HomeMy WebLinkAboutA16-0048 scope of work.pdf Ce-)1SWC NOT I FIEF "; Commercial Specialists of Z(iestern G'otoraoto, LLC Tuesday, August 16, 2016 Vail Fire 42 West Meadow Drive Vail, CO 81657 Attn: Mike Vaughan, Fire Marshal Pjct: Fleeger Residence Re : Scope of Work for Fire Alarm System Dear Mike, The following is a scope of work to be performed for the Fleeger Residence at 2950 Booth Creek Drive. The scope of work will be to bring the residence up to NFPA standards adopted by Vail Fire. I have included a mark-up set of drawings with this scope of work to better detail the scope. Work performed will be to low frequency notification devices to each level and each bedroom for general alarm notification. 120vac Combination Smoke/CO devices will be added as required throughout. An exterior horn for fire sprinkler activation will be installed by the garage along with a stand alone CO detector in the mud room at the garage entry to the home. Each detection device will have a dedicated 18/6 FPL from the fire control panel and each floor will be provided with a dedicated 14/4 NAC circuit from the power supply. Whatever fire sprinkler devices are installed will be independently monitored at the fire panel location. The fire/security panel that we are providing for this scope is the Bosch B5512. Data sheets for all device that we intend to install are included in submittal. Once work has been completed and tested, CSWC will contact Vail Fire Department and schedule a final fire alarm test of the new area. If there are any questions or concerns about the above information, please feel free to contact me at any time. Sincerely, Commercial Specialists of Western Colorado, LLC 210 Marmot Lane Unit 5B* PO Box 3913* Eagle, Colorado 81631 Voice(970)328.1951 Fax(970)328.1956 www.cswcfire.com C-111SWC NOTI FI E F "; Commercial Specialists of Western G'otoraoto, LLC YUcotog Tim Ward General Manager 210 Marmot Lane Unit 5B* PO Box 3913* Eagle, Colorado 81631 Voice(970)328.1951 Fax(970)328.1956 www.cswcfi re.com Intrusion Alarm Systems I B5512 Control Panels B5512 Control Panels www.boschsecurity.com �OD B os ci-u Invented for life 4111— 905CN -•''xa os®s ROSCH rU252 MODULE 1 ICY IF EA 1 U , COMMUNICATION MODULE 1 ETHERNET 'SE ° MAC ® BOSCH ooa,u,> ► Provides up to 48 points using a combination of o� ��. LINK hardwired or wireless points for installation OUTPUT A UMI i flexibility and up to 4 areas with perimeter and °JumorUnder Cow ooze DDM .;1¢ interior control Bffi3012 ONBOR8O POINTS 0010010 001018°1 y ByMy A Y 0 a O.R 3,.�0„� 4,, ► On-board Ethernet port for Conettix IP alarm NmDY 00-1.3VDC 8 �mo ShM OO.SJVOC 1 kT1 EndofUn°RaMron communication and remote programming, 38 VAC+ BRTIEFY OIIIPUTR 1PVr 1 COM 2 13 00M 415 COM 81 T COM 8 ® � oc� �� compatible with modern IP networks including IPv6/ IPv4, Auto-IP, and Universal Plug and Play ► Installer-friendly features including on-board USB for easy on-site RPS programming, plus support for Remote Connect Service and plug-in PSTN and cellular communication modules for simple installation and communications ► Remote Security Control (RSC) app which allows users to control their security systems - and view system cameras - remotely from mobile devices such as phones and tablets ► Programmable keypad shortcuts, situation sensitive on-screen help, and a bilingual user interface make system operation simple and easy The B5512 Control Panel integrates intrusion and Use programmable authority levels with restricted residential fire, providing one simple user interface for privileges to provide service, security, and cleaning both systems. The B5512 provides up to 48 personnel with full or limited access. Use the three individually identified points that can be split into 4 programmable outputs (expandable up to 43) to turn areas. on lights or lock and unlock doors. Users can: The control panel can communicate through it's built- • Turn on the system to secure the stockroom while in Ethernet port (not applicable to "E" control panels), you conduct daily business. or through compatible plug-in modules that can send • Perform tests to ensure your system is working events over the public switched telephone network properly. (PSTN) or over cellular network communications. • Set your system to alarm immediately if a door opens. With the B5512, you can monitor doors, windows, and Activate the Watch feature so a tone sounds motion within areas like showrooms or those that hold whenever a customer enters. inventory. Each user can have a personalized • Set a schedule for your system to automatically turn passcode, a wireless keyfob, and a credential to on at closing time. control the system. • Use wireless security options to customize your system. 2 I B5512 Control Panels Central monitoring stations provide 24-hour system Passcode security monitoring with access to vital services. Professional • Two-man rule. Requires two people with two unique security personnel can test the system, monitor passcodes to be present at the time of opening. system activity, and alert the police, fire department, • Early ambush.Allows users to verify that the facility is or other emergency response teams if necessary. safe by requiring two passcodes. The control panel sends a duress event if the user does not enter the Functions passcode a second time after inspecting the premises. Programmable outputs • Dual authentication. Requires two forms of • Three programmable on-board outputs; one high identification before processing certain system current using a relay, and two trigger outputs commands, including turning off the system and • Output A, with a contact rating of 3 Amps, can supply opening doors.A standard system user must have a up to 1.0 A total current from AUX PWR passcode, a credential (token or card), and • Outputs B and C sink up to 50 mA at 12 VDC appropriate command authority permissions. • Four alarm-output patterns • Programmable bell test Easy exit control The control panel changes from one On (armed) state Point response to another without turning off (disarming) the system. • 20 custom point indexes For example, if you change the state from Part On • Selectable point response time (Perimeter Arm) to All On (Master Arm), the control • Cross point capability panel complies and reports the change. Easy Exit • Fire alarm verification Control reduces the number of keystrokes, simplifying • Dangerous gas indicator includes carbon monoxide (NEPA 720) system operation. • Watch mode Programmable passcode-controlled menu list User interface Passcode-controlled shortcuts provide users only with • Supervision of up to 8 keypads the options and information pertinent to them, • Custom keypad text is fully programmable through simplifying system operation. RPS Flexible control • Full function menu including custom functions The system provides the flexibility to choose added • Authority by area and 32 character name for each convenience or high security. For example, you can user restrict to a keypad's immediate local area turning on • 14 custom authority levels to restrict system features that each user can access (arming) and turning off (disarming) the system with a • Programmable primary and secondary language by passcode, even if the user has access to other areas. user and keypad; select from English, Spanish, This is particularly useful for high security areas, French, and Portuguese where a user may have access to the area, but would prefer to only turn off (disarm) the area individually Area configurations rather than with the rest of the system. Link multiple areas to a shared area such as a lobby or common entryway. The shared area then automatically Monitor Delay/Delayed Response turns On (arms) when all associate areas are armed Create a special point index that delays the reaction of and turns Off (disarms) when any one associate area a point for a specified time (up to 1 hour in minutes is disarmed. For higher security applications, the Area and seconds). This delay provides time for the Re-Arm feature guarantees that areas are always specified condition to reset before activating any rearmed, and are disarmed for no longer than a annunciation. The system can annunciate locally and specific, configurable, amount of time (for example, send a report, if desired. When the system is armed, service time). the point can respond like a normal point — providing dual functionality. Use this feature to ensure that Custom functions perimeter doors have not been propped open, or to For added convenience, the installer can program monitor critical areas such as computer rooms and custom functions that allow customers to complete safes, for example. complex tasks with one simple action. For example, a custom function can bypass a group of points and arm System users the system, allowing the user to perform these The system supports up to 50 users. Each user can functions with one easy command. Users can activate have a personalized passcode, a wireless keyfob, and a custom functions with a keypad, keyfob, token, or credential to control the system.You can assign card, or the control panel can activate a function in passcodes to one of 14 customized authority levels in reaction to a faulted point, or automatically through a each area that can be restricted to operate only during scheduled event (SKED). certain times. Programmable primary and secondary language by user and keypad; select from English, Spanish, French, and Portuguese. 