HomeMy WebLinkAboutA16-0059_cut sheets_26_1478896837.pdf 40OF ...4,0"Pe. 16 we 47, � c FII ..•i Q DATA lib. Is ' Vail Fire&Emergency Services CYBERCAT® 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM 10/13/16 DESCRIPTION ' Fike's CyberCat 254(P/N 10-066)is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.It is ideal for all life safety and property protection applications and is intended for both commercial and industrial use. It is designed with extensive programmability that allows the almost-instantaneous relay of information and the ability to perform process management tasks with ease including HVAC shutdowns,Emergency Voice Evacuation,damper control,doors closure,elevator recall, security,and CCTV/Building Management Awareness. This cost-effective panel comes standard with one Signaling Line Circuit(SLC)that supports 254 devices,with any mix and match of sensors and modules.The CyberCat utilizes extreme intelligence via its eclipse based sensors including photoelectric,photoelectric with heat,ionization,photoelectric duct,and heat detectors. It also utilizes Eclipse''based modules such as the monitor,mini-monitor,relay,intelligent pull station and control modules.With CyberCat,every device communicates as a peer on the signaling line circuit.These peers not only communicate up-to-the-second information to the control panel,but also communicate with each other.Each device is capable of generating accurate and highly detailed information.Conventional fire alarm systems give a general idea of the fire's location,while the CyberCat's intelligent sensors indicate precisely which device is in an alarm state.This intelligence provides incredible speed with response times as little as one-quarter second between manual pull station and notification appliance.Its flexibility allows you to attach the intelligent devices that are required for your specific application. Fike CyberCat 254 The System is programmed with either the Windows based field configuration software C-LINX"or through a comprehensive password protected front-panel keypad programming options.This option allows you to quickly update and adapt to any future requirements or changes in the system such as changes in occupancy APPROVALS: or remodeling.The sophisticated control panel circuitry coupled with the software allows you to read specific information and sensitivity levels of the different Eclipse devices.The sensors also compensate for • UL-S2203 any changes due to age,contamination,or other environmental factors. • FM-3020297 • City of Denver SYSTEM OPERATION • City of Chicago • CSFM-7165-0900:0137 The CyberCat Control system operates on a"Zone and State"relationship, In this design,all input and • MEA-490-04-E output devices must be assigned to at least one zone or to all zones(254 are available),each one defining an area to be protected.Input devices can be assigned up to four zones(one zone is typical)and output devices may be assigned up to 254 zones. These devices use the SLC signaling line circuits to exchange status information with other devices as well 4:* 0 as with the control panel.When an input is activated,it is configured to cause its associated zone to enter •r,an• into an operational state.Any detection device will cause its associated zone to enter into an alarm state. The output devices are configured to activate to protect and evaluate the endangered zone.This system is completely modular,allowing you the flexibility to design a system that is lust right for your application.A —,-,7 typical configuration is shown on page 2 that illustrates the communications of a CyberCat system. a I 1 I1 , . . ;.1 ,. • • ' Form No.D.1.09,01-7 704 SW 10th Street • P.O.Box 610 • Blue Springs,Missouri 64013-0610 U,S,A. Phone:816.229.3405 • www.fike.com or."140. 44'1015 .14 TYPICAL CONFIGURATION •jlka ' FULL INTEGRATION := � � AlE SAMPLING I • Vail Fire&Emergency Services 10/13/16 • ® s....r , CONTROL FUNCTION VESDA0 LacerPluc ' OFF PREM1SES ".