HomeMy WebLinkAboutA16-0052_5357-McDonalds FA r1 4_1478896666.pdf -11111 POTTER PFC-60 The Symbol of Protection FIRE ALARM CONT ojAim'ad, Features Vail Fire&Emergency Services • 75 Analog/Addressable Points in Any Con-SWAMI • 5 Amp Power Supply • 4 NACS,2 Regulated,Rated at 3 Amps each&2 Input/Output (I/O)Circuits rated at 1 Amp each • Strobe Synchronization and System Wide Sync for Potter/ AMSECO®,Gentex®,Cooper Wheelock@ and System Sensor® strobes • 99 Software Zones • Large LCD and Keypad for Ease of Operation • Cabinet with enclosure rather than cabinet will house 8 or 18 AH 6075 batteries.Dead Front Cabinet for Clean Look. PF�°Fire A, Smoke Detector Drift Compensation and Maintenance Alerts OPCmesvmbAddressa P 0 `"'°" • NFPA 72 Compliant Smoke Sensitivity Test Built-In • System wide Class A or Class B • 1,000 Event History Buffer • Optional two line DACT(UD-1000) • P-Link Communication Line for Annunciators and Accessories ® v•,; • Ethernet Port for Programming and Network Connectivity NYC Fire Det.p • E-Mail System Status,Reports,and Event Information 1" l Certificate of Approval • Integrated,Listed IP Communicator S735 7165-0328:0195 6157 • Size(W x H x D): 16"x 17"x37/8" Product includes a 5 year warranty Electrical Specs:AC Mains Battery: • 3.0 Amps @ 120 VAC 50/60 H2 • 130 mA Standby • 2.0 Amps @ 240 VAC 50/60 H2 • 220mA Alarm Description The PFC-6075 is a versatile seventy-five(75)point analog/addressable fire alarm control panel that utilizes the Potter/Nohmi device protocol that has a complete line of initiating and control devices.The SLC is capable of 50 ohms of resistance and does not require the use of twisted or shielded wire.The signaling line circuit may be any combination of smoke sensors,heat detectors or modules. The PFC-6075 has a metal cabinet with a key lock and a dead front standard.The cabinet will house 8 Ah or 18 Ah batteries.The large viewing window allows easy viewing of the LCD and the standard LEDs.The keypad allows easy operation and navigation of the system menu. The panel has a 5 amp power supply with two(2)notification circuits each rated at 3 amps and two(2)Input/Output(I/O)circuits each rated at 1 amp.All of the outputs are power limited,power regulated and may be programmed for Potter/AMSECO,Gentex®,CooperWheelock®and System Sensor@ strobe synchronization.The outputs may be configured for any combination of strobe brands and all will sync.The outputs also may be configured for door holder power,auxiliary power and constant power. The panel has auto-programming learn mode that will not affect the existing system when adding or deleting a device.The system is capable of 99 software zones,cross zoning and counting zones.The panel is fully programmed from a PC based software program that will work with Microsoft XP,Vista or Windows 7.0 operating systems. The PFC-6075 has an Ethernet connection for programming network connectivity and IP reporting communicator.The system uses a simple patch cable for connecting a PC to the panel.In addition,the system may be connected to a building network and programmed while on the network.The system has a built in e-mail function and will send system E-mail reminders.The IP communicator is listed with the Sur-Gard III IP receiver. The panel will support P-Link devices which include:the RA-6075,RA-6500 and LED-16 Annunciators,RLY 5 Relay Module,SPG-1000 Se- rial Parallel Gateway(printer card),FCB-1000 Remote Ethernet/IP connection(only 1),DRV-50 LED driver for 50 LEDs,PSN-1000 Remote Power Supplies(10 Amp)and FIB-1000 P-Link Fiber Interface Module.In addition,the panel allows for the installation of the UD-1000 dual line telephone line digital alarm communicator transmitter(DACT).The UD-1000 is programmable for a single line or dual line and is compat- ible with Ademco's Contact ID or SIA DCS protocols.The UDACT will report general,zone,or point The complete system may be converted to Class A with a CA-6075 module.The CA-6075 provides the hardware necessary to convert the re- mote annunciators through the Potter P-Link connection protocol,the NACs and the SLC to Class A operation. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8830001-REV C PAGE 1 OF 3 11/13 olti OF IA P POTTER PFC-6075 The Symbol of Protection FIRE ALARM CONTROL ojAim SLC Loop Accessories Vail Fire&Emergency Services The control panel may be connected with up to seventy-five(75)addressable devices or modules in any combination.The SLC QssRnestricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135°Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135°F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that is mounted to an electrical box and wired for connection of one of the above sensors AIB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call.The sounder follows the pattern sent to the device. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel.Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module switches monitored power and is activated by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors. SCI Short Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. P-Link Devices Device Description RA-6075 LCD/keypad remote annunciator with a metal enclosure and key lock. RA-6500 160 Character LCD.Keypad remote annunciator with metal enclosure and key lock. LED-16 LED remote annucniator capable of displaying alarms,supervisory,and trouble status for 16 zones. PSN-1000 10 Amp Intelligent power supply. RLY-5 5 Form C Relay Card. SPG-1000 Serial/Parallel Printer Card,Optional Rack Mount. FCB-1000 Fire Communications Bridge, 1 may be added for remote IP Communicator. FIB-1000 Fiber Interface Module,used in pairs to convert P-Link over multimode fiber,optional rack mount. PRINTED IN USA MKT.#8830001-REV C PAGE 2 OF 3 11/13 IJ 146 l •W P POTTER PFC-60 i 11. ® The Symbol of Protection FIRE ALARM CONT ]-1120 # :"..---0 Ethernet SLC Circuit Diagram Vail Fire&Emergency Services ' .414111 09/22/16 " UD-1000 •:• RA-6075 I • P 14, r Digital Alarm - -� r C LCD Annunciator - - - Communicator �O°_ • ` Alarm Monitoring 6', ,i ,1 eoo Station t I RA-6500 �-; ( Tnk LCD Annunciator •gr.'pr�r.1,-,p., NACs ce: ' SLC CS/CHS Selectable Candela lllh1/4° Ceiling Mount Stobe or AE-8 Strobe/Hornc 8 Device 3 Amp NAC 110C Expansion Enclosure Circuits 0112611.1111 RLY-5 S-24/HS-24 Relay Expander e��} Selectable Candela _ t Strobe or Strobe/Horn �_ I "' Input/Output(I/O) R E Circuits PFC-6 QVQT� „... SLC Loop :::::o, 0 • •f PSHA Heat Detector FHA Smoke Detector -,:rI4P11.' Heat Detector /Heat Detector = * H 1 pliTRM-4 . —` ; MOM-4 ; DCM-4 . .' SCI Twin Relay •• Monitored Output .. Dual Contact . Short Circuit Module I•m;;., Module Module Isolator CIZM-4 „ SCM-4 , MCM MO” APS-SA .• Conventional .. _ Single Contact Miniature Contact Initiating . - Module POLI o0va Addressable .. ', Module Zone „ : Module _ 1 Pull Station - -- PS-24 CO-12/24 / ) Smoke Detector Carbon Monoxide • Detector PRINTED IN USA MKT.#8830001-REV C PAGE 3 OF 3 11/13 ZoLvispirlo A P POUERiIMiPHOTOELESRI451 1n The Symbol of Protection SENSOR Wj Vail Fire&Emergency Services Features 09/22/16 • Low profile,less than 2 inches with the base • Wide selectable sensitivity range of 1.05 to 3.82%/foot • Sensor communicates sensitivity to control panel 0 • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple and accurate address setting without mechanical switches • LEDs for 360°viewing C US t 0%( LISTED 1>�I S24776 7165-0328:0194 Product includes a 5 year warranty Description Before connecting a device to the SLC loop,take the following The Photoelectric Smoke Sensor is a listed Analog Addressable smoke precautions to prevent potential damage to SLC or device.Verify the sensor compatible with any fire alarm control panel that has the Potter/ following: Nohmi protocol.The PSA is a low profile smoke sensor with a wide 1. Power to the device is removed sensitivity range.The sensor and base(not included)are made of a 2. Field wiring is correctly installed. durable plastic in an eggshell white to blend in with the ceiling. 3. Field wiring has no open or short circuits. The PSA has a sensitivity range of 1.05 to 3.82%per foot and is UL Document discrepancies and notify appropriate personnel. and cUL listed.The PSA may be configured for drift compensation and has built in dirty detector warning as well as.The PSA and Specifications the control panel communicate over a proven and robust digital communication path and the system analyzes the level of alarm at the Item PSA particular device.The total polling speed is less than five(5)seconds, Working voltage range 22.0 to 24.0 V well under the UL requirements. Standby current 325µA The PSA has two LEDs that allow for 360°viewing.The sensor is Alarm indicator 2 LEDs compatible with any of the Potter/Nohmi bases and simply twists on. Alarm indicator current 1.2 mA D.C. The PSA is addressed using the hand held programmer or the control Alarm set-point range 1.05 to 3.82%/ft /3.4 to 12.0%/m panel addressing function. Installation temperature range 32 to 120°F/ 0 to 49°C Air Velocity Ratings Operating relative humidity 0%to 93%(Non-condensing) The PSA has an Open Area of Protection air velocity rating of 0 to 300 range feet per minute. Start-up time Max. 1 sec. Maximum number of 127 The system has a maximum of 13 LEDs that can be turned on addresses per loop simultaneously.If the system already has 13 LEDs on,the PSA will Maximum number of lighted 113 operate even though the LED will not illuminate. indicators in alarm per zone. Color Eggshell White Setting the Address Weight(without base) 84g(2.96oz) Each addressable module,smoke sensor,heat detector and Dimensions(without base) Height: 1.33 in(34mm) combination sensor/detector must have the address set before Diameter:4.0 inches(99mm) connecting the device to the SLC loop.The address is set using the hand held device programmer or the addressing feature on the control Approvals/Listings UL,cUL,CSFM panel. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada:888-882-1833•www.pottersigial.com PRINTED IN USA MKT.#8830015-REV C PAGE 1 OF 2 06/13 .4pAproie: Zohb.‘tib P POTTERiMW® PHOTOELECTRIC RIC S The Symbol of Protection SENSOR 9,� si‘ Operation Vail Fire&Emergency Services 09/22/16 The PSA is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel.The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will latch steady if the unit is in an active status. The PSA is a proven design being in service throughout the world.The PSA with the AB-4 or AB-6 base has a low profile of less than two(2) inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the entire unit can be cleaned with a simple vacuum. Sensor Sensitivity The PSA and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor com- pensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to be cleaned or replaced. Anytime the PSA is being polled,the sensitivity may be viewed or printed from the control panel. Note:As required by NFPA,do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors have been installed in a construction environment,they should be cleaned or replaced before the system is placed into service. Spacing The PSA is UL/ULC listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing,placement and special applications. Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description AB-4 4"Standard Base AB-6 6"Standard Base AIB 6"base with an isolator module included.The base is pre-wired with a pluggable jumper to the module. ARB 6"base with a dual relay module included.One relay is rated for 8 amps at 240 VAC/30 VDC and the second is rated for 2 amps at 240 VAC/30 VDC.The base is pre-wired with a pluggable jumper to the module. ASB 6"base with sounder module included.Sound pattern is provided from external source.The base is pre-wired with a pluggable jumper into the module. PRINTED IN USA MKT.#8830015-REV C PAGE 2 OF 2 06/13 (4OF1/4/ P POTTER Addressab The Symbol of Protection Singl , oj 055 Features Vail Fire&Emergency Services 09/22/16 • Single or Dual Action versions • Durable die-cast construction . • Reset key matches the fire alarm control panels 4 flqqt 'LAR [IR LA RM • Compatible with all PFC-6000 PFC-8000 and P Series panels • Product includes a 5 year warranty LIFTDOW N Stock Numbers & PILI. • APS-SA Addressable Pull Station,Single Action–1430810 �� • APS-DA Addressable Pull Station,Dual Action–1430811 p U ©OTTER ()POTTER 1 C ® US ®eR� LISTED 7150-0328:0201 S25236 Application Technical Specifications The APS-SA/DA is compatible with Potter's PFC-6000 series and Operating Voltage 22.0–24.0 VDC PFC-8500 addressable fire alarm control panels. It is a non-coded addressable pull station available in either a single or dual action Max SLC Standby Current 0.325mA model and installs on a single box or surface mounts using the P32-BB Max SLC Alarm Current 0.325mA or P32-DBB(deep)back box. 32°F- 120°F(0°-49°C) Environmental Limitations Description Indoor Only The APS-SA(Single Action)is activated by simply pulling the white Dimensions 4.75"H x 3.25"W x 1.75"D "T" bar handle down. The APS-DA (Dual Action) is activated by Relative Humidity Range 0-93%(non-condensing) lifting the front cover and then pulling the white"T"bar handle down. — Once activated,the"T"bar cannot be reset without opening the front Single gang box or p g Mounting Options cover. Opening the front cover will also activate the pull station. To Potter P32-BB/DBB reset the APS Series,use the Potter WS-93 key to unlock and open the APS-SA- 1.22 lbs. front cover. Once the cover is open,push the"T"bar back into the Shipping Weight normal position and re-secure the front cover. APS-DA- 1.46 lbs. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830052-REV B • 10/14 PAGE 1 OF 2 o OF P4, AP d'iiii101.1''' et POTTER Addressab• The Symbol of Protection Singl1 , ' 1g0]% Setting the Address Vali1ee&Emergency Services 09/22/ The APS Series uses one SLC address which must be assigned prior to installation of the device.The address is set using either the handheld device programmer or the device addressing feature built into each Potter fire alarm control panel. Pull Station Front View �� � 0 I pa. 0 AL, rliFillmm.. r '7101151111111111.111ALFdli-A---11111.d ig& L________Nih..4 --.P U - --........................