3 I B5512 Control Panels Communication formats Ethernet (IP) connection (the on-board Ethernet port The control panel prioritizes and sends reports to four is excluded on "E" versions) to transfer firmware route groups. Network and phone communications can updates. use either the Modem4 or the Contact ID The control panel can optionally receive firmware communications formats. Each group has a updates from RPS using a B426 Conettix Ethernet programmable primary and backup destination. Communication Module or a Conettix Plug-in Cellular The control panel provides flexible communications for Communicator (B440/B441/B442/B443). Notice! most central stations with reporting capabilities such Cellular firmware updates require more time than as: Ethernet updates and carrier data rates apply. • Individual point numbers • Control panel updates. Remotely update the control • Opening or closing reports by user and area number panel firmware for easy feature enhancements • Remote programming attempts without replacing ROM chips. • Diagnostic reports • Module update support. Remotely update the IP communication firmware on connected SDI2 modules for easy feature The control panel can use on-board Ethernet (IP) enhancements without visiting each individual connection (the on-board Ethernet port is excluded on module. "E" versions) to communicate with a Conettix D6600 A wide variety of input options or a Conettix D6100IPv6 Communications Receiver/ Each point: Gateway. • Single 1 kO, single 2 kO, dual 1 kO (1 kO+ 1 kO), and The control panel can optionally use a Conettix Plug-in No EOL (end-of-line) (EOL) resistor options (for on- Cellular Communicator (B440/B441/B442/B443). board and B208 inputs) Using Conettix IP communication offers a secure path • Programmable for Fire, Intrusion, Gas, and that includes anti-replay/anti-substitution features and Supervisory devices provides enhanced security with up to AES 256-bit • Supports hardwired and wireless devices encryption (using Cipher Block Chaining (CBC)). • Supports IP cameras by Bosch as point and output The control panel supports Domain Name System devices (DNS) for both remote programming and central IP camera support station communication. DNS provides ease of use, The control panel can integrate directly with Bosch IP eliminating the need to use static IP addresses as your cameras, using them as fully supervised points and reporting destination, and accommodates a simple outputs. solution for central station disaster recovery. The Integration of cameras allows the camera's video control panel supports both IPv6 and IPv4 networks. motion detection to activate points on the control Communication paths panel. The control panel's virtual outputs can be The control panel accommodates up to four separate configured to trigger camera actions, including phone and four separate network paths to the central sending video snapshots via email. station receiver. When resetting alarms or turning a Security and fire detection system on and off, the user is identified by name and The control panel provides eight on-board points, and number. up to 40 additional off-board points (depending on Personal notification model and expansion interfaces). You can program The control panel can send text messages and emails individual points to monitor some types of burglar for personal notification over Ethernet or using a alarms, fire alarms, and supervision devices. cellular communicator.You can configure up to 16 Event log destinations using a combination of cellular phone The event log stores local and reported events. The numbers and email addresses. The control panel sends event log includes information such as time, date, notifications in the user's programmed primary event, area, point, and user. View the event log from a language. keypad or use RPS to remotely retrieve event Bosch Remote Connect (Cloud) information. When the event log reaches a Remote Connect simplifies connections from RPS, and programmed threshold of stored events, it can send an the Remote Security Control app, using Bosch Cloud optional report to a receiver. services. This service creates a secure connection to The event log stores up to 255 local and reported the control panel without specific router settings or events. the need for a static IP address or DNS. Scheduled events (SKEDs) Firmware updates The internal clock and calendar start individually The system allows remote firmware updates through scheduled events (SKEDs). SKEDs perform several Remote Programming Software (RPS) using the RPS functions such as turn on or off, relay control, or point Firmware Update Wizard. The Firmware Update Wizard bypassing. The control panel offers: uses the on-board USB connection or the on-board 4 I B5512 Control Panels • Five scheduled events with up to 25 different to a Bosch VMS base license. Refer to the Bosch functions Video Management Software product page on the • Four opening windows and four closing windows Bosch website, www.boschsecurity.com. • Four user group windows • Access to Remote Programming Software (RPS). • Day-of-week, date-of-month, or holiday only schedules • One holiday schedule of 366 days (leap year) Certifications and approvals Programming Region Certification Installers can perform limited programming on-site - with a keypad (critical parameters; such as account USA ANSI- CP-01-2010-Control Panel Standard- IDs, central station and RPS IP addresses and phone SIA Features for False Alarm Reduction numbers, reporting formats, and more). They can also Europe CE B6512,B5512,B5512E,B4512, do full programming on-site or remotely (attended or B4512E,B3512,B3512E unattended) with RPS. A programmable system USA UL passcode prevents unauthorized remote programming. UL UL 365-Police Station Connected Bur- Diagnostics glar Alarm Units Keypads and RPS offer diagnostic help for monitoring and troubleshooting. The diagnostics features allow NUL UL 609 Alarm Units and arSS sLocalBurglar ystteems you to view the status of the wired and wireless devices. The features provide the status of the control UL UL 636-Holdup Alarm Units and Sys- panel and its connected devices, such as firmware terns version, power, and missing conditions. View the UL UL 985-Household Fire Warning Sys- status of each area. tem Units Remote Security Control app UL UL 1023 Household Burglar Alarm Sys The Remote Security Control (RSC) app allows users tem Units to control their security systems remotely from their UL UL1076-ProprietaryBurglarAlarm devices. Users can: Units and Systems • Turn their security system On or Off UL UL 1610-Central Station Burglar Alarm • Turn specific areas On or Off Units • Control outputs for applications such as lighting control UL UL 1635-Standard for Digital Alarm • View live video from Bosch IP cameras Communicator System Units • Grant access remotely by unlocking and locking doors CSFM seeourwebsite The app requires the installing dealer to create a FCC Part 15 Class B Remote Access Profile for users, and to install the profile on their devices. Canada ULC Bosch Video Management System integration ULC CAN/ULC S303-Local Burglar Alarm With Bosch Video Management System (Bosch VMS) Units and Systems and an intrusion system, the VMS operator has a single ULC CAN/ULC S304-Standard for Signal Re- user interface to monitor and control the intrusion ceiving Center and Premise Burglar system combined with video surveillance. With Bosch Alarm VMS and a control panel, the operator can, for ULC CAN/ULC S545-Residential Fire Warn- example: ing System Control Units • View videos triggered by intrusion events, including ULC CAN/ULC S559-Fire Signal Receiving all relevant information such as areas, point, and user Centres and Systems show in the display with the event • View areas, points, outputs, and doors—with their ULC ULC-ORD C1023-Household Burglar Alarm System Units statuses—on the Bosch VMS map, providing the exact location in the system. ULC ULC-ORD C1076-Proprietary Burglar • Turn on (arm) and turn off(disarm) areas. Alarm Units and Systems • Bypass and unbypass points. IC ICES-003-Information Technology Requirements to integrate Bosch VMS with a control Equipment(ITE) panel: • A licensed Bosch VMS system using Professional Installation/configuration notes Editions v5.5 or higher or Bosch VMS Enterprise • Edition v5.5 or higher. Compatible products • Expansion license to integrate the intrusion control Keypads panel. One license needed per control panel. Order number MBX-XINT-xx for the expansion license added B942/B942W Touch Screen Keypad(SDI2) 5 I B5512 Control Panels B930 ATM Style Alphanumeric Keypad(SDI2) B810 wireless receiver(RADION) B921C Two-line Capacitive Keypad(SDI2) B820 SDI2 Inovonics Interface Module B920 Two-line Alphanumeric Keypad(SDI2) D113 Battery Lead Supervision Module B915/B9151 Basic Keypad(SDI2) D125B Dual Class B Initiating Module Transformers D129 Class A Initiating Module D130 Auxiliary Relay Module CX4010 Plug-in Transformer(18 VAC 22 VA 60 Hz) ICP-TR1822-CAN Plug-in Transformer(110 VAC primary,18 VAC 22 VA D132A Smoke Detector Reversing Relay Module secondary) D133/D134 Relay Module Enclosures D135A Low Battery Disconnect Module 610 Medium Control Panel Enclosure D185 Reverse Polarity Signaling Module 811 Small Control Panel Enclosure D192G Class"B",Style Y