••••'• • ur peleiivSrokdr rre•I;ctten Comm un innti nn F-0:47 °6yr ro tut Consrvl Module in Conlsol Stel,nn and Nelw irk r.nmm.rI,C2 1tinn CVberCat Fire Alarm Panel to otter Penal%f C Pmipheral Devicrs GENERAL BUILDING FIRE ALARM LINEAR I IEAT DETECTION CABLE — — — Photo ran mete Coot sltt.uiyelnt Deflect et FICA l Pult$tatipn pleo• Strobe NAC Module Relay Module End of Line Boa Oil Module •'urrs on and opal,lea Performs Pr oc•s•Managnment Teske: strobes,ho'n,,bets •Shutdowns •Voite Fvetudlbn Systeme, •Moms for mulItle •ENAC •SnorrilpCCTV'Butdirp Patriot tor arrow l 'ticvrcmr M,i,U0111011 AWiRe1104e nur.nl or.rwdon •floors.Dampers STANDARD FEATURES The Cybercat features are designed to save lives and protect your valuable capital investments through unprecedented speed,intelligence and flexibility.These features include: • All Cybercat panels come standard with a controller,transformer and enclosure(see ordering information for details) • 254 user defined zones • 80 character,backlit LCD display • Real time clock • 3200 event history buffer • Critical process monitoring • One-person walktest capability • Disable by circuit or zone • Drill function at panel and remote • Provides solenoid releasing operation • Alarm verification capability • Easy to add/remove devices • Diagnostic menus • Removable terminal blocks for field wiring • Local piezo with distinct event tones • 10 Status LEDs to easily identify system status • Optional point ID DACT Module available • Supports up to 31 peripheral devices such as Remote Display,LED Graphic and Zone Annunciators • Two standard enclosures sizes available with optional deadfront panel options(refer to data sheet D.1.26.01) 2of6 101 OF iv. 4,440 CYBERCAT 254 CONTROLLER SPECIFICATIONS, The controller contains the power supply,microprocessor,hardware interface,display and keypad. 11, Enclosure —..-1,1)100W4 • Steel Enclosure 23.6"H x 14.35"W x 4"D(Back-box dimensions) • Flush or surface mounting Vail Fire&Emergency Services • Removable door for ease of installation 10/13/16 • Available in red or black • Dead Front option available to isolate panel's internal electronics and wiring Power • 6 amps useable alarm power • Operation from 120VAC/60 Hz or 240 VAC/50 Hz transformer • Two 24V DC,2A continuous auxiliary power outputs • One 24VDC,2A resettable auxiliary power output • Supports up to 75AH of batteries • Controller consumes 0.275A @ 24 VDC in normal standby and alarm Signaling Line Circuit • Address devices with Infrared(IR)tool,similar to remote control device • One SLC loop,NFPA style 4,6 or 7 • 254 devices • True peer-to-peer digital protocol for extremely fast and reliable communications • Auto address function • Automatic day/night sensitivity adjustment • Automatic holiday sensitivity adjustment • Acclimate operation for sensors • IR Tool provides ability to read sensitivity levels or perform remote test of device • Devices contain multi-color LED for quick reference of device status • Sensors provide early warning pre-alarm detection and can also provide a summing feature(up to eight sensors) • Maximum Resistance:70 ohms • Maximum Capacitance:.60µf • 12,000 ft.maximum distance total from panel to last device NAC Circuit • Two NAC circuits standard • Rated at 24VDC,2.0 Amps maximum • Built-in synch protocol for System Sensor®and Gentex®devices Operating Environment • 32-120°F(0-49°C) • 93%relative humidity,non-condensing OPTIONAL MODULES AND PERIPHERAL DEVICES Point ID Dact(Digital Alarm Communicator Transmitter)Module(P/N 10-2528)* The DACT provides interface with Central Station monitoring systems.It is available with 5 contact zones of connection OR the intelligent serial interface which provides point ID Information.The Contact ID form is the preferred reporting format.It provides a four digit account code followed by a three digit event code,a two-digit group number,and a three digit contact number,all of which are used to provide specific point identification.This DACT can also provide an SIA or 4/2 Pulse reporting format.Note:10-2476 is same as 10-2528 with enclosure for external mounting. Fike Relay Module(P/N 10-2204)* The CRM4 provides 4 additional independently programmed relays.CyberCat Control Panel supports up to 2 CRM4 modules(if either options are not unused)on the main controller board.Each relay may be wired across normally open or normally closed contacts. Dimensions:3-1/2"L x 1-1/2"H x 2"D.Weight:0.10 lbs. Fike Reverse Polarity Module(CRPM)(P/N 10-2254)* The reverse polarity module provides the ability for UL Remote Station supervision.This supervision is typically performed with a direct, leased line connection.It interfaces to the main control board using four standoffs supplied with the RPM.Dimensions:3-1/2"L x 1-1/2" H x 2"D.Weight:0.08 lbs. 14 Button Remote Display Unit(P/N 10-2646)* The Fike fourteen button remote display(FRD),provides remote annunciation of Fike's intelligent control panels.The FRD is provided with a 80 character,backlit display which performs two display functions.First,it duplicates information provided by the control panel. Additionally the FRD has the capability of viewing system conditions such as alarm,trouble,supervisory,etc.The FRD also includes six buttons(Enter,Escape,+/-,left/right arrow)that are used for navigation through events as well as configuration of the device. Additionally it has eight programmable buttons that can be configured for things such as reset,silence,acknowledge,drill,or process.A key lock is included for additional security access. 