HomeMy WebLinkAboutA16-0005_FA606_1477928640.pdf ..,,,,,s_......_00,,,,„ ,a.,. ,... illielJ 4 E LO Vail Fire&Emerge�Liery ca- 10/31/16 0 0 2 cry"' ie cn 0 El 'I, 2 ' c VAIL VALLEY MEDICAL CENTER-WEST WING 3RD FLR 4100es FACP Speaker Db Loss Calculations z g *Circuit Voltage = 25vrms [Et] MAXIMUM -3 dB DROP 2 m Total Total Wire Est. Ckt.i Wire Res. Circuit Speaker Speaker Voltage Watts Actual Max Allowable Plan Speaker Speaker Speaker Spkrs Watts Gauge Length Per Foot Resistance Current Resistance At End At End dB Loss Ckt. Length SPEAKER CIRCUIT DESCRIPTION Circuit Tap Tap Tap per [P] [D] in [Rw] [RI=2D*Rw] [I=P/Et] [Rs=Et/I] [Es=(Et*Rs) [Pe=(Es) [dB=Log10 [ML=(0.414*Rs) E Amp # Number .5 Watt 1. Watt 2. Watt Circuit Feet /(Rs+RI)1 *2/Rs1 (Pe/P)*101 /(2*Rw)] 1801884 j E 3RD FLR WEST WING WEST Amp-1 2:51 4 3 5 12 15. Watts 18ga 696 0.0078 10.816 0.600 41.667 19.848 9.455 -2. db 1110 Ft. ¢ o m 3RD FLR WEST WING NORTH Amp-1 2:52 7 1 8 4.5 Watts 18ga 487 0.0078 7.568 0.180 138.889 23.708 4.047 -.46 db 3700 Ft. 0�4 3RD FLR WEST WING SOUTH Amp-1 2:S3 14 2 16 9. Watts 1890 753 0.0078 11.702 0.360 69.444 21.395 6.591 -1.35 db 1850 Ft. as ycoM 4TH FLR WEST WING NORTH Amp-1 2:S4 13 3 16 9.5 Watts 1890 641 0.0078 9.961 0.380 65.789 21.713 7.166 -1.22 db 1753 Ft. o5 s 4TH FIR WEST WING SOUTH Amp-1 2:55 8 2 10 8. Watts 18ga 566 0.0078 8.796 0.320 78.125 22.470 6.463 -.93 db 2081 Ft. a 0 c 4TH FIR WEST WING CENTER Amp-1 2:S6 15 15 7.5 Watts 18ga 686 0.0078 10.660 0.300 83.333 22.165 5.895; -1.05 db 2220 Ft. � " Wqq V� Oj r New 4 cc ce G .--QUI i a i 11:3 4141ii m fk O 1 E1....:% t Cur 11% 3...: a Pill CZ vJ y0 N CU C.') VAIL VALLEY MEDICAL CENTER-WEST WING 3RD FLR - EPS-1 CIRCUIT SUMMARY & VOLTAGE DROP VAIL VALLEY MEDICAL CENTER-WEST WING 3RD FLR - EPS-2 CIRCUIT SUMMARY & VOLTAGE DROP ° Alarm Unit Wire Spare Spare Alarm Unit Wire Spare Spare g Channel Description Current % Drop Load* Length Current VoltageDrop4. Channel Description Current % Drop Load* Length Current VoltageDrop o 2:A2:1 4TH FLR WEST WING NORTH 2.066A 1.21% 29 1,025 31% 94% 2:A1:1 3RD FLR WEST WING WEST 1.353A 2.40% 20 696 55% 88% �� re sem. 2:A2:2 4TH FLR WEST WING SOUTH 1.417A 0.67% 24 1,004 53% 97% !�� 4 o 2:A1:2 3RD FLR WEST WING NORTH 0.768A 1.27% 15 462 74% 94% 24 880 55% 69% 1! * I ' r 2:A2:3 4TH FLR W WING CENTER 1.361A 6.43% 2:Al:3 3RD FLR WEST WING SOUTH 1.316A 2.00% 24 753 _ 56% 90% j / r/ ! a q -. ' '', E 2:A2: ENHANCED POWER SUPPLY - CHANNEL 1 SWITCH SETTINGS 7_9_ s�(�f�",. !!r +� 09 x IDNac Number Device Type PID Candela Custom Label (Max 40 Characters) 1 -� ie'SA ��aill./ 2A , 2:1-1 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR8 X ON 'el 2A2:1-2 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR8 X ON t 2Al: ENHANCED POWER SUPPLY - CHANNEL 1 SWITCH SETTINGS 2A2:1-3 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR8 X X ON IDNac Number Device Type PiD Candela Custom Label (Max 40 Characters) 2:A2:1-4 SV 49SV-APPLC , 75cd 4TH FLR CORRIDOR C4COR13 X ON 2:A1:1-1 SV 49SV-APPLC 75cd 1:1-1 3RD FIR CORRIDOR C3COR2 X ON 2A2:1-5 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR14 