Bell Circuit Supervision B12 Mounting Plate for D8103 Enclosure Applications B8103 Universal Enclosure(requires a B12) Remote Programming Software(RPS or RPS-LITE)v6.03 and higher D8108A Attack Resistant Enclosure(requires a B12) Bosch Video Management System v5.5 and higher D8109 Fire Enclosure(requires a B12) Conettix receivers Accessories (Managed and configured with Conettix D6200 Programming/ Administration Software v2.00) B56 Keypad Surface Mount Box Conettix D6600 Communications Receiver/Gateway(with only D6641 B96 Keypad Trim Bezel line cards installed)with CPU version 01.10.00 B99 USB Direct Connect Cable Conettix D6100IPv6 Communications Receiver/Gateway with CPU version 61.10.00 B501-10 Interconnect wiring cables(pack of 10) Conettix D6100i Communications Receiver/Gateway with CPU version Detectors 61.10.00 FCC-380 Carbon Monoxide Detector RADION wireless from Bosch Bosch conventional detectors,including Professional Series,Blue Line B810 wireless receiver(RADION) Gen2,Blue Line,Classic Line,Commercial Line,and Ceiling Mount motion detectors,as well as glass break,seismic,request-to-exit, RFBT-A bill trap photoelectric,heat,and smoke detectors. RFDL 1I A TriTech motion detector Modules RFDW-RM-A recessed mount door/window contact B201 2-wire Powered Loop Module RFDW-SM-A surface mount door/window contact B208 Octo-input Module RFGB-A glass break detector B308 Octo-output Module RFIN-A inertia detector B426 Conettix Ethernet Communication Module RFKF-A two-button keyfob B430 Plug-in Telephone Communicator RFKF-FBS-A four-button keyfob B440 Conettix Plug-in Cellular Communicator(using 3G) RFKF-TBS-A two-button keyfob B441 Conettix Plug-in Cellular Communicator(using CDMA) RFPB-SB-A single-button panic B442 Conettix Plug-in Cellular Communicator(using GPRS)* RFPB-TB-A two-button panic B443 Conettix Plug-in Cellular Communicator(using HSPA+)* RFRP-A repeater B450 Conettix Plug-in Communicator Interface RFSM-A smoke detector B520 Auxiliary Power Supply Module RFPR-12-A PIR motion detector 6 I B5512 Control Panels RFPR-C12-A PIR curtain motion detector 1 Literature CD containing product literature RFUN-A universal transmitter 1 Wiring label for enclosure door Inovonics Wireless 1 Hardware pack • Mounting clips B820 SDI2 Inovonics Interface Module • 1 kf1 EOL resistors • Battery wires ENKIT-SDI2 SDI2 Inovonics Interface and Receiver Kit.Includes B820 • Four#6 x 3/4 in self threading screws and EN4200 EN1210 Universal Transmitter(Single-input) Quant. Component EN1210EOL Universal Transmitter with EOL Resistor 1 Control panel(without on-board Ethernet port) EN1210W Door-Window Transmitter with Reed Switch 1 Plug-in communicator(telephone or cellular,depending on the kit) EN1215EOL Universal Transmitter with Wall Tamper,Reed Switch,and EOL Resistor 1 Plug-in Transformer(18 VAC 22 VA 60 Hz) EN1223D Water-resistant Pendant Transmitter(Double-button) 1 Control panel enclosure(kit dependent) EN1223S Water-resistant Pendant Transmitter(Single-button) 1 Literature pack EN1224-ON Multiple-Condition Pendant Transmitter 1 Literature CD containing product literature EN1233D Necklace Pendant Transmitter(Double-button) 1 Wiring label for enclosure door EN1233S Necklace Pendant Transmitter(Single-button) 1 Hardware pack EN1235D Beltclip Pendant Transmitter(Double-button) Technical specifications EN1235DF Fixed-location Transmitter(Double-button) Communications EN1235S Beltclip Pendant Transmitter(Single-button) Ethernet 10/100 full duplex(N/A for"E" EN1235SF Fixed-location Transmitter(Single-button) control panels) EN1247 Glass-break Detector Transmitter Environmental considerations EN 1249BillTrapTransmitter Relative humidity 5%to93%at+90°F (+32°C), EN1242 Smoke Detector Transmitter non condensing Temperature(operating) +32°F to+122°F(0°C to+49°C) EN1260 Wall Mount Motion Detector EN1261HT High Traffic Motion Detector Number of... EN1262 Motion Detector with Pet Immunity Areas 4 EN1265 360°Ceiling Mount Motion Detector Custom functions 4 EN4200 Serial Receiver Events Up to 255 EN5040-T High Power Repeater with Transformer Passcode users 50,plus 1 Installer passcode *For these cellular modules, check for availability in Points 48(8 on board,up to 40 offboard your region. and virtual) Parts included Programmable outputs 43(3 on-board,up to 40 off-board and virtual) Qty. Component RF points 40 1 Control panel 1 Literature pack IP cameras 4 • UL Installation Guide SKEDs 5 • ULC Installation Guide(English and French) — • Owner's Manual • Release Notes • SIA Quick Reference Guide • Quick Installation Guide 7 I B5512 Control Panels Power Requirements D122 Dual Battery Harness Current draw(maximum) Idle 125 mA;Alarm 155 mA Harness with circuit breaker. Connects two batteries to a compatible control panel. Output(alarm) 1.3 A at 12 VDC Order number D122 Output(auxiliary,continuous 800 mA at 12 VDC nominal D122L Dual Battery Harness with Long Leads power,and switched auxiliary Color-coded harness with circuit breaker and leads combined) measuring 89 cm (35 in.). Connects 12 V batteries to Voltage(operating): 12 VDC nominal compatible control panels. Order number D122L Voltage(AC) CX4010 Plug-in Transformer(18 VAC 22 VA 60 Hz)or D126 Standby Battery(12 V,7 Ah) ICP TR1822 CAN Plug-in A rechargeable sealed lead-acid power supply used as Transformer(110 VAC primary, a secondary power supply or in auxiliary or ancillary 18 VAC 22 VA secondary) functions. Order number D126 Ordering information D1218 Battery(12 V, 18 Ah) B5512 Control Panel A 12 V sealed lead-acid battery for standby and The B5512 is available individually or in kits. auxiliary power with two bolt-fastened terminals. For kits, refer to Quick Selection Guide (B Series Kits) Includes hardware for attaching battery leads or spade on the Documents tab of the control panel's Product connectors Page at us.boschsecurity.com. Order number D1218 Order number B5512 CX4010 Plug-in Transformer B5512E Control Panel For use in North America. 110 VAC primary voltage The 65512E is available only in kits. input. 18 VAC, 22 VA secondary input. For kits, refer to Quick Selection Guide (B Series Kits) Order number Cx4010 on the Documents tab of the control panel's Product ICP-TR1822-CAN Plug-in Transformer Page at us.boschsecurity.com. For use in Canada. 110 VAC primary voltage input. 18 Order number B5512E VAC, 22 VA secondary input. Accessories Order number ICP-TR1822-CAN B520 Auxiliary Power Supply Module B8103 Enclosure Provides auxiliary power to 12 VDC devices or to SDI2 White steel enclosure measuring 41 cm x 41 cm x 9 cm modules. Order number B520 (16 in. x 16 in. x 3.5 in.). Order number B8103 B201 2-wire Powered Loop Module D8103 Enclosure The module provides a single powered initiating device Grey steel enclosure measuring 41 cm x 41 cm x 9 cm circuit. The module supports compatible 12 V 2-wire (16 in. x 16 in. x 3.5 in.). smoke detectors. It also supports connecting burglary Order number D8103 devices to the control panel. Order number B201 D8108A Attack Resistant Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm B208 Octo-input Module (16 in. x 16 in. x 3.5 in.). UL Listed. Includes a lock and Provides 8 programmable inputs. key set. Order number B208 Order number D8108A B308 Octo-output Module D8109 Fire Enclosure Provides 8 programmable relays. Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 Order number B308 cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock RADION receiver SD and key set. Receives RF signals from RADION transmitters, Order number D8109 repeaters, and glassbreaks. Operates at 433.42 MHz. B10 Medium Control Panel Enclosure For use with compatible SDI2 bus control panels. White, steel enclosure. Accepts an optional lock and Order number B810 tamper switch. Measures 35.6 cm x 31.8 cm x 7.6 cm (14 in x 12.5 in x 3 in). Order number Bio 8 I B5512 Control Panels B11 Small Control Panel Enclosure B942W Touch Screen Keypad White, steel enclosure. Accepts an optional lock and White SDI2 touch screen keypad with inputs and one tamper switch. Measures 27.8 cm x 25.9 cm x 8.32 cm output. (10.9 in x 10.2 in x 3.3 in). Order number B942W Order number Bii Software Options B12 Mounting Plate for D8103 Enclosure RPS Software Required for mounting select control panels and other RPS software is available for free download on the devices in D8103, D8108A, D8109, or BATB Battery RPS product page. It is also available on DVD-ROM. Box enclosures. Order number D5500CU Order number B12 Bosch VMS Enterprise Edition D8004 Transformer Enclosure Base license for Enterprise System. 2 Management For applications such as fire alarm that might require a Server subsystems (1 required for Enterprise transformer enclosure. Management); 8 cameras; 2 workstations (1 with Order number D8004 Forensic Search); 1 CCTV keyboard; 1 DVR. All MBV-X* and MBV-F* options are only available with Base D101 Lock and Key Set license. Short-body lock set with one key supplied. Uses the Order number MBV BENT 65 D102 (#1358) replacement key. Order number D101 Bosch VMS Professional Edition Base license for Professional Edition. 