HomeMy WebLinkAboutA16-0005_FA605_1477928640.pdf ,4:N,4 -Z- tIletICIF1/4/ .16 4. el 0 j.1+20,101 11 E Vail Fire&Emergencgerrvice 10/31/16 u'"� g o m r`?)coo 0 c%)c. E v diI 1 a_L A E_ _ w m o z o - IS 0, �g a • X011 w J LLj R1.�iikii- v u1L[ �U q 4- gores c Ndo G -Qcco m CI 43 z IDNET CHANNEL 2:M1 SWITCH SEI ZINGS IDNET CHANNEL 2:M1 SWITCH SETTINGS IDNET CHANNEL 2:M2 SWITCH SETTINGS IDNET CHANNEL 2:M2 I SWITCH SETTINGS VAIL VALLEY MEDICAL CENTER-WEST WING 3RD FLR 4100es FACP Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 9 Address 1 2 3 4 5 6 7 8 9 Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 9 Address 1 2 3 4 5 6 7 8 9 CX O Standby Total Alarm Total 2111-1 ADRPUL PULL 111-1 3RD FIR NURSE STATION 3024 X oN 2:111-126 SPARE X X X X X X ON 2:M2-1(1) ADRPUL PULL 112-1 4TH FLR STAIR B STR-3 X ON oN U L Module Oty Description Current Standby Current Al arm O 2:M2-126(2) ADRPUL PULL M2-126 ROOF STAIR C STR-2 XXXXX X 2:M1-2 ADRPUL PULL M1-2 3RD FIR NURSE STATION 3029 X a" 2:111-127 SPARE X X X X X X X °N 2:M2-2(1) ADRPUL PULL 112-2 4TH FIR STAIR A STR-1 X ON 2:M2-127(2) PHOTO VSMOKE M2-127 ROOF STAIR C STR-2 TOP STAIRS XXXXXXX- ON E ~ Panel Equipment 2:M1-3 PHOTO VSMOKE 111-3 3RD FIR I.T. 3004 X X ON 2:M1-128 SPARE X ON 2:M2-3(1) ADRPUL PULL M2-3 4TH FLR STAIR C STR-2 X X VoNCill O 2:112-128(2) PHOTO VSMOKE 112-128 ROOF ELEV-5 MACHINE RM X L' 4100-9311 1 4100 CONTIG. DOMESTIC 120V * 0.4250 0.4250 0.7350 0.7350 2:111-4 PHOTO VSMOKE M1-4 3RD FLR GREETER M3G X ON 2:M1-129 SPARE X X ON 2:M2-4(1) PHOTO VSMOKE M2-4 4T1-I FIR ELEC 4058 X ON 2:M2-129(2) HEAT HEAT 112-129 ROOF ELEV-5 MACHINE RM X X °N 4100-5311 1 ENHANCED POWER SUPPLY, 3 CHANNELS, IDNet, 120V 0.2250 0.2250 0.4900 0.4900 2:M1-5 PHOTO VSMOKE 111-5 3RD FLR CLEAN ANTE RM 3061 X X ON 2:M1-130 SPARE X X ON 2:M2-5(1) PHOTO VSMOKE M2-5 4Th FIR ELEV-5 LOBBY X X ON 2:M2-130(2) RIAM PRIMARY M2--130 ROOF ELEV-5 PRIMARY RECALL X X ON 2:M1-6 PHOTO VSMOKE M1-6 3RD FLR CORR C3CORI X X ON 2:M1-131 SPARE X X X ON 2:M2-6(1) PHOTO VSMOKE M2-6 4TH FLR CORRIDOR C4COR8 X X ON 2:M2-131(2) RIAM ALTERN M2-131 ROOF ELEV-5 ALTERN RECALL X X X ON E ja....A.Z111 4100-1328 1 DIGITAL 100W AMP,fiNAC,120VAC,25V 0.0850 0.0850 3.8000 3.8000 2:M1-7 PHOTO VSMOKE 111-7 3RD FIR ELEC 3008 XXX oN 2:111-132 SPARE X X ON 2;112-7(1) PHOTO VSMOKE 112-7 4TH FLR CORRIDOR C4COR8 XXX ON 2:112-132(2) RIAM RRELAY 112-132 ROOF ELEV-5 FF HAT UTE X X ON 4100-1334 1 BACKUP DIGITAL 100W AMP,12OVAC,25V 2 0.0850 0.0850 0.0000 0.0000 2:M1-8 PHOTO VSMOKE M1-8 3RD FIR PRE-OP CORR C3COR3 X ON 2:M1-133 SPARE X X X ON 2:112-8(1) PHOTO VSMOKE M2-8 4TH FIR CORRIDOR C4COR13 X ON 2:M2-133(2) RIAM RELAY 112-133 ROOF ELEV-5 SHUNT TRIP X X X ON L 4100-6078 1 NETWORK IF CARD, MODULAR 0.0460 0.0460 0.0460 0.0460 2:M1-9 PHOTO VSMOKE M1-9 3RD FLR PRE-OP CORR C3COR6 X X ON 2:M1-134 SPARE X X X °N 2:M2-9(1) PHOTO VSMOKE M2-9 4TH FIR CORRIDOR C4COR14 X X ON 2:M2-134(2) AM SUPERV M2-134 ROOF ELEV-5 POWER MONITOR X X X ON 4100-6056 2 NETWORK MEDIA CARD WIRED 0.0550 0.1100 0.0550 0.1100 2:M1-10 PHOTO VSMOKE M1-10 3RD FLR CORR C3COR7 X X ON 2:111-135 SPARE XXX X oN 2:M2-10(1) PHOTO VSMOKE M2-10 4TH FLR EIEC 4091A X X aN 2:M2-135(2) RPHOTO SDUCT M2-135 ROOF