E. Sub Total 0.6754 8.0991 M10-55 2ND FLR PCU WEST CORR BY STAIR XXX XX ON 1:M10-180 SPARE X X X X ON 1:M10-56 SPARE X X X ON 1:M10-181 SPARE X X X X X ON W 1:M10-57 SPARE X XXX aN 1:M10-182 SPARE X X X X X aN 1:A3: ENHANCED POWER SUPPLY - CHANNEL 2 SWITCH SETTINGS Spare addressable point capacity 20% 13 x 4.0008 = 0.0104 x 0.001 = 0.0130IDNac Number Device Type - M10-58 2ND FLR PCU CORR 290 SECURITY DRP X X X X ON 1:M10-183 SPARE XXX X X XON YP CustomIDR Label (Max 40 Characters) 1 t ) Total 0.6858 8.1121 _ 1:A3:2-1 SV 49SV-APPLC 15cd 2ND FIR CORRIDOR C2COR1 -A3:2-1 X ON 1:M10-59 SPARE XX XXX ON 1:M10-184 SPARE X X X X ON 1:A3:2-2 SV 49SV-APPLC 30cd 2ND FLR ELEV 3/4/5 LOBBY -A3:2-2 X ON Standby Time = 4 Hrs x 0.6858 = 2.7432 Standby Ah M10-60 2ND FLR PCU WEST CORR BY RM V205 X XXX i ON 1:M10-185 SPARE X XXX XON 1:A3:2-3 SV 49SV-APPLC 15cd 2ND FIR CATH LAB CORRIDOR -A3:2-3 X X ry ON T Alarm Time = 15 Min 0.25 x 8.1121 = 2.0280 Alarm Ah 1:M10-61 SPARE X XXXX °N 1:M10-186 SPARE X X X X X ON 1:A3:2-4 VO _ 59V0-WWF 15cd 2ND FIR PED/CATH/EXAM -A3:2--4 X ON ""'� o 4.7712 1:M10-62 SPARE XXXXX ON 1:M10-187 SPARE X X XXX XON 1:A3:2-5 VO 59V0-WWF 15cd 2ND FIR PED/CATH/EXAM -A3:2-5 X X ON 1:A3:2-6 VO 59V0-WWF 15cd 2ND FIR PUBLIC TLT -A3:2-6 X X ON Additional Spare Battery Capacity = 20% + 0.9542 1:M10-63 SPARE X XXXXX °N 1:M10-188 SPARE XXXX X ON 1:A3:2-7 VO 59VD--WWF 15cd 2ND FIR STAFF TLT -A3:2-7 X X X ON I..L .8' 5.7255 "' M10-64 2ND FLR CATH EXHAUST FAN SIGNAL X vN _ 1:M10-189 SPARE K XXXX ---XON 1:A3:2-8 VO 59V0-WWF 15cd 2ND FIR LOCKER -A3:2-8 X ON Battery Discharge Factor = 20% + 1.1451 1:M10-65 SPARE X X oN 1:M10-190 SPARE KXXXX X °N 1:A3:2-9 5V 49SV-APPLC 15cd 2ND FLR CORRIDOR C2COR3 -A3:2-9 X X ON o Lil Minimum Battery Required 2081-9274 10AH (2x) 6.8706 1:M10-66 SPARE ,X K ON 1:M10-191 SPARE XXXXXX XON 1:A3:2-10 VO 59V0-WWF 75cd 2ND FLR CATH LAB -A3:2-10 X X ONic Battery Supplied 2081-9287 25AH (2x) j3:,' M10-67 2ND FLR PCU WEST CORR BY RM V203 X X X °N 1:M10-192 SPARE X X oN 1:A3:2-11 SV 49SV-APPLC 30cd 2ND FLR CORRIDOR C2COR4 -A3:2-11 X X X ON M10-68 2ND FLR WEST ELEVATOR LOBBY X X ON 1:M10-193 SPARE X X X ON 1:.03:2-12 SV 49SV-APPLC 30cd 2ND FLR CORRIDOR C2COR4 -A3:2-12 X X ON z a .,,,, ,, ON oN 1:A3:2-13 SV 49SV-APPLC 15cd 2ND FIR CORRIDOR C2COR5 -A3:2-13 X X X ON , M10--69 2ND FLR PCU WEST CORR BY RM V202 X X X1:M10-194 SPARE X X X T X X X °N 1:M10-195 SPARE X X X X °N 1:A3:2-14 SV 49SV-APPLC 15cd 2ND FIR CORRIDOR C2COR2 -A3:2-14 XXX ON W m 1:.03:2-15 SV 49SV-APPLC 