HomeMy WebLinkAboutA16-0044_FA000_1478896246.pdf 4061 OF gr, z et FRY ■/i 4.6 -). tk V lig0.145-)L ■ LEGE\ ID . +��lG , • Vail Fire&Emergency lervicese rr' p• 07/13/16 SYMBOL DEVICE MANUFACTURER/PART# MOUNTING 113523 a' v 103 ROCKLEDGE RD ,. 0 i. ;' • FACP Honeywell Vista-128BPT ; Ademmo Vista 128 FACP Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox " * "•. ;:'�t"�; Standby ''AS/ONAL°, - Number of Current Total Current KP ••''•...."•"' Device Type Devices (Amps) _ (Amps) LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox Main FACP CPU 1 _3C 0.032 = 0.032 - 4193SN Serial Interface 3 _X- 0.00015 = 0.00045 Combination Smoke & COSMOD4W Module 3 X' 0.052 = 0.156 0 Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box i3 Smoke Detector 4 X' 0.0005 - 0.002 i4 Smoke/CO Detector 13 X 0.0005 = 0.0065 Combination Smoke and 6160 Keypad 2 X 0.04 = 0.08 Oco CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box SUM COLUMN FOR STANDBY LOAD 0.27695 = AMPS ® System Sensor 5601 P Alarm Load Heat Detector w/4193SN Addressable module 4" square box Number of Current Total Current Device Type Devices (Amps) (Amps) Main FACP CPU 1 X 0.032 = 0.032 E Cosmo Interface Module COSMOD4W 41935N Serial Interface 3 X 0.00015 = 0.00045 COSMOD4W Module 3 . X' 0.075 = 0.225 KB Knox Box i3 Smoke Detector 4 X 0.035 = 0.14 i4 Smoke/CO Detector 13 r X 0.04 = 0.52 6160 Keypad 2 X 0.1 = 0.2 ,0, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox Outside Horn/Strobe 1 X 0.195 = 0.195 z SUM COLUMN FOR ALARM LOAD 1.31245 = AMPS o Standby Load Required Standby Tme in Hours o_ Fc Current (Amps) o 0.27695 X 24 = 6.65 GENERAL NOTES: o Alarm Load Required Alarm Time in Hours z Current (Amps) (15 MINUTES) 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN o 1.31245 X 0.25 = 0.33 ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE w Add Standby and Alarm Load for Required DEPARTMENT REQUIREMENTS AND NFPA 72. Ampere Hour Battery 6.97 2. REFER TO MANUFACTURERS DATA SHEETS AND Multiply by the Derating Factor of 1.2 INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION Total Ampere Hours Required = 8.37 REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Batteries Provided: 12AH Minimumm w PROGRAMMING AND DEVICE OPERATION. Q 0 ZONE LIST 0 z ZONE # DESCRIPTION 1 SPRINKLER WATERFLOW oN 2 SPRINKLER TAMPER Co 3 LOWER LEVEL CO DETECTION O 4 LOWER LEVEL SMOKE DETECTION - Q 5 MAIN LEVEL CO DETECTION cc 6 MAIN LEVEL SMOKE DETECTION 0cz 7 UPPER LEVEL CO DETECTION approved as noted . Keep Q _ 5 ° o 8 UPPER LEVEL SMOKE DETECTION SEQUENCE OF z J 9 GARAGE HEAT DETECTOR stamped plans andpermit on N J < - • o o -r E 10 SYSTEM TROUBLE O P E SAT I O N S: w z z z o z o < ^ o jobsite available at inspection . m w Q Q w Q ° co o vi � C o � . Q w mc~ z w COaocn mlv co M cn x O_ _ � 2 S- Z 2 Z m ( ) , rr^^ d cn v Z QE NE ~ E � m vJ }° - c, mo cno cno cno (3 0ct a g DEVICE Q Q D V) N o N o Q 0 a� CC DESCRIPTION Q Q Q �• Q Q a ,ct , o 1_ o , o Q2 Q240 ��lur�� _ z SMOKE DETECTOR X X X F- O z - - - 0 HEAT DETECTOR X X X ti CARBON MONOXIDE DETECTOR X X X SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X OO CO POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X 1- 0, 0, PROJECT I \ EOIVAT O \ : o w .....--- 103 OCKLEIDGE VAIL COLORADO v C E RE ALAV SYSTEV z z D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) 0 < X = 2-WIRE DATA, 2-#16AWG EOL EOL AHJ: VAIL FIRE & EMERGENCY SERVICES Ct = O O APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 U N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG Z = 2-WIRE DATA CIRCUIT, 2-#16AWG D D FULLY SPRINKLERED J Q Ct KP = KEYPAD CIRCUITING, 4-#18AWG LUFIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM INCLUDES NEW J 0 RISER NOTES: �co C?) _I ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE D D CO DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE Ct = UJ 1 . REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE LJJ 0 H D MORE INFORMATION. 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS L,N El L,N PROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. HEAT DETECTORS (9 Q MANUFACTURERS SPECIFICATIONS. Lc [c WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO D 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (rIP) (TYP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE W 0 CO PRIOR TO INSTALLATION. WIRING DIAGRAM IS O HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM U D INCLUDED SUBMITTAL BOOKS. SYSTEM. U 0 < LU 120VAC DEDICATED POWER VISTA 128FPB Z O U �/ z CONTROL PANEL Z FLOW SWITCH J I-Z CD TELEPHONE LINE - FIRE TAMPER SWITCH CO „,..._ 0 UJ TELEPHONE LINE - SECURITY BELL N nWP FIRE PROTECTION ENGINEER: o U D OUTPUT - ,O, EOLR DEBORAH SHANER, P.E., SHANER LIFE SAFETY SHEET DESCRIPTION: DATA/COM KP I I I PO BOX 1073, FRISCO, CO 80443 S E� AG SAV OUTPUT KEYPAD KEYPAD PHONE: 970-409-9082 FIRE ALARM PLAN FAX: 970-797- 1898 DRAWN BY: DATE: DLS 6/22/16 SHEET#: FA-0.00