A16-0035_FA-101_1478896354.pdf
stC P71 x x x ON DRAWING NOTES: 4:N,4 M2-41 PHOTO VSMOKE M2-41 5TH FIR M1D W RESIDENTIAL CORRIDOR x x x x x LODGE TOWER 4100ES UPGRADE 4100u FACP M2 42 °HOTO VSMOKE M2-42 5TH FLR MlD W RESIDENTIAL CORRIDOR X x X x X x X X ON 1 . THE INFORMATION OR SYMBOLS N IN BOLD MO 0 Q�7 E Standby Total Alarm Total M2-45 PHOTO VSMOKE M2-45 5TH FLR MID RES/DENT/AL CORRIDOR X X x X X X X XON E LINETYPE ARE NEW. N Module Qty Description Current Standby Current Alarm M2-44 PHOTO VSMOKE M2-44 5TH FIR MID ELEVATOR LOBBY X X X X x X X XON pea Vail Fir.&Emergi.o c v s M2-45 'ROTO VSMOKE M2-45 5TH FLR MID RESIDENTIAL CORRIDOR X X X X X x X XON 1 06/13/10 0 o . Panel Equipment �. HE INrORIViATION OR SYMBOLS SHOWN IN LIGn \ Lou-) M2-46 PHOTO VSMOKE M2-46 5TH FLR EAST RESIDENTIAL CORRIDOR x X X X x X X XON ARE EXISTING. M M Z 4100 0170 2 MAPNET 4100-6005 1 MASTER CONTROLLER POWER MODULE y 0.0000 00000 0.2700 0.5400 0.0000 0.0000 LINETYPE M2-47 °HOTO VSMOKE M2-47 5TH FLR E ELEVATOR LOBBY X X X X X X X XON MM .2900 0.5800 M2-48 ADRPUI PULL M2-48 5TH FIR WEST x x x x X X x x ON 3. ALL CEILINGS ARE ASSUMED TO BE SMOOTH AND LESS 4100-5707 1 IDNET+ MODULE, UP TO 250 POINTS * 0.0750 _ 0.0750 0.1750 _ 0.1750 M2-49 SPARE X x x x x X x x ON THAN 10' IN HEIGHT. lliN z o .. a 4100-4321 5 6 CIRCUIT CLASS B (STYLE Y) 0.0250 _ 0.0750 _ 0.0700 _ 0.2100 M2 50 °HOT'' VSMOKE M2-50 6TH FLR W RESIDENTIAL CORRIDOR X x x x x x x x ON m 4100-7407 1 24 POINT I/O INTERFACE MODULE 0.0780 0.0780 0.0780 0.0780 I'12 s' u� VSMOKE M2-51 6TH FIR MID W RES/DENT/AL CORRIDOR X x X X x x X X ON 4. SHOULD THE SPEAKERS PROVIDE A SOUND LEVEL EITHER EXCEEDING A �� 4100-5125 1 REMOTE POWER SUPPLY kV/CHARGER 720VAc 0.1500 0 7500 0.1850 0.1850 o VSMOKE M2-52 6TH FIR MID w RESIDENTIAL CORRIDOR X X x x x X X XON MAXIMUM OF 110DB OR BE DEEMED EXCESSIVE BY THE AHJ, SPEAKERS M2 53 -HOTO VSMOKE M2-53 6TH FIR Mi0 RESIDENTIAL CORRIDOR X X x X x X X XON SHALL BE ADJUSTED TO LOWER THE DB OUTPUT OR BE REMOVED a , .. r, 4100-9620 1 BASIC AUDIO WITH MICROPHONE ANALOG 0.2250 0.2250 0.2250 x2250 x X x x XON ENTIRELY WITH THE APPLIANCES BACK BOX TO BE CAPPED WITH AN M2-54 ROTO VSMOKE M2-54 6TH FIR M1D ELEVATOR LOBBY xx x x Coll �� ¢ o x 4100-6052 1 EVENT REPORTING DACT 0.0500 0.0200 0.0400 0.0400 Xxx x x XON ACCEPTABLE COVER PLATE. FIRE ALARM SYSTEM DESIGNER IS NOT z V) trs = M2-55 ROTO VSMOKE M2-55 6TH FLR MID RESIDENTIAL CORRIDORx x x N o9 4100-6058 1 DUAL RS 232 IF CARD 0.7320 0.7320 0.1320 0.1320 Xxx