AHU-3 SUPPLY DUCT XXX X ON (n 4100-0622 1 DIGITAL AUDIO RISER MODULE 0.0700 0.0700 0.0700 0.0700 X X X ON 2:111-136 SPARE X X °N 2:M2-11(1) PHOTO VSMOKE M2-11 4TH FLR BIO HAZ HOLD 4090 X X X ON 2:M2-136(2) RPHOTO _ SDUCT M2-136 ROOF AHU-3 RETURN DUCT X X ON 4100-1279 16 2° BLANK DISPLAY MODULE 0.0000 0.0000 0.0000 0.0000 2:M1-12 PHOTO VSMOKE M1-12 3RD FLR PRE-OP CORR C3COR5 X X ON 2:M1-137 SPARE X X X ON 2:M2-.12(1) PHOTO VSMOKE M2-12 4TH FLR SPRANG I.T. 4094 X X ON 2:M2-137(2) RPHOTO SDUCT M2-137 ROOF AWU-2 SUPPLY DUCT -X X X ON rd 4100-0634 1 POWER DISTRIBUTION MODULE 120V 0.0000 0.0000 0.0000 0.0000 2:M1-13 PHOTO VSMOKE M1-13 3RD FLR PRE-OP CORR C3COR4 X X X ON 2:M1-138 SPARE X X X °N 2:M2-13(1) PHOTO VSMOKE M2-13 411-1 FLR CORRIDOR C4COR13 X X X ON 2:M2-138(2) RPHOTO SDUCT M2-138 ROOF AWU-2 RETURN DUCT X X X °N 2:M1-14 PHOTO VSMOKE M1-14 3RD FLR PRE-OP CORR C3COR4 XXX ON 2:M1--139 SPARE X X X X °N 2:M2-14(1) PHOTO VSMOKE M2-14 4TH FLR CORRIDOR C4COR13 XXX °" 2:M2-139(2) PHOTO VSMOKE M2-139 ROOF ELEV-8 TDP OF SHAFT X X X X °N o 4100-2300 2 EXPANSION BAY (PHASE 10 ONLY) 0.0000 0.0000 0.0000 0.0040 2:M1-15 PHOTO VSMOKE M1--15 3RD FLR CORR C3COR8 XXX _X_ ON 2:M1-140 SPARE X X X °N 2:M2-15(1) PHOTO VSMOKE M2-15 4TH FLR CORRIDOR C4COR15 XXXX ON 2:112-140(2) HEAT HEAT M2-140 ROOF ELEV-B TOP OF SHAFT X X X °N gag i �B' 4100-0623 1 BASIC NETWORK TRANSPONDER INTERFACE 0.0350 0.0350 0.0350 0.0350 2:M1-16 PHOTO VSMOKE M1-16 3RD FLR CORR C3COR9 X0.- .. it- ON 2:M1-141 SPARE X X X X ON 2:M2-16(1) PHOTO VSMOKE M2-16 4TH FIR CORRIDOR C4COR16 X ON 2:M2-141(2) PHOTO VSMOKE M2-141 ROOF ELEV-7 TOP OF SHAFT X X X X °" 9L, . 4 4100-2320 1 AUDIO EXPANSION BAY KIT 0.0000 0.0000 _ OA000 0.0000 2:M1-17 PHOTO VSMOKE M1-17 3RD FLR CORR C3COR8E X X oN 2:M1-142 SPARE XXX X °N 2:M2-17(1) PHOTO VSMOKE M2-17 4TH FLR CORRIDOR C4COR13 X X ON 2:M2-.142(2) HEAT HEAT M2--142 ROOF ELEV-7 TOP OF SHAFT XXX X °N %% e( Panel Totals 1.0810 5.2860 2:M1-18 PHOTO VSMOKE M1-18 3RD FLR STORAGE HALL X X ON 2:M1-143 SPARE X X X X X ON ON r `� r 2:112-18(1) PHOTO VSMOKE 112-18 4TH FLR CORRIDOR C4COR17 X X 2:112-143(2) RPHOTO SDUCT 112-143 ROOF AHU-4 RETURN DUCT XXXX X e � � IDNet Addressable Devices (SLC) 2:M1-19 RIAM DHOLDER M1-19 3RD FLR CORR C3COR1 NORTH DHOW X X X ON 2:111-144 SPARE X _X °" °NON 2:112-19(1) PHOTO VSMOKE 112-19 4TH FIR ELEV 7/8 LOBBY X X X 2:112-144{2) RPHOTO SDUCT 112-144 ROOF AHU-4 SUPPLY DUCT X X ,, : 4099-9006 10 ADDRESSABLE DOUBLE ACTION MANUAL STATION, PUSH * 2:M1-20 REAM DHOLDER M1-20 3RD FLR CORR C3COR1 SOUTH DHOW X X ON 2:M1-145 SPARE X X X ON 2:M2-20(1) PHOTO VSMOKE M2-20 4Th FIR CORRIDOR C4COR1 X X oN ON i 35-418r E ( ) 2:112-145(2) RIAM RELAY 112-145 ROOF EF-1 FAN CNTRL X X X 3 - } 2:M1--21 RIAM DHOLDER M1-21 3RD FLR CORR C3COR1 WEST DHOW X X X ON 2:M1-146 SPARE X X X ON 2:112-21(1) PHOTO VSMOKE M2-21 4TH FLR SUBWAIT M4SW X X X ONoN r 4- 4090-9001 9 IDNET SUPERVISED LAM * 2112-146(2) REAM RELAY M2-146 ROOF EF-2 FAN CNTRL X X X �{• a' 2:M1-22 RIAM DHOLDER M1-22 3RD FLR CORR C3COR8E DHOW X X X_ ON 2:M1--147 SPARE X X X X oN 2:M2-22(1) PHOTO VSMOKE M2-22 4TH FIR SUBWAIT M4SW X X X ON 2:M2-147(2) RIAM RELAY M2-147 ROOF EF-3 FAN CNTRL X X X X °N _+�t*� �'"s""' *tlje 15 4090-9002 32 IDNET RELAY IAM * RAM RELAY M2-148 ROOF EF-5 FAN CNTRL X X X oN r '��i 1t- .