HomeMy WebLinkAboutA16-0064_FA0.00_1478896808.pdf islei OF gr.. etVa Vail Fire&Emerpncy Services MATTERHORN INN CONDOMINIUMS 10/26/16 FIRE ALARM SYSTEM VAIL COLORADO FIRE ALARM SYSTEM LEGEND WIRING LEGEND SYMBOL DESCRIPTION MANUFACTURER OPERATING MOUNTING HEIGHT BACKBOX REMARKS MODEL NUMBER VOLTAGE SYMBOL WIRE TYPE USED ON STRAND COLORS VIGILANT TOP OF CABINET AT 1.83 M. (6 FT.) AFF OR FACP FIRE ALARM CONTROL PANEL 120 VAC CENTER AT 1.52 M. (5 FT.) AFF INCLUDED WALL MOUNTED VS1 G WHICHEVER IS LOWER FIRE ALARM SYSTEM SEQUENCE OF OPERATIONS 1D 2-CONDUCTOR, #16 AWG, FIRE ALARM RED (+) VIGILANT TOP OF CABINET AT 1.83 M. (6 FT.) AFF OR SOLID TWISTED CABLE, FPL OR NPLF ADDRESSABLE CIRCUIT BLACK (-) BPS REMOTE BOOSTER POWER SUPPLY PANEL MIRBPS6A 120 VAC CENTER AT 1.52 M. (5 FT.) AFF INCLUDED WALL MOUNTED WHICHEVER IS LOWER 1 2 3 4 NOT1P 2 CONDUCTOR, #14 AWG, 24 VDC RED (+) LESS THAN 10.16 CM. (4") TO CORNERS VIGILANT STANDARD 101.6 MM. 0 SOLID, FPL OR NPLF CIRCUIT BLACK (-) Op PHOTOELECTRIC SMOKE DETECTOR V-PS 15.2-19.95 VDC OR BETWEEN 10.16 CM. (4") TO 30.48 CM. (4") SQUARE BOX CEILING MOUNTED (12") FOR WALL MOUNTING SYSTEM OUTPUT BLACK - HOT VIGILANT 15.2-19.95 VDC NOT LESS THAN 10.16 CM. (4") TO CORNERS ! 3-CONDUCTOR, #12 AWG PHOTOELECTRIC SMOKE DETECTOR WITH LOW & 16-33 VDC STANDARD 101.6 MM. �/ 120 VAC WHITE NEUTRAL (DP,SB FREQUENCY AUDIBLE (SOUNDER) BASE V-PS FOR AUDIBLE OR BETWEEN 10.16 CM. (4") TO 30.48 CM. (4") SQUARE BOX CEILING MOUNTED P� SOLID, GREEN - GROUND WITH SB4U-LF BASE (12") FOR WALL MOUNTING �� VIGILANT STANDARD SINGLE GANG BOX �� EXAMPLE: QUANTITY OF PAIRS TP TEMPORAL PATTERN GENERATOR GSA-T3T4 15.2 19.95 VDC 64 MM. (2 1/2") DEEP WALL MOUNTED �� 2 D AWG #16, SOLID TWISTED CABLE \)4C)<</ El SINGLE INPUT MODULE VIGILANT 15.2-19.95 VDC STANDARD SINGLE GANG BOX WALL MOUNTED "PGQ �O GSA-CT1 64 MM. (2 1/2") DEEP <C ,(5% (j RM RISER MONITOR MODULE VIGILANT 15.2-19.95 VDC STANDARD 101.6 MM. WALL MOUNTED QGQ ��P� Q, J�\� NOTE: GSA-RM1 (4") SQUARE BOX Q Q 1. USE TYPE FPLR OR NPLFR FOR CABLES INSTALLED IN VERTICAL RUNS AND PENETRATING P'S J�Gj \� !Q MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN A SHAFT. -MA,- END-OF-LINE RESISTOR � Q�Q' OJT G`Q'� 2. USE TYPE FPLP OR NPLFP FOR CABLES INSTALLED IN DUCTS, PLENUMS AND OTHER P� �2 O SPACES USED FOR ENVIRONMENTAL AIR. NP JAG\\?) \f) JAG\ JP�� PANEL CIRCUIT DISTRIBUTION SCHEDULE SYSTEM INPUT Q�� P�� PS c')\ FIRE ALARM SYSTEM NOTES PANEL NAME CARD LABEL AUX OR NAC CIRCUIT NUMBER DEVICE USED AREA COVERED ALARM ACTIVATION BATTERY CAPACITY '4 SMOKE DETECTOR WITH