10 Button Remote Display Unit(P/N 10-2631)* The Fike ten button remote display(FRD),provides remote annunciation of Fike's intelligent control panels.The FRD is provided with a 80 character,backlit display which performs two display functions.First,it duplicates information provided by the control panel.Additionally the FRD has the capability of viewing system conditions such as alarm,trouble,supervisory,etc.The FRD also includes six buttons(Enter, Escape,+/-,left/right arrow)that are used for navigation through events as well as configuration of the device.Additionally it has four dedicated buttons that perform the following functions:drill,silence,acknowledge,and reset.A key lock is included for additional security access. *See ordering information for individual data sheet that gives additional specifications 3 of 6 14, OF iv. 2 Button Remote Display Unit(P/N 10-2630)* 10-1 The Fike two button remote display(FRD),provides remote annunciation of Fike's intelligent control panels.The FRD is provi. itt 80 character,backlit display which performs two display functions.First,it duplicates information provided on the main contro #1i Additionally,the FRD has the capability of viewing system conditions such as alarm,trouble,supervisory,etc. QQ Fike Zone Annunciator(P/N 10-2667)* Vail Fire&Emergency Services The Fike twenty zone remote annunciator is used with Fike's intelligent control systems to provide remote annunciation for ua@f3 41fnty zones at a location remote from the control panel.The module provides a tabular display that Incorporates 20 red alarm and 20 yellow trouble/supervisory LEDs.Each LED is programmable and can provide visual indication of alarm,trouble/supervisory conditions for zones or individual points.Communication between the intelligent control panels and remote annunciator is via the RS485 peripheral bus.When an event from the control panel is received the appropriate LED will illuminate based on the annunciator's configuration. Fike Network Module(P/N 10-2482)* The Network Module provides the ability to network up to 128 control panels.This typically would consist of other CyberCat fire alarm panels.The CyberCat network uses a"common zone"functionality.Zones 1-254 are common to all panels on the network and any input will cause activation of all outputs for the same zone,regardless of which panel the devices are connected to.Regardless of zone number, every state(alarm,trouble etc.)that occurs is displayed by all panels on the network. Fike Fiber Optic Network Card(P/N 10-2624)* The Network Module(P/N 10-2624)provides the ability to network up to 128 control panels.This network would typically consist of other CyberCat or Cheetah Xi fire control panels.The network uses a"common zone"functionality.Zones 1-254 are common to all panels on the network and any input will cause activation of all outputs for the same zone,regardless of which panel the devices are connected to (except abort and predischarge on Cheetah Xi).Regardless of zone number,every state(alarm,trouble etc.)that occurs can be displayed by all panels on the network. Fike Ethernet Module(P/N 10-2627)* This Module provides the ability to remote monitoring of multiple CyberCat panels via Ethernet/IP.This module is connected to the CyberCat via the peripheral connections at P6 and will be configured as a peripheral device.In order to utilize the remote monitoring capability,a network ID must be assigned to each panel for identification purposes.This module connects to the Panel at P6 per±and also requires 24 volts DC from the panel to P6 24A±.See the 06-388 Ethernet Module manual for more details. Fike Multi-Interface(P/N 10-2583)* The primary function of the multi-interface module is that it is used as a printer interface for the CyberCat control panels.It provides specific event and point information to be communicated from