Loading...
HomeMy WebLinkAboutData Submittal.pdf ti1,co SIMPLEXGRINNELL 14200 E. Exposition Avenue SimplexGrinnell Aurora, Colorado 80012 www.simplexgrinnell.corn Tele: (303) 355-0500 Fax: (303) 355-0615 7Fire Alarm Product Data Submittal for: Chalets at Vail Unit 1A Remodel 151 Vail Lane Vail, CO 81657-4511 tqco SimplexGrinnell 14200 E. Exposition Avenue Aurora, Colorado 80012 Sales: (303) 355-0500 Service: (303) 355-0500 Fax: (303) 355-0615 PROJECT: Chalets at Vail 7 Unit 1A Remodel TYPE: DESCRIPTION: Scope of Work Letter Unit 1A Floor Plan Revised Speaker Calculations Revised FACP Battery Calculations Revised NAC Panel#1 Voltage Drop Calculations Revised NAC Panel#1 Battery Calculations 4906-9153 SN M-C NON-ADDRESS, WHT, WALL VAIL CHALETS BLDG E-FACP 4100u FACP Speaker Db Loss Calculations *Circuit Voltage=70vrms[Et] MAXIMUM-3 dB DROP Total Total Wire Est.Ckt Wire Res.Circuit Speaker Speaker Voltage Watts Actual Max Allowable Plan Speaker Speaker Speaker Spkrs Watts Gauge Length Per Foot Resistance Current Resistance At End At End dB Loss Ckt.Length SPEAKER CIRCUIT DESCRIPTION Circuit Tap Tap Tap per IPI [D]in IRwi [R1=2D*Rwl II=P/Et] [Rs=Et/Il [Es=(Et*Rs)[Pe=(Es)[dB=Log10 [ML=(0.414*Rs) Amp# Number .25 Watt .5 Watt 1.Watt Circuit Feet SRs+R1)) *2/Rsl fPe/P)*10l /(2*Rw)I UNIT 1A SPEAKERS Amp-1 7:S3 1 7 2.Watts 18ga 514 0.0078 7.988 0.029 2450.000 69.773 1.987 -.03 db 65270 Ft. UNIT 18 SPEAKERS Amp-1 7:S4 e 6 1.5 Watts 18ga 470 0.0078 7.304 0.021 3266.667 69.844 1.49. 02 db 87027 Ft. UNIT 2A SPEAKERS Amp-1 7:S5 E 6 1.5 Watts 18ga 480 0.0078 7.459 0.021 3266.667 69.841 1 " 02 db 87027 Ft. UNIT 28 SPEAKERS Amp-1 7:S6 F 6 1.5 Watts 18ga 450 0.0078 6.993 0.021 3266.667 69.850 .02 db 87027 Ft. UNIT 3A SPEAKERS Amp-1 7:S7 6 1.5 Watts 18ga 355 0.0078 5.517 0.021 3266.667 69.882 01 db 87027 Ft. UNIT 38 SPEAKERS Amp-1 7:S8 6 1.5 Watts 18ga 330 0.0078 5.128 0.021 3266.667 69.890 .01 db 87027 Ft. UNIT 4A SPEAKERS Amp-2 7:S9 ,) 6 1.5 Watts 18ga 380 0.0078 5.905 0.021 3266.667 69.874 .02 db 87027 Ft. UNIT 48 SPEAKERS Amp-2 7:S10 6 6 1.5 Watts 18ga 350 0.0078 5.439 0.021 3266.667 69.884 01 db 87027 Ft. UNIT 5A SPEAKERS Amp-2 7:S11 5 5 1.25 Watts 18ga 280 0.0078 4.351 0.018 3920.000 69.922 01 db 104432 Ft. UNIT 58 SPEAKER Amp-2 7:S12 5 _ 5 1.25 Watts 18ga 235 0.0078 3.652 0.018 3920.000 69.935 _ .01 db 104432 Ft. UNIT 5C SPEAKERS I Amp-2 7:S13 6 _ 6 1.5 Watts 18ga 330 0.0078 5.128 0.021 3266.667 69.890 1.45_ .01 db 87027 Ft. UNIT 6A SPEAKERS Amp-2 7:S14 6 6 1.5 Watts 18ga 500 0.0078 7.770 0.021 3266.667 69.834 1.4(:' 02 db 87027 Ft. UNIT 68 SPEAKER Amp-3 7:S15 6 6 1.5 Watts 18ga 430 0.0078 6.682 0.021 3266.667 69.857 - 02 db 87027 Ft. GARAGE MEZZANi, Amp-3 7:S16 2 _ i 8 6.5 Watts 18ga 300 0.0078 4.662 0.093 753.846 69.570 t -.05 db 20083 Ft. SPARE Amp-3 7:S17 .Watts 18ga 0.0078 0.000 0.000 0.000 0.000 0.000 .db 0 Ft. VAIL CHALETS BLDG E-FACP 4100u FACP Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 11 1 4100 CONFIG.DOMESTIC 120V - 0.3730 0.4700 0.4700 4100-0634 2 POWER DISTRIBUTION MODULE 120V 0.0000 0.0000 0.0000 0.0000 4100-0636 1 BOX TO BOX HARNESS KIT 0.0000 0.0000 0.0000 0.0000 4100-0637 1 AUDIO BOX TO BOX HARNESS KIT 0.0000 0.0000 0.0000 0.0000 4100-1279 13 2"BLANK DISPLAY MODULE 0.0000 0.0000 0.0000 0.0000 4100-1282 1 8 SW,16RED/YEL LED MODULE 0.0000 0.0000 0.0240 0.0240 4100-1288 1 64/64 LED/SWITCH CONTROLLER 0.0200 0.0200 0.0200 0.0200 4100-1294 1 LED/SWITCH SLIDE-IN LABEL KIT 0.0000 0.0000 0.0000 0.0000 4100-1313 3 ANALOG FLEX 50W AMP W/3 CLASS B NAGS 70V 0.0850 0.2550 2.2700 6.8100 4100-2300 4 EXPANSION BAY(PHASE 10 ONLY) 0.0000 0.0000 0.0000 0.0000 4100-2320 4 AUDIO EXPANSION BAY KIT 0.0000 0.0000 0.0000 0.0000 4100-1245 2 FLEX 50 EXPANSION NAC BOARD 0.0084 0.0168 0.0600 0.1200 4100-3101 1 IDNET MODULE,UP TO 250 POINTS 0.0750 0.0750 0.1150 0.1150 4100-5101 1 EXPANSION PWR SUPPLY(XPS)-120VAC 60HZ 0.0500 0.0500 0.0500 0.0500 4100-5128 2 EXTERNAL BATTERY POWER 0.0000 0.0000 0.0000 0.0000 4100-6052 1 EVENT REPORTING DACT 0.0300 0.0300 0.0400 0.0400 4100-9620 1 BASIC AUDIO WITH MICROPHONE-ANALOG 0.2250 0.2250 0.2250 0.2250 4100-5116 1 EXPANSION AUDIO SIGNAL CARD 0.0180 0.0180 0.0800 0.0800 4100-1241 1 MESSAGE EXPANSION BOARD-8 MINUTES 0.0020 0.0020 0.0170 0.0170 Panel Totals I 1.0648 I 7.9710 IDNet Addressable Devices(SLC) 4099-9003 7 ADDRESSABLE DOUBLE ACTION PULL STATION 4090-9001 31 IDNET SUPERVISED IAM 4090-9002 39 IDNET RELAY IAM 4090-9101 13 IDNET CLASS B MONITOR ZAM Constant current draw of.8mA standby and 1mA 4090-9118 13 RELAY IDNET 2 IAM W/T SENSE alarm per address used.Devices requiring additional 4098-9714 197 TRUEALARM PHOTO SMOKE SENSOR current are accounted for in the section labeled 4098-9733 79 TRUEALARM HEAT SENSOR "Miscellaneous Peripheral Devices Requiring 4098-9756 1 TRUEALARM DUCT SMOKE SENSOR W/RELAY OUTPUT Additional System Power". 4009-9201 6 4009 IDNET NAC EXTENDER,120 VAC 4098-9792 193 TRUEALARM SENSOR BASE 4098-9794 83 TRUEALARM SENSOR SOUNDER BASE Miscellaneous Peripheral Devices That Require(Additional)System Power 4098-9843 1 ENCAPSULATED RELAY PAM-SD 0.0000 0.0000 0.0150 0.0150 4098-9756 1 TRUEALARM DUCT SMOKE SENSOR W/RELAY OUTPUT 0.0030 0.0030 0.0150 0.0150 4098-9794 83 TRUEALARM SENSOR SOUNDER BASE 0.0000 0.0000 0.0200 1.6600 2088-9021 26 ENCAPSULATED RELAY PAM-1 0.0000 0.0000 0.0150 0.3900 2081-9028 12 TRANSIENT CUBE FOR MAPNET 1,11 0.0000 0.0000 0.0000 0.0000 2081-9044 8 OVERVOLTAGE SUPPRESSOR 0.0000 0.0000 0.0000 0.0000 Notification Appliances 4906-9153 1 SUM-C NON-ADDRESS,WHT,WALL 15 0.0000 0.0000 0.0600 0.0600 4906-9153 3 SUM-C NON-ADDRESS,WHT,WALL 30 0.0000 0.0000 0.0940 0.2820 4906-9153 4 SUM-C NON-ADDRESS,WHT,WALL 75 0.0000 0.0000 0.1860 0.7440 MTWP-2475W-FR 18 WEATHERPROOF MULTI-TONE HORN STROBE,RED 75 0.0000 0.0000 0.1380 2.4840 RSS-24MCW-FR 4 MULTI CD STROBE,WALL MNT,RED 15 0.0000 