X X ON 2:A1:1-2 SV 49SV-APPLC 75cd 1:1-2 3RD FLR CORRIDOR C3COR2 X ON 2A2:1-6 SIRS 4906-9204 75cd 4TH FLR LOCKERS 4091 X X ON 2A1:1-3 SV 49SV-APPLC 75cd 1:1-3 3RD FLR CORRIDOR C3COR2 X X ON 2A2:1-7 VO 59VD-WWF 75cd 4T1-1 FIR ADA TLT 4091B X X X ON Q 2A1:1-4 SV 495V-APPLC 75cd 1:1-4 3RD FLR BREAK DOWN 3058 X ON 2A2:1-8 SIRS 4906-9204 75cd 4TH FLR IT WORKSTATIONS 4095 X ON 2:A1:1-5 SV 49SV-APPLC 75cd 1:1-5 3RD FLR SPD DIRTY SIDE 3054 X X _ ON 2:A2:1-9 STRB 4906-9204 75cd 4TH FIR SURGICAL LAB 4092 X X ON '6 2A1:1-6 SV 495V-APPLC 75cd 1:1-6 3RD FLR SPD CLEAN SIDE 3060 X X ON 2:A2:1-10 VO 59VO-WWF 3Dcd 4TH FLR IN-VITRO 4093 X X ON s 2A1:1-7 SV 49SV-APPLC 75cd 1:1-7 3RD FIR SPD CLEAN SIDE 3060 X X X ON 2:A2:1-11 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR13 X X X ONce 2:A1:1-8 SV 49SV-APPLC 30cd 1:1-8 3RD FIR STERILE CASE CARTS 3071 X ON 2:A2:1-12 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR15 X X ON g 2A1:1-9 SV 49SV-APPLC 30cd 1:1-9 3RD FLR STERILE CASE CARTS 3071 X X ON 2A2:1-13 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR15 X X X ON 2A1:1-10 STRB 4906-9204 75cd 1:1-10 3RD FLR VESTIBULE 3070 X X ON 2.02:1-14 STRB 4906-9204 75cd 4TH FIR MACHINE SHOP 4102 X X X ON 3 2A1:1-11 VO 59V0-WWF 75cd 1:1-11 3RD FIR TLT/SHWR 30426 X X X ON 2:A2:1-15 STRB 4906-9204 75cd 4T1-1 FIR TESTING LAB 4098 X X X X_ ON is 2A1:1-12 SV 49SV-APPLC 75cd 1:1-12 3RD FLR CORRIDOR C3COR8 X X ON 2A2:1-16 STRB 4906-9204 30cd 4T1-1 FIR BME(6) 4097 X ON 2A1:1-13 VO 59V0-WWF 75cd 1:1-13 3RD FLR MENS LOCKERS 3041 X X X ON 2:A2:1-17 VO 59VD-WWF 75cd 4TH FLR COOR(12) 4110 X X ON 2M:1-14 VO 59VD-WWF 75cd 1:1-14 3RD FIR TLT/SHWR 3041A X X X ON 2:A2:1-18 SV 49SV-APPLC 30cd 4TH FIR CORRIDOR C4COR13 X X ON y 2A1:1-15 VO 59VO-WWF 75cd 1:1-15 3RD FIR WOMEN'S LOCKERS 3042 XXXX ON 2:A2:1-19 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR16 X X X ON 2A1:1-16 VO 59VD-WWF 75cd 1:1-16 3RD FLR TLT/SHWR 3042A X ON 2:A2:1-20 SV 49SV-APPLC 30cd 4T1-1 FLR BOARD ROOM/ LIBRARY 4109 X X ON w f 2A1:1-17 SV _ 49SV-APPLW 75cd 1:1-17 3RD FIR STAFF LOUNGE 3043 X X ON 2:A2:1-21 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR17 X X X ON 2:A1:1-18 VO 59V0-WWF 75cd 1:1-18 3RD FIR OR STAFF EDUCATOR 3045 X X ON 2:A2:1-22 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR17 X X X ON 2:A2: ENHANCED POWER SUPPLY - CHANNEL 3 SWITCH SETTINGS IDNac Number Device Type Custom Label40 Characters) 1 - 2:A1:1-19 VO 59VO-WWF 75cd 1:1-19 3RD FLR CONFERENCE 3046 X X X ON 2:A2:1-23 SV 49SV-APPLC 30cd 4TH FLR ELEV-7 ELEVATOR LOBBY XXX X ON (Max( s 2A1:1-20 SV 49SV-APPLC 30cd 1:1-20 3RD FIR CORRIDOR C3COR9 X X ON 2:A2:1-24 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR1 X XW - ON 2A2:3-1 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR2 X ON0. 241: ENHANCED POWER SUPPLY - CHANNEL 3 SWITCH SETTINGS2:A2:3-2 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR7 X ON 4 2:A2:1-25 SV 49SV-APPLC 75cd 4TH FLR SUBWAIT M4SW X X X ON IDNac Number Device Type Custom Label (Max 40 Characters) 2:A2:1-26 VO 59V0-WWF 75cd 4TH FIR SUBWAIT M4SW X X X ON 2:A2:3-3 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR10 X X ON = o 2:A1:3-1 SV _ 49SV-APPLC 75cd 1:3-1 3RD FLR CORRIDOR X ON 2:A2:1-27 STRB 4906-9204 75cd 4TH FIR FIN. COUNS. 