the panel to the printer.It Is compatible with either a Epson FX-890 or equivalent IEEE 1284 standard printer or for UL required applications the Keltron 90 series UL listed fire alarm printer. PROGRAMMING CONFIGURATION Software All configuration variables can be assigned using C-LINXsoftware.This software provides the designer the capability to provide a pre-engineered design.The user can review the construction plans to assign the zones.The configuration can also be set to identify the exact device circuit operation desired along with the custom message information. IR Configuration Tool(P/N 55-051)* This optional hand-held infrared remote control is available on the CyberCat system.This small device can be used in the field to simplify installation,testing and service.It operates with 2 AA batteries and can read device information such as loop,address,branch and service dates and initiate device test.This tool: • Communicates bi-directionally with any CyberCat device • Easily addresses devices by setting the loop and address • Quickly reads sensitivity levels,date serviced,device type,loop and address,manufacture date • Immediately records the date serviced • Instantly initiates walk test of any sensor or module • Accesses and tests hard-to-reach sensor or module(such as duct detector)through any other device on loop *See ordering information for individual data sheet that gives additional specifications 4 of 6 olti OF go ..,"4/e. Z.... 41ittr IA PR FIELD WIRING DIAGRAM COMMUNICATION TO REMOTE PANELS 'NOT RS BS OR PEER-TO-PEER NETWORK TO LOCATED OFF PREMISIS F�• r REMOTE FACP(128 NODES MAX) ■ Vail Fire&Emergency Services TELCO LINESy 4101) 10/13/16 INTERNAL r EXTERNALL f TELCO LINES `4B5 DACT - � RS455 PERIPHERAL REMOTEi- "ZONE _ LED SMOKE I ETHERNET MULTI- 2 PAIR =US(3 X, DISPLAYS-ANNUNCIATOR GRAPHIC CONTROL`� MODULE INTERFACE - GRAPHIC LL REVERSE POLARITY TO UL REMOTE STATION 24V-DC AUX POWER (RESETTABLE) _ VESDA R,5465 RS232 24V-DC AUX POWER r y DETECTOR HLI (CONTINUOUS) MASTERBOXgh I-I SYSTEM ON-BOARD RELAYS PRINTER (ALM,TRB,SUPV) MASTERBOX UP TO 253 OMM SUPERVISOR Il PROGRAMMABLE MM MODULE ZONES APS UM IAMBI SCM KM 10A874(•.A(31.E F DEVICES MAX,) �- F� ,•a. o 0 B COMPATIBLE DETECTORS SCM IDC NAC/ CONTROL LAPTOP PC SOLENOID 7 " INTEGRATED SWITCHMODLILES; -77":-cd84-i0: 0El "r" W• • 6-ZONE SMOKE CONTROL gy.Yy '- y;r COMPATIBLE • 20-ZONE I/O CONTROLr"-:1,+ SUPERVISED NAC CIRCUIT SI CONVENTIONAL • 20-ZONE ANNUNCIATOR ±_"�: g: DETECTORS V Q12VDEDICATED20140AC • Ei POWER INPUT CYBERCAT SUPERVISED NAC CIRCUIT#2 254 EXTERNAL BATTERIES ORDERING INFORMATION Fike P/N Description Individual Datasheet if CyberCat 254 System,Includes Controller,Enclosure,and Transformer 10.066-c-p-L c:(R=Red,B=Black)p:(1=120V,2=240V) D.1.09.01 L=Lexan 10-2525 CyberCat 254 System Controller(included with 10-066-c-p—L) D.1.09.01 10-2519-c Dead Front Option c:(R=Red,B=Black) Optional Modules f 10-2204 CRM4-Relay Module D.1.14.01 • 10-2254 CRPM-Reverse Polarity Module 111.15.10 10-2482 Network Module D.1.17.01 10-2624 Multi-Mode Fiber Optic Network Module D.1.21.10 Peripheral Devices 10-2630 2 Button Expanded Protocol Remote Display P.1.103,01 10-2631 10 Button Expanded Protocol Remote Display P.1.107.01 10-2646 14 Button Expanded Protocol Remote Display P.1.108.01 10-2667 Zone Annunciator P.1.118.01 10-2627 Ethernet Module D.1.22.01 10-2583 Multi-Interface Module P.1.85.01 10-2528 Point ID DACT (Internal Mounting) D.1.18.01 5 of 6 olti OF go- o! 12, itc pri Intelligent Sensors ryy 63-1052 Photoelectric Smoke Sensor Non-Isolator Version P.1.88.01 63-1058 Photoelectric Smoke Sensor Isolator Version R1.88.01 'NO] 63-1053 Photo/Heat Combination Sensor Non-Isolator Version P.1.89.01 Vail Fire&Emergency Services 63-1059 Photo/Heat Combination Sensor Isolator Version R1.89.01 10/13/16 60-1039 Thermal Sensor Non-Isolator Version P.1.90.01 60-1040 Thermal Sensor Isolator Version P.1.90.01 67-033 Ion Sensor Non-Isolator Version P.1.91.01 67-034 Ion Sensor Isolator Version P.1.91.01 63-1057 Duct Sensor Non-Isolator Version P.106.01 63-1062 Duct Sensor Isolator Version P.106.01 63-1056 Duct Housing P.106.01 Intelligent Sensor Bases 63-1054 6"Sensor Base Non-Isolator Version P.1.98.01 63-1060 6"Sensor Base Isolator Version P.1.98.01 63-1055 4"Sensor Base Non-Isolator Version P.1.99.01 63-1061 4"Sensor Base Isolator Version P.1.99.01 63-1064 Sounder Base P.101.01 • 63-1063 Relay Base P.101.01 • Intelligent Modules 55-045 Mini-Monitor