Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A16-0035_FA-002_1478896351.pdf
tatit:1 OF go. , ,a:%5 . . . • ,,, .._... , ow i,„ , 4. „.. .. III GE\ E �AL \ OTES SYSTEV 3ESC RT O \ / SCODE CF WORK SYV3OL KEY S E Vail Fir_&Emerg��Se vies 06/1 /13 �n co 1\ oo M M CO M E a CO M OCCUPANCY TYPE: R-2 RESIDENTIAL GROUP I 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF A� CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLED ,Y 1:11 -1141 a< % SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR FIRE A_ARM SYMBOLS LEGEND eilk8, DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES, RELOCATE AND DEMO EXISTING TO IMPAIR THE CONSTRUCTION SCHEDULE. DEVICES AS SHOWN ON DRAWINGS. COMMONLY USED BACKBOX, REFER '� 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING SYMBOL DESCRIPTION M O D E L# a� o�„o AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY ALL NEW WIRING TO BE CLASS B. TO DATA SHEET FOR OTHER OPTIONS ,,o AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. SMOKE SENSOR, WITH CO SENSOR BASE SIMPLEX 4098-9714 goo ,,----,_4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE 8Co SIMPLEX 4098-9773 BASE 4" OCTAGONAL BOX 1 1/2" DEEP :M INSTALLATION. WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO 520Hz 2 s6 SB = 520HZ SOUNDER i (2Lu Lu 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. L: I- oo5 BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE c c ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE CONDO UNIT #677: �]S SPEAKER ONLY, WALL MOUNT SIMPLEX 4902-9717 4" SQUARE BOX 1 1/2" DEEP W/ 1 1/2" RING PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. THE SCOPE OF WORK TO INCLUDE THE REMODEL OF THE 6TH FLOOR CONDO UNIT #677. FOUR #W = SPEAKER TAP **USE 70 VOLT TAP** W/4905-9942 ADAPTER SKIRT WHEN SURFACE MOUNTED 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO EXISTING CONVENTIONAL SMOKE DETECTORS IN THE SCOPE OF WORK AREA TO BE REMOVED. FIVE SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. NEW COMBO SMOKE DETECTORS WITH CO 520HZ SOUNDER BASES WILL BE INSTALLED IN THE NEW 3 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. CONDO SPACE AS SHOWN ON THE FLOORPLAN. THE EXISTING "M2" IDNET SLC CIRCUIT AND EXISTING T4 TEMPORAL CODE 4 MODULE SIMPLEX 4905-9835 4" SQUARE BACK BOX, 2 1/8" DEEP 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. SOUNDER BASE NAC CIRCUIT IN THE 6TH FLOOR TO BE EXTENDED TO NEW SMOKE/CO SENSORS. THE 9. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF INSTALL OF FIVE NEW SPEAKER ONLY DEVICES AS_SHOWNON THE FLOORPLAN. THE EXISTING "S20" ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. END-OF-LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 `° 10. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND SPEAKER CIRCULI ON THE STH., FLOOR WILL EXTEND TO THE NEW SPEAKER ONLY_DEVICES WITHIN #K END-OF-LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH -CONDO UNIT#677. SPEAKERS WITHIN-UNIT #677 ARE PR O,VIDED TO SATISFY INTELLIGIBILITYTY END-OF-LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 MANUFACTURER'S INSTRUCTIONS AND NEC. REQUIREMENTS PER CODE. SHOULD THE SPEAKERS PROVIDE A SOUND LEVEL EITHER EXCEEDING A END-OF-LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 MAXIMUM OF 110DB OR BE DEEMED EXCESSIVE BY THE AHJ, SPEAKERS SHALL BE ADJUSTED TO 11. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). LOWER THE DB OUTPUT OR BE REMOVED ENTIRELY WITH THE APPLIANCES BACK BOX TO BE CAPPED 12. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE INTEGRITY, T- WITH AN ACCEPTABLE COVER PLATE. MAINTAIN CIRCUITTAPPING IS NOT PERMITTED. THE ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. SEQUENCE OF OPERATION WILL NOT BE CHANGED AS A RESULT OF'THIS REMODEL. ' 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE v FPLP. -�' 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN - o VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. h install . Db d for 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET Approveo LOCATIONS. 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. verification required . t 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. F R E ALA U APPLICABLE L CABLE C0 : E S & STA\ 3 A 3 S 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING x CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION ws STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. a INTERNATIONAL FIRE CODE (IFC), 2015 EDITION a NATIONAL ELECTRIC CODE (NEC), 2011 EDITION a NATIONAL FIRE ALALRM AND SIGNALING CODE (NFPA 72), 2013 EDITION 0 1 0 0 s E-_,- W HE SCHE3 ,JLE ABBEV AT O \ S LE3E\ 3 3 U 3 `o m 0 AC = ABOVE CEILING HT = HEIGHT C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING o E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM o RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM FRE ALAN WIRE LIST RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM o 6 RL = RELOCATED DEVICE N/A = NOT APPLICABLE ': CIRCUIT DESCRIPTION RISER RATED: FPLR SINGLE CONDUCTOR(THHN,TFFN) PLENUM RATED: FPLP RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER M MAPNET/IDNET CIRCUIT SG ANIX./PAIGE 740215 SG ANIX./PAIGE 740214L NDU = NETWORK DISPLAY UNIT co 1 PAIR 18 AWG TWISTED AREA=0.0196 SQ. INCH AREA=0.0196 SQ. INCH WP = WEATHERPROOF NEC = NATIONAL ELECTRICAL CODE OVERALL SHIELD ANIXTER PART NUMBER ANIXTER PART NUMBER XP = EXPLOSION PROOF NFPA = NATIONAL FIRE PROTECTION ASSOCIATION T740215 F, FAMC-1802C-1-2S-0365 H = HIGH HUMIDITY NIC = NOT IN CONTRACT S EQ L E\ C E OF OD E SAT 0 \ n AFF = ABOVE FINISHED FLOOR NPU = NETWORK PROCESSING UNIT N p POWER CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE AHJ = AUTHORITY HAVING JURISDICTION NTS - NOT TO SCALE N- 2 CONDUCTOR AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH ALM = ALARM PAP = PRE-ACTION PANEL `114 AWG SOLID (SUBSCRIPT ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER t "r" IF RESETTABLE) FA-140X-1-1N-03-BX AREA=0.0097 SQ. INCH (EACH) FA-140X-1-2N-03 ANN = ANNUNCIATOR SCC = STATUS COMMAND CENTER BMS = BUILDING MANAGEMENT SYSTEM SLC = SIGNALING LINE CIRCUIT it 22 E9 S AUDIO CIRCUIT SG ANIX./PAIGE 454703ARE SG ANIX./PAIGE 740132R CBC = CALIFORNIA BUILDING CODE SMK = SMOKE - s C 1 PAIR 18 AWG TWISTED AREA=0.0204 SQ. INCH AREA=0.0141 SQ. INCH CD = (eg. 15CD) CANDELA SUPV = SUPERVISORY Vail Lodge Tower - Sequence of Operations UNSHIELDED ANIXTER PART NUMBER ANIXTER PART NUMBER CSFM = CALIFORNIA STATE FIRE MARSHAL TAC = TRUEALERT ADDRESSABLE CONTROLLER o O FA-1802C-1-1N-03-BX FA-1802C-1-2N-03 DET = DETECTOR TRBL = TROUBLE SYSTEM OUTPUTS z o DGP = DATA GATHERING PANEL TS = TAMPER SWITCH FACP Annunciation Notification Required Supplementary s CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA EOL = END OF LINE TYP = TYPICAL g 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * EPO = EMERGENCY POWER OFFControls I- 3/4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH * UON = UNLESS OTHERWISE NOTED FACP = FIRE ALARM CONTROL PANELc 1" 0.34 SQ INCH * 2" 1.34 SQ INCH * VCC = VOICE COMMAND CENTER - FATC = FIRE ALARM TERMINAL CABINET VT O * 40% FILL PER N.E.C. FBO = FURNISHED BY OTHERS = VALVE TAMPER ti THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL FCC = FIRE COMMAND CENTER WF = WATER. 1/2W)WATT I E w 1 FM = FIRE ALARM ANNUNCIATOR W/ - WITH o CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE FTR = FIRE ALARM TRANSPONDER SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS FSD = FIRE SMOKE DAMPER W/0 • = WITH OUT o o CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT I O ct DESIGN OF THIS SYSTEM INSTALLATION. .T w w 2 REFERENCE https://www.anixter.com/customer/tycofs FOR SG ANIXTER CABLE DATA D EV C E A > > ESS \ C LEGE\ 3 o o w 0co 2 w Io .s E O ct co o c) Q Lu Q Uo Ds CNcCnE: a) cnON7noTE� moc o ' '- • o N 1-6 0 o \ a, Li_ 0 J -2 o 0) O CD o in oo o aU J C c _ o -0 0" Jli o Lav -0 cn -` 1- ADDRESSABLE CARD (IDNET OR MAPNET) 2 E -9 ' c.2 5 o r DEVICE ADDRESS N a �, c Q E0 a o ico i J - 2 o, o a) oV2- 1 o o n° E ° ° c O o o = ov Ev E E i! cc o , o CQ o N g U < U < U Q ,; o U -o -o -o -o c = 0 c E, ADDRESSABLE DEVICES NUMBERING �, cp T E E E a w W CO U) U) � � o Q CD N N E E E 7 7 Si 8 E d C C C N U U = D D D D g 0 0 0 >. SYSTEM INPUTS " " " " " " o a o 2 2 °' N N 0 0 0 0 0 -0 . °' Q Q Q Q Q a Q (A o i- i- i- = = Z Z Z Z Z i, . ABCDEF H K I JK L MNOPQ T U X Y Z 0 1 Manual Pull Station - All Locations X X X X X X 1 72 2 Smoke Sensors - All Locations X X X X X X 2 0 CIRCUIT DESIGNATOR 3 Smoke Sensor - Room Dectectors Only X X X X 3 (V=VISUAL OR , H=AUDIBLE ONLY) z /V 4 Smoke Sensor - 1st Floor Lobby X X X X X X 4 Q DEVICE ADDRESS r 5 Smoke Sensor - Elevator Lobby X X X X X X X X 5 Q6 Smoke Sensor - Elevator Machine Room X X X _ 6 V2:- 1 7 Duct Smoke Sensor X X X X X 7 co 8 I Carbon Monoxide Sensor - Alarm A A A X X 8 o ADDRESSABLE NOTIFICATION DEVICE 9 Carbon Monoxide Sensor - Trouble X X X X X 9 10 Thermal Sensors - All Locations X X X X X X 10 ci 11 Waterflow - Main X X X X X X X 11 z 3 12 Sprinkler Control Valve - X X X X 12 13 FACP AC Power Failure X X X X 13 .o 14 FACP Low Battery X X X X 140 2 SPEAKER CIRCUIT 15 Open Circuit X X X X 15 Y" DEVICE DESIGNATOR 16 Ground Fault X X X X 16 r17 Notification Appliance Circuit Short X X X X 17 (3 - . °: 18 i Alarm Signal Silence X X 18 2 S2- 1 ABCDEF H K I JK L MNOPQ T U X Y Z - NOTE: Audible Evacuation Signal shall be Temporal Pattern per NFPA 72. L, o MSPEAKER DEVICE * Disconnect power after a time delay equal to the time it takes for the car to travel from the highest to the lowest level plus 10 seconds. o * Audible Evacuation Signal shall be alert tone followed by voice direction - Speakers and Strobes will activate by area of alarm. o E (f J °3 CO * Alarm areas are room /condo tower, lodge, international wing. 3 A. Alarm shall sound within the individual living unit only and shall not actuate the building fire alarm system. c o C\1 N 0 o m m a LU i z DRAWN BY: VUK E CHECKED BY: SKS F- ISSUE DATE: 5/23/16 Q JOB#: § PROJECT#: 419:992671801 U 0 C SIMPLEXGRINNELL© 2016 E NICET CERTIFICATION SYSTEM: FIRE ALARM SYSTEM o C U (O N SHEET: i TECHNICAL AREA 00303: LEVEL 3 -N CERTIFICATE #: 83242 VALID THROUGH: 10/01/14 GENERAL INFORMATION m a En Q2 � a 0 N m o in 5/27/2016 w U) E STEVE SHARP DATE } o i L a �w � FA-002 o N V X F 'T. O d M a t