Loading...
HomeMy WebLinkAboutA16-0062_Scope of Work_1478896738.pdf 401611 OF go.,. C"Ii WC) ® NOTIF * ' Vail Fire&Emergency Services 10/26/16 Commercial Specialists of ZOestern 3oloraato, LLC Wednesday, October 12, 2016 Vail Fire 42 West Meadow Drive Vail, CO 81657 Attn: Mike Vaughan, Fire Marshal Pjct: Doubletree Remodel Re: Scope of Work for Fire Alarm System Alteration Dear Mike, The following is a scope of work to be performed for the conversion of the Holiday Inn to the new Doubletree in West Vail. The scope of work will be today bring the remodeled area up to NFPA standards adopted by Vail Fire. Work performed will be to remove all smoke detection and bases during the remodel to prevent device contamination. 1st Floor Scope: All of the existing detection on this floor will be removed, except above the fire panel and for elevator recall to match current IBC / IFC. All of the pull stations, water flow and tamper devices will remain as installed. New control panel electronics will be replaced with new UL 9th edition panels to accommodate new features and bring the system up to the latest standards. The existing dialer will be replaced with a new IP communicator connected to the Doubletree network for off site notifications. The existing annunciator will be relocated and mounted behind the new check-in desk location. All notification devices will be replaced with new ceiling mount devices. No work will be completed in the first floor tenant spaces or the second floor tenant space. 2nd - 5th Floor: All of the existing notification devices and circuits will remain as installed. All corridor detection will remain as currently installed, but removed for construction. Once the room reconditioning has been completed new low frequency sounder bases will be installed. The existing detectors will be re-installed in the new sounder bases and the existing corridor detector base will be re-installed with the existing devices. The 4th -5th floor unit living room detection will be replaced with new Combination Smoke/Heat/CO detectors to provide detection for the fire places. 210 Marmot Lane Unit 5B* PO Box 3913* Eagle, Colorado 81631 Voice(970)328.1951 Fax(970)328.1956 www.cswcfire.com itari T.;. CIPS Ws C) NOT I FIFEJ � # Vail Fire&Emergency Services 10/26/16 Commercial Specialists of ZOestern 3oloraato, LLC Once work has been completed and tested, CSWC will contact Vail Fire Department and schedule a final fire alarm test of the new area. If there are any questions or concerns about the above information, please feel free to contact me at any time. Sincerely, Commercial Specialists of Western Colorado, LLC 7(m YUcotog Tim Ward General Manager 210 Marmot Lane Unit 5B* PO Box 3913* Eagle, Colorado 81631 Voice(970)328.1951 Fax(970)328.1956 www.cswcfire.com