0.0000 0.0600 0.2400 RSS-24MCW-FR 1 MULTI CD STROBE.WALL MNT.RED 30 0.0000 0.0000 0.0920 0.0920 Peripheral Totals 0.0030 5.9820 Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices 0.0000 0.0000 RUI Totals 0 0.0000 0.0000 Address Totals 386 Addresses 0.3088 0.3860 1.3766 14.3390 Select ALL Power Supplies on this battery set: SPS-1 0.8310 7.5830 XPS-2 0.2368 6.3700 Sub Total 1.0678 13.9530 Additional Current Draws: MAPNET/ZDNet Device Address Communication Current 386 x 0.000800 =0.3088 x 0.001000 =0.3860 Sub Total 1.3766 14.3390 Spare addressable point capacity 20% 78 x 0.0008 =0.0624 x 0.001 =0.0780 Total 1.4390 14.4170 Standby Time= 24 Hrs x 1.4390 =34.5360 Standby Ah Alarm Time= 15 Min 0.25 x 14.417 =3.6043 Alarm Ah 38.1403 Additional Spare Battery Capacity= 20% + 7.6281 45.7683 Battery Discharge Factor= 20% + 9.1537 Minimum Battery Required PW-PS12550U 55AH(2x) 54.9220 Battery Supplied 2081-9279 110AH(2x) (EXISTING) VAIL CHALETS BLDG E-4009#1 4009 NAC VOLTAGE DROPS PID 4906-9153 v - _ 4906-9153 4u__- J4 Candela 15cd 75cd 110cd WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE(UNCOATED SOLID COPPER WIRE)@ 75 Celsius Device Type MC SN MC SN MC SN SOUNDER Minimum Device Supv.Current Voltage @ Spare Quantity Alarm Current 0.0600 n 0.2520 0.0200 Circuit NAC Circuit/ Per Alarm Current @ 23 Volts 0.0600 0.2520 0.0200 Power Panel Plan Dist.(D) Wire Wire Res. Total V.Drop Volt %Volt Min Device Max Capacity Output Branch Circuit/ NOTIFICATION CIRCUIT DESCRIPTION Supply Circuit Ckt. Feet Gauge /Ft.(R) Alarm(A) (A*2D*R) @ End Drop Voltage Distance (Amps) Terminals Capacity Branch UNIT 1A STROBES 4009 SIG1 7:N1-1 319 14ga 0.0031 0.864 1.692 17.808 8.68% 16vdc 660 Ft. 4 1 2.A 19.5 51.6% 7 4 NOTE: LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP.THIS METHOD ALLOWS FOR A SMALL MARGIN OF SAFETY,TAKING INTO CONSIDERATION THAT THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT LENGTH,CONTACT YOUR LOCAL SIMPLEXGRINNELL DISTRICT OFFICE. VAIL CHALETS BLDG E-4009#1 4009 NAC Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 4009-9201 1 4009 IDNET NAC EXTENDER, 120 VAC 0.0850 0.0850 0.1850 0.1850 Panel Totals 0.0850 0.1850 Notification Appliances 4098-9794 _ 11 TRUEALARM SENSOR SOUNDER BASE 0.0000 0.0000 0.0200 0.2200 4906-9153 _ 1 SN M-C NON-ADDRESS,WHT,WALL 110 0.0000 0.0000 0.2520 _ 0.2520 4906-9153 8 SN M-C NON-ADDRESS, WHT, WALL 15 0.0000 0.0000 0.0600 _ 0.4800 4906-9153 4 SN M-C NON-ADDRESS, WHT, WALL 75 0.0000 0.0000 0.1860 0.7440 Peripheral Totals 0.0000 1.6960 0.0850 1.8810 Select ALL Power Supplies on this battery set: 4009 0.0850 1.8810 Total 0.0850 1.8810 Standby Time= 24 Hrs x 0.0850 =2.0400 Standby Ah Alarm Time= 15 Min 0.25 x 1.881 =0.4703 Alarm Ah 2.5103 Additional Spare Battery Capacity= 20% + 0.5021 3.0123 Battery Discharge Factor= 20% + 0.6025 Minimum Battery Required 2081-9272 6.2AH(2x) 3.6148 Battery Supplied 2081-9272 6.2AH(2x) EXISTING