►0 g Constant current draw of .SmA standby and .1mA alarm 2:111-23 RIAM DHOLDER 111-23 3RD FLR PRE-OP CORK C3COR6 DHOW XXX X O" 2:111-148 SPARE X X X °N 2;112-23(1) PHOTO VSMOKE 112-23 4TH FLR WAFTING 4006 NORTH XXX X °" 2:112-148(2) ���..�frr. 4098-9714 92 TRUEALARM PHOTO SMOKE SENSOR per address used. Devices requiring additional current are 2:M1-24 REAM DHOLDER M1-24 3RD FLR CORR C3COR2 DHOW X X oN M1-149 3RD FLR CORR C3COR1 0 STAIR C X X X X °N - 2:M2-24(1} PHOTO VSMOKE M2--24 4TH FLR WAFTING 4006 SOUTH X X ON 2:112-149(2) RIAM RELAY M2-149 ROOF EF-10 FAN CNTRL X X X X °N ��9'1 8 accounted for in the section labeled Miscellaneous 1 4098-9733 6 TRUEALARM HEAT SENSOR Peripheral Devices Requiring Additional System Power'. 2:M1-25 REAM DHOLDER M1--25 3RD FIR CORR C3COR7 DHOW X X X ON X X X X ON 2:M2-25(1) PHOTO VSMOKE M2-25 4TH FLR CORRIDOR C4COR4 X X X ON 2:112-150(2) REAM RELAY M2-150 ROOF EF-11 FAN CNTRL X X X X °N 4098-9756 _34 -TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT * 2:M1-26 RIAM DHOLDER M1-26 3RD FLR PRE-OP MEDS 3026 DHOW X X X ON 2:M1-151 SPARE XXX X X °N 2:M2-26(1) PHOTO VSMOKE M2-26 4111 FIR CORRIDOR C4COR3 X X X ON 2:M2-151(2) RAM RELAY M2-151 ROOF EF-14 FAN CNTRL XXX X X "I 2:M1-27 RIAM DHOLDER M1-27 3RD FLR PRE-OP CORR C3COR3 DHOW X X X X ON 2:M1-152 SPARE X X X ON 2:M2-27(1) PHOTO VSMOKE M2-27 4TH FIR CORRIDOR C4COR4 X X X X O" 2:M2-152(2) REAM RELAY M2-152 ROOF EF-7 FAN CNTRL X X X O" * 2:M1-28 REAM DHOLDER M1-28 3RD FLR VESTIBULE 3070 DHOW X X X ON 2:M1-153 SPARE X X X X °N 2:112-28(1) PHOTO VSMOKE M2-28 4TH FLR CORRIDOR C4COR5 X X X ON 2:M2-153(2) REAM RELAY M2-153 ROOF EF-8 FAN CNTRL X X X X ON g 4098-9792 98 TRUEALARM SENSOR BASE 2:M1-29 RPHOTO SDUCT M1-29 3RD FLR SURG SUPPORT EF-8 EXH FSD _ X XXX °N 2:111-154 SPARE X X X X °" 2:M2-29(1) PHOTO VSMOKE 112-29 4TH FLR CORRIDOR C4COR4 X XXX °N ( ) 2:M2-154(2) REAM RELAY M2-154 ROOF EF-6 FAN CNTRL X X X X Miscellaneous Peripheral Devices That Require (Additional) System Power 2:111-30 RPHOTO SDUCT M1-30 3RD FLR SURG SUPPORT EF-8 EXH FSD XXXX ON 2:111-155 SPARE X X X X X °" 2:M2-30(1) PHOTO VSMOKE 112-30 4TH FLR CORRIDOR C4COR5 XXXX oN V ( ) 2:M2-155(2) REAM RELAY M2-155 ROOF EF-4 FAN CNTRL X X X X X 4098-9843 34 ENCAPSULATED RELAY PAM--SD 0.0000 0.0000 0.0150 0.5100 2:M1-31 RPHOTO SDUCT M1-31 3RD FL SURG SUPPORT EF-1t EXH FSD XXXXX ON 2:M1-156 SPARE XXX X °N 2:M2-31(1) PHOTO VSMOKE M2-31 4111 FLR CORRIDOR C4COR6 XXXXX oN 2:M2--156(2) RAM RELAY M2-156 ROOF EF-9 FAN CNTRL XXX X °N 4098-9756 34 TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT 0.0030 0.1020 0.0150 0.5100 2:M1-32 RPHOTO SDUCT M1-32 3RD FL CORR C3COR10 EF-11 EXH FSD X ON 2:M1-157 SPARE X X X X X °N 2:M2-32(1) PHOTO VSMOKE M2-32 4TH FLR CORRIDOR C4COR6 X °N 2:M2-157(2) RIAM RELAY 112-157 ROOF EF-12 FAN CNTRL X X X X X ON o Notification Appliances 2:M1-33 RPHOTO SDUCT M1-33 3RD FIR COR C3COR11 EF-11 EXH FSD X X ON 2:M1-158 SPARE XXXX X ON 2:112-33(1) PHOTO VSMOKE M2-33 4TH FLR CORRIDOR C4COR3 X X °N 2:M2-158(2) REAM RELAY M2-158 ROOF EF-15 FAN CNTRL XXXX X ON € 4906-9204 22 ADDRESSABLE CEIUNG MNT MC