Module Non-Isolator Version P.1.93.01 • 55-050 Mini-Monitor Module Isolator Version P.1.93.01 55-041 4"Monitor Module Non-isolator Version P.1.92.01 55-046 4"Monitor Module Isolator Version P.1.92.01 20-1063 Intelligent Pull Station Non-Isolator Version P.1.65.01 20-1064 Intelligent Pull Station Isolator Version P.1.65.01 55-042 Supervised Control Module Non-Isolator Version P.1.94.01 55-047 Supervised Control Module Isolator Version P.1.94.01 10-2360 Series Solenoid Diode/Resistor(Needed for solenoids) 10-2413 Masterbox Interface 55-043 Relay Module Non-Isolator Version P.1.95.01 55-048 Relay Module Isolator Version P.1.95.01 55-055 Zone Interface Module Non-Isolator Version P.1.114.01 55-060 Zone Interface Module Isolator Version P.1.114.01 55-056 Dual Monitor Module Non-Isolator Version P.1.115.01 55-061 Dual Monitor Module Isolator Version P.1.115.01 Programming Parts 55-051 Infrared(IR)Remote Control Tool P.1.97.01 06-327 C-LINX Software 10-1874A Interface Communication Cable(DB9 to RJ11) 10-18746 Interface Communication Cable(USB to RJ11) — 02-11139 Communication Cable Converter(USB to DB9) 10-2477 DACT Programmer Copyright© Fike Corporation All Rights Reserved. 6 of 6 Form No. D.1.09.01-7,January 2010. Specifications are subject to change without notice. like DA INTELLIGENT MANUAL PULL STATION �0] # Fire&Emergency Services /16 DESCRIPTION The Intelligent Manual Pull Station, P/N 20-1063/20-1064,is a state-of-the-art,dual-action(i.e.,requiresPUSH IN two motions to activate the station)pull station that includes an addressable interface(mounted inside) l PULL.DOWN for Fike's intelligent CyberCat®and Cheetah®Xi control panels.Because the pull station is addressable,the control panel can display the exact location of the activated device.This leads fire service personnel quickly to the location of the alarm.The isolator version,P/N 20-1064,provides complete short circuit isolation for NFPA 72,Class X wiring. FEATURES • Aesthetically pleasing, highly visible,dual-action design Fuke • Meets ADA 5 lb.maximum pull force _ _= • Easily operated(dual-action) •, �1 • Attractive shape and textured finish • When the handle latches in down position,the word"ACTIVATED"appears at the top of the handle in bright yellow to clearly indicate the station has been operated APPROVALS: • Key/lock reset;needs only a 1/4-turn to lock/unlock • Includes Braille text on station handle • UL-56239 • Captive screw terminals wire-ready for easy connection to SLC loop(accepts up to 12 AWG/3.1 mm2 • FM wire) • CSFM-7150-0900:0144 • Meets UL 38,Standard for Manually Actuated Signaling Boxes • Maintenance personnel can open station(for inspection and testing)without causing an alarm condition • Built-in multi color LED,which is visible through the handle of the station,flashes green in normal operation and latches on steady red when in alarm UL ELECTRICAL SPECIFICATIONS APPROVED Normal Operating Voltage: 15-30VDC Standby Current: 370µA.max.Average(continuous broadcasts) Maximum Alarm Current: 2 mA(red Led on) s °. Temperature Range: 32°F—120°F(0°C—49°C) Relative Humidity Range: 10%-93%non-condensing '�a�^:i ,Rv ` INSTALLATION The 20-1063/20-1064 can be semi-flush mounted into a single-gang,double-gang,or standard 4.0"(10.16 cm)square electrical outlet box,or surface mounted. CONSTRUCTION Shell,door,and handle are molded of durable LEXAN®(or polycarbonate equivalent)with a textured finish. OPERATION Pushing in,then pulling down on the handle causes it to latch in the down/activated position.Once latched, the word'ACTIVATED"(in bright yellow)appears at the top of the handle,while a portion of the handle protrudes from the bottom of the station.To reset the station,simply unlock the station with the key and pull the door open.This action resets the handle;closing the door automatically resets the switch. Manual stations connect with two wires to one of the control panel SLC loops.Each manual station,on command from the control panel,sends data to the panel representing the state of the pull station switch. IR tool allows address setting(01-254), PRODUCT LINE INFORMATION 20-1063/20-1064 Dual-action addressable pull station.Includes key lock/reset feature. Form No.P.1.65.01-5 704 SW 10th Street • P.O. Box 610 ■ Blue Springs,Missouri 64013-0610 U.S.A. Phone:816-229.3405 • www.fike.com oti OF go DIAGRAM 4 SLC TO NEXT _ 1� 8LC OM __ADDRESSABLE Lj FACPFR _ DEVICE 0 55 i./ 1 E---;. Igo] i7 i1 r L raoDREss fl e2 c3 i_i I A ll 1 1 J 0 n� NOTE-Open/ng the pull I n i LJ n E• 10i�3�ree8 Emergency Services station door will not activate LED or deactivate the alarm ....mot switch. 