STANDARD BASE 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72. NUMBER (MODULE ADDRESS) USED AT FIRE SPRINKLER RISER ROOM X A D1 DETECTORS 2. ALL SIGNAL INITIATING DEVICE CIRCUITS SHALL BE CLASS B SUPERVISED. ALL SIGNALING LINE CIRCUITS SHALL BE CLASS B SUPERVISED. SLC #1 M1 MODULES ALL AREAS B SMOKE DETECTOR WITH SOUNDER BASE X X B 24 VDC AUX #1 SPARE AT ROOM UNIT 3. ALL FIRE ALARM CONDUIT SHALL BE 19mm (3/4") MINIMUM, ADJUST CONDUIT SIZE ACCORDING TO WIRE COUNTS AS PER NATIONAL FACP 24 VDC AUX #2 SPARE 2 ea. 7.2 AH ELECTRICAL CODE. C SPRINKLER WATERFLOW SWITCH X C NAC #1 SPARE 4. SEPARATE CONDUITS SHALL BE USED FOR 120 VAC AND 24 VDC CIRCUITS. NAC NAC #12SPARED SPRINKLER PRESSURE SWITCH X D 5. SMOKE DETECTORS SHOULD NOT BE LOCATED NO CLOSER THAN 0.914 m (3') FROM ALL AIR SUPPLY DIFFUSER, RETURN AIR OPENING, 24 VDC SUPPLY SOUNDER BASE SMOKE DETECTOR SOUNDER BASE AT ALL ROOM UNITS BATHROOM DOORS, LIGHTING FIXTURES AND OTHER ELECTRICAL EQUIPMENTS THAT MAY EMIT NOISE/EMF. BPS1 NAC #2 SPARE 2 ea. 11 AH E SPRINKLER TAMPER SWITCH X ' E NAC #3 SPARE 6. REMOVE DEVICE SERIAL NUMBER LABELS AND PLACE ON FIELD DRAWINGS FOR LOCATION DESCRIPTIONS AND PROGRAMMING PURPOSES ONLY. NAC #4 SPARE F SYSTEM TROUBLE X F 7. USE SCREW TERMINAL BLOCKS FOR ALL WIRE TERMINATIONS, DO NOT USE WIRE NUTS. G SYSTEM SUPERVISORY )( G 8. DO NOT ENTER ENCLOSURES FROM THE BOTTOM, THIS IS FOR THE BATTERIES. 9. THE LOCATION OF THE CIRCUIT DISCONNECT MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. INDEX OF DRAWINGS 1 2 3 4 DRAWING NUMBER DRAWING TITLE FACP (VS1-G) Battery Calculation Model/Description Qty. Standby Total Standby Alarm Total Alarm FA0.00 FIRE ALARM SYSTEM OTHER DETAILS (mA) (mA) (mA) (mA) VBPS1 (MIRBPS6A) Battery Calculation S1-G,Base Panel 1 155 155 204 204 FA1.01 FIRE ALARM SYSTEM PLAN Qty Model Description Supv Alarm Total Supv Total Alarm VS1-G,Primary Loop Circuit 1 55 55 125 - 125 Current(A) Current(A) Current(A) Current(A) 1 MIRBPS6A Control Board 0.070 0.270 0.070 0.2700 V-PS,Smoke Detector 28 0.045 1.26 0.045 1.26 1 Number of NAC 0.035 0.000 0.035 0.0000 GSA-T3T4,Temporal Pattern Generator(TC3) 1 0.053 0.053 0.373 0.373 - set to AUX GSA-CT1,Single Input Module 3 0.25 0.75 0.4 1.2 _ 27 SB4U-LF Audible Base 0.006 0.000 0.162 0.0000 (Supervisory) - GSA-RM1,Riser Monitor Module 1 i 0.2 0.2 0.2 0.2 1 SB4U-LF Audible Base 0.000 0.076 0.000 0.0760 (Alarm) TOTAL: 212.26 TOTAL: 332.03 A Devices total supervisory current(from the above chart): 0.267 (mA) (mA) B Required battery standby capacity(As per Project Specification) 