HomeMy WebLinkAboutTrue Alert Multi Candela.pdf ®SimplEx TrueA/ert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Speaker MEA (NYC) Acceptance* and Multi-Candela Strobe; Non-Addressable Features - ' --111:1 ,, - - , w-_ _ _-. Speaker/visible(SN) notification appliances with _ multi-tapped speaker and multi-tapped high intensity xenon strobe with synchronized flash: • Rugged,high impact,flame retardant thermoplastic - - housings are available for wall or ceiling mount • Operation is compatible with ADA requirements(refer to important wall mount installation information on page 4) , Wall mount SN features: "' —" _ maj • Housings are available in red or white with clear lens II 1� � ID 01IJIiiiI1t � with contrasting white or red"FIRE"lettering T • Covers are available separately to convert housing color FIRE FIRE Ceiling mount SN features: ,,, • Housing is white with clear lens • Red"FIRE"lettering is printed on two sides — Audible notification appliance (speaker): , zo- _________ N, • High quality voice and tone reproduction with taps for F v�� '/a,'/z, 1,or 2 W,at 25 or 70.7 VRMS t ; -�> • Capacitor input for connection to supervised notification \ .h /_. appliance circuits • Speakers are wired separately from strobe wiring • UL listed to Standard 1480 and ULC-S541 • Compliant with NFPA 72,520 Hz Low Frequency Signal Requirements for Sleeping Areas Wall and Ceiling Mount S/Vs Visible notification appliance (strobe): Descri•tion • 24 VDC xenon strobe;intensity is selectable as 15,30, 75,or 110 candela with visible selection jumper secured Multi-Candela TrueAlert SNs with speaker and behind strobe housing synchronized strobe provide convenient installation to standard electrical boxes with extensions.The • Strobes are activated from NACs selected to provide ® enclosure designs are both impact and vandal resistant Simplex®strobe synchronization signals or from and provide a convenient strobe intensity selection. Since separate strobe Synchronization Modules that are each model can be selected for strobe intensity output, available for Class B or Class A operation on-site model inventory is minimized and changes • Regulated circuit design ensures consistent flash output encountered during construction can be easily and provides controlled inrush current accommodated. • UL listed to Standard 1971 and ULC-S526* Wall mount SN housings are a one-piece assembly Options for wall mounted SNs: (including lens)that mounts to a 4"square electrical box • Red or white adapters to cover surface mounted with extension(see details on page 4).The cover can be electrical boxes quickly removed(a tool is required)and covers are • Red adapter for mounting to Simplex 2975-9145 boxes available separately for color conversion. • Red wire guard Ceiling mount SNs also install using 4"electrical boxes with an extension(see details on page 4). * See page 2for adcitionalllisting details and Aire guard listings.11s product has been Strobe Intensity Selection approved by the California State Fre Marshal(CSFM)pusuait to Section 13144.1 of the Duringinstallation,a selection plugat the back of the California health and Safety Code.See CSFM Listing 7320-0026:247 for etIo ble values and/cr condition ocnceming material presented in this document.Accepted for use—City housing determines the desired strobe intensity.An of New York Department of Buildings—MEA35-93E.Additional listings may be applicable; attached flag with black letters on a highly visible yellow contact your local Simplex product supplier for the latest status.Listings and approvals background allows the selected intensityto be seen at the under Sinplex Time Recorder Co.are the property of Tyco Fre Protection Prcduds. side of the strobe lens. S4906-0003-8 5/2014 Synchronized Strobes