8 cameras; 2 D110 Tamper Switch workstations (1 with Forensic Search); 1 CCTV Screw-on tamper switch that fits all enclosures. keyboard; 1 DVR. All MBV-X* and MBV-F* options are Shipped in packages of two. only available with Base license. Order number D110 Order number MBV-BPRO-65 ICP-EZTS Dual Tamper Switch Combination tamper switch with a wire loop for additional tamper outputs. Order number ICP-EZTS B99 USB Direct Connect Cable Male A to Male A USB cable for local programming of control panels with on-board USB ports. Order number B99 B915 Basic Keypad Two-line alphanumeric basic keypad with English function keys. Order number B915 B915I Basic Keypad Two-line alphanumeric basic keypad with icon function keys. Order number B9151 B920 Two-line Alphanumeric Keypad (5D12) Two-line alphanumeric keypad Order number B920 B921C Two-line Capacitive Keypad with Inputs (SDI2) Two-line alphanumeric keypad with inputs and capacitive touch keys in black. Order number B921C B930 ATM Style Alphanumeric Keypad (SDI2) Five-line ATM style alphanumeric keypad Order number B930 B942 Touch Screen Keypad Black SDI2 touch screen keypad with inputs and one output. Order number B942 9 I B5512 Control Panels Represented by: Europe,Middle East,Africa: Germany: North America: Asia-Pacific: Bosch Security Systems B.V. Bosch Sicherheitssysteme GmbH Bosch Security Systems,Inc. Robert Bosch(SEA)Pte Ltd,Security Systems P.O.Box 80002 Robert-Bosch-Ring 5 130 Perinton Parkway 11 Bishan Street 21 5600 JB Eindhoven,The Netherlands 85630 Grasbrunn Fairport,New York,14450,USA Singapore 573943 Phone:+31 40 2577 284 Germany Phone:+1 800 289 0096 Phone:+65 6571 2808 emea.securitysystems@bosch.com www.boschsecurity.com Fax:+1 585 223 9180 Fax:+65 6571 2699 emea.boschsecurity.com onlinehelp@us.bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.asia ©Bosch Security Systems 2016 I Data subject to change without notice 6085453963 I en,V33,29.Jul 2016 Intrusion Alarm Systems I B942 Touch Screen Keypad B942 Touch Screen Keypad www.boschsecurity.com 4Q1) BOSCH Invented for life 0 BOSCH 4 Area 1:Off Full Area Name ► Color graphic touch screen display uses a ®BoscR combination of simple icons and text for easy • operation C Area 1:Off * F Full Area Name ► Built-in presence detector lights the display when Ready to turn all on a user approaches keypad • r • ► Built-in proximity reader allows use of a token or * F 4 R * •.. ;;; * ? 01T, card as replacement for a passcode, or for use with dual authentication for high security areas • U•) ► Four inputs and one output provide cost effective expansion ► Slim, modern design blends with any decor The B942 keypad is an SDI2 bus compatible device. Functions The keypad features an illuminated touch screen and graphical interface. With an elegant design and low Display profile, the keypad fits with any modern decor. Each The touch screen display uses icons, words, numbers, keypad has user adjustable options such as volume and symbols to show the status of the security system and brightness. They have four inputs and one output. and for interacting with the security system. When The keypad shows system messages for all areas. several events occur, the keypad shows each event in order of priority. The keypad detects when a user System overview approaches and automatically activates the display. • For commercial use, install the keypad in building User icons and keys entrances and areas with unrestricted access. The keypad greets the user with a home screen that Mounting a keypad near exterior doors in hotel or shows the system status at one glance using a large business lobbies allows people to identify the type icon. The user can change the system status by simply and location of the emergency. touching this home screen icon. The touch screen • For residential use, install the keypad near the front display also offers icons on the ribbon bar. These and rear entrances to the home. Install additional visually pleasing graphical icons are easy to use for keypads in a kitchen or in a bedroom. accessing menus and other options. The keypad has a • Use multiple keypads in a large building with many variety of keyboards for entering alphanumeric separate areas of security. Program multiple keypads characters. The keypad screen has numeric keys and to control multiple areas. one function [CMD] key. When pressed, keys emit a • Audible tones from the keypad sounder alert muted beep. Use the keyboards for entering personnel to fire events and assist fire fighters in passcodes, activating commands, and entering locating the keypad. alphanumeric characters. 2 I B942 Touch Screen Keypad Audible tones Region Certification The keypad has a built-in speaker that produces several distinct warning tones. The tones are ULC CAN/ULC S545-Residential Fire Warn- differentiated so that the user can recognize an event ing System Control Units simply by hearing its associated tone. The keypad ULC ULC-ORD C1023-Household Burglar backlight illuminates when it emits an audible tone. Alarm System Units Users can use a passcode or credential to silence the ULC ULC-ORD C1076 Proprietary Burglar tone. Alarm Units and Systems Status indicators IC ICES-003-Information Technology The status indicators on the keypad provide a quick Equipment(ITE) visual reference for system status. Installation/configuration notes ,/ The indicator lights when the system is ready to turn on(arm). Power supply O The indicator lights when the system is on(armed). A compatible control panel supplies the power and data requirements to the keypad through a four-wire The indicator lights when there is a trouble condition. connection. 0 Mounting and wiring GAS The indicator lights when dangerous gases are present including Mount in dry indoor locations. carbon monoxide(NFPA 720). Includes a slim mounting plate for recessing wiring, F The indicator lights when the system has power. and a surface mounting plate for surface mounting and wiring. Proximity reader Compatible control panels The proximity reader allows users to use a token or B9512G/B9512G-E card in place of a passcode to turn on or off the B8512G/B8512G-E security system. The proximity reader supports B6512 EM4102 (125 kHz) credentials. The Bosch ACA-ATR13- B5512/B5512E firmware v2.03 and higher RFID tag and Bosch ACD-ATR111SO-RFID card are B4512/B4512E firmware v2.03 and higher examples. B3512/B3512E firmware v2.03 and higher D9412GV4/D7412GV4 v2.03 and higher Certifications and approvals Parts included Region Certification Europe CE EMC,LVD,R&TTE,RoHS Quant. Component USA UL UL 365-Police Station Connected Bur- 1 Keypad glar Alarm Units 2 Mounting plates(slim and surface) UL UL 609-Standard for Local Burglar 1 Hardware pack Alarm Units and Systems UL UL 636-Holdup Alarm Units and Sys- 4 1k 4 EOL Resistors tems 1 Installation Guide UL UL 985-Household Fire Warning Sys- tem Units 1 User's Quick Reference Guide UL UL 1023-Household Burglar Alarm Sys- Technical specifications tem Units UL UL 1076-Proprietary Burglar Alarm Properties Units and Systems Dimensions 6.2 in x 4.7 in x 0.65 in(158 mm x 120 UL UL 1610-Central Station Burglar Alarm mm x 16.5 mm) Units CSFM see our website Weight 11.3 oz(0.32 kg) FCC Part 15 Class B Material Acrylonitrile butadiene styrene(ABS) Poly(methyl methacrylate)(PMMA) Canada ULC CAN/ULC S303-Local Burglar Alarm — UnitsandSystems Display window Touch screen ULC CAN/ULC S304-Standard for Signal Re- Multi-line messages ceiving Center and Premise Burglar — Alarm 3 I B942 Touch Screen Keypad Indicators Power indicator LED Accessories Status indicators B56 Keypad Surface Mount Box Main icon Surface mount box for mounting a keypad to concrete Warning and indicating tones or block. Inputs 4(four)1k 0 supervised inputs Order number B56 Output r1(one)NO(normally open)contact B96 Keypad Trim Bezel Cover the wall footprint of previous keypads when Environmental considerations replacing them with the new, slim design of B Series keypads. The white trim bezel is 8.6 in x 6.3 in x 0.12 Relative humidity 5%to93%at+32°C(+90°F)non- in (22 mm x 16 mm x 3 mm). condensing Order number B96 Temperature(operating) P 0°C to+50°C(+32°F to+122°F) Power requirements Current with proximity Standby:200 mA reader disabled Alarm:300 mA Current with proximity Standby:300 mA reader enabled Alarm:400 mA Voltage(input) 12 VDC nominal Wiring Terminal wire size 18 AWG to 22 AWG(1.02 mm to 0.65 mm) SDI2 wiring with prox Maximum distance-wire size detector disabled (unshielded wire only): 200 ft(61 m)-22 AWG(0.65 mm) 520 ft(159 m)-18 AWG(1.02 mm) SDI2 wiring with prox Maximum distance-wire size detector enabled (unshielded wire only): 150 ft(46 m)-22 AWG(0.65 mm) 390 ft(119 m)-18 AWG(1.02 mm) Inputs and output On-board points voltage Open:2.2 to 5.0 VDC ranges Normal:1.4 to 1.8 VDC Short:0.0 to 1.0 VDC Short circuit current:2.3 mA Relay contact rating 24 VDC,1 A,power factor:1 Ordering information B942 Touch Screen Keypad Black SDI2 touch screen keypad with inputs and one output. Order number B942 B942W Touch Screen Keypad White SDI2 touch screen keypad with inputs and one output. Order number B942W 4 I B942 Touch Screen Keypad Represented by: Europe,Middle East,Africa: Germany: North America: Asia-Pacific: Bosch Security Systems B.V. Bosch Sicherheitssysteme GmbH Bosch Security Systems,Inc. Robert Bosch(SEA)Pte Ltd,Security Systems P.O.Box 80002 Robert-Bosch-Ring 5 130 Perinton Parkway 11 Bishan Street 21 5600 JB Eindhoven,The Netherlands 85630 Grasbrunn Fairport,New York,14450,USA Singapore 573943 Phone:+31 40 2577 284 Germany Phone:+1 800 289 0096 Phone:+65 6571 2808 emea.securitysystems@bosch.com www.boschsecurity.com Fax:+1 585 223 9180 Fax:+65 6571 2699 emea.boschsecurity.com