15cd 2ND FLR CORRIDOR C2COR2 -A3:2-15 X X X K ON s 1:M10-71 SPARE X X X X ON 1:M10-196 SPARE X X X ON 1:A3:2-16 VO 59VO-WWFO WP75 2ND FLR ISOLATION SHOWER -A3:2-16 X ON U -I 1:M10-72 SPARE X X ON 1:M10-197 SPARE X X X X ON 1:A3:2-17 VO 59VO-WWF 15cd 2ND FLR ISOLATION ANTE -A3:2-17 X `X- ` ON X X X ON 1:M10--198 SPARE X X X X ON 1:A3:2-18 SV 49SV-APPLC 15cd 2ND FIR CORRIDOR C2COR2 -A3:2-18 X X ON `1 'a - vN ON j 1A3:2-19 X X X ON W 1:M10-74 SPARE X X X 1:M10-199 SPARE X X X X X M10-75 2ND FLR PCU CATH CORRIDOR X X X X ON 1:M10-200 SPARE X X X oN 1:A3:2-20 X X ON g 1:M10-76 SPARE X X X oN 1:M10-201 SPARE X X X X ON 4.` g 1:M10-77 SPARE X X X X ON 1:M10-202 SPARE X X X X ON O 1:: g O - M10-78 2ND FIR PCU CATH CORRIDOR 295 X X X X °N 1:M10-203 SPARE X X X X X ON 0 > W XXXX X ON 1:M10-204 SPARE X X X X ON w Z 1:M10-8D SPARE X X oN 1:M10-205 SPARE X X X X X ON C W j th 15' X X X ON 1:M10-206 SPARE X X X X X ON C 1:M10-82 SPARE X X X oN 1:M10-207 SPARE XXX X X X ON 1:A3:2 Distributed Load Voltage Drop - N"" tri ao "' y °' M10-83 2ND FIR CATH LAB CORR 2-COR-3 X X X X vN 1:M10-208 SPARE X X X ON C; .m - Starting Voltage: 29vdc r' � �, 1:M10-84 SPARE X X X ON 1:M10-209 SPARE X X X X ON Min. Device Voltage: 23.vdc Primary Wire Gauge: 14ga Wire Res. Per Ft- 0.0031 c. 75' Celsius W V Co $ 1:M10-85 SPARE X X X X ON 1:M1O-210 SPARE X X X X ON Allowable % Drop: 207% Home Run Wire Gauge: 1490 Wire Res. Per Ft. 0.0031 75' Celsius J L w Q Q g 1:M10-86 SPARE X X X X ON 1:M10-211 SPARE X X X X X °N J l W Q N j 1:M10-87 SPARE X X X X X oN 1:M10-212 SPARE X X X X ON _ Class B Calculations Voltage Voltage (� �, 1:M10-$8 SPARE X X X ON 1:M10-213 SPARE X X X XX ON Distance Device Current 9 4 Branch c Branch Device # From (Feet) PID Candela Draw at Device Drop at Device % Drop W 0 G U 1:M10-89 SPARE X X X X ON 1:M10-214 SPARE X X X X X ON > J E•- J 1 1:A3:2-1 PANEL 17 49SV-APPLC 15cd 0.0590 0.913 0.095 28.905 Branch 1: 1.16% m M10-90 2ND FIR PCU AHU 3 RET FSD X X X X oN ]:M10-2]5 SPARE XXX X XX ON Length: 530 r Q 0 s LI 1 1:A3:2-2 1:A3:2-1 42 49SV-APPLC 30cd 0.0820 0.082 0.021 28.884 9 n `o 1:M10-91 SPARE X X X X X oN 1:M10-216 _ SPARE X X X X ON V J W (� 1 1:.03:2-3 1:.03:2-1 26 49SV-APPLC 15cd 0.0590 0.399 0.064 28.841 ,�,,,,,� � € 7 M10-92 2ND FLR PCU ENTRANCE CORRIDOR 290 X X K X °N _ 1:M10-217 SPARE X X X X X ON 1 1:A3:2-4 1:A3:2-3 27 59VD-WWF 15cd 0.0310 0.062 0.010 28.831 W m 1:M10-93 SPARE X X X X X °N 1:M10-218 SPARE X X X X X ON 1 1:A3:2-5 1:A3:2-4 18 59VO-WWF 15cd 0.0310 0.031 