4003 X X X X ON 2A2:3-4 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR2 X ON 0 2:3:3-2 SV 49SV-APPLC 15cd 1:3-2 3RD FLR STORAGE ALCOVE M3A X ON 2:A2:1-28 VO 59V0-WWF 30cd 4TH FIR CHECK-OUT 4002 X X X ON 2A2:3-5 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR6 X X ON a.. 0 2:.01:1 Notification SLC Distributed Load Voltage Drop 2:A1:3-3 V0 59VD-WWF i5cd 1:3-3 3RD FLR PATIENT ILI 3009 X X ON 2.02:1-29 STRB 4906-9204 75cd 4TH FIR SUPPORT/SIG BILLING 4104 X X X X ON 2:A2:3-6 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR11 X X ON 15 2.01:3-4 SV 49SV-APPLC 75cd 1:3-4 3RD FLR CORRIDOR C3COR3 X ON 2:A2:3-7 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR5 X X X ON ' ' t Starting Voltage: 29vdc 2:A1:3-5 VO 59VO-WWF 75cd 1:3-5 3RD FLR PAT.TLT 3013 X X ON 2.02:3-8 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR2 X ON a Min. Device Voltage:y Primary Wire Gauge: t a 2.01:3-6 VQ 59VD-WWF 75cd 1:3-6 3RD FLR STAFF TLT 3025 X X DN 2 A2;; Notification SLC Distr buted Load Voltage Drop 2.02:3-9 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR3 X X oN o 9 23.vdc ry 9 Wire Res. Per Ft. 0.0031 75' Celsius 2A1:3-7 SV 49SV-APPLC 75cd 1:3-7 3RD FLR CORRIDOR C3COR4 X X X ON 2.02:3-10 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR2 X X ON Allowable % Drop: 20,7% Home Run Wire Gauge: 14ga Wire Res. Per Ft. 0.0031 CP 75' Celsius 2:A1:3-8 SV 49SV-APPLC 75cd 1:3-8 3RD FLR CORRIDOR C3COR4 X ON Starting Voltage: 29vdc 2:A2:3-11 VO 59VD-WWF 75cd 4TH FIR PAT TLT 4060 X X X ON Class B Calculations 2:A1:3-9 SV 49SV-APPLC 75cd 1:3-9 3RD FIR CORRIDOR C3COR5 X X ON Min. Device Voltage: 23.vdc Primary Wire Gauge: 14ga Wire Res. Per Ft. 0.0031 0 75' Celsius 2:A2:3-12 VO 59V0-WWF 75cd 4TH FLR PAT TEl 4059 X X ON Distance Device Current Voltage Voltage % Vdrop 2A1:3-10 SV 49SV-APPLC 75cd 1:3-10 3RD FLR CORRIDOR C3COR6 X X DN Allowable % Drop: 20.7% Home Run Wire Gauge: 14ga Wire Res. Per Ft. 0.0031 0 75' Celsius 2A2:3-13 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR12 X X X ON = Branch Device # From (Feet) PID Candela Draw at Device Drop at Device Wire Length 2A1:3-11 STRB 4906-9204 75cd 1:3-11 3RD FLR CONSULTATION 3003 X X X ON 2:A2:3-14 VO 59VD-WWF 75cd 4TH FLR SUBWAIT 4061 X X X ON L 1 2:1a-1 PANEL 65 49SV-APPLC 75cd 0.0590 0.973 0.388 28.612 Branch 1: 2.4% 2A1:3-12 VO 59VO-WWF 75cd 1:3-12 3RD FIR STAFF TLT 3025 X X ON Class B Calculations 2.02:3-15 STRB 4906-9204 75cd 4TH FIR X-RAY CTRL 4063 XXXX ON 1 1 1 1 TAP1 2A1:1-1 19 JBOX 0.0000 0.914 0.107 28.505 Length: 696 2A1:3-13 VO 59VD-WWF 75cd 1:3-13 3RD FIR PATIENT TEl 3028 X X X ON Distance Device Current Voltage Voltage % Vdrop 2A2:3-16 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR9 X ON ■ ■�� o 2A1:3-14 SV 49SV-APPLC 75cd 1:3-14 3RD FIR CORRIDOR C3COR6 X X X ON Branch Device # From (Feet) PID Candela Draw at Device Drop at Device Wire Length 2A2:3-17 STRB 4906-9204 75cd 4TH FLR MD STAFF 4083 X X ON 1 2:A1:1-2 TAP1 25 49SV-APPLC 75cd 0.0590 0.545 0.084 28.421 2Al:3-15 SV 49SV-APPLC 75cd 1:3-15 3RD FIR CORRIDOR C3COR6 XXXX ON 1 2A2:1-1 PANEL 165 495V-APPLC 75cd 0.0590 0.059 0.060 28.940 Branch 1: 1.21% 2:A2:3-18 STRB 4906-9204 75cd 4TH FLR MD STAFF 4082 X X ON 4 i 241:1-3 2.01:1-2 38 49SV-APPLC 75cd 0.0590 0.203 0.047 28.374 2:1:3-16 SV 49SV-APPLC 75cd 1:3-16 3RD FIR CORRIDOR C3COR7 X ON 1 2:A2:1-2 N2A2:1-1 35 49SV-APPLC 75cd 0.0590 0.059 0.013 28.928 - Length: 1025 2:2:3-19 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR9 X X X ON .E 1 TAP2 2:A1:1-7 27 JBOX 0.0000 0.349 0.058 28.359 2:2:3-20 STRB 4906-92Q4 75cd 4TH FLR MD STAFF 4082 X X ON a 2A1:3-17 SV 49SV-APPLC 75cd 1:3-17 3RD FLR CORRIDOR C3COR7 X X ON 1 2'2:1'-3 N2:A2:1-2 35 49SV-APPLC 75cd 0.0590 0.059 0.013 28.915 w 1 2.01:1-4 TAP2 31 49SV-APPLC 75cd 0.0590 0.059 0.011 28.348 2A1:3-18 SV 495V-APPLW 30cd 1:3-18 3RD FIR CORRIDOR C3COR1 X X ON2A2:3-21 STRB 4906-9204 75cd 4TH FIR MD STAFF 4069 X X X ON g 1 2.02:1-4 N2A2:1-3 24 49SV-APPLC 75cd 0.0590 0.059 0.009 28.906 1 2A1:1-5 TAP2 22 49SV-APPLC 75cd 0.1450 0.145 0.020 28.3392.02:3-22 STRB 4996-9204 75cd 4TH FLR COPY ROOM 4089.0 X X x ON U 1 1 20:1-6 TAP2 27 49SV-APPLC 75cd 0.1450 0.145 0.024 28.335 2A1:3-19 SV 49SV-APPLC 75cd 1:3-19 3RD FIR CORRIDOR X X X ON 1 2A2:1-5 N2:2:1-4 21 49SV-APPLC 75cd 0.0590 D.059 0.008 28.899 1 2.01:1-7 TAP1 39 49SV-APPLC 75cd 0.1450 0.369 0.088 28.417 2:1:3-20 VO 59VO-WWF 75cd 1:3-20 3RD FIR STAFF TLT 3006 X X ON 1 2A2:1-6 N242:1-5 23 4906-9204 75cd 0.0600 0.060 0.008 28.890 2.02:3-23 5V 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR9 XXX X oN = cn2.01:3-21 SV 49SV-APPLC 75cd 1:3-21 3RD FIR CORRIDOR C3COR1 X X X ON 1 2A2:1-7 N2:A2:1-6 17 59VO-WWF 75cd 0.0310 0.031 0.003 28.887 2:A2:3-24 SV 49SV-APPLC 3Dcd 4TH FLR CORRIDOR C4COR12 X X ON -� E 3 1 2:A1:1-8 2:1:1-7 51 49SV-APPLC 30cd 0.4824 0.224 0.070 28.347 a 1 2.01:1-9 2.01:1-8 35 49SV-APPLC 3Dcd 0.0820 0.142 9.031 28.316 2.01:3-22 VO 59VD-WWF 75cd 1:3-22 3RD FLR FAMILY TLT 3002 X X X ON 1 2A2:1-8 N2A2:1-5 29 4906-9204 75cd 0.0600 0.060 0.011 28.876 []e 02:1:3-23 SV 495V-APPLC 30cd 1:3-23 3RD FLR GREETER M3G X X X ,X ON 1 2:A2:1-9 N2:A2:1-5 38 4906-9204 75cd 0.1800 0.180 0.042 28.834 121 > w co 1 2.01:1-10 2.01:1-9 36 4906-9204 75cd 0.0600 0.060 0.013 28.303 2:Al:3-24 SV 495V-APPLW 75cd 1:3-24 3RD FIR CORRIDOR C3COR1 X X ON 1 2A1:1-11 2A1:1-12 19 59V0-WWF 75cd 0.0310 0.031 0.004 28.366 1 2:2:1-10 N2:A2:1-9 32 59VD-WWF 3Dcd 0.0440 0.044 0.009 28.826 I- c. `m 1 2.01:1-12 2.01:1-2 30 49SV-APPLC t5cd 0.0590 0.283 0.052 28.369 1 2:A2:1-11 N2A2:1-4 43 49SV-APPLC 75cd 0.0590 0.059 0.016 28.810 z it 1 2A1:1-13 2A1:1-12 25 59VD-WWF 75cd 0.0310 0.062 0.010 28.360 1 TAP1 N2:2:1-11 17 JBOX 0.0000 0.141 0.015 28.795 w j § 1 2:1:1-14 2.01:1-131 2:A2:1-12 TAP7 20 49SV-APPLC 75cd -25 59VD-WWF 75cd 0.0310 0.031 0.005 28.355 0.0590 D.059 0.007 28.788 U E ti g 1 2A1:1-15 2A1:1-12 23 59V0-WWF i5cd 0.0310 0.062 0.009 28.361 1 2.02:1-13 N2A2:1-12 35 49SV-APPLC 75cd 0.0590 0.059 0.013 28.775 1 2A1:1-16 2A1:1-15 27 59VD-WWF 75cd 0.0310 0.031 0.005 28.355 1 2:A2:1-14 N2A2:1-13 36 4906-9204 75cd 0.1800 