onlinehelp@us.bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.asia ©Bosch Security Systems 2016 I Data subject to change without notice 14472973195 I en,V10,OS.Aug 2016 Intrusion Alarm Systems I B208 Octo-input Module B208 Octo-input Module www.boschsecurity.com �OD B os ci-u Invented for life BOSCH 5 9 At 9 0 t 0308 - 8' 2 B' 2 7.V•3 7,V 3 6'g'4 6'5 4 koHS " „.' TENS ONES "- _ _ - : 77,Ig N Ze7 ► Programmable input point functions num- l2902 • Easy to read switch addressing "44 1'r)r?tilt f,;t, Y , fr,,) ► 2 interconnect wiring connectors • ► Provides eight points iMPR IMIMIMI PWR A B COB 1 COM 2 3 COM 4 5 COM 6 7 COM 8 The B208 Octo-input Module is an 8 point expansion Certifications and approvals device that connects to the control panel through the SDI2 bus. This module is fully supervised and Region Certification communicates back to the control panel all point status changes. The module expansion points operate Europe CE EMC,RoHS B915,B920,8930,6430, B208,6308,6901 the same as the points on the control panel. Industrial, commercial, and institutional facilities are USA UL typical installations for the B208 module. The B208 UL UL 365-Police Station Connected Bur- connects to the SDI2 bus on the control panel using glarAlarm Units SDI2 terminals, or using the interconnect cable. You UL UL 609 Standard for Local Burglar can connect multiple B208 modules to a single control Alarm Units and Systems panel. The B208 address switches allow for ease of use in device addressing. UL UL636-Holdup Alarm Units and Sys- terns System overview UL UL 864-Standard for Control Units and Accessories for Fire Alarm Systems The B208 Octo-input Module connects to a control UL UL 985 panel through the SDI2 bus. This module is supervised Household Fire Warning Sys tem Units and communicates back to the control panel all point status changes. The module's expansion points UL UL 1023-Household Burglar Alarm Sys- operate the same as the points on the control panel. tem Units UL UL 1076-Proprietary Burglar Alarm Functions Units and Systems Loop inputs UL UL 1610-Central Station Burglar Alarm The 6208 uses up to eight inputs which may be Units Normally Open (NO), or Normally Closed (NC) with 1k FM FM 3010-Fire Alarm Signaling Systems C2 EOL resistor(s) for supervision. CSFM see our website 2 I B208 Octo-in put Module Region Certification 111 Environmental considerations • FCC Part 15 Class B Relative humidity 5%to 93%at+32°C(+90°F) FDNY- 6174 Temperature(operating) 0°C to+49°C(+32°F to+120°F) CoA FDNY 6196 Power requirements CoA Current 35 mA Canada ULC CAN/ULC S303-Local Burglar Alarm Units and Systems Voltage 12 VDC nominal ULC CAN/ULC S304-Standard for Signal Re- Wiring ceiving Center and Premise Burglar _ Alarm SDI2 wiring Maximum distance-Wire size ULC ULC-ORD C1023-Household Burglar (unshielded wire only):1000 ft(305 Alarm System Units m)-22 AWG(0.65 mm) ULC ULC-ORD C1076-Proprietary Burglar 1000 ft(305 m)-18 AWG(2 mm) Alarm Units and Systems Unshielded wire only IC ICES-003-Information Technology Loop inputs Equipment(ITE) Loop Inputs Up to eight inputs.Input contacts may Installation/configuration notes be Normally Open(NO)or Normally Closed(NC)with 1kO EOL resistor(s) Wiring considerations for supervision.Note:Normally Closed The module to the control panel using the PWR, A, B, COM terminals on the control panel using the screw (NC)is not permitted in Fire terminal strip or the interconnect wiring connector. installations. Use 12 AWG to 22 AWG (1.5 mm to 0.6 mm) wires Ordering information from the module to the control panel. Compatibility B208 Octo-input Module For UL 864 compliance, use a UL commercial fire Provides 8 programmable inputs. approved control panel. Order number B208 Control panels B9512G/B9512G-E(Up to 59 modules) B8512G/B8512G-E(Up to 9 modules) B6512(Up to 9 modules) B5512/B5512E(Up to 4 modules) B4512/B4512E(Up to 2 modules) D9412GV4(Up to 24 modules) D7412GV4(Up to 7 modules) D7212GV4(Up to 3 modules) Parts included Quantity Component 1 Octo-input module 1 Hardware pack 1 interconnect cable 1 Literature pack Technical specifications Properties Dimensions 2.5 in x 3.8 in x 0.60 in (6.37 cm x 9.6 cm x 1.5 cm) 3 I B208 Octo-input Module Represented by: North America: Europe,Middle East,Africa: Asia-Pacific: China: Latin America and Caribbean: Bosch Security Systems,Inc. Bosch Security Systems B.V. Robert Bosch(SEA)Pte Ltd,Security Bosch(Shanghai)Security Systems Ltd. Robert Bosch Ltda Security Systems Division 130 Perinton Parkway P.O.Box 80002 Systems 203 Building,No.333 Fuquan Road Via Anhanguera,Km 98 Fairport,New York,14450,USA 5617 BA Eindhoven,The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900 Phone:+1 800 289 0096 Phone:+31 40 2577 284 Singapore 573943 Changning District,Shanghai Campinas,Sao Paulo,Brazil Fax:+1 585 223 9180 Fax:+31 40 2577 330 Phone:+65 6571 2808 200335 China Phone:+55 19 2103 2860 security.sales@us.bosch.com emea.securitysystems@bosch.com Fax:+65 6571 2699 Phone+86 21 22181111 Fax:+55 19 2103 2862 www.boschsecurity.us www.boschsecurity.com apr.securitysystems@bosch.com Fax:+86 21 22182398 latam.boschsecurity@bosch.com www.boschsecurity.asia www.boschsecurity.com.cn www.boschsecurity.com ©Bosch Security Systems 2016 I Data subject to change without notice 2536957579 I en,V20,12.Jul 2016 N� s5 GENTEX CORPORATION Combination Photoelectric Smoke G N - 5 0 3 and Carbon Monoxide Alarm 120VAC/9VDC Single/Multiple Station Smoke SERIES and CO Alarm Applications The GN-503 (120VAC/9VDC) Series of combination photoelectric smoke and electrochemical sensor carbon monoxide alarms are for use as evacuation devices in all dwelling units, including but not limited to homes, apartments, hospitals, hotels, motels and other commercial occupancies. The GN-503 Series is listed in compliance with ANSI/UL 217,ANSI/UL 2034, for installation per NFPA 720 and NFPA 72. Available in three models,the GN-503 Series is engineered to virtually eliminate nuisance alarms and deliver outstanding performance wherever reliable smoke and CO protection is required. The GN-503F features one (1)set of Form A/Form C contacts that activate for smoke and/or CO events. THE GN-503FF FEATURES TWO (2) SETS OF FORM N FORM C CONTACTS THAT ACTIVATE INDEPENDENTLY FOR Product Listings SMOKE AND CO EVENTS. Both the GN-503F and GN-503FF provide a connection SIGNALING to a protected premises alarm system to provide a supervisory/trouble signal. gr The GN-503 Series is provided with a 9VDC alkaline battery for electrical back-up in the _ FFs, event building power is lost.The battery impedance is verified and the alarm provides a LISTED 1 low or missing battery warning. The battery drawer provides easy replacement without •ANSI/UL 217 and ANSI/UL 2034 Listed removing the unit from the wall or ceiling. •CSFM#5276-0569:144 The GN-503 Series is designed with a self test feature that quickly notifies if the alarm is Product Compliance functioning properly or needs attention (signified by a series of chirps) by simply pressing the test button. The functionality tests that the smoke/CO alarm is operating properly =MA MEMBER (signified by going into alarm). The self and functionality tests are in compliance with ASSEMBLED IN THE USA NFPA 72, NFPA 720 and ANSI/UL Standards. •NFPA 72 and NFPA 720 The GN-503 Series provides a temporal 3 evacuation tone for smoke alarm annunciation •IBC/IFC/IRC and all units provide a temporal 4 tone for CO alarm annunciation. Per NFPA 720,the •City&State Ordinances/Laws/Regulations temporal 3 evacuation tone for smoke alarm will take precedence over the temporal 4 •Quality Management System is certified tone for CO alarm. to:ISO 9001:2008 Standard Product Features • Mounting hardware adapts to standard junction boxes, • GN-503 available in 120VAC with 9VDC battery back-up including but not limited to 4x4x2-1/8 octagon • Horn frequency 3100 Hz(nominal) • Dust cover to prevent contamination during installation • Meets sensitivity requirements of ANSI/UL 2034 • Low or missing battery indicator • F Model:One (1)set of Form A/Form C contacts that activate • 1 year warranty from date of purchase for smoke and/or CO events • 5 year limited warranty on CO sensor • FF Model:Two(2)sets of Form A/Form C contacts that activate Additional Smoke Alarm Features independently for smoke and CO events • Photoelectric smoke sensing technology • Relay contacts operate on battery back-up • Temporal 3 evacuation sounding pattern for smoke • Push button self test feature annunciation • Push button functional test feature • Nominal 2.5%sensitivity(smoke) • Quick-disconnect wiring harness • Solid state red LED to indicate smoke presence • Non-latching (self restoring)alarm Additional CO Alarm Features • Fully insect protected • Electrochemical sensor • Red LED pulses every 30 seconds, green LED for AC • Temporal 4 sounding pattern for CO annunciation power on • End of life signal indicates CO sensor has reached depletion state and unit must be replaced GN-503 Series Combination Smoke/CO Alarm Model 9VDC Battery One (1) Set Two(2) Sets Number Voltage Back-Up Form A/Form C Form A/Form C Relay Contacts Relay Contacts GN-503 120VAC • GN-503F 120VAC • • GN-503FF 120VAC • • GN-503 AND GN-5O3F Wiring Diagrams QUICK DISCONNECT 1—TYPE PLUG BLK HOT < 11 POWER •• SMOKE ALARM WHT NEUT < 4 I co • I (LEGACY) I • I _ RED/YEL < 4 0 TANDEM - LEGACY I BRN/YEL < 4 0 TANDEM VIO < 4 r TANDEM WIRE I ALARMI (LEGACY) • RED/YEL I SMOKE/CO VIO/BLK < 4 i CONTACTS I ALARM m • k • I n BLU A •< 4 1 ACCESSORY I r ORN < 4 ALARM I- YEL < CONTACTS I • I - a OK /CO 4GRAY mm • < 4 INTERNAL I XQ • I _ GRAY < 4 JUMPER I I TANDEM WIRE PLUG 1 t SMOKE/CO BRN/YEL NEUTRAL/WHITE ► ALARMHOT/BLACK GN-503/GN-503F ADDITIONAL PRODUCT INFORMATION THE GN-503F AND GN-503FF PRODUCT WIRING HARNESS IS NOT INTERCHANGEABLE. THE GN-503F AND GN-503FF MUST USE PROPER WIRING HARNESS. PRODUCT WILL NOT FUNCTION IF INCORRECT HARNESS IS USED. • DO NOT connect Gentex alarms to other manufacturers'alarms. • Per NFPA 72, a maximum of 18 compatible smoke, heat, CO and/or combination smoke/CO alarms may be interconnected.No more than 12 of the 18 can be smoke alarms. • All units connected in tandem MUST get their power from the same circuit,that is, all smoke alarms in tandem must be controlled by the same fuse or circuit breaker. NOTICE: PER NFPA 72,A MAXIMUM OF 12 SMOKE/CO ALARMS OF GN-503 WITH THE RELAY OPTION (F) MAY BE TANDEM INTERCONNECTED. The GN-503/GN-503F may be tandem interconnected with other Gentex tandem capable smoke alarms, CO alarms or smoke/CO alarms. To interconnect with Gentex 9000 Series, 7000 Series, 710CS Series, 7109CS Series, GN-200 Series&GN-300 Series the LEGACY TANDEM WIRE must be used. Refer to installation manual for detailed information. CAUTION: RED/YELLOW&BROWN/YELLOW wire to be capped when not in use.This wire is for tandem connection only.Do not connect to any other circuit. • If a GN-503 Series or C01209 Series unit is annunciating for a CO event, legacy products that are tandem interconnected will not activate and will remain silent. • If smoke alarm portion of device goes into alarm, all smoke alarms, CO alarms or combination smoke/CO alarms tandem wired will sound smoke alarm warning. • When both smoke and CO conditions are present, smoke condition will have priority and alarm will sound smoke annunciation. USING THE GENTEX GN-503FF COMBINATION SMOKE AND CARBON MONOXIDE ALARM ALLOWS THE ABILITY TO: • Interface with a FACP Panel • Interface with NAC Circuits GN-503FF Wiring Diagrams QUICK DISCONNECT r TYPE PLUG I Tfr BLK HOT < 4 • I SMOKE/CO WHT NEUT POWERI corn ALARM x� • • I BRN/YEL < 4 0 TANDEM I • via < 41 SMOKE ALARM r I via < 4 • 1] CONTACTS(FORM A CONTACT) YEL r < 4 SMOKE NORMALLY CLOSED ORN I I SMOKE/CO 4 I SMOKE FORM C COMMON FORM CALARM BLU < 4 I SMOKE&CO NORMALLY OPEN ALARM I o� • I GRAY CONTACTS xp • • 4 - CO FORM C COMMON I a VIO/YEL < • CO NORMALLY CLOSED PINK r < 4 • 1 CO ALARM — PINK < 4 7 CONTACTS(FORM A CONTACT) • I SMOKE/CO ALARM mm • x PLUG t t SMOKE/CO I � ♦ I — ALARM TANDEM WIRE BRN/YEL ► NEUTRAL/WHITE HOT/BLACK GN-503FF ADDITIONAL PRODUCT INFORMATION Use brown/yellow wire to tandem interconnect GN-503FF alarms to additional GN-503 Series, S1209 Series and C01209 Series. NOTICE:THE GN-503FF IS ONLY CAPABLE OF TANDEM INTERCONNECT WITH GN-503 SERIES, C01209 SERIES AND S1209 SERIES. THE GN-503F AND GN-503FF PRODUCT WIRING HARNESS IS NOT INTERCHANGEABLE. THE GN-503F AND GN-503FF MUST USE PROPER WIRING HARNESS. PRODUCT WILL NOT FUNCTION IF INCORRECT HARNESS IS USED. • DO NOT connect Gentex alarms to other manufacturers'alarms. • Per NFPA 72, a maximum of 18 compatible smoke, heat, CO and/or combination smoke/CO alarms may be interconnected. No more than 12 of the 18 can be smoke alarms. • All units connected in tandem MUST get their power from the same circuit, that is, all smoke alarms in tandem must be controlled by the same fuse or circuit breaker. NOTICE: PER NFPA 72,A MAXIMUM OF 12 SMOKE/CO ALARMS OF GN-503 WITH THE RELAY OPTION (FF) MAY BE TANDEM INTERCONNECTED. CAUTION: BROWN/YELLOW wire to be capped when not in use.This wire is for tandem connection only. Do not connect to any other circuit. • If smoke alarm portion of device goes into alarm, all smoke alarms, CO alarms or combination smoke/CO alarms tandem wired will sound smoke alarm warning. • When both smoke and CO conditions are present, smoke condition will have priority and alarm will sound smoke annunciation. GN - 503 SERIES Electrical Specifications Operating Voltage 120VAC, 60Hz Operating Current .045 amps Operating Current(Relay Options) .070 amps Operating Ambient Temp Range 40°F to 100°F(4.4°C-38°C) Alarm Horn Rating 85dBA at 10 feet(3.048 m) Auxiliary Relay(GN-503F) 1 Form A& 1 Form C(0.5 amp) Auxiliary Relay(GN-503FF) 2 Form A&2 Form C(0.3 amp) Size Diameter at base:5.75 in.(14.605 cm) Overall diameter 6.25 in.(16.51 cm) Depth: 1.8 in.(4.572 cm) Secondary Power Source Alkaline 9VDC battery(Duracell®MN 1604) CO Sensing Cell Electrochemical Cell Architect & Engineering Specifications The combination photoelectric smoke and carbon monoxide alarm shall be a Gentex Model GN-503/GN-503F/GN-503FF or approved equal which shall provide at least the following features and functions: 1. Nominal smoke sensitivity shall be 2.5%. 2. The smoke alarm portion of device shall utilize an infrared LED sensing circuit which pulses in 4 to 5 second intervals when subjected to smoke.After 2 consecutive pulses in smoke,the alarm shall activate. 3. The CO alarm shall utilize an electrochemical sensing element with a minimum 5-year life. 4. The carbon monoxide alarm portion of device is adjusted not to detect CO levels below 30 PPM and will not alarm when exposed to constant levels of 30 PPM for 30 days. Per ANSI/UL 2034 requirements,the device will alarm at the following levels:70 PPM CO between 1 to 4 hours, but not less than 1 hour. 150 PPM CO between 10 to 50 minutes. 400 PPM between 4 to 15 minutes. 5. The GN-503 Series device shall have a Duracelll®MN 1604 9VDC alkaline battery as a back-up in the event building power is lost. 6. The 9VDC battery impedance shall be verified by the circuit of the smoke/CO alarm. 7. The alarm shall provide an indicator when the battery is low in power, high impedance or is missing. 8. The CO alarm will provide an audible indicator of 3 quick chirps every 30 seconds at end of life of CO sensor. 9. The sensing chamber shall be fully protected to prevent entrance of small insects,thus reducing the probability of false alarms. 10. The alarm shall include a solid state red color LED that will indicate presence of CO at the unit. 11. The alarm shall include a solid state piezo alarm rated at 85dBA at 10ft. 12. A visual LED monitor(condition indicator) shall slow pulse in normal operation and rapid pulse in alarm (red color) 13. An easily accessible test button shall be provided. Push down on button for 5 seconds causing smoke/CO alarm to activate. If device does not go into alarm,the device is not working properly. 14. The device shall have tandem interconnect capability of up to 12 smoke/CO alarms. 15. The GN-503 and GN-503F alarm shall have the capability to tandem interconnect with all Gentex tandem capable smoke alarms, CO alarms or combination smoke/CO alarms, including 7000/7003 Series, 9000/9003 Series, 710CS/713CS Series, 7109CS/7139CS Series, GN-200/GN-300 Series, S1209 Series and C01209 Series. 15. The GN-503FF alarm shall have the capability to tandem interconnect with the following Gentex alarms, CO alarms or combination smoke/CO alarms:GN-503 Series, S1209 Series and C01209 Series. 16. The manufacturer shall provide models with the optional feature of auxiliary Form A/Form C relay contacts for initiating remote functions and annunciation and a relay option that is capable of activation by tandem interconnect wire. 17. The combination smoke/CO alarm shall be non-latching (self-restoring). 18. Unit must be ANSI/UL 217 and ANSI/UL 2034 listed for both wall and ceiling mounting. 19. Unit shall be listed by Underwriters Laboratories and California State Fire Marshal (CSFM). All equipment shall be completely factory assembled,wired and tested,and the contractor shall be prepared to submit a certified letter testifying to this condition. Alarms which do not meet all of the requirements of this specification will not be considered. 24 units per carton For complete product specifications, refer to product installation manual. 24 pounds per carton Important Notice: G E N T E X These materials have been prepared by Gentex Corporation("Gentex")for informational purposes only, 551-0073-04 1-0073-04 are necessarily summary,and are not purported to serve as legal advice and should not be used as CORPORATION cuch.omp Gtearesnd makes e, representations in and warranties,express nr implied,a, thet thesefmaterials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regu- lations and rules.The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws, Fire Protection Products Group•www.gentex.com egulations and rules to particular fact patterns.Each person's activities can differently affect the 10985 Chicago Drive •Zeeland, Michigan 49464 obligations that existunder applicable laws,regulations or rules.Therefore,these materials should be g g used only for informational purposes and should not be used as a substitute for seeking professional 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax legalmadvnnef G an=hhot bearesponsible for any action or failure to act in reliance upon the DN-6927:A2 FCPS-24S6(C/E) & FCPS- 24S(C E) NOTIFIER 6- & 8-Amp 24-Volt by Honeywell Remote Power Su• .lies Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger.The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries.The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as ' - • either four Class B (Style Y) or Class A(Style Z, with ZNAC-4 option module). Alternately, the four outputs may be config- - ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C&FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features • UL-Listed NAC synchronization using System Sensor, • Includes integral battery charger capable of charging up to Wheelock,or Gentex"Commander2"appliances. 