0.003 28.827 < Q Q ON ON 1 TAP2 1:A3:2-1 9 JBOX 0.0000 0.373 0.021 28.884 M10-94 2ND FLR N PCU WATER FLOW XXXX X 1:M10-219 SPARE X X X X X X -- - 1 1:A3:2-6 _TAP2 13 59VO-WWF 15cd 0.0310 0.031 0.002 28.882 M10-95 2ND FLR N PCU TAMPER XXXXX X ON 1:M10 220 SPARE XXX X X ON m ith1 1:A3:2-7 1:A3:2-8 17 59VO-WWF 15cd 0.0310 0.031 0.003 28.819 M10-96 2ND FLR W PCU FLOW PATIENT RM 209 X X oN 1:M10-221 SPARE X XXX XX ON 1 1:A3:2-8 1:.03:2-9 18 59VD-WWF 15cd 0.0310 0.031 0.003 28.822 1-- - . M10-97 2ND FIR W PCU TMPR PATIENT RM 209 X X X °N 1:M10-222 SPARE XXXX XX ON 1 1:A3:2-9 TAP2 28 49SV-APPLC 15cd 0.0590 0.342 0.059 28.825 4i) ts w -. X X X ON 1:M10-223 SPARE XXXXX X X ON 1 1:A3:2-10 1:A3:2-9 18 59VD-WWF 75cd 0.0600 0.060 0.007 28.819 cn X X X X ON _ 1:M10-224 SPARE X X X ON 1 1:A3:2-11 1:A3:2-9 30 49SV-APPLC 30cd 0.0820 0.223 0.041 28.784 X X X oN 1:M10-225 SPARE X X X X ON 1 1:A3:2-12 1:A3:2-11 46 49SV-APPLC 30cd 0.0820 0.141 0.040 28.744 - o 1 1:A3:2-13 1:A3:2-12 36 49SV-APPLC 15cd 0.0590 0.059 0.013 28.731 N 1:M10-101 SPARE X X X X aN 1:M10-226 SPARE X X X X ON C S - 1 1:A3:2-14 1:A3:2-3 36 495V-APPLC 15cd 0.0590 0.278 0.061 28.780 •�, e X X X X ON 1:M10-227 SPARE X X X X X ON 1 1:A3:2-15 1:A3:2-14 58 49SV-APPLC 15cd 0.0590 0.219 0.078 28.702 - , -' .-3 M10-103 2ND FLR PCU WEST PATIENT SHOWER XXX XX ON 1:M10-228 SPARE X X X X ON 1 TAP3 1:A3:2-15 23 JBOX 0.0000 0.160 0.023 28.679 . XX X ON 1:M10-229 SPARE X X X X X ON 1 1:A3:2-16 TAP3 17 59VO-WWFO WP75 0.0700 0.101 0.011 28.668 2 1:M10-105 SPARE X X X X °N 1:M10-230 SPARE X X X X X ON 1 1:A3:2-17 1:A3:2-16 22 59VD-WWF 15cd 0.0310 0.031 0.004 28.664 . ,- M10-106 2ND FLR PCU W ELECT RM 271B X X X X oN 1:M10-231 SPARE X X X X X X ON 1 1:.03:2-]8 TAP3 29 49SV-APPLC 15cd 0.0590 0.059 0.011 28.668 T. L C 1:M10-107 SPARE X X X X X ON 1:M10-232 SPARE X X X X ON ILI -) 1:M10-108 SPARE X X X X ON 1:M1D-233 SPARE X X X K X ON = _ o H 1:M10-109 SPARE X X K X X ON 1:M10-234 SPARE X X X X X °N o - 1:M10--110 SPARE X X _X X X ON 1:M10-235 SPARE XX X XXX ON M10-111 2ND FLR RANDY'S CLOSET NAC 6 X XXX XX ON 1:M10-236 SPARE XX XXX ON o co X X X ON 1:M10-237 SPARE X XX XXX ON w X XXX ON 1:M10-238 SPARE XXX XXX ON < f X X X X ON - 1:M10-239 SPARE XXXX X X X ON gn co X X X X X ON _ 1:M10-240 SPARE X X X X ON o X X X X ON 1:M10-241 SPARE X XXXX ON a_g X X X X X aN - 1:M10-242 SPARE X X X X X ON c3 c XX XXX ON 1:M10-243 SPARE X X X X X X ON - w o o XXX XXX oN 1:M10-244 SPARE X XXXX ON XXXX ON _ _ 1:M10-245 SPARE X X X X X X ON x f X XXXX °N 1:M10-246SPARE XX XXXXON "' :,,r:0 t�'�' X XXXX ON 1:M10-247 SPARE XXX XXXX ON Q 4 ;,.. Q X X XXXX °N 1:M10-248 SPARE XXXXX a N j N XXXXX °N ]:M 10-2 4 9 •SPARE X XXXXX °N w ! ' g 66 I- ' .