0 I— -,i=Jd • too LLN NOTE-LED is visiblerriro •through translucent handle NoDOPERaaAC C �'*;,��: Normal:Flash RED Alarm:Steady Red ` 010 TIvgTED 9 F ---PI-11--- li • �, r-'7T, �,�� 1 Copyright© Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No.P.1.65.01-5,June 2014.This document shall not be used for installation purposes.Please refer to installation instructions applicable for each product. Wei OF gr Fike DA „ or, o j 1120i I° INTELLIGENT PHOTOELECTRIC DETECTOR Vail Fire&Emergency Services 10113116 DESCRIPTION The Intelligent Photoelectric,spot-type smoke detectors,P/N 63-1052&63-1058,have sensing chambers ' tom 4 that utilize the light scattering principle to detect smoke.The sensing chamber employs features that minimize the effect of settled dust on performance.The detector is designed with tri-color LEDs to indicate detector status.A remote LED annunciator,P/N 02-3868,is available as an accessory.It can be configured to follow the detector LED operation or be independently controlled.The isolator version,P/N 63-1058, provides complete short circuit isolation for NFPA 72,Class X wiring if used with an isolator base. The detector is compatible with Fike's CyberCat®and Cheetah®Xi intelligent control panels.Its operating APPROVALS: parameters are configured using the panel's programming software and are stored within non-volatile RAM • UL-5911 in the detector.This on-board intelligence allows each detector to communicate its status directly to other • FM devices connected to the panel.This peer-to-peer digital protocol results in less information that needs to be • MEA-7-05-E sent between the detector and the host control panel,resulting in faster,more reliable communication. • CSFM-7272-2010:0100 SPECIFICATIONS Normal Operating Voltage: 15 to 30 VDC Standby Current: 481µA max.@ 24 VDC(continuous broadcasts) Alarm Current: 2 mA max.@ 24 VDC(LEDs on) Humidity Range: 10%to 93%Relative Humidity,non-condensing Temperature Range: 32°F to 120°F(0°C to 49°C) APPROVED Height: 2.1 inches(51 mm)installed in 63-1054 Base Diameter: 6.1 inches(155 mm)installed in 63-1054 Base 4.1 inches(104 mm)installed in 63-1055 Base Weight: 5.2 oz.(147 g) Detector Spacing: In compliance with NFPA 72 Velocity Range: 4000 FPM(1219 m/min.) ORDERING INFORMATION Fike P/N Mfg.Model Description 63-1052 63-1052 Photoelectric Smoke Detector-Non-Isolator 63-1058 63-1058 Photoelectric Smoke Detector-Isolator Mounting Bases 63-1054 EBF 6”Flanged Mounting Base-Non-Isolator 63-1060 EBFI 6"Flanged Mounting Base-Isolator 63-1055 EB 4"Flangeless Mounting Base-Non-Isolator 63-1061 EBI 4"Flangeless Mounting Base-Isolator 63-1063 EBR Relay Base 63-1064 EBS Sounder Base Accessories 20-1085 F110 Retrofit Flange 02-3868 RA100Z Remote LED Annunciator 20-1087 XR2B Detector Removal Tool 02-4986 XP-4 Extension for 20-1087(5-15 ft) I I' 20-1089 BCK-200B Black Detector Kit(10 pack) • 55-051 EA-CT IR Tool • Form No. P.1.88.01-4 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone:816.229.3405 • www.fike.com olti OF go .,„"st,e .4•1410 lo # .rri IP- if Vail Fire&Emergency Services 10/13/16 (This page is left blank intentionally) Copyright© Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.88.01-4,March 2014.This document shall not be used for installation purposes.Please refer to installation instructions applicable for each product dill OF pi , ke, .i.- 41 DA .171 j INTELLIGENT O] HEAT DETECTOR Vail Fire&Emergency Services 10/13/16 DESCRIPTION The Intelligent Heat Detector, P/N 60-1039&60-1040,is a fixed temperature/rate-of-rise detector that can be programmed for a discrete set-point within the range of 135-170°F for ordinary detection, • or 175-190°F for intermediate detection.Detectors in the ordinary range may be programmed for either fixed temperature or 15°F rate-of-rise operation.Detectors in the ordinary range are programmed for fixed temperature only.The detector is designed with tri-color LEDs to indicate detector status.A remote LED annunciator,P/N 02-3868,is available as an accessory.It can be configured to follow the sensor LED operation or be independently controlled.The isolator version,P/N 60-1040,provides complete short circuit isolation for NFPA 72,Class X wiring if used with an isolator base. APPROVALS: The detector is compatible with Fike's CyberCat®and Cheetah®Xi intelligent control panels. Its operating • UL-S2101 parameters are configured using the panel's programming software and are stored within non-volatile RAM • FM in the detector. This on-board intelligence allows each detector to communicate its status directly to other • City of New York-63-05-E devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to • CSFM-7270-0900:0152 be sent between the detector and the host control panel,resulting in faster,more reliable communication, - SPECIFICATIONS Normal OperatingVoltage: 15 to 30 VDC 1:* Curell Standby Current: 451µA max.