Loading...
HomeMy WebLinkAboutA16-0013_FA000_1456510200.pdf tattli OF go.. z L_E G E\ D . FRY ... o , _ 0 10 SYMBOL DEVICE MANUFACTURER/PART# _ MOUNTING r `o R • r � i' :? ��I r e +�t`G "r. Vail 2/2Fii1e&Emergency lervices FACP Honeywell Vista-128BPT it ;�m: Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox �� 3523 a v ',,,%-..,,.,0.. %- ? . i " `u.., 1226 WESTHAVEN UNIT#2 KP " * LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox •••••••Y.*- Ademco Vista 128 FACP A4NAt- " - Standby Combination Smoke & Number of Current Total Current 0 Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box Device Type Devices (Amps) (Amps) Main FACP CPU 1 X 0.032 = 0.032 Combination Smoke and 4193SN Serial Interface 3 X 0.00015 = 0.00045 ®co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box COSMOD4W Module 3 X 0.052 = 0.156 - -i3 Smoke Detector 4 X 0.0005 ' = 0.002 O System Sensor 5601 P 14 Smoke/CO Detector 5 X 0.0005 = 0.0025 Heat Detector w/4193SN Addressable module 4" square box 6160 Keypad 2 X 0.04 = 0.08 SUM COLUMN FOR STANDBY LOAD 0.27295 = AMPS cE Cosmo Interface Module COSMOD4W Alarm Load Number of Current Total Current KB Device Type Devices (Amps) (Amps) Knox Box Main FACP CPU 1 X 0.032 = 0.032 4193SN Serial Interface 3 X 0.00015 = 0.00045 0 COSMOD4W Module 3 X 0.075 = 0.225 ,O, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox 13 Smoke Detector 4 X 0.035 = 0.14 .14 Smoke/CO Detector 5 .X 0.04 _ = 0.2 6160 Keypad 2 X 0.1 = 0.2 z Outside Horn/Strobe 1 X 0.195 = 0.195 GENERAL NOTES: SUM COLUMN FOR ALARM LOAD 0.99245 = AMPS E Standby Load Required Standby Time in Hours 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN w Current (Amps) ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE 0 = 0.27295 X 246.55 DEPARTMENT REQUIREMENTS AND NFPA 72. o z Alarm Load Required Alarm Time in Hours i-n Current (Amps) (15 MINUTES) 2. REFER TO MANUFACTURERS DATA SHEETS AND 5 0.99245 X 0.25 = 0.25 INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION Add Standby and Alarm Load for Required REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Ampere Hour Battery 6.80 PROGRAMMING AND DEVICE OPERATION. " Multiply by the Derating Factor of 1.2 Total Ampere Hours Required = 8.16 I- Batteries Provided: 12AH Minimum Q 0 d ZONE LIST z ZONE # DESCRIPTION oo 1 SPRINKLER WATERFLOW CO .70 2 SPRINKLER TAMPER O 3 LOWER LEVEL CO DETECTION 0 Q 4 LOWER LEVEL SMOKE DETECTION SEQUENCE OF z J w V) ° fya 5 MAIN LEVEL CO DETECTION o Q o . O M 6 MAIN LEVEL SMOKE DETECTION Q z r z OZ x 0 76 o 7 UPPER LEVEL CO DETECTION 0 0 �n o Reviewed and approved . Jo z0 8 UPPER LEVEL SMOKE DETECTION 0° z w cn Q V) Q w Q 0 `� > E '�� >, < o 9 GARAGE HEAT DETECTOR o o p u) w u) m Z w o) v " 10 SYSTEM TROUBLE Paper copyofpermitO2 S- 2 22 m w � LI7 CO co C� Z ‹ E (n - - pp o X required to be posted w w . wo � X 1 0 w cn a DEVICE Q Q D z z z _ Q a Q }o - 0 DESCRIPTION Q Q Q (/) et a� 0 0 = a- O a- O a- O o O o O O o Q Q � I- I- i- I- i- I- Qcn Q = CC SMOKE DETECTOR X X X ••• I • 40:6* *•SIB• Z • 40 H HEAT DETECTOR X X X H0 z 0 co N- CARBON MONOXIDE DETECTOR X X X SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X co M 1- d- PROJECT I \ FOVAT O \ : a' 1 226 WESTHAVE\ , U \ IT #2 o w VAIL COLORADO o_ FRE ALAN SYSTEM v C D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) - W X = 2-WIRE DATA, 2-#16AWG What does L stand for? EOL EOL AHJ: VAIL FIRE 8c EMERGENCY SERVICES Z Z just curious. 0 0 APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 O Q N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG CL � Z = 2-WIRE DATA CIRCUIT, 2-#16AWG N D D FULLY SPRINKLERED N 0 KP = KEYPAD CIRCUITING, 4-#18AWG W = # \ �l FIRE ALARM SYSTEM FOR DUPLEX UNIT. SYSTEM INCLUDES NEW J Q RISER NOTES: �co vco ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE W 1 DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE Z 1 . REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE D J 03 O _I 0 MORE INFORMATION. 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS a, L,N K L,N PROVIDED WITHIN 15 OF FUEL BURNING APPLIANCES. HEAT DETECTORS Z = W MANUFACTURERS SPECIFICATIONS. [c7 WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO W 0 H CI 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (NP) (NP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE > 0 - - INCLUPRIOR TO INSTALLATION. WIRING DIAGRAM IS Z O HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM < < O m INCLUDED SUBMITTAL BOOKS. SYSTEM. _ 120VAC DEDICATED POWER VISTA 128FPB Z U) 0 U W O < CONTROL PANEL FLOW SWITCH W Z Z TAMPER SWITCH TELEPHONE LINE - FIRE U i- CD TELEPHONE LINE - SECURITY BELL N oWP FIRE PROTECTION ENGINEER: co J Z OUTPUT ,O, EOLR DEBORAH SHANER, P.E., SHANER LIFE SAFETY N Q 0 WISE DATA/COM KP I I I PO BOX 1073, FRISCO, CO 80443 N- > U S E AG SAV OUTPUT KEYPAD KEYPAD PHONE: 970-409-9082 FAX: 970-797- 1898 SHEET DESCRIPTION: FIRE ALARM PLAN DRAWN BY: DATE: DLS 2/16/16 SHEET#: FA-0.00