` X XXXXX ON 1:M10-250 SPARE X X X X X X ON < I m 5 NOTE THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAM PURPOSES. NOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES. o I iic co THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS. THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS. L- ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING. ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING. ci] N POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES. POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES. L LuS z DRAWN BY: D. R. FRIDAY CHECKED BY: N. S. WILTSIE VAIL VALLEY MEDICAL CENTER-WEST WING BSMT 4100es XPDR Speaker Db Loss Calculations ISSUE DATE: 11/23/15 *Circuit Voltage = 25vrms [Et] MAXIMUM -3 dB DROP JOB#: = E Total Total Wire Est. Ckt. Wire Res. Circuit Speaker Speaker Voltage Watts Actual Max Allowable PROJECT#: 419:989473101 Plan Speaker Speaker Speaker Spkrs Watts Gauge Length Per Foot Resistance Current Resistance At End At End dB Loss Ckt. Length SIMPLEXGRINNELL© 2016 N t SPEAKER CIRCUIT DESCRIPTION Circuit Tap Tap Tap per [P] [D] in [Rw] [RI=2D*Rw] [I=P/Et] [Rs=Et/I] [Es=(Et*Rs) [Pe=(Es) [dB=Log10 [ML=(0.414*Rs) SYSTEM: Amp # Number .5 Watt 1. Watt 2. Watt Circuit Feet j(Rs+RI)] *2/Rs] (Pe/P)*10] /(2*Rw] 2ND FLR WEST WING NORTH Amp-1 1:S13 4 3 7 5. Watts f890 369 0.0078' 5.734 0.200 125.000 23.903 4.571 -.39 db 3330 Ft. FIRE ALARM SYSTEM 2ND FLR WEST WING SOUTH/WEST Amp-1 1:S14 8 2 10 - 6. Watts 1890 530 0.0078 8.236 0.24-0 104.167' 23.168 5.153 -.66 db 2775 Ft. SHEET: SPARE Amp-i 1:515 . Watts 18ga 0.0078_ 0.000 0.000 0.000 0.000: 0.000 . db 0 Ft. - SPARE Amp-1 1:S16 . Watts 1890 0.0078 0.000 0.000 0.000 0.000 0.000 . db 0 Ft. Z r SPARE Amp-I 1:S17 . Watts 18ga' 0.0078 0.000 0. 000 0.000 0.000 0.000 . db 0 Ft. NODE 1 TRANSPONDER 3 r.a SPARE Amp-1 1:518 . Watts 18ga, 0.0078 0.000. 0.000 0.000 0.000_ 0.000 . db 0 Ft. s 8, CALCULATIONS a c. 03 - NI VAIL VALLEY MEDICAL CENTER-WEST WING BSMT - EPS-1 CIRCUIT SUMMARY & VOLTAGE DROP W iTI Alarm Unit Wire Spare Spare o Channel Description Current % Drop Load* Length Current ValtogeDrop " 2 1:A3:1 2ND FLR WEST WING NORTH 1.023A 3.38% 15 531 66% 84% 6 1:A3:2 2ND FLR WEST WING SOUTH/WEST 0.975A 1.16% 18 530 68% 94% FA-604 ii M 1:A3:3 SPARE 0.000A 0.00% 0 _ 0 J 100% 100% 1, g 2 €