@ 24 VDC(continuous broadcasts);63-1039 i 451µA max.@ 24 VDC(continuous broadcasts);60-1040 Alarm Current: 2 mA max.@ 24 VDC(LEDs on) °"""oYE° Operating Humidity Range: 10%to 93%Relative Humidity Non-condensing Installation Temperatures: -4 to 100°F(-20 to 38°C);135-174°F setpoint . _ -4 to 150°F(-20 to 66°C);175-190°F setpoint Fixed Temperature Rating: 135°F(57°C)to 190°F(88°C);programmable Rate of Rise Detection: Responds to greater than 15°F/min.(8°C/min.);programmable Spacing for Thermal Detectors: Detectors set between 135 to 155oF or 175 to 190oF: :` v - p g l "1 50 ft(15.24 m)spacing 0 Detectors set between 160o to 170oF:15 ft.(4.57 M)spacing Height: 2.1 inches(51 mm)in 63-1054 base Diameter: 6.1 inches(155 mm)installed in 63-1054 base 4.1 inches(104 mm)installed in 63-1055 base Weight: 4.8 ounces(137 g) ORDERING INFORMATION Fike P/N Mfg.Model Description 60-1039 60-1039 Fixed Temperature/Rate-of-Rise Heat Detector-Non-isolator 60-1040 60-1040 Fixed Temperature/Rate-of-Rise Heat Detector-Isolator Mounting Bases 63-1054 EBF 6"Flanged Mounting Base-Non-Isolator 63-1055 EB 4"Flangeless Mounting Base-Non-Isolator 63-1060 EBFI 6"Flanged Mounting Base-Isolator 63-1061 EBI 4"Flangeless Mounting Base-Isolator 63-1063 EBR Relay Base 63-1064 EBS Sounder Base Accessories ' 20-1085 F110 Retrofit Flange • 02-3868 RA100Z Remote LED Annunciator + :., 20-1087 XR2B Detector Removal Tool 02-4986 XP-4 Extension for 20-1087(5-15 ft) . l 20-1089 BCK-200B Black Detector Kit(10 pack) 55-051 EA-CT IR Tool N. I • Form No. P.1.90.01-5 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone:816.229.3405 • www.fike.com 14,lt:i OF iv N."14. 4,4015' Is Is IITI. Ir Vail Fire&Emergency Services 10113116 (This page is left blank intentionally) Copyright© Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.90.01-5,March 2014.This document shall not be used for installation purposes.Please refer to installation instructions applicable for each product. ...„„,,„„„„„„lif:0 4, like I, ir 44:53 1541' MONITOR MODULE 12 I# if Oji . ft rvices DESCRIPTION • The Monitor Module,P/N 55-041&55-046,provides a single,Class A or B initiating device circuit(IDC) • capable of monitoring normally open contact fire alarm and supervisory devices or normally closed • supervisory/process devices, In addition to monitoring the connected contacts,the module will monitor the • " wiring to the device for open circuits via an end of line resistor(Class B only).The module has a multi-color - LED that will flash a unique color for instant status indication(Green for normal operation,Red for active input,Yellow for trouble at device).The isolator version of the module,P/N 55-046,provides complete short Ilk 411 circuit isolation for installations requiring NFPA,Class X wiring. - The module is compatible with Fike's CyberCat®and Cheetah®Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module. This on-board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to APPROVALS: be sent between the module and the host control panel,resulting in faster, more reliable communication, • UL-S3705 • FM SPECIFICATIONS • City of New York-8-05-E • CSFM - 7300-2010:0101 Normal Operating Voltage: 15 to 30 VDC Standby Current: 485µA max.(continuous broadcasts) IDC Voltage: 5,4 VDC max. Alarm Current: 2.0 mA(red LED on) Maximum IDC Wiring Resistance: 100 0 Temperature Range: 32 to 120°F(0 to 49°C) Humidity: 10 to 93%RH Noncondensing Dimensions: 4.17"H x 4.26"W x 1.22"D(106 mm H x 108 mm W x 31 mm D) 4:* U Accessories: 39 kfO End of Line Resistor(P/N 10-2625 included) Wall cover plate(included) APPROVED 20-1072 Surface Mount Electrical Box 14 kf2 Short Detect Resistor,P/N 10-2530,must be ordered separately Mounting: Mounts on 4"square electrical boxes with 2 1/8"minimum depth. W For surface mounting,use 20-1347 surface mount box. .,-,, ' :I ORDERING INFORMATION Fike P/N Mfg.Model Description SS-041 55-041 