V/0, WHITE 15 0.0008 0.0176 0.0600 1.3200 2:M1-34 RPHOTO SDUCT M1-34 3RD FLR PRE-OP AHU-3 SUP FSD X X O" 2:M1-159 SPARE XXXXX X ON 2:M2--34(1) PHOTO VSMOKE M2-34 4TH FLR CORRIDOR C4COR4 X X °N 2:M2-159 SPARE X X XXX X °N E 4906-9204 1 ADDRESSABLE CEILING MNT MC V/0, WHITE 30 0.0008 0.0008 0.0920 0.0920 2:M1-35 RPHOTO SDUCT M1-35 3RD FLR PRE-OP AHU-3 RET FSD X X X O" 2:M1-160 SPARE X X °N 2:M2-35(1) PHOTO VSMOKE M2-35 4TH FLR STAFF LOUNGE 4050 X X X ON 2:M2-160 - - SPARE X X °N B 4906-9204 3 ADDRESSABLE CEIUNG MNT MC V/O, WHITE 75 0.0008 0.0024 0.1800 0.5400 2:M1-35 RPHOTO SDUCT M1-36 3RD FLR PAT 3016 AHU-3 SUP FSD X X O" 2:1/1-161 SPARE X X X °N 2:M2-36(1) PHOTO VSMOKE 112-36 4TH FLR CORRIDOR C4COR2 X X ON 2:M2-161 SPARE X X X ON 2:M1-37 RPHOTO SDUCT M1-37 3RD FLR PAT 3016 AHU-3 RET FSD X X X ON 2:M1-162 SPARE X X XON 2:112-37(1) PHOTO VSMOKE M2-37 4TH FLR CORRIDOR C4COR10 X X X °N 2:M2-162 SPARE X X X ON ` 49SV-APPLC 1 TA ADDRESSABLE S/V APPLIANCE ONLY, CEIL MT 110 0.0008 0.0008 0.1930 0.1930 2;111-38 RPHOTO SDUCT 111-38 3RD FLR PAT 3015 EF-14 EXH FSD X X X °H 2:M1-163 SPARE X X X X °" 2:M2-38(1) PHOTO VSMOKE 112-38 4TH FLR CORRIDOR C4COR2 X X X °N 2:112-163 SPARE X X X X °" -E 49SV-APPLC 58 TA ADDRESSABLE S/V APPLIANCE ONLY, CEIL MT 15 0.0008 0.0464 0.0590 3.4220 2:M1-39 RPHOTO SDUCT M1-39 3RD FLR LOCKERS 3042 EF-5 EXH FSD X X X X ON 2:111-164 SPARE X X X ON 2:M2-39(1) PHOTO VSMOKE M2-39 4TH FIR CORRIDOR C4COR6 XXX X °" 2:M2-164 SPARE X X X °N 49SV--APPLC 9 TA ADDRESSABLE S/V APPLIANCE ONLY, CEIL MT 30 0.0008 0.0072 0.0820 0.7380 2:M1-40 RPHOTO SDUCT M1-40 3RD FLR SPD 3054 AHU-2 SUP FSD X X ON 2:M1--165 SPARE X X X X oN 2:M2-40(1) PHOTO VSMOKE M2-40 4TH FLR CORRIDOR C4COR2 X X °N 2:M2-165 SPARE X X X X °N 49SV-APPLC 4 TA ADDRESSABLE S/V APPLIANCE ONLY, CEIL MT 75 0.0008 0.0032 0.1450 0.5800 2:M1-41 RPHOTO SDUCT M1-41 3RD FLR SPD 3054 AHU-2 RET FSD X X X °N 2:M1-166 SPARE X X X X ON 2:M2-41(1) PHOTO VSMOKE M2-41 4T1-1 FIR CORRIDOR C4COR2 X X X ON 2:M2-166 SPARE X X X XON 495V-APPLW 2 TA ADDRESSABLE S/V APPLIANCE ONLY, WALL MT 15 0.0008 0.0016 0.0470 0.0940 2:M1-42 RPHOTO SDUCT M1-42 3RD FLR CARTS 3071 EF-4 EXH FSD X X X ON 2:M1-167 SPARE X X X X X ON 2:M2-42(1) PHOTO VSMOKE M2-42 4T1-1 FIR CORRIDOR C4COR10 X X X ON 2:M2-167 SPARE X X X X X °N i 49SV-APPLW 2 TA ADDRESSABLE S/V APPLIANCE ONLY, WALL MT 30 0.0008 0.0016 0.0570 0.1140 2:111-43 PHOTO VSMOKE M1-43 3RD FLR CORR C3COR2 X X X X ON 2:M1-168 SPARE X X X ON 2:M2-43(1) PHOTO VSMOKE M2-43 4T1-1 FIR CORRIDOR C4COR11 X X X X °N 2:M2-168 SPARE X X X ON CD o 49SV-APPLW 1 TA ADDRESSABLE S/V APPLIANCE ONLY, WAIL MT 75 0.0008 _ 0.0008 0.1000 0.1000 2:M1-44 PHOTO VSMOKE M1-44 3RD FLR CORR C3COR7 X X X °N 2:M1-169 SPARE X X X X oe 2:M2-44(1) PHOTO VSMOKE M2-44 4TH FLR CORRIDOR C4COR12 X X X oN 2:M2-169 SPARE X X X XON 59V0-WWF 28 TA PDDR LED V/0, WALL MT, WHITE 15 0.0008 0.0224 0.0310 0.8680 2:M1--45 ADRPUL PULL M1-45 .3RD FLR CONTROL/SCHEDULER 3064 X XX X aN 2:M1-170 SPARE X X X X °N 2:M2-45(1) PHOTO VSMOKE M2-45 4TH FLR CORRIDOR C4COR12 X X X X °N 2:M2-170 SPARE X X X X a" 59V0-WWF 5 TA PDDR LED V/0, WALL MT, WHITE 30 0.0008 0.0040 0.0440 0.2200 2:M1-46 SPARE X X X X ON 2:M1-171 SPARE X X X X X ON 