Strobe Application Selection Multiple Strobes.When multiple strobes and their Proper selection of visible notification is dependent on reflections can be seen from one location, synchronized occupancy, location,local codes,and proper applications flashes reduce the probability of photo-sensitive reactions of:the National Fire Alarm and Signaling Code as well as the annoyance and possible distraction of (NFPA 72),ANSI A117.1;the appropriate model random flashing.The multi-candela strobes of these S/Vs building code: BOCA,ICBO,or SBCCI;and the are activated by NACs that provide the Simplex application guidelines of the Americans with Disabilities synchronization format.For additional information,refer Act(ADA). to data sheet S4905-0003. Product Selection Wall Mount Multi-Candela S/Vs Model Housing "FIRE" Listings Description Housing Dimensions with Lens Color Lettering 4906-9151 Red White Multi-tapped Speaker with Multi-Candela5 „ UL&ULC Synchronized Strobe;strobe intensity 7 /^"H x 5"W x 2 /8 D 4906-9153 White Red selectable as: 15,30,75,or 110 candela (184 mm x 127 mm x 67 mm) Ceiling Mount Multi-Candela SN Model Housing "FIRE" Listings Description Dimensions Color Lettering 4906-9154 White Red UL Housing=7'/z"(191 mm) Multi-tapped Speaker with Multi-Candela diameter, /2'(13 mm)deep Synchronized Strobe;strobe intensity Strobe lens protrusion=2%" 4906-9157 White Red ULC selectable as: 15, 30,75,or 110 candela (67 mm)above speaker housing Depth into box=2 3/4'(70 mm) Wall Mount SN Adapters Model Description Dimensions 4905-9946 Surface mount red adapter skirt Required when mounting to surface 7 3/4"H x 5%"W x 3 3/6"D mounted electrical box,4"square, (197 mm x 137 mm x 81 mm) 4905-9947 Surface mount white adapter skirt 1 '/2"deep with 1 IA"deep extension depth with S/V=5'/8'(149 mm) 4905-9903 Adapter Plate, red, required to mount SN on 2975-9145 8 5/6"H x 5 3/4"W x 0.060"Thick (211 mm x 146 mm x 1.5 mm) 2975-9145 Mounting box, red,for surface or flush mount, requires adapter plate 7'A"H x 5'/8'W x 2 3A"D 4905-9903(this box may be available for retrofit applications) (200 mm x 130 mm x 70 mm) Wall Mount SN Replacement Covers Model Description Dimensions 4905-9996 Red S/V cover with white"FIRE"lettering 7 1/4"H x 5"W x 1 %"D 4905-9997 White SN cover with red"FIRE"lettering (184 mm x 127 mm x 35 mm) Synchronized Flash Control Modules Model Description Dimensions 4905-9914 Synchronized Flash Module,Class B Epoxy encapsulated with in/out operation 18 AWG(0.82 mm2)wire leads, 1 %"W x 2'/6"L x 13/16"H Synchronized Flash Module,Class A rated for 2 A NAC, requires 5 mA (35 mm x 62 mm x 20 mm) 4905-9922" operation for power Wall Mount SN Wire Guard Model Description Dimensions 4905-9998 Wire guard with mounting plate, red,compatible with surface and semi-flush 8 3/8"H x 6 5/6"W x 3'/4"D boxes(UL listed by Space Age Electronics Inc.) (213 mm x 154 mm x 79 mm) Ceiling Mount Tile Bridge Model Description Dimensions 2905-9946 Tile Bridge See diagram on page 4 Refer to data sheet S4905-0003 for additional flash control module information 2 S4906-0003-8 5/2014 S/V Specifications Common Environmental 32°to 122°F(0°to 50°C); 10%to 93%,non-condensing at 100°F(38°C) Specifications Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Speaker Specifications Input Voltage 25 or 70.7 VRMS,see Note 1 below Power Taps '/4,'/2, 1,and 2 W Fire Alarm 400 to 4000 Hz Frequency Response General Signaling 125 to 12 kHz Wattage Tap 1/4W 1/2W 1W 2W UL Listed Models,Reverberant Chamber Test,per UL 1480 76 dBA 79 dBA 82 dBA 85 dBA Speaker Output Wall Mount Models 4906-9151 and 4906-9153, Ratings @ 10 ft(3 m) Anechoic Chamber Test,per ULC S541 77 dBA 80 dBA 83 dBA 86 dBA* (see Note 1 below) Ceiling Mount Model 4906-9157, 25 VRMS Input 81.6 dBA 84.3 dBA 