0.180 0.040 28.736 ¢ 0 15 `� 1 2A2:1-15 N2A2:1-16 25 4906 9294 75cd 0.1800 0.180 0.028 28.708 8 3 1 2A1:1-17 2A1:1-12 44 49SV-APPLW 75cd 0.1000 0.100 0.027 28.342 2A1:3 Distributed Load Voltage Dropr" 1 2A2:1-16 N2:A2:1-12 24 4906-9204 30cd 0.0920 0.092 0.014 28.694 2: 2.3 Distributed Load Voltage Drop C) 00 g �, 1 TAP3 2.01:1-3 i 1 JBOX 0.0000 0.144 0.010 28.364 Q O 1 2.01:1-18 TAP3 26 59VD-WWF 75cd 0.0310 0.031 0.005 28.359 Starting Voltage: 29vdc 1 2:A2:1-17 N2:A2:1-13 28 59VO-WWF 75cd 0.0310 0.031 0.005 28.689 1 2A2:1-18 TAP1 37 49SV-APPLC 30cd 0.0820 0.082 0.019 28.777 StartingVoltage: CE _ 1 2:1:1-19 TAPS 21 59VD-WWF 75cd 0.0310 0.113 0.015 28.350 Mia. Device Voltage: 23.vdc o Primary Wire Gauge: 14-ga Wire Res. Per Ft. 0.0031 0 75' Celsius 9 29vdc w 0 O 3 Allowable % Dro Home Run Wire Gauge: 1 a 1 2.02:1-19 N2A2:1-18 29 49SV-APPLC 75cd 0.0590 O.D59 0.011 28.756 Min. Device Voltage: 23.vdc Primary Wire Gauge: 14ga Wire Res. Per Ft. 0.0031 ® 75' Celsius J Q y 1 2A1:1-20 2A1:1-19 30 49SV-APPLC 30cd 0.0820 0.082 0.015 28.335 p: 20.7% 9 4g Wire Res. Per Ft. 0.0031 0 75' Celsius = 1 2.02:1-20 N2A2:1-19 35 49SV-APPLC 30cd 0.0820 0.082 0.018 28.748 _ ___ Allowable % Drop:-20,7% Home Run Wire Gauge: 14ga Wire Res. Per Ft. 0.0031 ® 75' Celsius iJ,J Class B Calculations 1 2A2:1-21 N2A2:1-18 34 495V-APPLC 75cd _ 0.0590 0.059 _ 0.012 28.736 t Y' 2A1: ENHANCED POWER SUPPLY - CHANNEL 2 SWITCH SETTINGS Volta a Volta e 1 2A2:1-22 N2A2:1-21 30 49SV-APPLC 75cd 0.0590 0.059 0.011 28.725 Class B Calculations W Distance Device Current 9 9 Branch a) IDNac Number Device Type Custom Label40 Characters 1 # ( ) Dro % Dro 1 2:A2:1-23 N2:A2:1-22 38 49SV-APPLC 3Dcd 0.0820 0.082 0.019 28.706 Distance Device Current Voltage Voltage Branch J 0 = (Max( ) Branch Device From Feet PID Candela Draw at Device p at Device P g U 2:A1:2-1 SV 495V-APPLC 30cd 1:2-1 3RD FLR CORRIDOR C3CORl1 X ON 1 2:A1:3-1 PANEL 48 49SV-APPLC 75cd 0.0590 0.368 0.108 28.892 Branch 1: 0.85% 1 2:A2:1-24 N2:A2:1-23 40 49SV-APPLC 75cd 0.0590 0.059 0.014 28.692 _---_. Branch Device i� From (Feet) PID Candela Draw at Device Drop at Device % Drop CJ) 2:A1:2-2 SV 49SV-APPLC 75cd 1:2-2 3RD FLR CORRIDOR C3COR8E X ON 223 1 2:A2:1-25 N2A2:1-24 33 49SV-APPLC 75cd 0.0590 0.059 0.012 28.680 i 2:.02:3-1 PANEL 177 49SV-APPLC 75cd 0.0590 1.361 1.479 27.521 Branch 1: 6.43% J Q W Co 1 2:1:3-19 241:3-1 34 49SV-APPLC 75cd 0.0590 0.309 0.065 28.827 Length: + �„� 2:A1:2-3 SPARE X X ON 1 2:A2:1-26 N2:A2:1-25 29 59VD-WWF 75cd 0.0310 0.031 _ 0.006 28.674 1 TAP4 2.02:3-1 12 JBOX 0.0000 1.302 0.096 27,425 Length: 880 > _ E 1 2A1:3-20 2:A1:3-19 24 59V0-WWF 75cd 0.0310 0.031 0.005 28.822LJJ 2A1:2-4 SV 495V-APPLC 75cd 1:2-4 3RD FLR CORRIDOR C3COR9 X ON 1 242:1-27 N2A2:1-26 24 4906-9204 75cd 0.0600 0.060 0.009 28.665 1 2:A2:3-2 TAP4 30 49SV-APPLC 75cd 0.0590 0.059 0.011 27.414 --J _J s 1 2.01:3-21 2.01:3-19 30 49SV-APPLC 75cd 0.0590 0.219 0.040 28.787 2A1:2-5 SV 49SV-APPLC 75cd 1:2-5 3RD FIR CORRIDOR C3COR9 X X ON 1 2.01:3-22 2A1:3-21 25 59V0-WWF 75cd 0.0310 0.031 0.005 28.782 1 2A2:1-28 N242:1-25 24 59VO-WWF 30cd 0.0440 0.044 0.006 28.659 1 