Loading...
HomeMy WebLinkAboutA16-0045_TOV FA0.01_1478896275.pdf olti OF go ..„......,,,,.. ze it, X Cia 055 AQlin% FIRE ALARM SYSTEM SEQUENCE OF OPERATIONS 08i1Fire&EmercncyServices 08/12/16 1 2 3 4 5 SYSTEM OUTPUT 5� '',6 S) N3 EOL ,x. © 15K0 Q OJ 15 RESISTOR SPG �5 N3-1 0 1HCO 5TH FLR. HALLWAY GQ ,' D ,P O% P �, P ©P PS DP OPCOSB RM �P� <Z- JC;i' �SJP 4/ D1-33 M1-13 D1-34 D1-35 M1-14 P.Q��JQ�',`Q-O `OJ OG\P 5TH FLR. Q 5 HALLWAY 5TH FLR. OFFICE 5TH FLR. BED �� �� �4 PJ P5 JAG`JAG`J�G`e' �� �� FIFTH FLOOR SYSTEM INPUT �4 �� �� GA \ G.4 P P P P A SMOKE DETECTOR (COMMON AREA) X X A SMOKE DETECTOR WITH LOW FREQUENCY B SOUNDER BASE AT BEDROOM X X B SMOKE DETECTOR & CARBON MONOXIDE C SENSOR WITH SOUNDER BASE X X C D MANUAL PULL STATION X X D E WATERFLOW SWITCH X X E 0 1P F TAMPER SWITCH X F ©P,COSB OP,s6 RM G SYSTEM TROUBLE X G D1-31 D1-32 M1-12 H SYSTEM SUPERVISORY X H 4TH FLR. BED 1 2 3 4 5 FOURTH FLOOR PANEL CIRCUIT DISTRIBUTION SCHEDULE PANEL NAME CARD LABEL AUX OR NAC CIRCUIT NUMBER DEVICE USED AREA COVERED ALARM ACTIVATION BATTERY CAPACITY NUMBER (MODULE ADDRESS) USED SLC #1 D1 DETECTORS LEVEL 1 TO LEVEL 5 M1 MODULES © © © © © © © © © © O 24 VDC AUX #1 24 VDC SOUNDER BASE SMOKE DETECTOR SOUNDER BASE AT LEVEL 2 TO LEVEL 4 P S 24 VDC AUX #2 24 VDC SOUNDER BASE SMOKE & CO DETECTOR SOUNDER BASE AT LEVEL 2 TO LEVEL 5 P P,CO,SB P,CO,SB P,SB P P,CO,SB P,SB P,SB P,SB P,CO,SB P FACP 2 ea. 11 AH D1-20 D1-21 D1-22 D1-23 M1-11 D1-24 D1-25 D1-26 D1-27 D1-28 D1-29 D1-30 NAC #1 N1 SUPPLY HORN/STROBE LEVEL 1 3RD FLR. DEPUTY 3RD FLR. 3RD FLR. 3RD FLR. 3RD FLR. 3RD FLR. NAC #2 N2 SUPPLY HORN/STROBE LEVEL 2 NAC #3 N3 SUPPLY HORN/STROBE LEVEL 5 STORAGE OFFICE LIVING BED #3 BED #2 BED #1 HALLWAY/STAIRS - NAC #4 SPARE THIRD FLOOR FACP NAC Voltage Drop Calculations FACP NAC Voltage Drop Calculations FACP NAC Voltage Drop Calculations Serving Level 1 Serving Level 2 Serving Level 5 / N2 EOL Project Name: TOV Fire Station#,Renovation,Vail,Colorado Project Name: TOV Fire Station#1 Renovation,Vail,Colorado Project Name: TOV Fire Station#1 Renovation,Vail,Colorado H O -"Oh-15Kf1 Date: 7/12/16 Date: 7/12/16 Date: 7/12/16 15 \75 RESISTOR Circuit Number: Notification Circuit 1,FACP,NAC#1 Circuit Number: Notification Circuit 2,FACP,NAC#2 Circuit Number: Notification Circuit 3,FACP,NAC#3 N2-1 N2-2 Prepared By: Prepared By: Prepared By: Nominal System Voltage 24 Wire Resistance Nominal System Voltage 24 Wire Resistance Nominal System Voltage 24 Wire Resistance 1 H EHU 2ND FLR. Minimum Device Voltage 21.6 Gauge Per 1000 Minimum Deuce Voltage 21.6 Gauge Per 1000 Minimum Device Voltage 21.6 Gauge Per 1000 Distance From Source to First Device(in ft.) 20 I 14 I 3.07 Distance From Source to First Device(in ft.) 65 I 14 I 3.07 Distance From Source to First Device(in ft.) 80 I 14 I 3.07 CORRIDOR HALLWAY/STAIRS Total Circuit Current(Amps) 1.36 Total Circuit Current(Amps, 0.24 Total Circuit Current(Amps) 0.05 Circuit Capacity(Amps) 2.5 Circuit Capacity(Amps) 1.75 Circuit Capacity(Amps) 1.75 ****Circuit is within limits**** ****Circuit is within limits*"** ****Circuit is within limits**** Spare%=I 45.6 I _ Spare%=I 86.2 I _- Spare%=I 95.4 I _ I - Location Device Device Distance(in ft.) Voltage at Drop from Percent Location Device Device Distance(in ft.) Voltage at Drop from Percent Location Device Device Distance(in ft.) Voltage at Drop from Percent Address Current(A) om Previous Devic Device Source Drop Address Current(A) om Previous Devic Device Source Drop Address Current(A) om Previous Devic Device Source Drop �1 P �1 P 2 © © © © © P S © Entry Ni-1 0.080 23.83 0.17 1% EHU Corridor N2-1 0.080 23.90 0.10 0% N3-, 0.080 23.96 0.04 0% P,Co,S6 P,SB P P,SB P,CO,SB P P Outdoor N1-2 0.365 35 23.56 0.44 2% 2nd Floor Hallway/Stairs N2-2 0.161 75 23.83 0.17 1% D1-13 D1-14 D1-15 D1-16 D1-17 D1-18 M1-10 D1-19 Gym N1-3 0.185 30 23.39 0.61 3% Conference Room N1-4 0.080 45 ' 23.19 0.81 3% EHU#2 EHU#2 EHU EHU#1 EHU#1 2ND FLR. HALLWAY/STAIRS Office Hallway N;-6 0.080 15 ' 23.13 0.87 4% LIVING BED CORRIDOR BED LIVING Bunker Gear N1-7 0.185 6300 22.95 ,. 4% Ni-8 0.080 60 ' 22.84 1.1618 5% Apparatus Bay N1-9 0.161 95 ' 22.71 1.29 5% Public Restroom N1-10 0.063 10 ' 22.70 1.30 5% SECOND FLOOR Total 1.36 365 Total 0.24 140 Total 0.08 80 N1 EOL © \O/ © © © © © © \O/ @ Nh 15K0 15 WP 75 15 15 15 75 15 75 15 RESISTOR N1-1 N1-2 N1-3 N1-4 N1-5 N1-6 N1-7 N1-8 N1-9 N1-10 0 1H FACP(VS2-G)Battery Calculation I ENTRY OUTDOOR GYM CONFERENCE OFFICE BUNKER APPARATUS PUBLIC Model/Description Qty. Standby Total(Standby Alarm Total A) larm ROOM HALLWAY GEAR BAY RESTROOM VS2-G,Base Panel 1 172 172 267 267 WIRING LEGEND VS2-G,Primary Loop Circuit 1 55 55 125 125 1P M1-7 M1-8 M1-9 V-PS,Smoke Detector 27 0.045 1.215 0.045 1.215 ©P PS ©P ©P PS ©P ©P ©P M MM M ©P OP SYMBOL WIRE TYPE USED ON STRAND COLORS O SB4U-LF,Audible Base(Supervisory) 7 6 42 0 0 REV DESCRIPTION DATE APPROVED D1-1 M1-5 D1-2 D1-3 M1-6 D1-4 D1-5 D1-6 ® i ® D1-7 D1-8 SB4U-LF,Audible Base(Alarn) 1 0 0 76 76 REVISIONS GSA-SBT,Audible Base(Supervisory) 8 1.46 11.68 0 0 1D 2-CONDUCTOR, #16 AWG, FIRE ALARM RED (+) FLOOR PLANS PROVIDED BY: PHONE ENTRY OFFICE B GYM CONFERENCE OFFICE OFFICE A MECHANICAL ROOM BUNKER GSA-SBT,Audible Base(Alarm) 0 0 52 52 b SOLID TWISTED CABLE, FPL OR NPLF ADDRESSABLE CIRCUIT BLACK (-) FOR: PHONE CV ROOM HALLWAY GEAR - �k GSA-T3T4,Temporal Pattern Generator 2 0.053 0.106 0.53 1.o6 N 1H 2-CONDUCTOR, #14 AWG, HORN/STROBE OR RED (+) 0 GSA-M278,Fire Alarm Station(Double Action) 5 0.25 1.25 0.4 2 I DRAWN BY: DATE 6 SOLID, FPL OR NPLF STROBE CIRCUIT BLACK (-) ot Q a GSA-CT1,Single Input Module 3 0.25 0.75 0.4 1.2 ANO 7/16/2016 z z z N 1 PCHECKED BY: DATE GSA-RM1,Riser Monitor Module 2 0.2 0.4 0.2 0.4 1P 2-CONDUCTOR, #14 AWG, 24 VDC RED (+) erl ion 24 VDC #1 MG1RF-HDVM,Wall Hom/Strobe(75 cd) 2 0 0 161 322 SOLID, FPL OR NPLF CIRCUIT BLACK APPROVED BY: ACP __SLC #14 TP TP �P QP QP QP b (-) InterMoun�an ilikilli M1-1 M1-3 WG4RF-HVMHC,Outdoor Hom/Strobe(65 cd) 1 0 0 365 365 M1-2 M1 4 D1 9 D1-10 D1-11 D1 12 Fire at Security 1D 3-CONDUCTOR, #12 AWG BLACK - HOT MGCFR-HDVM,Ceiling Hom/Strobe(15cd) 7 0 0 80 560 � 120 VAC WHITE - NEUTRAL l' OFFICE HALLWAY MECHANICAL STORAGE STORAGE STORAGE MGCFR-HDVM,Ceiling Hom/Strobe(75 cd) 2 0 0 185 370 SOLID,THHN GREEN - GROUND ROOM ROOM 1 ROOM 2 ROOM 2 MGCFR-VM,Ceiling Strobe(15 cd) 1 0 0 63 63 ALB E'T 1.'777-MANN EXAMPLE: I QUANTITY OF PAIRS NICET LEVEL IV 98794 TO DEDICATED 2 D AWG #16, SOLID TWISTED CABLE 0 C1-1111m---120V AC I MERIDIAN INTERMOUNTAIN FIRE & SECURITY BRANCH CIRCUIT 0 OFFICE HALLWAY P.O. BOX 3940 AVON CO, 81620 FIRST FLOOR TOTAL: 284.40 TOTAL: 2205.88 TEL. NO. (970) 748-8888 (mA) (mA) NOTE: SUPERVISORY HOURS: 24 _ - TOV FIRE STATION #1 RENOVATION ALARM MINUTES: 5 - 1. USE TYPE FPLR OR NPLFR FOR CABLES INSTALLED IN VERTICAL RUNS AND PENETRATING VAIL, COLORADO 81657 MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN A SHAFT. Minimum Battery Size(Ah) 7.01 FAS RISER DIAGRAM, SEQUENCE MATRIX, Total Alarm&Supervisory Current Required(in amp-hr)plus 20%spare: 8.4113363 2. USE TYPE FPLP OR NPLFP FOR CABLES INSTALLED IN DUCTS, PLENUMS AND OTHER CIRCUIT SCHEDULE 8c WIRING LEGEND FIRE ALARM SYSTEM RISER DIAGRAM Battery size to be supplied: 2 ea.12 Volts-11 Ah SPACES USED FOR ENVIRONMENTAL AIR. r APPROX. SCALE DWG N0. REV Project Name: TOV Fire Station#1 Renovation,Vail,Colorado NOT TO SCALE FAO. 01 SCALE: NONE Date:7/12/16 SHEET NO. 2 OF 7