HomeMy WebLinkAboutA16-0012_FA000_1456510140.pdf 1214061 OF z ec LEGEND : _FRY 4,.... -NOY O SYMBOL DEVICE MANUFACTURER/PART# MOUNTING ; •,0 ILEI,/' 1. FACP Honeywell Vista-128BPT d.. U IG4. <.p 2/26/1esEmergency:ervices Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox1 tw.n 1,13523 a KP ivoi %-. :F . a:'::,1 ;` LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox µ .* •,w;• Combination Smoke 8c �.ASIONAL°, Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box Combination Smoke and ()co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box 1226 WESTHAVEN UNIT #1 Ademco Vista 128 FACP 0 System Sensor 5601 P Standby Heat Detector w/4193SN Addressable module 4" square box Number of Current Total Current Device Type Devices (Amps) (Amps) E Cosmo Interface Module COSMOD4W Main FACP CPU 1 X 0.032 = 0.032 41935N Serial Interface 3 X 0.00015 = 0.00045 COSMOD4W Module 3 X 0.052 = 0.156 KB Knox Box i3 Smoke Detector 6 X 0.0005 = 0.003 14 Smoke/CO Detector 6 X 0.0005 ' = 0.003 o 6160 Keypad 2 X 0.04 = 0.08 ,0, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox SUM COLUMN FOR STANDBY LOAD 0.27445 = AMPS Alarm Load Number of Current Total Current z Device Type Devices (Amps) (Amps) GENERAL NOTES: o Main FACP CPU 1 X 0.032 = 0.032 o_ 4193SN Serial Interface 3 X 0.00015 = 0.00045 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN E COSMOD4W Module 3 X 0.075 = 0.225 ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE o i3 Smoke Detector 6 X 0.035 = 0.21 DEPARTMENT REQUIREMENTS AND NFPA 72. .i4 Smoke/CO Detector 6 X- 0.04 ' = 0.24 0 6160 Keypad 2 x 0.1 = 0.2 2. REFER TO MANUFACTURERS DATA SHEETS AND Outside Horn/Strobe 1 x 0.195 = 0.195 INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION w SUM COLUMN FOR ALARM LOAD 1.10245 = AMPS REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Standby Load Required Standby Time in Hours PROGRAMMING AND DEVICE OPERATION. _ Current (Amps) 0.27445 X 24 = 6.59 Alarm Load Required Alarm me in Hours 1- m Ti Q Current (Amps) (15 MINUTES) 0 1.10245 X 0.25 = 0.28 Add Standby and Alarm Load for Required Ampere Hour Battery 6.86 0 Multiply by the Derating Factor of 1.2 Total Ampere Hours Required = 8.23 Batteries Provided: 12AH Minimum CN CO CO 0 J 0 ZONE LIST S E Q U E\C E OF Qfy w V) cz J Z � '� O ch ZONE # DESCRIPTION OP E R AT 10\S: _ 1 SPRINKLER WATERFLOW Lu 0 o 0 z 0 ( o z > U 2 SPRINKLER TAMPER 0° z •w Q N Q w Q o •� O 0 0 3 LOWER LEVEL CO DETECTION Q o D N w N °z° N Z w ±"..., >, Q C9 0 4 LOWER LEVEL SMOKE DETECTION z Q (/) m o x C ' `t, CO 0 vi a_ LI7 5 MAIN LEVEL CO DETECTION 6 MAIN LEVEL SMOKE DETECTION o o o 0 0 o m 7 UPPER LEVEL CO DETECTION rx 1- 0 z 0 La O cC'3 cn Mo X $ UPPER LEVEL SMOKE DETECTION DEVICE > j o z z z j �z 5z - 9 GARAGE HEAT DETECTOR DESCRIPTION E 1 _ g o g o g o i o o o ?Xl: o o 10 SYSTEM TROUBLE Q Q ~ " ~ ~ ~ ~ < N Q = O o SMOKE DETECTOR X X X _z HEAT DETECTOR X X X 40 F- O z 0 CARBON MONOXIDE DETECTOR X X co SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X oo CO CD 1- PROJECT I \ FOVATON : rn 1226 WESTHAVE\ , U \ T # 1 0 VAIL COLOA3O rn w F RE ALAS V SYSTE V u) D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) 0 C X = 2-WIRE DATA, 2-#16AWG EOL EOL AHJ: VAIL FIRE & EMERGENCY SERVICES z W O O APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 O Z N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWGCt Q FULLY SPRINKLERED _ Z = 2-WIRE DATA CIRCUIT, 2-#16AWG D D U C1) KP = KEYPAD CIRCUITING, 4-#18AWG FIRE ALARM SYSTEM FOR DUPLEX UNIT. SYSTEM INCLUDES NEW w = RISER NOTES: CO0CO0ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE J Q DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE - w Ct 1. REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE J OO MORE INFORMATION. L,N E L,N PROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. HEAT DETECTORS .. D w 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS CO MANUFACTURERS SPECIFICATIONS. E [El WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO Z = 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (TYP) (TYP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE w O H 121 PRIOR TO INSTALLATION. WIRING DIAGRAM IS O HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM Q Q INCLUDED SUBMITTAL BOOKS. Ct SYSTEM. _ 0 m 120VAC DEDICATED POWER VISTA 128FPB Z I- O I- CONTROL PANEL FLOW SWITCH (n J 0 ID Z TAMPER SWITCH w 0 w < Z TELEPHONE LINE - FIRE U TELEPHONE LINE - SECURITY BELL N ,,--)/VP FIRE PROTECTION ENGINEER: ., I- CD OUTPUT ,O, EOLR DEBORAH SHANER, P.E., SHANER LIFE SAFETY CO J Z PO BOX 1073, PRISCO CO 80443 N Q O W DATA/COM KP I IN- U Q ISE D AG AIV OUTPUT KEYPAD KEYPAD PHONE: 970-409-9082' FAX: 970-797- 1898 SHEET DESCRIPTION: FIRE ALARM PLAN DRAWN BY: DATE: DLS 2/16/16 SHEET#: FA-0.00