2:M2-46(1) PHOTO VSMOKE M2-46 4TH FIR CORRIDOR C4COR9 X X X X ON 2:M2-171 SPARE X X X X X ON Peripheral Totals 0.2108 9.3010 2'111-47 SPARE XXXX X oN 2:M1-172 SPARE X X X X oN 2:M2-47(1) PHOTO VSMOKE M2-47 4TH FLR CORRIDOR C4COR9 XXXX X oN 2:M2-172 SPARE X X X X oN n Added Current for EPS Conversion of 24 to 29 Volt IONaa Devices 0.0000 4.7211 2:M1-48 SPARE X X ON 2:M1-173 SPARE X X X X X oN 2:M2-48(1) PHOTO VSMOKE M2-48 4TH FLR STAIR B STR-3 TOP STAIRS X X ON 2:M2-173 SPARE X X X X X O" L, RUI Totals 0 0.0000 0.0000 2:M1-49 SPARE X X X ON 2:M1-174 SPARE X X X X X ON 2:M2-49(1) PHOTO VSMOKE M2-49 4TH FLR STAIR A STR-1 TOP STAIRS X X X ON 2:M2-174 SPARE X X X X X ON E Ct Address Totals 184 Addresses 0.1472 0.1840 2:111-50 SPARE X X X ON 2:M1--175 SPARE X XX X X XON 2:M2-50(1) PHOTO VSMOKE M2-50 4T1-1 FLR ELEV-5 TOP OF SHAFT X X X ON 2:M2-175 SPARE X X X X X XON * Device Address current draw included below (See Additional Current Draws): System Totals*: Standby 1.4390 Alarm 19.4921 o. 2:M1-51 SPARE X X X X oN 2:111-176 SPARE X X X ON 2:M2--51(1) _ HEAT HEAT M2-51 4TH FIR ELEV-5 TOP OF SHAFT X X X X ON 2:M2-176 SPARE X X X ON 8 2:M1-52 SPARE X X X ON 2:111-177 SPARE X X X X ON 2:M2-52(1) LAM WATER M2-52 4T11 FLR NORTH STAIRb B STR-3 X X X ON 2:M2-177 SPARE X X X X ON w 6 2. Backup Amplifier assumes Main Amplifier alarm current on failure. 2:111-53 SPARE X X XX as 2:M1-178 SPARE X X X X ON 2:M2-53(1) IAM SO M2-53 4T1-1 FLR NORTH STAIR B STR-3 X X X X ON 2:112-178 SPARE X X X X ON StandbyStandby2:M1-54 SPARE X X X X ON 2:M1-179 SPARE X X X X X oN 2:M2-54 1 IAM WATER M2-54 4TH FLR WEST STAIR A STR-1 X X X X ON 2:M2-179 SPARE X X X X X ON Alarm Alarm _ ( ) 2:M1-55 SPARE XXX XX aN 2:111-180 SPARE X X X X ON 2:M2-55 1 IAM SO M2-55 4Th FLR WEST STAIR A STR-1 XXX X X ON 2:M2-180 SPARE X X X X ON Battery Set #1 (Cabinet/Charger #1) Current Total Current Total - ( ) Select ALL Power Supplies on this battery set: 2:M1-56 SPARE X X X °N 2:M1-181 SPARE X X X X X ON 2:M2-56(1) RPHOTO SDUCT M2-56 4TH FLR MACH 4102 AHU-2 RET FSD X X X ON 2:M2-1B1 SPARE X X X X X ON EPS-1 0.9202 5.4530 2:M1-57 SPARE X X X X ON 2:M1-182 SPARE XX X X XON 2:112-57(1) RPHOTO SDUCT M2--57 4TH FLR MACH 4102 AHU-2 SUP FSD X X X X ON 2:M2-182 SPARE X X X X X as W EPS-2 0.2866 5.334-0 2:M1-58 SPARE X X X X ON 2:M1-183 SPARE XXX XX XON 2:M2-58(1) RPHOTO SDUCT M2-58 4TH FIR BME 4097 EF-9 EXH FSD X X X X ON 2:M2-183 SPARE XXX XX XON Amp-1 0.0850 3.8000 2:M1-59 SPARE XX XXX ON 2:M1-184 SPARE X X X X ON 2:M2-59(1) RPHOTO SDUCT M2-59 4Th FIR STAFF 4082 EF-11 EXH FSD X X XXX ON 2:M2-184 SPARE X X X X ON y Sub Total 1.2918 14.5870 2:M1-60 SPARE XXXX ON M1-185 3RD FIR CORR C3COR1 X X X X X ON 2:M2-60(1) RPHOTO SDUCT M2-60 4T1-1 FIR EXAM 4053 AHU--3 SUP FSD XXXX ON 2:M2-185 SPARE X X X X X ON J . _ ■ 2 2:M1-61 SPARE X XXXX ON 2:M1-186 SPARE X X X X X ON oN °N W Additional Current Draws: 2:112-61(1) RPHOTO SDUCT 112-61 4TH FLR EXAM 4029 AHU-3 RET FSD X XXXX 2:M2-186 SPARE X XXX X IDNac Current Boost for 29vdc Regulated Output ** 0.0000 4.7211 2:M1-62 SPARE XXXXX oN 2:M1-187 SPARE XX XXX XON 2;112-62(1) RPHOTO SDUCT 112-62 4TH FLR WAITING 4006 EF-5 EXH FSD XXXXX °N 2:112-187 SPARE XX XXX XON r MAPNET/ZDNet