XON RESPONSIBLE FOR PROVIDING AN ACCEPTABLE COVER PLATE. '1; _o M2-56 ROTO VSMOKE M2-56 6TH FLR EAST RESIDENTIAL CORRIDOR x x xx (� o c,.3 w 4100-1226 7 DIGITAL FLEX 50W AMP W/3 NACS - 25V 0.0850 0.0850 2.2700 2.2700 M2-57 °HOTO VSMOKE M2-57 6TH FLR E ELEVATOR LOBBY X x x x X X X XON co o s 4100-1294 1 LED/SWITCH SLIDE IN LABEL KIT 0.0000 0.0000 0.0000 0.0000 M2-58 ADRPUL PULL M2-58 6TH FIR WEST X x x x X X X XON 5. SPEAKERS ARE PROVIDED FOR PURPOSES OF DELIVERING CODE F wc,M N 4100-6079 1 SAFELINC INTERNET INTRFACE 0.1450 0.1450 0.1450 0.1450 M2-59 SPARE X X x x X X X XON REQUIRED INTELLIGIBILITY TO UNIT #677. v uu v - ooQQ • 4700-7153 1 INFOALARM 4100U UPGRADE 0.0820 00820 0.1270 0.7270 M2 79 -OTO VSMOKE M2-60 7TH FLR W RESIDENTIAL CORRIDOR X x x X X X X XON Cl)CZ Q M2-, °HOTO VSMOKE M2-61 7TH FIR MIS W RESIDENTIAL CORRIDOR X x x X X X X XON KEY NOTES: CO 3 4100-1295 _ 1 PANEL MOUNTED PRINTER 0.1250 _ 0.1250 0.8000 0.8000 - y M2-62 PHOTO VSMOKE M2-62 7TH FIR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON H 4100-1288 1 64/64 LED/SWITCH CONTROLLER 0.0200 0.0200 0.0200 0.0200 M2-62 PHOTO VSMOKE M2 63 7TH FIR MID RESIDENTIAL CORRIDOR xxxxxxxXON 01 INSTALL NEW SMOKE DETECTOR WITH COMBO m 4100-1280 2 8 SWITCH, 8 RED LED MODULE 0.0000 00000 0.0240 0.0480 X ON CARBON MONOXIDE/520HZ SOUNDER BASE. M2 64 Horo VSMOKE M2 64 7TH FIR MI5 ELEVATOR LOBBY x x x x x X x CONNECT TO EXISTING "M2" IDNET SLC CIRCUIT 1 4100-1252 7 7 CHANNEL AUDIO OPERATOR INTERFACE 0.0000 0.0000 0.0240 0.0240 M2-65 =PHOTO VSMOKE M2-65 7TH FLR MID RESIDENTIAL CORRIDOR x XXXXX x XON AND EXISTING SOUNDER BASE NAC CIRCUIT ON 6TH d100-7241 1 MESSAGE EXPANSION BOARD 8 MINUTES 0.0020 000200.0770 0.0770 M2-66 DHOTOVSMOKE M2 66 7TH FIR EAST RESIDENTIAL CORRIDOR x x XXXX x x ON FLOOR. "T4" TEMPORAL CODE 4 MODULE NAC -9600 7 REMOTE ANNUNCIATORS & MINIPLEX TRANSPONDERS RUI CURRENT DRAWS INCLUDED BELOW M2-67 SPARE X X XXXX X x ON CIRCUIT IS FROM THE FACP. Panel Totals 1.7640 5.0160 M2-68 - - PULL M2-68 7TH FIR WEST x x x x x x x X ON M2-69 SPARE X X X XXX X X X ON 0. IDNet Addressable Devices (SLC) 02 EXTEND EXISTING "S51 " SPEAKER CIRCUIT TO NEW -099-9001 /4 DN[T SINGLE ACTION PULL STATION 0.0000 00000 0.0000 00000 M2 7o ADRPUL PULL M2-70 1ST FLR EAST xxxxxxxx ON SPEAKERS IN REMODELED UNIT 677. MAINTAIN % M2-71 ADRPUL PULL M2-71 2ND FLR EAST X X X xxxx x ON CIRCUIT INTEGRITY, T-TAPPING IS NOT PERMITTED. 4090-9001 29 IDNET SUPERVISED IAM 0.0000 00000 0.0000 00000 M2-72 ADRPUL PULL M2-72 3RD FLR EAST x X X x X x x X ON 4090-9176 4 INTELLIGENT IDNET ISOLATOR MODULE 0.0000 0.0000 0.0000 0.0000 M2-75 ADRPUL PULL M2-73 4TH FIR EAST X x x x x x x x ON 4098-9714 73 TRUEALARM PHOTO SMOKE SENSOR 0.0000 0.0000 0.0000 0.0000 M2-74 ADRPUL PULL M2-74 5TH FIR EAST x x x x x x x x ON 4009-9207 7 4009 IDNET NAC EXTENDER, 120 VAC 9.0000 00000 0.0000 0.0000 M2-75 ADRPUL PULL M2-75 6TH FIR EAST X X x x x x x x ON _ 4098-9792 56 TRUEALARM SENSOR BASE 0.0000 00000 0.0000 0.0000 M2-76 ADRPUL PULL M2-76 7TH FIR EAST X X x X x x x x ON T. 0 4098-9794 11 TRUEALARM SENSOR SOUNDER BASE 0.0000 0.0000 0.0000 0.0000 M2-77 SPARE x x x x x x x x ON IL, 4098-9771 1 SSD SOUNDER BASE W/CO MODULE 0.0000 0.0000 0.0000 0.0000 M2 78 SPARE x x x x x x x x ON o - M2-79 ✓ACSPT SIGNAL M2-81 GARAGE NAC PANEL /1 X X X X x x x x ON �� 4098-9773 5 520Hz SOUNDER BASE W/ CO MODULE 0.0000 0.0000 0.0000 0.0000 M2-80 AM HEAT M2-80 GARAGE x x x x x x x x ON Mapnet Addressable Devices (SLC) M2-81 IAM HEAT M2-81 GARAGE X x x x x x x x ON • . la 90-916V IS MAPNET UNSUPERVISED CONTROL ZAM * 0.0000 0.0000 0.0000 0.0001' M2-82 IAM HEAT M2-82 GARAGE x X x x X x X x ON Ws '-9172 83 MAPNET SUPERVISED IAM * 0.0009 0.0000 0.0000 0.0000 M2-85 IAM HEAT M2-85 GARAGE X X x x X x X x ON 2009-9795 10 MAPNET SINGLE ACTION PULL STATION 0.0000 0.0000 0.0000 0.0000 M2-84 AM HEAT M2 84 GARAGE X X x X x X x XON 4098-9714 40 TRUEALARM PHOTO SMOKE SENSOR 0.0000 00000 0.0000 0.0000 M2-85 AM HEAT M2-85 GARAGE X X X X X X X X ON �� 4098-9725 13 TRUEALARM HEAT SENSOR 0.0000 0.0000 0.0000 0.0000 M2-86 HEAT M2-86 GARAGE x x X x x x x x ON IT `x M2-87 HEAT M2-87 GARAGE X X X x X x X x ON 4098-9756 7 TRUEALARM DUCT SMOKE SENSOR W/RELAY OUTPUT 0.0000 0.0000 0.0000 0.0000 68 678 - M2-88 IAM HEAT M2-88 GARAGE X X X x X x X x ON (75 rA7 I 4098-9792 53 TRUEALARM SENSOR BASE * 0.0000 0.0000 0.0000 0.0000 a M2-89 IAM HEAT M2-89 GARAGE x x x x x x x x ON ITI, - Miscellaneous Peripheral Devices That May Require System Power M2-90 AM HEAT M2-90 GARAGE x x x x x X x X ON �� STUR' NIT 4098-9845 1 ENCAPSULATED RELAY PAM-SD 0.0000 0.0000 0.0150 0.0150 M2-91 IAM HEAT M2-91 GARAGE x x x x x x x x ON I 682 T 4098-9756 1 TRUEALARM DUCT SMOKE SENSOR W/RELAY OUTPUT 0.0030 0.0020 0.0750 0.0750 M2-92 IAM HEAT M2-92 GARAGE x x x X X x x x ON 4098-9794 71 TRUEALARM SENSOR SOUNDER BASE 0.0000 0.0000 0.0200 0.2200 X x X X x ON i _,,,, M2 93 AM HEAT M2 93 GARAGE x x X X X X x x ON rATOR A 0 4098-9792 109 TRUEALARM SENSOR BASE 0.0000 0.0000 0.0000 0.0000 