HomeMy WebLinkAboutA16-0027_223A FA000_1478896332.pdf � ' z 4 LEGEND : o. , FRY i.. j � 4 SYMBOL DEVICE MANUFACTURER/PART# MOUNTING ; � •,] ffE1�' FACP Honeywell Vista-128BPT (5.-k.,-q, . ' .p Vail Hirre e s Emergency lervices 05Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox g[3• '. toe.__„ v i 0; 352331 KP 1..,..;;p. a:': I LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox µ .* •,w;• Combination Smoke 8c �-.`51NS/OVALS, 223 BEAVER DAM, UNIT A Heat Detector w/Sounder System Sensor i3 series 4WTA—B 4" square box Ademco Vista 128 FACP StandbyCombination Smoke and Number of Current Total Current ()co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box Device Type Devices (Amps) (Amps) Main FACP CPU 1 X 0.032 = 0.032 O System Sensor 5601 P 4193SN Serial Interface 1 X 0.00015 = 0.00015 Heat Detector w/4193SN Addressable module 4" square box COSMOD4W Module 3 X 0.052 = 0.156 i3 Smoke Detector 4 X 0.0005 = 0.002 E Cosmo Interface Module COSMOD4W i4 Smoke/CO Detector 8 X 0.0005 = 0.004 6160 Keypad 1 X 0.04 = 0.04 SUM COLUMN FOR STANDBY LOAD 0.23415 = AMPS KB Knox Box Alarm Load o Number of Current Total Current ,0, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox Device Type Devices (Amps) (Amps) Main FACP CPU 1 X 0.032 = 0.032 4193SN Serial Interface 1 ' X ' 0.00015 = 0.00015 COSMOD4W Module 3 X 0.075 = 0.225 GENERAL NOTES: o i3 Smoke Detector 4 ' X 0.035 = 0.14 i= i4 Smoke/CO Detector 8 X 0.04 = 0.32 a_ 6160 Keypad 1 X 0.1 = 0.1 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN o Outside Horn/Strobe 1 X 0.195 = 0.195 ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE o SUM COLUMN FOR ALARM LOAD 1.01215 = AMPS DEPARTMENT REQUIREMENTS AND NFPA 72. z Standby Load Required Standby Time in Hours 2. REFER TO MANUFACTURERS DATA SHEETS AND Current (Amps) INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION 5w 0.23415 X 24 = 5.62 Alarm Load Required Alarm Time in Hours REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Current (Amps) (15 MINUTES) PROGRAMMING AND DEVICE OPERATION. _ 1.01215 X 0.25 = 0.25 Add Standby and Alarm Load for Required ui Ampere Hour Battery 5.87 0 Multiply by the Derating Factor of 1,2 Total Ampere Hours Required = 7.05 Batteries Provided: 12AH Minimum d z 0 N g .70 O 0SEQUE\CE OF w Q10 approved as noted . . . OPERATIO\S: 0 J Q Qz z zz O— _ .� O JLLI cO O O CT) O z 0 — U � o Z E z W Q N Q -i i- •— 0 O op Q O O c N W N D z 18 >. Q _ U 1 (� O. (� O C 7 O co o vi U z � QE � E � E � m V) co Ta Li_ m0 cno cno cno U O ° n ` 73 XO ami � � mel cn DEVICE > > o z - z - z - > zz >z v ) } a I X DESCRIPTION a a a - - _ � o i_ o � o - O - - (/) a a Q < F- < (.„ < . O o CC SMOKE DETECTOR X X X 2 N. •.0 Q •�Iur�INi• _ RD IW 1��• z HEAT DETECTOR X X X 40 I- O z 0 CARBON MONOXIDE DETECTOR X X N- SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X op CO CD 1- PROJECT I \ FOVAT ON : rn 223 3EAVE � DAV , U \ IT A o VAIL COLOA3O rn w F RE ALAS V SYSTE V u) 0 D = 4—WIRE DATA/POWER, 4—#16AWG (2 PAIR) 0 C X = 2—WIRE DATA, 2—#16AWG EOL EOL AHJ: VAIL FIRE 8c EMERGENCY SERVICES Z W O O APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 Q O z N = 2—WIRE SOUNDER CIRCUIT, 2—#18AWG Q FULLY SPRINKLERED ~ Ct _ Z = 2—WIRE DATA CIRCUIT, 2—#16AWG D D Z CJS U KP = KEYPAD CIRCUITING, 4—#18AWG FIRE ALARM SYSTEM FOR DUPLEX UNIT. SYSTEM INCLUDES NEW D 0 LLI = RISER NOTES: CO0 CO0 ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE J Q DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE Q W Ct 1. REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE 0 J 0 MORE INFORMATION. N 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS L, PROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. HEAT DETECTORS D CO MANUFACTURERS SPECIFICATIONS. E L,N 11J [El WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO 0 = LU 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (NP) (NP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE PRIOR TO INSTALLATION. WIRING DIAGRAM isZ O HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM INCLUDED SUBMITTAL BOOKS. SYSTEM. Q Q CL O m 120VAC DEDICATED POWER VISTA 128FPB Z W O ~ CONTROL PANEL FLOW SWITCH J U Z TAMPER SWITCH Q OQ Z TELEPHONE LINE — FIRE W 0 TELEPHONE LINE — SECURITY BELL N oWP FIRE PROTECTION ENGINEER: m I— CD OUTPUT ,O, EOLR DEBORAH SHANER, P.E., SHANER LIFE SAFETY co J Z PO BOX 1073, PRISCO CO 80443 N _.=,... 0 W DATA/COM KP I ICV > 0 10 ISE D AG AfV OUTPUT KEYPAD KEYPAD PHONE: 970-409-9082' FAX: 970-797- 1898 SHEET DESCRIPTION: FIRE ALARM PLAN DRAWN BY: DATE: DLS 4/12/16 SHEET#: A: FA-0.00