Device Address Communication Current 184 x 0.000800 = 0.1472 x 0.001000 = 0.1840 2:M1-63 SPARE XXXXXX O" 2:M1-188 SPARE XXXX X O" 2:M2-63(1) RPHOTO SDUCT M2-63 4TH FIR OFF 4043 AHU-3 SUP FSD X XXXX X ON 2:M2--188 SPARE ,X_X XX XON r , y Sub Total 1.4390 19.4921- 2:M1-64 SPARE X ON M1-189 3RD FIR CORR X XX XX XON 2:M2-64(1) RPHOTO SDUCT M2-64 4TH FIR OFF 4043 AHU-3 RET FSD X oN 2:M2-189 SPARE X XXXX X O" `J C) E 2:M1-65 SPARE X X ON 111-190 3RD FIR CORR C3COR2 XXXXX X °N 2:112-65(1) RPHOTO SDUCT 112-65 4TH FIR STAFF 4044 EF-14 EXH FSD X X °N 2:1 2-190 SPARE XXX X X X oN _ Q crED Spore addressable point capacity 20% 37 x 0.0008 = 0.0296 x 0.001 = OA370 2:M1-66 SPARE X X oN M1-191 3RD FLR CORR C3COR2 X X X X X X XON 2:M2-66(1) RPHOTO SDUCT M2-66 4TH FLR ELEV-7/8 AHU-2 SUP FSD X X as 2:M2-191 SPARE XXXX XX X °N 0 w € Total 1.4686 19.5291 -- M1-67 3RD FLR AMBL SURGE PACU PAT ELEV X X X ON 2:M1-192 SPARE X X ON 2:M2-67(1) RPHOTO SDUCT M2-67 4Th FLR CORR 4-COR-1 EF-1 EXH FSD X X X ON 2:M2-192 _ SPARE X X ON LLI F- Li_ 2:M1-68 SPARE X X ON .. 111-193 3RD FLR WEST WATER FLOW X X X °" 2:M2-68(1) RPHOTO SDUCT M2-68 4TH FLR CORR 4-COR-1 EF-2 EXH FSD X X ON 2:M2-193 SPARE X X X ON Z W F Li. Standby Time = 4 Hrs x 1.4686 = 5.8744 Standby Ah 2:M1-69 SPARE X X X oN M1-194 3RD FIR WEST TAMPER SWITCH X X X ON 2:M2-69(1) RPHOTO SDUCT M2-69 4T1-1 FLR CORR 4-COR-1 EF-3 EXH FSD X X X ON 2:M2-194 SPARE X X X ON < w > H 15) Alarm Time = 15 Min 0.25 x 19.5291 = 4.8823 Alarm Ai 2:M1-70 SPARE X X X oN 2:M1-195 SPARE X X X X °N - 2:112-70(1) RIAM RRELAY M2-70 4TH FLR ELEV-8 SMOKE CURTAN X X X ON 2:M2-195 SPARE X X X X aN U - 10.7567 2:M1-71 SPARE X X X X ON 2:M1-196 SPARE X X X ONONON _ 2;112-71(1) REAM RRELAY 112-71 4TH FLR ELEV-7 SMOKE CURTAIN XXX X 2:M2-196 SPARE X X X J Y co Additional Spare Battery Capacity = 20% + 2.1513 2:111-72 SPARE X X eN 2:111-197 SPARE X X X X ON a+ aN Q - C. 2:112-72(1) RIAM RRELAY 112-72 4TH FLR ELEV-5 EMOKE CURTAIN X X 2:112-197 SPARE X X X X r n U 12.9080 2:M1-73 SPARE X X X ON 2:M1-198 SPARE X X X XONON ON `.J 7' cv 2:112-73(1} REAM DHOLDER 112-73 4TH FLR CORRIDOR C4COR13 DHOW X X X 2:112-196 SPARE X X X XCO E Battery Discharge Factor = 20% + 2.5816 2:M1-74 SPARE X X X ON 2:M1-199 SPARE X X X X X ON 2:M2-74 SPARE X X X ON 2:M2-199 SPARE X X X X X ON I z 0 O Q r� Minimum Battery Required 2081-9275 18AH (2x) 15.4896 2:M1-75 SPARE X X X X oN 2:111-200 SPARE X X X oN 2:M2-75 SPARE X X X X oN 2:M2-200 SPARE X X X ON LLQ 0 0 - `J_` Battery Supplied 2081-9287 25AH (2x) 2:M1-76 SPARE X X X ON 2:M1-201 SPARE X X X X ON 2:M2-76 SPARE X X X ON 2:M2-201 SPARE X X X X ON J Q g 2:111-77 SPARE X X X X ON 2:M1-202 SPARE X X X X off 2:M2-77 SPARE X X X X °N 2:M2-202 SPARE X X X X o" W CC 2 2:M1-78 SPARE X X X X oN 2:M1-203 SPARE X X X X X o" 2:M2-78 SPARE X X X X °N 2:M2-203 SPARE X X X X_X ON (j'J Q w 2:M1-79 SPARE XXXX X ON 2:M1-204 SPARE X X X X ON 2:M2-79 SPARE XXXX X ON 2:M2-204 SPARE X X X X ON > J I- -I ° To 2:111-80 SPARE X X ON 111-205 3RD FLR CORR C3COR11 X X X X X ON 2:112-80 SPARE X X °" 2:M2-205 SPARE X X X X X ON ¢ Q 2:111-81 SPARE X X X oN 111-206 3RD FIR CORR C3COR1 XXX X X ON 2:112-81 SPARE X X X ON 2:M2-206 SPARE XXX X X ON `� + w 