M2-94 IAM HEAT M2-94 GARAGE_ 4098-9771 1 SSD SOUNDER BASE W/CO MODULE 0.0000 0.0000 0.0170 0.0170 M2-95 IAM HEAT M2-95 GARAGE X X X X X x x x ON r /pr ��2190-9163 13 MAPNET UNSUPERVISED CONTROI ZAM 0.0100 01500 0.0400 0.5200 M2-96 /AM HEAT M2-96 GARAGE x X x x x x X xON x x x oNZtA4098-9773 5 520Hz SOUNDER BASE W/ CO MODULE 0.0000 0.0000 0.1290 0.6450 M297 ,ASV HEAT M2-97 SOUTH GARAGE STORAGE CLOSET/507 x x x x x ® `MI Notification AppliancesM2-98 /A7v1 HEAT M2-98 SOUTH GARAGE STORAGE CLOSET/537 x xx x x x x x oN ,,,, MTWP-2475W-FR 7 MULTI TONE BELL SETTING BELL 0.0000 0.0000 _ 0.0530 0.0530M2 99 AM HEAT M2 99 SOUTH GARAGE STORAGE CLOSET f538 xXX x X x x XoN ,'��A Peri heral Totals M2-100 /70 HEAT M2-100 SOUTH GARAGE STORAGE CLOSET/539 x x x x x xx x °N EL ATORP 0.1330 1.4850 10 ■- �■ IS,,pIA-,101W2.JdL== ° RUI Totals 1 0.0035 0.0035 M2 107 SPARE x x x x x x x x ON Address Totals 322.5 Addresses 0.2857 0.2953 M2-102 AM HEAT M2 102 GARAGE x x X X X x X x ON u 2 * M2-103 AM HEAT M2 703 GARAGE x x x x x x x x ON 1 • Current draw included under "Device Addresses Used" (See "Additional Current Dragws:") Total Standby 2.1862 _ Total Alarm 6.7998 ,'S20 1 1. 2-wire detector alarm current is included in the alarm current of the Initiatin Device Circuit. M2 104 AM HEAT M2 704 GARAGE x x X x x x x x °N , M2�576 32. Backup Amplifier assumes Main Amplifier alarm current on failure. M2-705 IAM HEAT M2-105 GARAGE xx xxxxx x °N `.�Standby Standby Alarm Alarm _ M2-706 IAM HEAT M2-106 GARAGE X x X x X x X X ON ' J I 15 0X X X X X ON / mBattery Set #1 (Cabinet/Charger #1) Current Total Current Total M2 107PHOTOVSMOKE M2 107 EAST ELEVATOR LOBBY x x x Select ALL Power Supplies on this battery set: M2 108 AM HEAT M2 108 SOUTH PARK/NG GARAGE xXx x X x x X oN / NX12 3 1 f o M2 109 AM HEAT M2 109 SOUTH GARAGE STORAGE CLOSET 506 x x x x x x x x °N M 53 S20 3 M2 55M2 6 V12 XPS-1 - 1.8970 4.2310 VA'51 F '� © r 5 0 Amp-1 0.0850 2.2700 M2-110 IAM HEAT M2-770 SOUTH GARAGE STORAGE CLOSET#207 x x X X X x X X ON 30 � IMF , S 1 ' Sub Total 1.9820 6.5010 M2-111 SPHOTO LATSUPV M2-111 UNIT 777 HALLWAY x x x x x x x x ON Amity, F _ M2-172 SPHOTO LATSUPV M2-112 UNIT 777 LIVING ROOM X X X x x X X XON 0 Additional Current Draws: r - S51-6©� m ' co RUI Connected Peripheral Devices M2 175 SPHOTO LATSUPV M2-115 UNIT 777 BED ROOM 7 x x x x ON a I S51 RETURN O o L P 1 x 0.0035 = 0.0035 x 0.0035 = 0.0035 xxx x I 25W ©COO o-O s co MAPNET/ZDNet Device Addresses ordered / used 323 x 0.000886 = 0.2857 x 