2:A2:3-3 TAP4 30 49SV-APPLC 75cd 0.0590 0.618 0.114 27.311 > Q Q 7 > 2:A1:2-6 STRB 4906-9204 75cd 1:2-6 3RD FIR OR #3 & #4 SCRUB X X1 2:2:1-29 N2:A2:1-22 25 4908-9204 75cd 0.0600 0.060 0.009 28.650 1 2:A2:3-4 TAP4 34 49SV-APPLC 75cd 0.0590 0.059 0.012 27.413 a 1 2:A1:3-23 2.01:3-21 32 49SV-APPLC 3Dcd 0.0820 0.129 0.025 28.761 > "- WI 2:A1:2-7 SV 49SV-APPLC l5cd 1:2-7 3RD FLR CORRIDOR C3COR10 X X X ON 1 TAPS TAP4 29 JBOX 0.0000 0.566 0.101 27.324 7 241:3-24 2.07:3-23 30 49SV-APPLW 75cd 0.0470 0.047 0.009 28.753 _ o, 2:A1:2-8 VO 59VO-WWF 75cd 1:2-8 3RD FLR TLT/SHWR 3079A X ON 1 2:42:3-5 TAP5 30 49SV-APPLC 75cd 0.0590 0.059 0.011 27.313 2 2:A1:3-2 PANEL Si 49SV-APPLC 75cd 0.0590 0.917 0.343 28.657 Branch 2: 2% o 241:2-9 VO 59VD-WWF 30cd 1:2-9 3RD FLR SURG LOCKERS WOMENS 3079 x x 2 2A1:3-18 2Ai:3-2 19 49SV-APPLW 30cd 0.0570 0.057 0.007 28.650 Length: 530 2:A2: ENHANCED POWER SUPPLY - CHANNEL 2 SWITCH SETTINGS 1 2:42:3-6 TAPS 30 49SV-APPLC 75cd 0.0590 0.059 0.011 27.313 1- 2A1:2-10 VO 59VO-WWF 3Dcd 1:2-10 3RD FLR SURG LOCKERS MEN'S 3078 X X ON IDNac Number Device Type Custom Label (Max 40 Characters) 1 1 TAPE TAP5 31 JBOX 0.0000 0.448 0.085 27.239 2 241:3-3 2A1:3-2 15 59VO-WWF 75cd 0.0310 0.031 0.003 28.654 d 2:A1:2-11 VO 59V0-WWF 75cd 1:2-11 3RD FIR TLT/SHWR 3078A X X X oN 2 TAP5 2A1:3-2 8 JBOX 0.0000 0.770 0.038 28.619 2.02:2-1 VO 59VD-WWF 75cd 4TH FLR STAFF LOUNGE 4950 x 1 2:A2:3-7 TAPE 30 49SV-APPLC 75cd 0.0590 0.059 0.011 27.228 ® is J 2A1:2-12 VO 59VO-WWF 3Dcd 1:2-12 3RD FLR SURG LOCKERS MEN'S 3078 X X DN 2A2:2-2 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR4 X ON 2 2A1:3-4 TAPS 28 49SV-APPLC 75cd 0.0590 0.384 0.066 28.553 1 2:A2:3-8 TAPE 17 49SV-APPLC 75cd 0.0590 0.177 0.018 27.220 F L 2A1:2-13 SV 49SV-APPLC l5cd 1:2-13 3RD FIR STORAGE HALL X X X ON 2: 1 TAP7 2:.02:3-8 25 JBOX 0.0000 0.118 0.018 27.202 2 2A1:3-5 241:3-4 21 59VO-WWF 75cd 0.0310 0.062 0.008 28.545 42:2-3 VO 59VO-WWF 75cd 4TH FLR STAFF TLT 4059 X X ON 1 2A1:2-14 SV 49SV-APPLW 75cd 1:2-14 3RD FLR STORAGE X X X ON 2 2A1:3-6 2.01:3-5 16 59VO-WWF 75cd 0.0310 0.031 0.003 28.542 2:A2:2-4 STRB 4906-9204 75cd 4TH FIR MD STAFF 4048 -x _ ON 1 2:A2:3-9 TAP7 30 49SV-APPLC 75cd 0.0590 0.059 0.011 27.191 - E g 2A1:2-15 VO 59VD-WWF 75cd 1:2-15 3RD FLR STORAGE XXXX ON 2.02:2-5 STRB 4906-9204 75cd 4TH FLR MD STAFF 4447 X X ON 2 2:Al:3-7 2A1:3-4 36 49SV-APPLC 75cd 0.0590 0.263 0.058 28.495 1 2:A2:3-10 TAP7 20 49SV-APPLC 75cd 0.0590 0.059 0.007 27.195 2:1:2-16 SV 49SV-APPLC 75cd 1:2-16 3RD FLR CORRIDOR C3COR8E X 2.02:2-6 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR3 X X 1 2:42;3-11 TAPE 21 59VO-WWF 75cd 0.0310 0.062 0.008 27.231 2 2.01:3-8 2:1:3-7 48 49SV-APPLC 75cd 0.1450 0.204 0.060 28.434 2.02;2_7 STRB 4906-9204 75cd 4TH FLR MD STAFF 4046 XXX ON 2 2:1:3-9 2A1:3-8 36 49SV-APPLC 75cd 0.0590 0.059 0.013 28.421 1 2:42:3-12 2:42:3-11 21 59V0-WWF 75cd 0.0310 0.031 0.004 27.227 2 2:41:3-10 TAP5 33 49SV-APPLC 75cd 0.0590 0.386 0.078 28.541 2A2:2-8 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR6 X a 1 2:.02:3-13 TAP6 30 49SV-APPLC 75cd 0.0590 0.150 0.028 27.211 2.01:2 VoltageDrop 2 2.01:3-11 2:41:3-10 26 4906-9204 75cd 0.0600 0.060 0.010 28.531 242:2-9 SIRS 4906-9204 75cd 4TH FLR MD STAFF 4045 X X - oN o Distributed Load 1 2:A2:3-14 2:A2:3-13 26 59VD-WWF 75cd 0.0310 0.031 0.005 27.206 2 2:.01:3-12 2:41:3-10 26 59VD-WWF 75cd 0.0310 0.031 0.005 28.536 242:2-10 STRB 4906 9204 75cd 4TH FIR MD STAFF 4044 x X 1 2:42:3-15 2:42:3-13 16 4906-9204 75cd 0.0600 0.060 0.006 27.205 f) Storting Voltage:_29vdc 2 2:A1:3-13 2:A1:3-14 22 59VO-WWF 75cd 0.0310 0.031 0.004 28.487 2:A2:2-11 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR6 X X X ON 1 TAPS 2:A2:3-3 15 JBOX 0.0000 0.559 0.051 27.260 Min. Device Voltage: Primo Wire Gauge: 14 a 2 2:Al:3-14 2A1:3-10 34 49SV-APPLC 75cd 0.0590 0.236 0.049 28.491 2:A2:2-12 SV 49SV-APPLC 75cd 4TH FLR CORRIDOR C4COR5 X X ON `° 9 23.vdc Primary 9 9 Wire Res. Per Ft. D.D031 ® 75' Celsius 1 2.02:3-1fi TAPE 18 49SV-APPLC 75cd 0.0590 0.179 4.020 27.240o Allowable % Drop: Home Run Wire Gauge: 1 a2 241:3-15 2A1:3-14 33 49SV-APPLC 75cd 0.0590 0.177 0.036 28.455 2:A2:2-13 STRB 4906-9204 75cd 4TH FLR MD STAFF 4033 X X X ON c p 20.7% 9 49 Wire Res. Per Ft. 0.0031 0 75' Celsius 1 2:.02:3-17 2:.02:3-16 19 4906-9204 75cd 0.0609 0.120 0.014 27.226 LL 2 2.01:3-16 241:3-15 33 49SV-APPLC 75cd 0.0590 0.118 0.024 28.431 2:42:2-14 VO 59VO-WWF 75cd 4TH FIR CONFERENCE 4036 XXX - 1 2:A2:3-18 2A2:3-17 23 4906-9204 75cd 0.0600 0.060 0.008 27.217 (7) 2 2A1:3-17 2:A1:3-16 35 49SV-APPLC _ 75cd 0.0590 0.059 0.013 28.419 2A2:2-15 STRB 4906-9204 75cd 4TH FLR MD STAFF 4034 XXXX ON o Class B Calculations 1 2:.02:3-19 TAPS 31 49SV-APPLC 75cd 0.0590 0.389 0.072 27.187 J Voltage Voltage 2A2:2-16 SV 49SV-APPLC 75cd 4TH FIR CORRIDOR C4COR4 X ON Distance Device Current 9 9 Branch 1 2.02:3-20 2A2:3-19 26 4906-9204 75cd 0.0600 0.180 0.029 27.159 2.02:2-17 5V 49SV-APPLC 75cd 4TH FLR CORRIDOR C4CQR4 X X oN i Branch Device # From (Feet) PID Candela Draw at Device Drop at Device % Drop 1 2:A2:3-21 2A2:3-20 22 4906-9204 _ _75cd _0.0600 0.120 0.016 27.142 m Z 2A2:2-18 SV 495V-APPLC 75cd 4TH FLR CORRIDOR C4COR4 X X 1 2:42:3-22 2:.02:3-21 20 4906-9204 75cd 0.0600 0.060 0.007 27.135 c 1 241:2-1 PANEL 32 49SV-APPLC 3Dcd 0.0820 0.768 0.151 28.849 Branch 1: 1.27% s 1 TAPS 241:2-1 17 JBOX 0.0000 0.296 0.031 28.818 Length: 462 2:42:2-19 SIRS 4906-9204 75cd 4TH FLR MED STAFF 4016 X X X ON 1 2:A2:3-23 2A2:3-19 35 49SV-APPLC 75cd 0.0590 0.141 0.030 27.157 1 m 1 2:A1:2-2 TAP3 38 49SV-APPLC 75cd 0.0590 0.237 0.055 28.763 2.02:2-2D STRB 4906-9204 75cd 4TH FLR MED STAFF 4018 X X ON 1 2:A2:3-24 2:A2:3-23 32 49SV-APPLC 30cd 0.0820 0.082 0.016 27.141 y o 1 2A1:2-4 2A1:2-2 37 49SV-APPLC 75cd 0.0590 0.178 0.040 28.722 2A2:2-21 5V 495V-APPLC 110cd 4TH FIR WAITING 4006 X_ X X ON 2 j 1 2-A1:2-5 2A1:2-4 39 49SV-APPLC 75cd 0.0590 0.119 0.028 28.694 2.02:2-22 VO 59VO-WWF 7 5cd 4TH FIR PUBLIC WOMENS 4008 X X X ON E r¢ 2:A2:2-23 VO 59V0-WWF 7 5cd 4TH FIR PUBLIC MENS 4007 X X X X ON 1 2Al:2-6 241:2-5 25 4906-9204 75cd 0.0600 0.060 0.009 28.685 I- 1 TAP4 2.01:2-1 11 JBOX 0.0000 0.390 0.026 28.823 2A2:2-24 SV 49SV-APPLW 30cd ROOF ELEV-5 MACHINE ROOM X X ON zz 1 2.01:2-7 TAP4 24 49SV-APPLC 75cd 0.0590 0.315 0.046 28.776 o_ 1 2.01:2-8 TAP4 18 59VO-WWF 75cd 0.0310 0.075 0.008 28.814 v .. 1 2:M:2-9 2:41:2-8 20 59VD-WWF 30cd 0.0440 0.044 0.005 28.809 cn 1 2A1:2-10 2A1:2-7 21 59VD-WWF 30cd 0.0440 0.256 0.033 28.743 _ Q 1 2:1:2-11 2A1:2-10 38 59VO-WWF 75cd 0.0310 0.212 0.049 28.694 _ 1 241:2-12 2:1:2-11 19 59V0-WWF 3Dcd 0.0440 0.181 0.021 28.673 Y .o 1 2.01:2-13 2:41:2-12 22 495V-APPLC 75cd 0.0590 0.137 0.019 28.654 2:.02:2 Distributed Load Voltage Drop 1 2A1:2-14 2A1:2-13 33 49SV-APPLW 75cd 0.0470 0.078 0.016 28.6387 o Starting Voltage: 29vdc 1 2A1:2-15 2A1:2-14 37 59VO-WWF 75cd 0.0310 0.031 D.007 28.631Q Min. Device Voltage: 23.vdc Primary Wire Gauge: 14ga Wire Res. Per Ft. 0.003110 75' Celsius 0 Q 1 241:2-16 TAP3 31 49SV-APPLC 75cd 0.0590 0.059 0.011 28.807 Allowable % Drop:-20.7% Home Run Wire Gauge: 14ga Wire Res. Per Ft. 0.0031 ,® 75' Celsius 0.0000 0.000 0.000 0.000 0 co LU Co Class B Calculations S Distance Device Current Voltage Voltage Branch c.7 'o Branch Device # From (Feet) PID Candela Draw at Device Drop at Device % Drop 2 € 1 2:A2:2-1 PANEL 182 59VO-WWF 7 5cd 0.0310 0.031 0.035 28.965 Branch 1: 0.67% w Yo 1 2:A2:2-2 N2:A2:2-1 24 49SV-APPLC l5cd 0.0590 0.059 0.009 28.957 Length: 815 vii ¢ o oV 1 2A2 :2-3 N2:A2:2-2 20 59VO-WWF 75cd 0.0310 0.031 0.004 28.953 � (NJ 1 2:A2:2-4 N2:A2:2-3 17 4906-9204 75cd 0.0600 0.060 0.006 28.947 0 1 2:42:2-5 N2:A2:2-2 23 4906-9204 75cd 0.0600 0.060 0.008 28.938 F. a 1 _TAP2 N2:A2:2-2 15 JBOX 0.0000 0.118 0.011 28.927 w 1 2:A2:2-6 TAP2 21 49SV-APPLC 75cd 0.0590 0.059 0.008 28.920 z 1 2:A2:2-7 N2:A2:2-6 25 . 4906-9204 75cd 0.0600 0.060 0.009 28.910 DRAWN BY: D. R. FRIDAY E 1 TAP3 N2:A2:2-6 16 JBOX 0.0000 0.118 0.012 28.899 CHECKED BY: N. S.WILTSIE a1 2:A2:2-8 TAP3 15 49SV-APPLC 75cd 0.0590 0.059 _ 0.005 28.893 rISSEJE DATE: 11/23/15 1 2:42:2-9 N2:A2:2-8 22 4906-9204 75cd 0.0600 0.060 0.008 28.885 1 2:.02:2-10 N2:A2:2-8 36 4906-9204 75cd 0.0600 0.060 0.013 28.872 JOB#: - 1 2:42:2-11 TAP3 27 49SV-APPLC 75cd 0.0590 0.059 0.010 28.889 8 1 2:A2:2-12 N2A2:2-11 33 49SV-APPLC 75cd 0.0590 0.059 0.012 28.877 PROJECT#: 419:9894731 D1 o m 1 2:A2:2--13 N2A2:2-12 21 4906-9204 75cd 0.0600 0.060 0.008 28.869 SIMPLEXGRINNELL Oc 2016 i 1 1 2:42:2-14 N2:A2:2-12 25 59V0-WWF 75cd 0.0310 0.031 0.005 28.865 SYSTEM: 2 E 1 2A2:2-15 N2:A2:2-12 28 4906-9204 75cd 0.0600 0.060 0.010 28.854 1 2:A2:2-16 TAP2 29 49SV-APPLC 75cd 0.0590 0.059 0.011 28.917 FIRE ALARM SYSTEM 6 6 1 2:42:2-17 142:42:2-16 48 49SV-APPLC 75cd 0.0590 0.059 0.017 28.899 1 1 2:.02:2-18 142:A2:2-17 47 495V-APPLC 75cd 0.0590 0.059 0.017 28.882 SHEET: .N g1 2A2:2-19 142:42:2-18 30 4906-9204 75cd 0.0600 0.060 0.011 - 28.871 h 1 2A2:2-20 N242:2-19 21 4906-9204 75cd 0.0600 0.060 0.008 28.864 E i 1 2A2:2-21 N2:A2:2-18 42 49SV-APPLC 110cd 0.1930 0.193 0.050 28.814 NODE 2 FACP ._ .G 1 2:42:2-22 N2:A2:2-21 35 59VD-WWF 75cd 1 0.0310 0.031 0.007 28.807 0 0, 1 2A2:2-23 N2:42:2-22 13 59V0-WWF 75cd 0.0310 0.031 0.002 28.805 CALCULATIONS a 2 2A2:2-24 PANEL 189 495V-APPLW 30cd 0.0570 0.057 0.066 28.934 Branch 2: 0.23% o a) mo N W (1J WE 43 m 10 m LU v U N FA-606 N V C G X E O m