0 I E 2:M1-82 SPARE X X X °N 2:M1-207 SPARE XXXX X X ON 2:M2-82 SPARE X X X ON 2:M2-2D7 SPARE X X X X X X °" W > _ °' 2:M1-83 SPARE X X X X ON 2:M1-208 SPARE X X X ON 2:M2-83 SPARE X X X X ON 2:M2-208 SPARE X X X O" < J J g tli 2:111-84 SPARE X X X ON 212 :111 209 SPARE X X X X ON 2:112-84 SPARE X X X ON 2:112-209 SPARE X X X X O" 2:111-85 SPARE X X X X ON 2:M1-210 SPARE X X X X ON 2:M2-85 SPARE X X X X ON 2:M2-210 SPARE X X X X ON is 2:M1-86 SPARE X X X X ON • M1-211 3RD FLR CORR C3COR8E X X X X X ON 2:M2-86 SPARE X X X X ON 2:M2-211 SPARE X X X X X ON o 0 F 2:111-87 SPARE X X X X X oN 2:M1-212 SPARE X X X X ON 2:M2-87 SPARE X X X X X oN 2:M2-212 SPARE X X X X ON 3 < 2:141-88 SPARE X X X o" M1-213 3RD FLR O.R. #1 X X X X X ON 2:M2-88 SPARE X X X aN 2:112-213 _ SPARE X X X X X o" 2:M1-89 SPARE X X X X oN M1-214 3RD FIR SUB STERILE X X X X X ON 2:M2-89 SPARE X X X X ON 2:M2-214 SPARE X X X XX ON L.. 2:M1-9D SPARE X XX X a" M1-215 3RD FLR CORR C3COR8E XXX X XX ON 2:M2-90 SPARE X XX X ON 2:112-215 SPARE XXX X X X oN -;, 2:M1-91 SPARE X X X X _X as 2:M1-216 SPARE XX X X a" 2:M2-91 _ SPARE X X X X X ON 2:M2--216 SPARE X X X X °N a S 2:111-92 SPARE X X X X ON M1-217 3RD FIR SURGERY SUPPORT X .XX X X oN 2:M2-92 SPARE X X X -X °" 2:112-217 SPARE X X X X X °N 2:M1-93 SPARE X X X X X ON 2:M1-218 _ SPARE X X X X X ON 2:M2-93 SPARE X X X X X ON 2:112-218 SPARE X X X X X ON W S 2:M1-94 SPARE XXXX X ON _ M1-219 3RD FIR CORR C3COR10 XX XX X X ON 2:M2-94 SPARE XXXX X ON 2:M2-219 SPARE X X X X X X OH - cc 2:M1-95 SPARE XXXXX X ON M1-220 3RD FIR O.R. 14 3033 XXX V X X °" 2:M2-95 SPARE XXXXX X ON 2:M2-220 SPARE XXX X X o" 2:111-96 SPARE X X oN M1-221 3RD FLR STORAGE X XXX X X a" 2:M2-96 SPARE X X ON 2:M2-221 SPARE X XXX XX si 2:M1-97 SPARE X X X ON M1-222 3RD FIR STORAGE XX X X X X O" 2:M2-97 SPARE X X X as 2:M2-222 SPARE XXXX X X o" _ 2:111-98 SPARE X X X ON . . M1-223 3RD FLR SUB STERILE 3036 XXXXX X X O" 2:M2-98 SPARE X X X ON 2:M2-223 SPARE XX X X X X X aN 2:111-99 SPARE X X X X ON -27,,' -2./. M1-224 3RD FLR CORR C3COR10 X X X O" 2:M2-99 SPARE X X X X ON 2:M2-224 SPARE X X X ON Si LU 2:M1-100 SPARE X X X ON 2:M1-225 _SPARE X X_X X aN 2:M2-100 SPARE X X X ON 2:M2-225 SPARE X XXX " J 2:M1-101 SPARE X X X X ON M1-226 3RD FLR EVS X X X X aN 2:M2-101 SPARE X X X X aN 2:M2-226 SPARE X X X X ON 2:M1-102 SPARE XX _ X X °N M1-227 3RD FLR CORR C3COR8E X X X X X ON 2:M2-102 SPARE X X X X ON 2:M2-227 SPARE X X X X X ON 2:111-103 SPARE XXX XX °N M1-228 3RD FLR O.R. #2 X X X X oN2:112-103 SPARE XXX X X oN 2:M2-228 SPARE X XXX °" 2:X1-104 SPARE X X X O" :-s.!,,X M1-229 3RD FLR VESTIBULE 3070 X X X X X oN 2:M2-104 SPARE X X X ON 2:112-229 SPARE X X X X X ON V m 2:111-105 SPARE X X X X ON 2:M1-230 SPARE XX XXX ON 2:M2-105 SPARE X X X X ON 2:M2-230 SPARE X X X X X aNCi w 2:M1-106 SPARE X X X X ON 2:M1-231 SPARE X X X X X X ON 2:M2-106 SPARE X X X X 2:M2-231 SPARE X X X X X X ON S ON < 2:M1-107 SPARE X X X X X ON 2:M1-232 SPARE X X X X ON 2:M2-107 SPARE X X X X X ON 2:M2-232 SPARE X X X X ON ce) 2:111-108 SPARE X X X X ON 2:111-233 SPARE X X XXX ON 2:M2-108 SPARE X X X X ON 2:M2-233 SPARE X X X X X o" 3 Ja co 2:M1-109 SPARE X X X X X O" ;<, M1-234 3RD FIR SURGERY SUPPORT X X