_ .._ 1 .4041 e APS-DA APS-SA Pull Station Back View and Wiring o 0 C-D 0 C 54S- M,S L4,,,,,,_ FROM FACP OR PREVIOUS DEVICE TO NEXT DEVICE dollop I FACTORY WIRED CONTACTS 0 01 Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 180 9001,2008DESIGNING,MANUFACTURING, CERTIFIED I&DISTRIBUTING QUALITY SYSTEMS 8830052-REV B • 10/14 PAGE 2 OF 2 (4 °F I/4 P POTTERi / MT The Symbol of Protection Single Co , oj 055 Features Vail Fire&Emergency Services 09/22/16 • One Class B(Style B)contact monitoring input • Powered directly from 2 wire SLC Loop 41110 • SLC Class A(Style 6,7)&Class B(Style4) • Mounts on a standard 4"or double gang box • 1 I • • Wiring terminals accessible when mounted in box � 1 s- s' • Wiring terminals accept 22 to 14 AWG s • • Product includes a 5 year warranty NOTE:This addressable module does not support 2-wire smoke ©NO Q detectors. O � , ' I • Stock Number: 1430821 C ® US LISTED I I S2930 7165-0328:0196 Application Technical Specifications The SCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.0V 8500 addressable fire alarm control panels. The SCM-4 is a contact Max SLC Standby Current 325µA monitor module used to supervise a circuit of dry contact input devices Max SLC Alarm Current 1mA such as; sprinkler water flow,valve tamper switches or conventional pull stations. Max Wiring Resistance of IDC 10052 Max WiringCapcitance of IDC 1µF EOL Resistor 5.11(12 Description Max no.of SCI on SLC loop in The SCM-4 module uses one(1)address on an SLC loop.The module Class A 64 Units is used to supervise a Class B circuit of normally open, dry contact Operating Tempurature Range 32 to 120°F(0 to 49°C) input devices.The SCM-4 module includes one red LED to indicate the modules status. In normal condition,the LED flashes when the Operating Humidity Range 0 to 93%(non-condensing) device is being polled by the control panel.When a device is activated, Max no.of Modules per Loop 127 units the LED will light continuously.In case of an open circuit,the LED 4.17"(106mm)L x 4.17" will turn off. Dimensions (106mm)W x 1.14"(29mm) Mounting Options Standard 4"Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830006-REV D • 7/14 PAGE 1 OF 2 P POTfER.iVMi ec . IMF ® The Symbol of Protection Single C. cj � # -N Setting the Address Vail Fire e&Emergency Services 09Each SLC device must be assigned an address prior to installation.The address is set using either the hand held device programmer or the addressing feature on the PFC-6000/PFC-8500 Series control panels. Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box CO ° • Ci) , :::, 0 . .joi, O c `% o i t a 4 .1P1hPPlifjP 1 o 0 Wiring Diagram Note:The resistance of external wiring shall be less than 1000. The capacitance of external wiring shall be less than 1 micro farads. /5.1Kf11/2W EOLR COM ✓/ To Next Module 5' NO 5- z SLC Loop ED Single Contact Module From FACP or Previous Module Model No.SCM-4 J DWG#593-14 Potter Electric Signal Company, LLC • St. Louis,MO • Tech Support: 866-956-0988 /Customer Service: 866-572-3005 • www.pottersignal.com ISO 9001:2008 DESIGNING,MANUFACTURING, CERTIFIED i&DISTRIBUTING QUALITY SYSTEMS 8830006-REV D • 7/14 PAGE 2 OF 2 .."tee PPOTTERi / MT .4i_. ,... ,....,c The Symbol of Protection ..."Dual Co „. Features Vail Fire&Emergency Services 09/22116 ,. • Single module with dual contact monitoring inputs ' , • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) T - • Mounts in a standard 4”or double gang box • ' -- • Wiring terminals accessible when mounted in box itI�� ►e- w+°-..,' • o ,..Mode, • All wiring terminals accept 22 to 14 AWG 9 im e • Product includes a 5 year warranty > NOTE: This addressable module does not support 2-wire smoke m®EIm detectors. ' ,._.. ',RJ.•.F;'. •.fid. •.F-.? -.F,.' 1 0 • 1111 Stock Number: 1430822 CCOUS LISTED . I S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.0V 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325µA module used to monitor dry contact devices such as sprinkler water Aux Power Required lmA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC 100 S2 Max Wiring Cpacitance of IDC 1µF EOL Resistor 5.1K 12 Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring 127 units(Class A)or 63 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class B) square or double gang box.The module is capable of monitoring two — (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L x 4.17" waterflow and valve tamper switches when they are located in the same (106mm)W x 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is being Mounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 lbs light continuously and in case of an open circuit,the LED will turn off. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830008-REV B • 7/14 PAGE 1 OF 2 olti OF pi ...."Iik. POTTER° OHM/ The Symbol of Protection Dual Co ,,. 1goJ% Setting the Address Vail ire&Emergency Services Each addressable module, smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box /CD 0 co, 0 o ® o � dii I. 07 �� *<- t CO 10 0 0 40 \ o ° / Wiring Diagrams DCM-4 With One ClassA Circuit NOI I!uiiiuiiiu TO THE NEXT MODULE JPI C2 ,r4 if 0000 LED 0 Z2 SELECT STYLED 0000 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM-4WithTwoClassB Circuits N 0 I/1 jrningni FROM FACP OR C1 ac PREVIOUS MODULE �i S+ Z1 5i END-OF-LINE RESISTOR 5.1K OHM 1/2W aNO2 GE L S ac TO THE NEXT MODULE — JPl C2 ol: l�\H�H\€� SELECT STYLE B •00000 LED Q Z2 EEL END-OF-LINE RESISTOR 5.1K OHM 1/2W Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 180 9001:2008 DESIGNING,MANUFACTURING, CERTIFIED I&DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 dodti OF go SYSTEM SENSOR° ' IgoJF ergency Services Selectable Output fr $, j j • ' Notification Devices I 1 ' .