Monitor Module-Non-isolator 55-046 55-046 Monitor Module-Isolator Accessories r 20-1346 CBB500 Control Module Barrier 20-1347 SMB500 Surface Mount Box 55-051 EA-CT IR Tool 10-2625 39 kf�End of Line resistor 10-2530 14 kO Short Detect resistor 13-0192 C58-004-000 COVERPLATE Form No. P.1.92.01-6 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone:816.229.3405 a www.fike.com iitlei OF gr, 4...:: MODULE DIMENSIONS i * 1a� C 4.263 - 1.585 Ir ' 2.973 • 4 ' o MDNROR - ;�f '-112 1# 0.937 1.100 0 O Vail Fire&Emergency Services ITOP 0 I 10113116 ;� '"" �1 c704.171 pi a v ® 2.735 0 Iso in � y a cv to T y_J (LOOP (ADDRESS) 1+II" 1_ 1.100 -- _1 U L i .. ��.6L:"—•—— -im. . 1111M - 0.639 -- I- —2.955 TERMINAL DEFINITIONS T1 (+)SLC in/out T6 No Connection T2 (-)SIC in/out T7 (-)IDC Class A/B T3 (+)SLC in/out T8 (+)IDC Class A/B T4 (-)SLC in/out T9 (+)IDC Class A T5 No Connection T10 (-)IDC Class A Copyright© Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.92.01-6,March 2014.This document shall not be used for installation purposes.Please refer to installation instructions applicable for each product. Nr41111111111111111101ii. . 0 t.por fill FikeIS IMF DA ir oj 11, MONITOR MODULE -1120145 ,i Mt It rvices DESCRIPTION The Monitor Module,P/N 55-041&55-046,provides a single,Class A or B initiating device circuit(IDC) $ capable of monitoring normally open contact fire alarm and supervisory devices or normally closed S supervisory/process devices.In addition to monitoring the connected contacts,the module will monitor the • wiring to the device for open circuits via an end of line resistor(Class B only).The module has a multi-color LED that will flash a unique color for instant status indication(Green for normal operation,Red for active input,Yellow for trouble at device).The isolator version of the module,P/N 55-046,provides complete short circuit isolation for installations requiring NFPA,Class X wiring. The module is compatible with Fike's CyberCat®and Cheetah®Xi intelligent control panels. Its operating parameters are configured using the panel's programming software and are stored within non-volatile RAM in the module. This on-board intelligence allows each module to communicate its status directly to other devices connected to the panel. This peer-to-peer digital protocol results in less information that needs to APPROVALS: be sent between the module and the host control panel,resulting in faster,more reliable communication. • UL-S3705 • FM SPECIFICATIONS • City of New York-8-05-E •Normal Operating Voltage: 15 to 30 VDC CSFM 7300-2010:0101 Standby Current: 485µA max.(continuous broadcasts) : IDC Voltage: 5.4 VDC max. ► Alarm Current: 2.0 mA(red LED on) y Maximum IDC Wiring Resistance: 100 0 Temperature Range: 32 to 120°F(0 to 49°C) • Humidity: 10 to 93%RH"W x densing �� Dimensions: 4.17"H x 4.26"W x 1.22" D(106 mm H x 108 mm W x 31 mm D) 41> Accessories: 39 kid End of Line Resistor(P/N 10-2625 included) ''1 Wall cover plate(included) APPROVED 20-1072 Surface Mount Electrical Box 14 kid Short Detect Resistor, P/N 10-2530, must be ordered separately Mounting: Mounts on 4"square electrical boxes with 21/8"minimum depth. I ,i For surface mounting,use 20-1347 surface mount box. • ORDERING INFORMATION I Fike P/N Mfg.Model Description • 55-041 55-041 Monitor Module-Non-isolator 55-046 55-046 Monitor Module-Isolator Accessories 20-1346 CBB500 Control Module Barrier 20-1347 SMB500 Surface Mount Box 55-051 EA-CT 1 IR Tool 10-2625 39 kO End of Line resistor • 10-2530 14 kQ Short Detect resistor 13-0192 C58-004-000 COVERPLATE Form No.P.1.92.01-6 704 SW 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013-0610 U.S.A. Phone:816.229.3405 • www.fike.com iitlei OF gr, MODULE DIMENSIONS C 4.283 1,585 I — 2973AlWatt ---- ' 120 1 MONROR I 0.937 1.100 O - O Vail Fire&Emergency Services LTOP 0 10113116 o ,�� it a `�& . 0 �=' �� 4,171 0 ® 2.735 0 co 0 oo Loco I l0 • LOOPADDRESS J 0f 1.-pnoaess 1[ 1 ( 1 `C ) O 1.100 —1 Li Li L •7 [ I. 0.639 -- - -- 2.985 TERMINAL DEFINITIONS T1 (+)SLC in/out T6 No Connection T2 (-)SLC in/out 17 (-)IDC Class A/B T3 (+)SLC in/out T8 (+)IDC Class A/B T4 (-)SLC in/out T9 (+)IDC Class A T5 No Connection T10 (-)IDC Class A Copyright© Fike Corporation All Rights Reserved. Specifications are subject to change without notice. 2 of 2 Form No. P.1.92.01-6,March 2014.This document shall not be used for installation purposes.Please refer to installation instructions applicable for each product.