X X XON 2:M2-109 SPARE X X X X X oN 2:M2-234 SPARE X X X X X oN i oU' a g 2:M1-110 SPARE XXX XX " -23. M1-235 3RD FLR E.T.O. X X X X X X oN 2:M2-110 SPARE XXX X X °N 2:M2-235 SPARE X X X X X X oN 2:M1-111 SPARE XXXX XX ON ,;-2.3 M1-236 3RD FLR O.R. #3 X X X X X oN 2:M2-111 SPARE XXXX XX ON 2:M2-236 SPARE XX XXICON rn 2:M1-112 SPARE XXX ON is F'-. .. -... M1-237 3RD FLR OFFICE X XX X X X o" 2:M2-112 SPARE XXX ON 2:M2-237 SPARE X XX X X X oN o ,E 2:111-113 SPARE X XXX °N I/ M1-238 3RD FLR STAIRWELL XXX XXX " 2:M2-113 SPARE X XXX ON 2:112-236 SPARE XXX X X X " - V 2:111-114 SPARE _X X X X ON M1-239 3RD FLR O.R. WATER FLOW XXXX X X X ON 2:M2-114 SPARE X X X X ON 2:142-239 SPARE XXXX X X X o" m 2:M1-115 SPARE X X X X X ON M1-240 3RD FIR O.R. TAMPER SWITCH X X X X ON 2:M2-115 SPARE XX XX X ON 2:M2-240 SPARE X X X X_ON 2:M1-116 SPARE X X X X °N 2:M1-241 SPARE X XXXX " _ 2:M2-116 SPARE X X X X O" 2:M2-241 SPARE X X X X X ON ¢ 2:111-117 SPARE X X X X X ON 2:M1-242 SPARE X X X X X ON 2:112-117 SPARE X X XXX O" 2:112-242 SPARE X X X X X O" Q E co 2:M1-118 SPARE XX XXX ON 2:M1-243 SPARE XX XXXX ON 2:M2-118 SPARE XX XXX oN 2:M2-243 SPARE X X X X X XON ti Lu iiizi 2:111-119 SPARE XXX XXX ON 2:111-244SPARE X XX X X oN 2:112-119 SPARE XXX XX X °N 2:M2-244 SPARE X XXXX ON 2:M1-120 SPARE X XXX oN M1-245 3RD FIR WEST CORR AT WEST STAIRS X X X X X X oN 2:M2-120 SPARE X X X X ON 2:M2-245 SPARE X X X X X X ON 6 ' ro 2:M1-121 SPARE X X XXX ON 2:M1-246 SPARE XX X XXX " 2:M2-121 SPARE X XXX X ON 2:M2-246 SPARE XX X X X X ON CO 2:M1-122 SPARE X X XXX ON 2:M1-247 SPARE XXX X X X X oN 2:M2-122 SPARE X XXXX ON 2:M2-247 SPARE XXX X X X X o" = a N 2:M1-123 SPARE XX XXXX ON 2:M1-248 SPARE XX 2:M2-123 SPARE X X XXXX o" 2:M2-248 SPARE X XXXX " N 2:111-124 SPARE X X XXX ON 2:M1-249 SPARE X X X X X X ON 2:M2-124 SPARE XXXX X ON 2:M2-249 SPARE X X X X X X oN o 2:M1-125 SPARE X XX XXX ON 2:M1-250 SPARE X, X X X X X ON 2:M2-125 SPARE X XXXX X ON 2:M2-250 SPARE _ X X X X X X oN w NOTE : THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES. NOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES, NOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES. NOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES. 0 Z THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS. THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS. THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS. THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS. E ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING. ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING. ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING. ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING. DRAWN BY: D. R. FRIDAY Ed g POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES. POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES. POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES. POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES. CHECKED BY: N. S. WILTSIE g ISSUE DATE: 11/23/15 JOB#: .c PROJECT#: 419:989473101 $ 2 om SIMPLEXGRINNELL© 2016 i s SYSTEM: � ' FIRE ALARM SYSTEM 8 6 SHEET: _ogo SW NODE 2 FACP ',71 o CALCULATIONS e g N_ 0) m K W g WLO it U 0 R Q U m FA-soy ,,,, . 2E