� 4 SpectrAlert'Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECT rt A N C The SpectrAlert Advance series of notification appliances is Features designed to simplify your installations,with features such as:plug in ,plug in design designs,instant feedback messages to ensure correct installation of individual devices,and eleven field-selectable candela settings for •Same mounting plate for wall-and ceiling-mount units wall and ceiling strobes and horn/strobes. •Shorting spring on mounting plate for continuity check before installation More specifically,when installing Advance products,first attach a universal mounting plate to a four-inch square,four-inch octagon or •Captive mounting screw double-gang junction box.The two-wire mounting plate attaches to •Tamper resistance capability a single gang junction box. •Field selectable candela settings on wall and ceiling units:15,15/75, Then,connect the notification appliance circuit wiring to the SEMS 30,75,95,1 10,115,135,150,177,185 terminals on the mounting plate. •Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela Finally,attach the horn,strobe or horn/strobe to the mounting plate Outdoor wall and ceiling products by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position,locking the product's pins into the •Outdoor products rated from—40°to 151°F mounting plate's terminals.The device will temporarily hold in place •Minimal intrusion into the back box with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: •Horn rated at 88+dbA at 16 volts •12 or 24 volts •Rotary switch for tone selection •At 24 volts,15,15/75,30,75,95,110,115,135,150,177 or 185 .3 horn volume settings candela by way of rear-mounted slide switch and front viewing window •Electrically compatible with existing SpectrAlert products •Horn tones and volume by way of rotary switch The SpectrAlert Advance series includes outdoor notification Agency Listings appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for SIGNALING ,� 7125-1653186(indoor strobes)only.All System Sensor outdoor products are rated between 0MEA 7125-1653187(outdoor strobes) Y;;. 7125-1653.188(horn/strobes) minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or approved --1 7125-1653.189(horns) LISTED APPROVED I I dry applications. nnen452-05-E ."1,,,e SpectrAlert Advance Specifications Architect/Engineer Specifications • 6 General iCID] SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box or double-gan. - Two-wire products shall also mount to a single-gang 2 x 4 x 1k-inch back box.A universal mounting plate shall be used for mounting ceilingpp lg?1E ncy Services The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with 0*-Circuit" Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30,75,95,110,115, 135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 41X6 x 4'Xe x 2A-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature —40°F to 151°F(-40°C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.6"L x 4.7'W x 2.5'D(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7'W x 1.3'"D(142 mm L x 119 mm Wx33 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12V nominal only for 15 and 15/75 cd. A05-0395-002 ..1/4.4..,„. tra,.,,,, ill UL Current Draw Data oAL UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 1.4‘,....300311.w. Candela DC FWR DC FWR Sound Pattern dB DC FWR DC Standard 15 123 128 66 71 Temporal High 57 55 ilFire&�nergencyServices Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58f 2y16 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Horn Tones and Sound Output Data Rotary Horn and Horn/Strobe Switch Settings Horn and Horn/Strobe Output(dBA) Setting Repetition Rate dB Level Switch 8-17.5 Volts 16-33 Volts 1 Temporal horn High Position Sound Pattern dB DC FWR DC FWR 2 Temporal horn Medium 1 Temporal High 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 Non-temporal High 82 82 88 88 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 7* Externally coded High 6 Non-temporal Low 75 75 81 81 8* Externally coded Medium 7* Coded High 82 82 88 88 9* Externally coded Low 8* Coded Medium 78 78 85 85 9* Coded Low 75 75 81 81 *Settings 7,8,and 9 are not available on 2-wire horn/strobe. A05-0395-002 olti OF go ilkil a ..1.6 SpectrAlert Advance Dimensions -4.7" ■ -"n-!!1, t;:fr);x" 6.8Digo7 .e5"-._ / Vail Fire&Emergency Services / KO\ NOW SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn/Strobes Ceiling Horn/Strobes(cont'd.) P2R*t 2-wire Horn/Strobe,Standard cd*,Red PC2W*t 2-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC2WH*t 2-wire Horn/Strobe,High cd,White P2RK* 2-wire Horn/Strobe,Standard cd,Red,Outdoor PC4R 4-wire Horn/Strobe,Standard cd,Red P2RHK* 2-wire Horn/Strobe,High cd,Red,Outdoor PC4RH 4-wire Horn/Strobe,High cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor P2WH* 2-wire Horn/Strobe,High cd,White PC4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor P4R" 4-wire Horn/Strobe,Standard cd,Red PC4W 4-wire Horn/Strobe,Standard cd,White P4RH* 4-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P4W* 4-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red P4WH* 4-wire Horn/Strobe,High cd,White SCRK Strobe,Standard cd,Red,Outdoor Wall Strobes SCRHK Strobe,High cd,Red,Outdoor SR*t Strobe,Standard cd,Red SCW*t Strobe,Standard cd,White SRN** Strobe,High cd,Red SCWH*t Strobe,High cd,White SRK Strobe,Standard cd,Red,Outdoor Horns SRHK Strobe,High cd,Red,Outdoor HR Horn,Red SW* Strobe,Standard cd,White HRK Horn,Red,Outdoor SWH" Strobe,High cd,White HW Horn,White Ceiling Horn/Strobes Accessories PC2R* 2-wire Horn/Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red PC2RH* 2-wire Horn/Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White PC2RK 2-wire Horn/Strobe,Standard cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red PC2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor BBSCW-2 Back Box Skirt,Ceiling,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP t"High cd:'refers to strobes that include 135,150,177,and 185 candela settings."Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. *1 SYSTEM 02006 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without no&e.Usit systemsensotcom for �V SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0395-002.7/06•#1659 4-. + V /�LER � / / / ��p � � /s0/V/� Is PS-1270 12 Volt 7.0 AH 0 # S 0 iino Rechargeable Sealed Lead Acid Battery We ve Vail Fire&Em=.-O5^yf "" 09/22/16 Features • Absorbent Glass Mat (AGM) technology for superior performance • Valve regulated, spill proof construction allows safe sealed Rechargeable Battery operation in any position POOFRAI //O�rOA/iii! • Power/volume ratio yielding unrivaled energy density MODS t Pos, NO" , P°-°°'"m • Rugged impact resistant ABS case and cover (UL94-HB) Po • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified " • U.L. recognized under file number MH 20845 Terminals (mm) Performance Specifications • F1-Quick disconnect Nominal Voltage 12 volts(6 cells) tabs,0.187"x 0.032"- Mate with AMP. INC. Fl F2 Nominal Capacity FASTON "187"series I-32- )-3A-j 20-hr. (350mA to 10.50 volts) 7.00 AH -OR- II4.75 II6.35 10-hr. (650mA to 10.50 volts) 6.50 AH • F2-Quick disconnect tabs,0.250"x 0.032" I-6.3s-I=o.8 ~795H=o.6 5-hr. (1.2A to 10.20 volts) 6.00 AH -Mate with AMP. INC 1-hr. (4.5A to 9.00 volts) 4.50 AH FASTON "250"series 15-min. (14A to 9.00 volts) 3.50 AH Physical Dimensions: in(mm) Approximate Weight 4.80 lbs.(2.18 kg) Energy Density(20-hr.rate) 1.49 W-h/in3(90.95 W-h/l) ISpecific Energy(20-hr.rate) 17.50 W-h/lb(38.58 W-h/kg) ® W Internal Resistance(approx.) 23 milliohms Max Discharge Current(7 Min.) 21.0 amperes Max Short-Duration Discharge Current(10 Sec.) 70.0 amperes Shelf Life(%of nominal capacity at 68°F(20°C)) 4 s- 1 Month 97% POWER ,SON/( HT H 3 Months 91% MODEL PS-12:. 70 F1 6 Months 83% :::: 1 Operating Temperature Range L I Charge -4°F(-20°C)to 122°F(50°C) Discharge -40°F (-40°C)to 140°F(60°C) L:5.95(151) W:2.56(65) H:3.70(94) HT:3.86(98) Case ABS Plastic Tolerances are+/-0.04 in.(+1-1mm)and+/-0.08 in.(+/-2mm)for Power-Sonic Chargers PSC-12800A, 12800A-C height dimensions.All data subject to change without notice. To ensure safe and efficient operation always refer to the latest edition of our Technical Manual,as published on our website. O Wer-S0111C.COi11 All data subject to change without notice. ry�y�y,p OF /POWER���////50)V/l PS-1271 z 4/ '1 H Z. Shelf Life &Storage Discharge Character ip • 100 Cha ging is not 14.0 I I 1 1 I I I I o l necessary unless Ambient Temperature 20 C(6: 0j, Si 131 O 100%of capacity 13.0 IIELIWiledigl 'NM IP is required. _ce 80 Cha ging before > -- O.ervices G (41°F) _ use is necessary y 12.0 __ _ ,1, �' (41°F) to help recover as 111111111419.1411k211' .1 c full capacity. vs a; 60 ` . 0 11.0 1111WhM11..11101.7a, Chargemayfail To C .. �� � torestorefullw 40°C 30°C 20°C capacity.Do not = 10.0 ' 0 0.35 v 40 104°F (86°F) (68°F) let battedesreach E / 1.4 co ( ) this state. 9.0 • ••pp '3.5 `a° 0? I Final U 0 2 4 6 8 10 12 14 16 18 20 Voltage ,7.0 Standing Period (Months) 8.0 14 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 Discharge Time vs. Discharge Current 1. min ►I'h -�I T Discharge Time 20 - 15 \ 10 \ Life Characteristics in Stand-By Use L AmbientTemperature 20°C(68°F) as 5 Final I 0 100 E Voltage y 02 10.5V \\ •_ 80 --.....ssmimineinum En 10.2V \ Ce m 60 y 1 \\ 0 40 Float Charging Voltage 6 9.6v \\ - 2.25-2.30 V/Cell 30 \ as 20 m c \ Ce 0• 9.0V 0 1 2 3 4 10 \ \40°C(104°F) 20°C (68°F) Years 0°C (32°F) 5 8.1V Life Characteristics in Cyclic Use 0.35 0.70 1.4 3.5 7.0 14 120 Discharge Current(A) 100 y Charging ;, 80 Cycle Applications:Limit initial current to 2.1A.Charge until battery voltage es (under charge)reaches 14.4 to 14.7 volts at 68°F(20°C).Hold at 14.4 to 14.7 m 60 Discharge Discharge Discharge volts until current drops to under 70mA.Battery is fully charged under these Depth 100% Depth 50°! Depth 30% conditions,and charger should be disconnected or switched to"float"voltage. 0 40 y 1.Discharge Current 0.2C(Final Voltage 1.7V/Cell) "Float"or"Stand-By"Service:Hold battery across constant voltage source of y 20 2.Charge Current;0.1C I I I 13.5 to 13.8 volts continuously.When held at this voltage,the battery will seek its cG 3.Ambient Temperature:20°C to 25°C(68°F to 77°F) own current level and maintain itself in a fully charged condition. 0 0 200 400 600 800 1000 1200 Note:Due to the self-discharge characteristics of this type of battery,it is Number of Cycles imperative that they be charged within 6 months of storage,otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for"C-Series downloads,such as product catalogs,material safety data sheets(MSDS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Technical department for advice if you have difficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1-619-661-3648 Fax:+1-650-366-3662 national-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com battery@power-sonic.com CORPORATE OFFICE • 7550 Panasonic Way• San Diego,CA 92154 • USA •Tel:+1-619-661-2020 • Fax:+1-619-661-3650 0308 1M 40 OF pi. Hon IPGSM-4G ,)3Q #ktk IP Internet & GSM Vail Fire&Emergency Services (4G/3G/2G) Dual Path Communicator 09/22/16 General � �m .,F,�m, • The IPGSM-4G is a 4G fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel (FACP) "°m"' that has a built-in dialer.This easy to install, dual path commu- nicator connects directly to the primary and secondary corn- munication ports of a Fire panel's Digital Alarm Communicator Transmitter (DACT). It offers three selectable reporting paths which include: (Cellular only), (IP only), or(IP primary/cellular backup). In the event of an off-normal condition,the fire panel sends contact ID formatted information to the IPGSM-4G com- municator panel. The IPGSM-4G then reformats the data into highly encrypted Ethernet packets for transmission to the Alarm-Net receiver via customer-provided Internet/Intranet connection or the GSM network. • Reliable connection: IP and GSM connection tested every Alternative communication methods are critical in the market- day. place due to VoIP (Voice over IP), migration from POTS(Plain • QOS: Quality of Service diagnostics via AlarmNet conveys Old Telephone Service) and growth of digital radio networks. vital communicator information including when message The IPGSM-4G's exclusive dual-path communications solution was received,signal strength,and message path used. combines Internet service with GSM for added reliability and • 7720P Hand-held programmer for easy setup. an extra level of security. All signals from the IPGSM-4G com- municator panel are delivered to Honeywell's AlarmNet Net- work Control Center, which routes the information to the Operation appropriate central station. The state of the art AlarmNet net- When an event occurs, the Fire Alarm Control Panel goes off work control center is fully redundant and monitored 24/7. hook to dial the central station.The IPGSM-4G Dialer Capture AlarmNet has the ability to route messages using AlarmNet-i Module detects the off-hook condition and provides the fire and 800 PLUS services, providing true redundancy and multi- panel with a dial tone. When the fire panel detects the dial path message delivery. tone, it begins dialing the central station. After the dialing is The IPGSM-4G is designed to operate over the most common completed,the Dialer Capture Module returns a handshake to GSM networks including 2G,3G and 4G. Its multi-GSM plat- the fire panel.The fire panel then sends the contact ID reports form technology automatically chooses the best available cel- to the Dialer Capture Module, which in turn sends a kiss-off lular signal in the area based on signal strength and after the report is successfully received from the fire panel. seamlessly self-adjusts to maintain critical life safety communi- The Dialer Capture Module sends the contact ID reports to the cation. IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- Features tions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent • Saves the cost of two dedicated phone lines. on configuration). • Dual path communications. Can communicate to central station using Internet or cellular technology. Easy to Program • Requires no change to the existing Fire Alarm Control The IPGSM-4G communicator can be pre-programmed using Panel configuration. The IPGSM-4G connects directly to the 7720P programmer to enter all central-station information. the primary and secondary telephone ports. This is saved to the IPGSM-4G communicator panel memory. • Multi-GSM platform compatibility for 2G,3G and 4G. When the IPGSM-4G communicator is installed at the site and • Operates over the following communication protocols: connected to the Internet/Intranet, it registers itself with the HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) AlarmNet receiver. GPRS(2G). .For most installations,the only required parameters are: • Works over any type of customer provided Ethernet 10/100 • Primary City ID (two digits) obtained from your monitoring • Base network connection (LAN or WAN), DSL modem or station. cable modem. • Primary Central Station ID (two digits) obtained from your • Data transmits over standard contact-ID protocol but is monitoring station. secured with the industry's advanced encryption standard • Primary Subscriber ID(four digits)obtained from your mon- (AES 256 bit). itoring station. • Supports both dynamic(DHCP)or Public and Private Static • Communication Module's MAC ID, and MAC CRC number IP addressing. located on outside of box,and inside of the module. • Built-In Power Supply module: On board charging circuit All of these parameters are assigned by the monitoring station. design accommodates back-up battery. Includes primary power and battery supervision. NOTE: Some assembly is required. See Installation and Setup • Diagnostic LEDs: Signal strength and status indicators. Guide#800-12454 for full details. 101 OF gr, Nr14111111111111141. 14: 0( Panel Capabilities Cabinet Specifications The IPGSM-4G is compatible with fire panels that use the Dimensions: 14.875"H x 12.75"W x 3.0" D ir Contact ID communications format as described in the SIA cm W x 7.6 cm D). DC-05 standard. Color: Red. 0, � #�, AlarmNet Shipping Specifications Vail Fire&Emergency Services Honeywell's AlarmNet has been the nationwide leader in Weight: 5.3 lbs. (6.94 kg). 09/22/16 alarm communications technology since 1986.A reliable alter- Dimensions: 15.625" H x 13.79" W x 9.25" D (39.7 cm H x native for the transmission of alarm signals, our radio network 34.9 cm W x 23.9 cm D) provides extensive coverage in the United States and Canada. AlarmNet Network Control center processes signals from pow- erful servers in multiple locations equipped with 24/7 infra— structure support.The AlarmNet network consist of redundant This system meets NFPA requirements for operation at 0 - hardware servers, hot back-up databases and generators with 49°C/32- 120°F and at a relative humidity 93%±2% RH (non battery back-up at all locations to ensure continuity of service. condensing at 32°C ± 2°C (90°F ± 3°F). However, the useful Signals from Alarm-Net are transmitted to the central station's life of the system's standby batteries and the electronic com- receivers using multiple communications paths consisting of ponents may be adversely affected by extreme temperature the Internet, radio network or toll-free POTS service. ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with Installation Requirements a normal room temperature of 15-27°C/60-80°F. UL COMPLIANCE Product Line Information To meet UL864/NFPA,ensure the following: IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- • IPGSM-4G must be installed in accordance with NFPA cator Panel. Includes red cabinet with ademco key and lock, (National Fire Protection Association)standards 70 and 72. wall outlet box, Dialer Capture Module, iGSM Communications • IPGSM-4G must be mounted in the same room and within Module, antenna & mounting adapter, PowerBoostl power 20 feet of the fire panel. supply, LED display board, transformer, manual, & required • IPGSM-4G, and all equipment used for the IP connection screws,cables, etc. (such as the router, hub, modem, etc.) shall be listed, must GSM-ANT3DB: 3db gain external/remote antenna. be powered from an un-switched branch circuit,and be pro- 7626-50HC:50 ft.antenna cable, low loss. vided with appropriate standby power. 7626-25HC:25 ft.antenna cable, low loss. • IPGSM-4G must use the 7AH battery(not supplied)to pro- WA7626-CA: SNA to N Adapter. vide 24-hour backup capability. 7720P: IPGSM-4G hand held programmer. HPTCOVER: Plug in transformer box for IPGSM communicator. Electrical Specifications BAT 1270: Battery 12 Volts,7 AH,sealed. Transformer: —Primary 120VAC,60Hz,0.5A. Agency Listings and Approvals —Secondary: 18VDC,50VA. The listings and approvals below apply to the basic IPGSM-4G Battery: communicator panel. In some cases,certain modules may not be —One 12 V 7.0 AH lead acid battery(not supplied). listed by certain approval agencies,or listing may be in process. —Battery charging current: 1 Amp maximum. Consult factory for latest listing status. —Battery discharge current: Standby 230mA, Active UL Listed: S789. 950mA. CSFM:7300-1645:0199. FDNY: COA#6150. This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. 02013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877)HPP-POWR Northford, CT 06472-1610 hpp_techsery@honeywell.com www.honeywellpower.com DH-60769:B June 2013 Madein the U.S.A. I® U.S.Sr®U.SRegistered Trademark ©2013 Honeywell International Inc. ENGINEERING B MANRFACTRRINC Page2of2 QUALITY SYSTEMS