18 AH batteries. Cabinet capable of housing 7.0 AH batter- • Operates as a "sync-follower" or as a "sync-generator" ies. (default). See note on page 2. • Battery charger may be disabled via DIP switch for applica- • Contains two fully-isolated input/control circuits - triggered tions requiring larger batteries. from FACP NAC (NAC expander mode) or jumped perma- • Fixed, clamp-type terminal blocks accommodate up to 12 nently"ON"(stand-alone mode). AWG (3.1 mm2)wire. • Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. Specifications • 6-amp (FCPS-2456) or 8-amp (FCPS-24S8) full load out- Primary(AC)Power: put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • FCPS-24S6C/-24S8C: 120 VAC, 60 Hz,3.2A maximum. • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • FCPS-24S6E/-24S8E: 240 VAC, 50 Hz, 1.6A maximum. output in stand-alone mode(UL 1481). • Wire Size: minimum#14 AWG (2.0mm2)with 600 V insula- • Compatible with coded inputs;signals passed through. tion. • Optional power-supervision relay(EOLR-1). Control Input Circuit: • In stand-alone mode, output power circuits may be config- • Trigger Input Voltage: 9 to 32 VDC. ured as: resettable, (reset line from FACP required), • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 non-resettable,or a mix of two and two. - 16 V). • Fully regulated and filtered power output-optimal for pow- Trouble Contact Rating: 5 A at 24 VDC. Bring four wire smoke detectors, annunciators, and other Auxiliary Power Output: Specific application power 500 mA system peripherals requiring regulated/filtered power. maximum. • Power-limiting technology meets UL power-limiting require- ments. Output Circuits: • Form-C normally-closed trouble relay. • +24 VDC filtered, regulated. • Fully supervised power supply,battery,and NACs. • 3.0 A maximum for any one circuit. • Selectable earth fault detection. • Total continuous current for all outputs(stand-alone mode): • AC trouble report selectable for immediate 2-hour delay. —FCPS-2456: 4.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- —FCPS-2458: 6.0 A maximum. lizes an industry-standard reverse-polarity notification cir- • Total short-term current for all outputs(NAC expander mode): cuit(including unfiltered and unregulated NAC power). —FCPS-24S6: 6.0 A maximum. • Requires input trigger voltage of 9-32 VDC. —FCPS-24S8: 8.0 A maximum. • Self-contained in compact, locking cabinet- 15"H x 14.5"W Secondary Power(Battery)Charging Circuit: x 2.75"D(cm:38.1 H x 36.83W x 6.985D). • Supports lead-acid batteries only. DN-6927:A2•5/17/13—Page 1 of 2 • Float-charge voltage: 27.6 VDC. Standards and Codes • Maximum current charge: 1.5 A. The FCPS-24S6 and FCPS-24S8 comply with the following • Maximum battery capacity: 18 AH. standards: • NFPA 72 National Fire Alarm Code. Applications • UL 864 Standard for Control Units for Fire Alarm Systems Example 1: Expand notification appliance power an additional (NAC expander mode). 6.0 A (FCPS-2456) or 8.0 A (FCPS-24S8). Use up to four • UL 1481 Power Supplies for Fire Alarm Systems. Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example,the FACP notification appliance Agency Listings and Approvals circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the These listings and approvals apply to the modules specified in FACP through the notification appliance circuit. this document. In some cases,certain modules or applications Example 2: Use the FCPS to expand auxiliary regulated 24- may not be listed by certain approval agencies, or listing may volt system power up to 4.0 A (FCPS-2456) or up to 6.0 A be in process. Consult factory for latest listing status. (FCPS-2458). Both resettable and non-resettable power • UL Listed: S635, S674 options are available. Resettable outputs are created by con- • ULC Listed: S635(FCPS-24S6C&FCPS-24S8C) necting the resettable output from the FACP to one or both of • CSFM Approved: 7315-0028:225 the FCPS inputs. • Example 3: Use addressable control modules to activate the MEA: 299-02-E FCPS instead of activating it through the FACP notification • FM Approved appliance circuits.This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding Ordering Information system architecture in various applications. FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. For example, an addressable control module is used to acti- Includes main printed circuit board, transformers, enclosure vate the FCPS, and an addressable monitor module is used to (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and sense FCPS trouble conditions. Local auxiliary power output installation instructions. from the FCPS provides power to the addressable control FCPS-24S6C: Same as above, ULC-listed. module. *NOTE: Addressable FACPs are capable of locating control and FCPS-24S6R: Same as FCPS 2456 with red enclosure. monitor modules at distances of up to 12,500 feet(3,810 meters). FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure Sync Follower/Generator Note (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and installation instructions. In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. FCPS 2458: 8.0 A, 120 VAC remote charger power supply. Strobes accomplish this by monitoring very short timing pulses Includes main printed circuit board, transformers, enclosure on the NAC power which are created by the FACP. When (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and installed at the end of a NAC wire run, the FCPS-24S6/-2458 installation instructions. can track (i.e. "follow") the strobe synchronization timing FCPS-24S8C Same as above, ULC-listed. pulses on the existing NAC wire run.This maintains the overall FCPS-24S8R: Same as FCPS 2458 with red enclosure. system flash timing of the additional strobes attaches to the FCPS. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. When the FCPS-24S6/-24S8 is configured(via DIP switch set- Includes main printed circuit board, transformers, enclosure 5"W tings) as a "sync follower," the FCPS's NAC outputs track the (15"H x on inst x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and strobe synchronization pulses present at the FCPS's sync installation nstructions. input terminal.The pulses originate from an upstream FACP or ZNAC-4: Class A(Style Y) NAC option module. other power supply. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire When the FCPS-24S6/-24S8 are configured (via DIP switch smoke detector power. settings) as a "sync generator," the FCPS's sync input termi- BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT nals are not used. Rather, the FCPS is the originator of the Series data sheet DN-6933). strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator"mode,the sync type (System Sensor, Whee- lock,or Gentex) is selectable via DIP switch settings. System Sensor®and NOTIFIER®are registered trademarks of Honeywell International Inc. 02013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. C E RT F E We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6927:A2•5/17/13 DN-6933:D•E-205 BAT Series Batteries NOTI F 1 E R° Sealed Lead-Acid by Honeywell Power Supplies General BAT Series Batteries are Power-Sonic brand batteries. BAT Series (or Power-Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features • Provide secondary power for control panels. 1117- • Sealed and maintenance-free. • Overcharge protected. 6933cov.jpg • Easy handling with leak-proof construction. • Ruggedly constructed,high-impact case(ABS). • Long service life. Ordering Information • Compact design. BAT-1250-BP: 10-unit bulk pack of BAT-1250(12 V 5 AH). Agency Listings and Approvals BAT-1270-BP:5-unit bulk pack of BAT 1270(12 V 7 AH). BAT-12120-BP:4-unit bulk pack of BAT-12120(12V 12 AH). The listings and approvals below apply to BAT Series Batter- BAT-12180-BP:2-unit bulk pack of BAT 12180(12 V 18 AH). ies. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consult BAT-12260-BP:2-unit bulk pack of BAT-12260(12 V 26 AH). factory for latest listing status. BAT-12550:single battery(12 V 55 AH). • UL Recognized Components: MH20845(Power-Sonic). BAT-121000:single battery(12 V 100 AH). Part Number Reference & Specifications Battery DIMENSIONS Description Part Power- Number Sonic Part Nominal Width Depth Height Height over Weight Number Nominal Capacity terminal Voltage V @ 20 hr. rate A.H. in. mm in. mm in. mm in. mm lb. kg. BAT-1250 PS-1250 12 5 sealed 3.54 90 2.76 70 3.98 101 4.21 107 3.50 1.59 BAT-1270 PS-1270 12 7 sealed 5.95 151 2.56 65 3.7 94 3.86 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 5.95 151 3.86 98 3.7 94 3.94 100 7.92 3.59 BAT-12180 PS-12180 12 18 sealed 7.13 181 3.00 76 6.59 167 6.59 167 12.6 5.72 BAT-12260 PS-12260 12 26 sealed 6.5 167 6.97 177 4.92 125 4.92 125 17 7.71 BAT-12550 PS-12550 12 55 sealed 9.04 230 5.45 138 8.15 207 8.98 228 36 16.33 BAT-121000 PS-121000 12 100 sealed 12 305 6.6 168 8.15 207 8.98 228 68 30.84 DN-6933:D•02/28/2013-Page 1 of 2 Discharge Characteristic Curves at 20°C (68°F) Effect of Temperature on Capacity For 6V For 12V Battery Battery 120 ss - 13.0 0.05 C 110 ............ 0.10 c 0.25 C y 6.0 — 12.0 • 80 0.50 C e2 .......... 0.05° to ••• 1 C 55 — 11.0 .14C C 111 20C - 60 To 0.40C .•'' - e so 10.0 - 0.60C . - - E a 40 2C _IC.,. C/ 'm ii 4.5 — 9,0 - 3C/____ - - - •m 20 — z 't m M 0 8 r Co -40 -30 -20 -10 0 10 20 30 40 50 60 1 2 4 6 8 10 20 46 60 2 4 6 810 20 li Minutes rr Hours N Temperature(°C) Discharge Time PS-121000 Shelf-Life and Storage — 100 Charging is not necessary unless O 100%of capacity '0 is required. nd ry 80 5•C Charging before c use is necessary O (41°F)— to help recover full capacity. aa)• 60 ai ` �� Charge may fail � ` to restore full w 40°C 30°C 20°C capacity.Do not ., u 40 (104°F) (86°F) (68°F) let batteries reach m o I I I this state. S9 ( oI to o 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) PS-121000 Discharge Characteristics 14.0 I I I I I I I I I I Ambient Temperature 20°C(68°F 13.0 __- 12.0 __ IIIII i 0 11.0 IIIIIII ,1'` To 10.0 10 5.0 _ 20 H 9.0 50 Final 100 Voltage 8.0 I I 1200 . 2 i 1.2 2.4 6 12 24 36 481 2 4 6 8 10 20 4 0 1.-- ht n _H h ►I Discharge Time NOTIFIER®is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E RT t F E R We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6933:D•02/28/2013 DN-60804:A SpectrAlert® AdvanceTM NOTIFIER® Selectable-Output Low Frequency Sounders & Sounder Strobes by Honeywell Audio Visual Equipment General The SpectrAlert® AdvanceTM series offers the most versatile and easy-to-use line of low frequency sounder and low fre- quency sounder strobes in the industry. With white and red plastic housings, dual listed for wall and ceiling mounting, SpectrAlert Advance can meet virtually any application requirement. - — Like the entire SpectrAlert Advance product line,all-mount low frequency sounder, and low frequency sounder strobes — — include a variety of features that increase their application ver- satility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the black box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from con- F .# struction damage,SpectrAlert Advance use a universal mount- # �� I � 1.' I ing plate with an onboard shorting spring,so installers can test „'�- •wiring continuity before the device is installed. R ( f z_ R E E E E Installers can also easily adapt devices to suit a wide range of application requirements using field-selectable candela set- tings, automatic selection of 12 or 24-volt operation, and a rotary switch for low frequency sounder tones. Features • Plug-in design with minimal intrusion into the back box. • Tamper-resistant construction. shall have field-selectable candela settings including 135, 150, • Field-selectable candela settings on wall units: 135, 150, 177, and 185. 177, and 185. LOW FREQUENCY SOUNDER • Rotary switch for low frequency sounder tone. The low frequency sounder and the Sync•CircuitTM MDL3 • Universal mounting plate for wall units. Module accessory, if used,shall be powered from a notification • Mounting plate shorting spring checks wiring continuity appliance circuit output and shall operate on a nominal 12 or before device installation. 24 volts (includes fire alarm panels with built in sync). When • Electrically compatible with legacy SpectrAlert Advance used with the Sync•CircuitTM MDL3, 12-volt rated notification devices. appliance circuit outputs shall operate between 8.5 and 17.5 • Compatible with MDL3 sync module. volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances • Listed for ceiling or wall mounting. are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing Architect/Engineer Specifications of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between tem- GENERAL poral three pattern, non-temporal (continuous) pattern and SpectrAlert Advance low frequency sounder and low fre- coded supply. The low frequency sounder shall operate on a quency sounder strobes shall mount to a standard 4x4x1-1/2" coded or non-coded power supply. back box, 4-inch octagon back box, or double-gang box. Two- wire products shall also mount to a single-gang 2x4x1-7/8° LOW FREQUENCY SOUNDER STROBE COMBINATION back box. A universal mounting plate shall be used for mount- The low frequency sounder strobe shall be approved for fire ing products. The notification appliance circuit wiring shall ter- protective service. The low frequency sounder strobe shall be minate at the universal mounting plate. Also, SpectrAlert wired as a primary-signaling notification appliance and comply Advance products, when used with the Sync•CircuitTM Module with the Americans with Disabilities Act requirements for visi- accessory, shall be powered from a non-coded notification ble signaling appliances, flashing at 1 Hz over the strobe's appliance circuit output and shall operate on a nominal 12 or entire operating voltage range.The strobe light shall consist of 24 volts. When used with the Sync•Circuit Module, 12-volt- a xenon flash tube and associated lens/reflector system. The rated notification appliance circuit outputs shall operate sounder shall have an option to switch between a temporal between 8.5 and 17.5 volts;24-volt-rated notification appliance three pattern and a non-temporal (continuous) pattern. These circuit outputs shall operate between 16.5 and 33 volts.lndoor options are set by a multiple position switch. The low fre- SpectrAlert Advance products shall operate between 32 and quency sounder on low frequency sounder strobe models shall 120 degrees Fahrenheit from a regulated DC or full wave recti- operate on a non-coded power supply. fied unfiltered power supply. Low Frequency Sounder strobes DN-60804:A•5/21/2014—Page 1 of 4 SYNCHRONIZATION MODULE Nominal Voltage Range Low Frequency Sounder Strobe: The module shall synchronize SpectrAlert strobes at 1 Hz and Regulated 24 VDC/FWR low frequency sounder at temporal three.Also,while operating Operating Voltage Range: 8 to 17.5V(12V nominal) or 16 to the strobes, the module shall silence the low frequency 33 V(24 V nominal). sounder on low frequency sounder strobe models over a sin Operating Voltage Range MDL3 Sync Module: 8.5 to 17.5V gle pair of wires. The module shall mount to a 1-11/16x4-11/ (12V nominal)or 16.5 to 33 V(24 V nominal). 16x2-1/8-inch back box. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The Input Terminal Wire Gauge: 12 to 18 AWG. module shall synchronize multiple zones. Daisy chaining two Wall-Mount Dimensions(including lens): 6.4 inches L x 4.7 or more synchronization modules together will synchronize all inches W x 2.5 inches D (162mm L x 119mm W x 64mm D). the zones they control. The module shall not operate on a coded power supply. Sounder Dimensions: 5.6 inches L x 4.7 inches W x 1.3 inches D(142mm L x 119mm W x 33mm D). Physical/Electrical Specifications Low Frequency Sounder/Strobe with Surface Mount Back Box Dimensions (SBBR, SBBW): 6.4 inches L x 4.7 inches Standard Operating Temperature: 32°F to 120°F (0°C to W x 4.3 inches D(162mm L x 120mm X x 108mm D). 49°C). Low Frequency Sounder with Surface Mount Back Box Humidity Range: 10-93%non-condensing. Dimensions(SBBR,SBBW):5.7 inches L x 4.8 inches W x 3 Strobe Flash Rate: 1 flash per second. inches D(145mm L x 120mm X x 76mm D). Nominal Voltage Low Frequency Sounder: Regulated 12 DC/FWR or regulated 24 DC/FWR. UL Current Draw UL MAXIMUM STROBE CURRENT DRAW(MA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR 135 N/A N/A 228 207 High Candela 150 N/A N/A 246 220 Range 175 N/A N/A 281 251 185 N/A N/A 286 258 UL MAXIMUM LOW FREQUENCY CURRENT DRA(MA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL MAXIMUM CURRENT DRAW (MA RMS), 2-WIRE LOW FREQUENCY SOUNDER STROBE, HIGH CANDELA RANGE (135 - 185 CD) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 277 292 325 344 Temporal 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Page 2 of 4—DN-60804:A•5/21/2014 Low Frequency Sounder Tones and Sound Output Data LOW FREQUENCY SOUNDER AND LOW FREQUENCY SOUNDER STROBE OUTPUT(DBA) 24-Volt Nominal 8-17.5 16-33 Reverberant Anechoic Volts Volts Switch Sound DC FWR DC FWR DC FWR DC FWR Position Pattern 1 Temporal 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3* Coded 80 80 80 80 80 80 90 90 *Sounder ratings provided are for continuous voltage as provided by the NAC, Agency Listings and Approvals These listings and approvals below apply to the SpectrAlert Advance series. In some cases, certain modules or applica- tions may not be listed by certain approval agencies, or listing may be process.Consult factory for latest listing status. • UL Listed: S4011, S5512 • CSFM: 7135-1653:0223 (HR-LF, HW-LF), 7125-1653:0224 (P2HR-LF, P2WH-LF) • FM: 3047563 Ordering Information P2RH-LF: 2-wire wall low frequency sounder strobe, High cd, red. P2WH-LF:2-wire wall low frequency sounder strobe, High cd, white. HR-LF: low frequency sounder, red. HW-LF: low frequency sounder,white. BBS-2: back box skirt,wall red. BBSW-2: back box skirt,wall,white. SBBR: surface mount back box,wall, red. SBBW:surface mount back box,wall,white. TR-HS:trim ring,wall, red. TRW-HS:trim ring,wall white. NOTE: "High cd" refers to strobes that include 135, 150, 177 and 185 candela settings. DN-60804:A•5/21/2014—Page 3 of 4 Notifier®and SpectrAlert®are registered trademarks of and SpectrAlert® AdvanceTM is a trademark of Honeywell International,Inc. ©2014 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E RT t F E D We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60804:A•5/21/2014