0.000916 = 0.2953 M2-714 SPHOTO IATSUPV M2-114 UNIT 777 BED ROOM 2 X x X X x X X X ON 7520Hz SB II y M2-115 SPHOTO IATSUPV M2-115 UNIT 777 BED ROOM 3 X X x x X X X X ON l M2-133 ENTRY MUD KITCHEN CS) Sub Total 2.2712 6.7998 x x X X ON -0 I 4 �`---- 100 101 I _ M2-116 SPARE x x xxBATH 3 I 7 o_ - Spare addressable point capacity 20% 65 x 0.000886 = 0.0576 x 0.000916 = 0.0595 M2-117 SPARE X X X X X X X X ON 111 - a S51 t ,� Total 2.3288 6.8593 M2 178 SPARE x x X x x X X X ON \ Oo \ m co M2 119 SPARE x x x x x x x x ON O BATH 2 ❑ Standby Time = 24 Hrs x 2.3288 = 55.8908 Standby Ah M2-120 SPARE x x x x X X X x ON S51-10 S 109 CLOSET MSTR� WC ` o� x X X X x ONI 5 F!csO 1 0 106 0 BAOT5 104 O m Alarm Time = 15 Min 0.25 x 6.8593 = 1.7148 Alarm Ah M2 121 SPARE x x x '',, 25W o 57.6056 M2-122 SPARE x x x XXXX x ON S 2 520Hz 0 $ 25W Additional Spare Capacity = 20%, IM2-137 S525W© f r:t + 11.5211 M2 123 SPARE x x x x x x x x ON ___ _25W 2 1'�1 -�� I S51-7 s > 69.1267 XXXXX ON 520HzS -82;M2 724 SPARE X X x 3K o Battery Discharge Factor = 20% + 13.8253 x x x x x x x x ON S51 OI M2-136 I COO Z o M2-125 SPARE c" Minimum Battery Required 2081-9279 110AH (2x) 82.9521 M2-126 SPHOTO SMOKE M2-126 4TH FL UNIT 499 BUNKROOM x x X X X X X x ON I MSTRS51 520HzS6 Battery Supplied 2081-9296 5OAH (4) M2-127 SPHOTO SMOKE M2-127 4TH FL UNIT 499 BEDROOM 2 x x x x x x x x ON [ 103 M2-134 0 1- Battery Supplied 2081-9279 110AH (2x) M2-128 SPHOTO SMOKE M2-128 4TH FL UNIT 499 BEDROOM 1 x x x x x x x X ON UNIT BEDROOM 3 a) 16' 112 OS51-8 LIVING/DINING -a M2 129 SPHOTO SMOKE M2 129 4TH FL UNIT 499 MASTER SUITE x x x x x x x x ON _ __ N J M2-150 SPHOTO SMOKE M2-150 4TH FL UNIT 499 CORRIDOR EAST x x x x x x x X ON / -I r - 5 --- 2$� 0 2 cm M2-137 SPHOTO SMOKE M2-151 4TH FL UNIT 499 CORRIDOR WEST X X XXXXX X ON BEDROOM 2 CO LI o IDNET CHANNEL M2 SWITCH SETTINGS N M2 732 MCOPS FIRE M2-1.52 4TH FL UNIT 499 LIVING ROOM x x x x x x x X ON I 0 1 I Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 x x x ON 520HzS6\ y m M2-133 MCOPS SUPERV M2-133 6TH FL UNIT 677 ENTRY/MUD 100 x x x x x .2 _ MOKE M2 1 1ST FIR W RESIDENTIAL CORRIDOR x x x x x x x x ON / r -� M2-135 r PHOTO VSMOKE M2-2 1ST FIR MID W RESIDENTIAL CORRIDOR CZ x oN M2-134 MCOPS SUPERV M2-133 6TH FL UNIT 677 LIVING DINING 102 x x X x x x x x ON I0 x x x x x x x M2-135 MCOPS SUPERV M2-133 6TH FL UNIT 677 MSTR 103 x x x XXXX x ON s VT PHOTO VSMOKE M2-5 1ST FIR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON M2-136 MCOPS SUPERV M2-133 6TH FL UNIT 677 BEDROOM 2 x x x x x x x x ON ti foN v M2 PHOTO VSMOKE M2-4 15T FIR MID RESIDENTIAL CORRIDOR x ON [SCOPE OF WORK g a) x x x x x x x M2-137 MCOPS SUPERV M2-133 6TH FL UNIT 677 BEDROOM 3 x x x x x x x X ON W t o 492 PHOTO VSMOKE M2-5 IST FLR MID ELEVATOR LOBBY x x x x x x x x °N M2-1,58 SPARE X X X XX ON LL I CD X x x Lu M2 6 PHOTO VSMOKE M2 6 IST FIR MID RESIDENTIAL CORRIDOR x x x x x x x x °N M2-139 SPARE X x x x x x x X °" OO � � g v M2-7 PHOTO VSMOKE M2-7 75T FIR EAST RESIDENTIAL CORRIDOR x x x x x x x x ON J O M2-140 SPARE X X X X X x X X °N M2-8 PHOTO VSMOKE M2-8 IST FIR E ELEVATOR LOBBY xx x x x x x x ON Q LLI THROUGH ON TRUE Q U r C6492-9 ADRPUL PULL M2-9 1ST FIR WEST X x x X x x x x ON NORTH O > J .E M2-246 SPARE x x x x x x ON is M2-10 PHOTO VSMOKE M2-70 2ND FIR W RESIDENTIAL CORRIDLi X X ON X X X x X X X X ON O121 o M2 PHOTO VSMOKE M2-11 2ND FLR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON M2 247 ONETISO SO ONET+ ISOLATOR CIRCUIT Ax x x x XON DEVICE P LA C E V E\T PLA\ 6TH F L O O O O 3 X X ON M2-248 IDNETISO ISO IDNET+ ISOLATOR - CIRCUIT B x x x M2 PHOTO VSMOKE M2-12 2ND FLR MID W RESIDENTIAL CORRlDO z x x X X X X XON M2 249 ONETISO SO IDNET+ ISOLATOR CIRCUIT X x x x X X X X ON m b M2- PHOTO VSMOKE M2-13 2ND FIR MID RESIDENTIAL CORRIDOR x x x x xIf rif o 0 M2-250 ?NETISO ISO IDNET+ ISOLATOR - G x X x x X X X X ON SCALE: 1/8 = 1 -0 = M2-, PHOTO VSMOKE M2-14 2ND FIR MID ELEVATOR LOBBY x x X X x x x x ON o Q PHOTO X X X X ON NOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES. 0 4 8 16 8 M2 1_ VSMOKE M2 75 2ND FLR MID RESIDENTIAL CORRIDORx x x xTHE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS. (IN FEET) . o w M2-76 VSMOKE M2-76 2ND FIR EAST RESIDENTIAL CORRIDOR x x x x x x x x ON J ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING. .5 T 'T 192-77 PHOTO VSMOKE M2-77 2ND FIR E ELEVATOR LOBBY x x x x x x x x °N o $ 492-18 ADRPUL PULL M2-18 2ND FIR WESTx x x x x x x x " N N M2-19 SPARE x x x x x x x x ON o ai 112-20 ROTO VSMOKE M2-20 3RD FIR W RESIDENTIAL CORRIDO/ x x x x x x x x ON PHOTO VSMOKE M2-21 3RD FIR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON a M2-22 PHOTO VSMOKE M2-22 3RD FIR MID W RESIDENTIAL CORRIDOR x x x x X x x x ON M2-23 PHOTO I VSMOKE M2-23 3RD FIR MID RESIDENTIAL CORRIDOR X X X X X X X XON m 92 To M2-24 PHOTO VSMOKE M2-24 3RD FLR MID ELEVATOR LOBBY x x x x x x x x ON o M2-25 PHOTO VSMOKE M2-25 3RD FLR MID RESIDENTIAL CORRIDOR X x x x x x x x ON Z M2-26 PHOTO VSMOKE M2-26 3RD FIR EAST RESIDENTIAL CORK/DOR X x X x X X X X ON LODGE TOWER - NEW TRANSPONDER 4100es XPDR Speaker Db Loss Calculations o Q 192-27 PHOTO VSMOKE M2-27 3RD FIR E ELEVATOR LOBBY X XX X X x x x ON *Circuit Voltage = 7Ovrms [Et] MAXIMUM -3 dB DROP o M2 28 ADRPUL PULL M2-28 3RD FIR WEST x X x x x X X X ON WTotal Wire Est. Ckt. Wire Res. Circuit Speaker Speaker Voltage Watts Actual Max Allowable Q M2-29 SPARE XX x x x X X x °N Plan Speaker Speaker Speaker Speaker Watts Gauge Length Per Foot Resistance Current Resistance At End At End dB Loss Ckt. Length m M2-30 PHOTO VSMOKE M2-50 4TH FLR W RESIDENTIAL CORRIDOR x x X X X x x x ON SPEAKER CIRCUIT DESCRIPTION Circuit Tap Tap Tap Tap [P] [D] in [Rw] [RI=2D*Rw] [I=P/Et] [Rs=Et/I] [Es=(Et*Rs) [Pe=(Es) [dB=Log10 [ML=(0.414*Rs) o ';ROTO VSMOKE M2-51 4TH FLR MlD W RESIDENTIAL CORRIDOR x x x x x x x x °N Amo # Number .25 Watt .5 Watt 1. Watt 2. Watt Feet /(Rs+RI)] *2/Rs] (Pe/P)*10] /(2*Rw)] - Lu u12-32 PHOTO VSMOKE M2-52 4TH FLR MID W RESIDENTIAL CORRIDOR x x x x x x X XON 6TH FLR SPEAKERS (107 701) Amp-7 75 Wafts 89a 320 0.00/8 4.973 0.006 1051.579 19.064 4.705 -.04 db 27482 Ft E co 192 33 PHOTO VSMOKE M2 33 4TH FLR MID RESIDENTIAL CORRIDOR X x x x x X x x ON 5TH FIR SPEAKERS (107-102) Amp-1 37 - 5.75 Watts 189a 212 0.0078 4.848 0.082 852 774 69.604 5.685 -.05 db 22703 Ft. x X ON BSMT 1ST FLR SPEAKERS 101-103) Amp-1 S5 . Watts 189a 0.0078 0.000 0.000 0.000 0.000 0.000 . db 0 Ft. z m M2 34 PHOTO VSMOKE M2 34 4TH FLR MID ELEVATOR LOBBY X X X X X X / ( o Q x X X oN 2ND FIR SPEAKERS (102-101) Amp-1 S4 23 5.75 Watts 1890 280 0.0078 4.351 0.082 852.174 69.644 5.692 -.04 db 22703 Ft. F - J M2-55 PHOTO VSMOKE M2-55 4TH FLR MID RESIDENTIAL CORRIDOR a X X X X X 6TH/7TH FIR SPEAKERS (102-702) Amp-1 S5 . Watts 189a 0.0078 0000 0.000 0.000 0.000 0.000 . db 0 Ft. E M2-36 PHOTO VSMOKE M2-56 4TH FLR EAST RESIDENTIAL CORRIDORx x x x x x x x °N SRO FLR SPEAKERS (102-103) Amp-1 S6 23575 Watts 189a 288 0.0078 4.476 0.082 852174 69.654 5690 -.05 db 22705 Ft co g _ PHOTO VSMOKE M2 37 4TH FLR E ELEVATOR LOBBY x x X x x X x x ON 4TH FLR SPEAKERS (102-104) Amp-1 S7 23 5.75 Watts 7890 296 0.0078 4.600 0.082 852.174 69.624 5.688 -.05 db 22703 Ft. p o ADRPUL PULL M2-58 4TH FLR WEST x x X x x X x x ON 99 SERIES SPEAKERS (103-101) Amp-1 S8 . Watts 189a 0.0078 0000 0.000 0.000 0000 0000 . db 0 Ft. SPARE X X X x x X x XON 797,793 697,693 SPEAKERS (105-102) Amp-1 S9 8 2 Watts 189a 520 0.0078 4.973 0.029 2450.000 69.858 7.992 -.02 db 65270 Ft j/ = o PHOTO VSMOKE M2-40 5TH FLR W RESIDENTIAL CORRIDOR x X x x x x x x ON ELEVATOR 3 LOBBY SPEAKERS (103 703) Amp-1 S/0 Watts 189a 0.0078 0000 0000 0000 0000 0000 db 0 Ft. v 6TH/7TH FIR SPEAKERS (104-107) Amp-1 S11 . Watts 1890 0.0078 0000 0.000 0.000 0.000 0000 . db 0 Ft. o F 6TH/7TH FIR SPEAKERS (704-102) Amp-1 S/2 19 4.75 Watts 189a 520 0.0078 4.973 0.068 7037.579 69.664 4.705 -.04 db 27482 Ft. Q U zo c BSMT FIR SPEAKERS Amp-2 575 2 2 6. Watts 189a 272 0.0078 4.227 0.086 876.667 69.640 5.958 -.04 db 27757 Ft. o CO GRND FLR SPEAKERS Amp-2 S14 2 2 5 6.5 Watts 189a 244 0.0078 3792 0.093 753846 69.650 6.455 -.04 db 20083 Ft. w 1ST FIR SPEAKERS Amp-2 515 5 25 Watts 789a 272 0.0078 4.227 0.056 1960.000 69.849 2489 -.02 db 52216 Ft. Q m co 2ND FIR SPEAKERS Amp-2 S/6 5 2.5 Watts 189a 280 0.0078 4.351 0.056 7960.000 69.845 2.489 -.02 db 52216 Ft. C� g E Cri 3RD FIR SPEAKERS Amp-2 S17 5 2.5 Watts 189a 288 0.0078 4.476 0.036 1960.000 69.841 2489 -.02 db 52216 Ft. of • °' co 4TH FIR SPEAKERS Amp-2 S18 10 5. Watts 789a 425 0.0078 6.605 0.071 980.000 69.551 4.935 -.06 db 26108 Ft. w 3 o 5TH FIR SPEAKERS Amp-2 S/9 5 2.5 Watts 189a 504 0.0078 4.724 0.036 7960.000 69.832 2.488 02 db 52216 Ft. Cr)- o 0 6TH FLR SPEAKERS Amp-2 S20 5 5 3.75 Watts 18ga 450 0.0078 6.993 0.054 1306.667 69.627 3.710 -.05 db 34811 Ft. 7TH FLR SPEAKERS Amp-2 S21 _ 5 2.5 Watts 189a 520 0.0078 4.975 0.036 1960.000 69.823 2487 -.02 db 52216 Ft. GARAGE SPEAKERS Amp-2 522 6 15 16 Watts 789a 659 0.0078 10.241 0229 306.250 67755 14.981 -.29 db 8159Ft. SPARE Amp-2 S25 Watts 189a 0.0078 0000 0000 0000 0000 0000 db 0 Ft S C 0 P co 0 V'V' 0 R _z SPARAmp-2 S24 . Watts 0.0078 0^00 0.000 0.000 0.000 0.000 . db 0 Ft. TRUEDRAWN BY: VUK t E NORTH CHECKED BY: SKS Q EYP LA\ 6TH FL00 o OB DATE: 5/23/16 NOTE. INFORMATION IN BOLD TEXT REPRESENT NEW ITEMS BEING ADDED TO &Ai& SCALE: NTS PROJECT#: 419:992671801 _ o CURRENT INFORMATION. INFORMATION IN LIGHT TEXT REPRESENTS EXISTING It � SIMPLEXGRINNELL© 2016 • .o 173 INFORMATION. SYSTEM: 42L FIRE ALARM SYSTEM NICET CERTIFICATION03 SHEET: .m DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICE CHANGES TECHNICAL AREA 00303: LEVEL 3 g MADE IN THE FIELD WILL NOT BE REFLECTED IN THESE DRAWINGS. CERTIFICATE #: 83242 DEVICE PLACEMENT PLAN Q VALID THROUGH: 83242 14 y CO DEVICES IN THE INDIVIDUAL UNITS ARE BASED UPON CURRENT PROGRAM (n w E INFORMATION AND ASSUMPTIONS OF SPEAKERS IN UNITS. PLEASE VERIFY 5/27/2016 ALL DEVICE LOCATIONS. STEVE SHARP DATE FA-101 X a `m � � 0 0E co M L