24 SUPERVISORY HOURS: 24 C Supervisory Current Required: 6.408 D Devices total alarm current(from the above chart): 0.3460 ALARM MINUTES: 5 E Required alarm sounding period(As per Project Specification) 5 F Alarm Current Required: 0.0288 Minimum Battery Size(Ah) 5.12 G Total Alarm and Supervisory Current(in amp-hour)Required: 6.44 H Total Alarm and Supervisory Current(in amp-hour)Required Plus 20%Spare: 7.72 Total Alarm&Supervisory Current Required(in amp-hr)plus 20% spare: 6.1463777 Battery size to be supplied: 2 ea. 12 Volts-11 Ah Project Name: (Matterhorn Inn Condominiums,1552 Matterhorn Circle,Vail,Colorado Battery size to be supplied: 2 ea. 12 Volts-7.2 Ah 'Date:10/18/16 0 1P Project Name: Matterhorn Inn Condominiums,1552 Matterhorn Circle,Vail,Colorado © © © © © © © © © © OZ R M Date:10/18/16 P,SB P,SB P,SB P,SB P,SB P,SB P,SB P,SB P,SB P,SB P,SB D1-18 D1-19 D1-20 D1-21 D1-22 D1-23 D1-24 D1-25 D1-26 01-27 01-281D M1-6 UNIT 11 UNIT 10 UNIT 9 UNIT 8 UNIT 7 UNIT 6 UNIT 5 UNIT 4 UNIT 3 UNIT 2 UNIT 1 DEVICES MOUNTING HEIGHT DETAILS ©P,SB ©P,SB ©P,SB ©P,SB ©P,SB ©P,SB ©P,SB ©P,SB OP,SB D1-9 01-10 D1-11 01-12 D1-13 01-14 D1-15 D1-16 D1-17 L UNIT 6 _1 UNIT 7 L UNIT 8 _1 UNIT 9 L UNIT 10 _1 UNIT 1 1 120 VAC CONDUITS NOTE: 0 M1-3 M1-4 M1-5 CONFIGURE THE NAC #1 OF BPS1 1P M M M © © © © © © FINISHED CEILING REV DESCRIPTION DATE APPROVED O O TO AUXILIARY 24 VDC SUPPLY - P P,SB P,SB P,SB P,SB P,SB P,SB P,SB REVISIONS FOR SOUNDER BASE. V V V D1-1 D1-2 D1-3 D1-4 D1-5 D1-6 D1-7 D1-8 FLOOR PLANS PROVIDED BY: PHONE WATERFLOW PRESSURE TAMPER UNIT 1 L UNIT 2 UNIT 3 L UNIT 4 UNIT 5 FOR: PHONE SWITCH SWITCH SWITCH IDRAWN BY: DATE a 1P ANO 10/18/2016 z FIRE SPRINKLER RISER ROOM ridi ' an CHECKED BY: DATE 3 P S 1 FA CP SLC #1 0 TP I q I me rMo u nta in APPROVED BY: 1D MMi-i I 1-2 1D FACP ~ (OPTIONAL) FIRE SPRINKLER OR - CONDUIT KNOCKOUTS Fire 8i:Security A. _/' RISER ROOM f BPS �__ 183 cm 152.4 cm * NO CONDUIT INTO ALBE'T 7=771-MANN (72") OR (60") THE BOTTOM OF NICET LEVEL IV 98794 TO DEDICATEDTO TOP TO CENTER THESE BOXES 0 0 - 120v Ac I MERIDIAN INTERMOUNTAIN FIRE & SECURITY BRANCH CIRCUIT Whichever P.O. BOX 3940 AVON CO, 81620 FIRE SPRINKLER RISER ROOM is lower * EXCEPTION: IF A BATTERY CABINET IS REQUIRED TEL. NO. (970) 748-8888 FOR THE FIRE ALARM CONTROL PANEL, ONLY THEN MATTERHORN INN CONDOMINIUMS MAY CONDUIT PENETRATE INTO BOTTOM OF THE FINISHED FLOOR FIRE ALARM CONTROL PANEL. VAIL, COLORADO FIRE ALARM SYSTEM FIRE ALARM SYSTEM RISER DIAGRAM OTHER DETAILS APPROX. SCALE DWG NO. REV NOT TO SCALE SHEET NO. FAO. 00 SCALE: NONE 1 OF 2