87.1 dBA* 89.7 dBA* per ULC-S541 70.7 VRMS Input 80.9 dBA 84.1 dBA 87.3 dBA* 90.2 dBA* *NOTE:Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference(per ULC-S541 Attenuation Angle Attenuation Angle Anechoic Chamber Testing) -3 dB +/-30°off-axis -6 dB +/-55°off-axis Strobe Specifications Rated Voltage Range Regulated 24 VDC; 16 VDC to 33 VDC,see Note 2 below Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Housing Dimensions(with lens) 7'/4'H x SW x 2%"13(184 mm x 127 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents at 18 VDC 53 mA 84 mA 165 mA 224 mA other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions Speaker housing=75/2°(191 mm)diameter,'/2"deep(13 mm);lens protrusion above speaker housing=2/e (67 mm);depth into box=2 /4 (70 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting 75 mA 125 mA 233 mA 316 mA Reference RMS Currents at 18 VDC 67 mA 111 mA 207 mA 281 mA other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. Speakers are for connection to conventional fire alarm audio circuits.Anechoic speaker output ratings are typically more representative of actual installed sound output. 2. The maximum RMS strobe current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Speaker Directional Characteristics Reference 85 84 0 83 m• 82 v 81 .' 80- af 79 78 a 77 v 2• 76 75 fp 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 Angular Displacement(Degrees)on Horizontal Axis -2kHz-4kHz 3 S4906-0003-8 5/2014 Ceiling Mount SN Installation Reference and Tile Bridge Dimensions O o 2905-9946 1/2"(13 mm) Tile Bridge 00 I' )� -4"(102 mm)square,1-1/2 0 (38 mm)deep box with 1-1/2" 0.024"thick sheet metal,folded with 0 extension(by others) 1/2" lip each side «0.6k1'.,41.1.1.14. i.�! �'I / 3-3/4"(95 mm)square I cut.ut,centered on plate (ii oll ,I Wiring input terminals and speaker tap selection are 23-11/16" � accessible from rear of (602 mm) i\ \ speaker housing 1 'f ,is 1/4"diameter(6 �1 mm)holes,4 places 111Air Strobe intensity (1411 � viewing slot Intensity selection plug, r accessible only from rear of lens (170 mm) housing;factory setting is 15 cd 13-3/8"(340 mm) Wall Mount Installation Reference IMPORTANT!INSTALLATION r Mounting to 2975-9145 Box s i Standard Electrical Box Mounting ` MOUNTING HEIGHT REFERENCE 4"(102 mm)square box,1-1/2" 2975-9145 2975-9145 Box (38 mm)deep,with a 4"square box box outline 4"square box outline extension,1-1/2"deep,by others A'I S ® 1. —4"(102 mm) �Th �Th -10 0 rj L__ A J 82"(2.1 m) 1-1/2"(38 mm) // /) r o f 1 o J r minimum 4905-9903�- J a- J 41‘ - o NFPA 72 requires that the Adapter Plate (- �J 78-1/2"(2 m) entire lens be not less than - J • 0 I minimum 80"and not greater than 96" rJ above the finished floor. C__• —)C.__Th ITh./ l 1 1 \„._ %i---------------= l4 Wiring input terminals and Surface Mounting Reference y°°°�°°Q"a OffeDielgaspeaker tap selection are Showing Optional Wire Guard in accessible from rear ---= — Surface mount conduit and o—- Speaker assembly box shown farrreference N .11- Strobe assembly 1St4"(102 mm)square box—.1111Er 4 r profile,1-1/2"(38 mm) jj / deep with 1-1/2"extension II J Intensity selection 75° Optional 4905-9998 Wire Guard tim i Transparent plug,accessible only VIII housin and from rear of housing; �® t♦�II' Removable cover 9 diM factory setting is 15 cd SW I= (tool required) lens assembly F E Strobe intensity IA viewing slot Surface mount adapter skirt,3-3/16"(81 mm) deep,required for this mounting method: 4905-9946,Red;4905-9947,White(conduit knockouts are provided on all four sides) TYCO,SIMPLEX and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NFPA). ®Sim pi EX Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4906-0003-8 5/2014 www.simplex-fire.com ©2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice.