IFC2015 Occupancy Class - Residential multi- Vail Fire&Emergencl Services11/01/16
BATTERY CALCULATIONS SYSTEM OUTPUTS family 907. 2. 11 . 2 Group R- 3. Single o r
CONTROL PANEL SUPERIOR ALARM &
LOCATION: 1st Level Mechanical ANNUNCIATION NOTIFICATION multiple station smoke alarms shall b e ELECTRONICS, INC.
PANEL: GE Concord 4
HOURS OF SUPERVISION: 24 HOURS installed regardless of occupant load at
MINUTES OF ALARM: 15 MIND IFSall of the following locations: 210 Edwards Village Blvd
0.I ° #A108
Device Device Total a 1 . On ceilingor wall outside each separate
QTY PART KUNIBER Standby Alarm Standby Total Alarm M t s o r'
C�inTent f`' Edwards, Colorado 81632
DESCRIPTION OF DEVICES Current Current Current a c 5 . sleeping area.
1 GE Concord 4 FACP 0.0000 0.0000 0.0000 0.0000 - 2 A H H ' 5. P) 970-926-8788
2 ATP-1000 Annunciator 0.0120 0.1100 0.0240 0.2200 c b o F �- � o 2. I n each room used for sleeping
1 60-758 4 output snapcard 0.0060 0.0400 0.0060 0.0400 0 Q Q 8 Q 3. In each story within dwelling unit Property:
4 ESL 40503 Reversal Relay0.0000 0.0570 0.0000 0.2280 °' E; ' 7
�� � � � � � y � v � .� � � 7.7'
5 SYS 4V6'TAB Monitored Smoke Detector 0.0001 0.0350 0.0003 0.1750 1 a 0 0 ca 1 h ' N .1 Korch
1 60-774 8 Zone Expansion Module 0.0380 0.2300 0.0380 0.2300 S F ¢ i; I NFPA 72 2016 29. 5. 1 . 1 Smoke alarms shall be installed: Residence
o m g a
4 ESL 26000 Monitored Carbon Monoxide Detector 0.0020 0.0400 0.0080 0.1600 ' ' g g .F 5, 1 . In all sleeping rooms and guest rooms
1 SYS-MEW Interior Siren 0.0000 0.0750 0.0000 0.0750 ¢ .0 .0 H H a " c 0
1 SYS-5603 135 degree fixed heat detector 0.0000 0.0000 0.0000 0.0000
y c m c 2. Outside of each sleeping area within 21 ft of door
V. � �, �, o Address:
TOTAL: 0.076 1.128 - d H F H z 3. On everylevel , includingbasements.
Smoke or Heat Detector X X X X X
4284 Columbine Drive
STANDBY
Carbon Monoxide Detector X X X X X 4. In living areas of guest suite Vail, Colorado 81657
SUB-TOTAL: 0.08 AMP Ground Fault X X X X
24 HOURS OF STANDBY: 24.00 HOURS Open Circuit X X X X X
SUB-TOTAL: 1.83 AMP HOURSLow Battery X X X X X Owner:
ALARM: _
AC Power Failure X X X X X N F P A 720 Brad Korch
SUB-TOTAL: 1.13 AMP Telephone Line Fault-daily timer test X X X 8. 4. 1 . 1 Carbon monoxide detectors shall be installed: 4284 Columbine Drive
Vail, Colorado 81657
15 MINUTES OF ALARM: 0.25 HOURS Panel Silence Feature X X
SUB-TOTAL: 0.28 AMP HOURS 1 . Outside each sleeping area in immediate vicinity. General Contractor:
TOTALS: 2. On every level Iconic Development
TOTAL SUPERVISORY: 1.83 AMP HOURS Nice job. Approved for install. PO Box 1734
3. Other location where required by law, code or standard. Vail, CO 81657
TOTAL ALARM: 0.28 AMP HOURS
Ph. 720-428-0691
TOTAL: 2.11 AMP HOURS
GC: Steve Sandoval
*SPARE OF20% 0.42 AMP HOURS HB1091 Single Family Homes: Carbon monoxide detectors shall
MINIMUM BAIL FRY SIZE REQUIRED 2.53 AMP HOURS
BAIIERIES SUPPLIED 2 x 7 amp 7.00 AMP HOURS be installed within 15 feet of bedroom door. Code Complience:
2015 International Fire Code
2016 NFPA-72 Nat. Fire Alarm Code
BATTERY CALCULATIONS: MAIN ALARM CONTROL PANEL VAI L FIRE INSTALLATION STANDARDS (Rev 4/16)•
2014 NFPA-70 Nat. Electrical Code
Detection location and spacing shall be per latest NFPA72
2015 IFC and as set forth : Levels:
3 Levels
1 . Installed in a corridor not more than fifteen feet from
Bldg Height:
the door of the farthest bedroom 14rf Roof Height
2. Smokes req'd in living rooms, family rooms, home Occupancy Loads:
theaters and any rooms that may be used for sleeping.
3. Detectors installed toward middle of room with Occupancy Rating:
consideration of bathrooms, ceiling fans and air ducts. Residential - R-3
4 Kitchens and garages are not required to have heat Structure: -
CO TH I D FLOOR detection . Type VB/Non-Rated/Non-Sprinkled
5. Storage rooms, closets, unfinished crawl spaces not Sq. Footage:
required to have smoke detection . 2,972 SgFt±
OOCO CO T
SECOND FLOOR Carbon Monoxide detection required per latest NFPA72 and Communication Type:
r Colorado HB1091 . In addition : DACT/POTSLines
1 . CO to be instaled no further than 15 feet from furthest Primary Power Location:
CC Bell 1 Main Elec Panel- Breaker#
ANN - eo FIRST FLOOR bedroom . Submittal Prepared By:
GE 2. Within 20 feet of fuel fired appliances, including stoves,
Concord 4 gas, fire places, wood burning stoves or wood burning fire r- --..\
FACP SAE
PANEL places.
I I RISER DIAGRAM 3. Entrance vestibules from attached garages.
Phonelines (1) 120 VAC Superior Alarm & Electronics
Dedicated 4. Areas with gas fired appliances that pose safety risk. 210 EdwardsVill. Blvd. #A108
12VDC 8 AH
Batt Backup PH 970-926-8788
FX 970-926-8790
/ System Code e f e r e n c e / brad@superioralarmco.com
SYMBOL DESCRIPTION MONITORING
API - DENVER COLORADO
FACP FIRE ALARM CONTROL PANEL OARM ADDRESSABLE RELAY MODULE REMOTE STATION
SMOKE DETECTOR (PHOTOELECTRIC) Ell HORN/SOUNDER
SYS# 6101-1759
DESCRIPTION CLASS STYLE TYPE HORN WITH STROBE m135 ROR (TEMP LISTED
/ )HEAT DETECTOR FIXEDTorr NATIONAL INSTITUTE FOR CERTIFICATION
\ IN ENGINEERING TECHNOLOGIES
NOTIFICATION APPLIANCE CIRCUIT B Y 4 #18 AWG FPL 15 (NUMBER INDICATES CANDELA) Fire Protection Engineering Technology
A significant remodel of an existing single family residence is taking ANN ANNUNCIATOR ^I5 STROBE (NUMBER Fire Alarm Systems
lace in the Town of Vail . The residence will not be sprinklered. AC POWER B Y 4 #18 AWG FPL P•� INDICATES CANDELA)
p p INITIATING DEVICE CIRCUITS 4 #18 AWG FPL t-�-1 WATER FLOW SWITCH "
We will install smoke and carbon monoxide combination devices inEOL END OF LINE RESISTOR
t-II-1 VALVE WITH TAMPER SWITCH RE
applicable locations and system will be zoned by floor. Our k FIRE DEPARTMENT "KNOX" BOX
USE PLENUM RATED WIRE IN ALL PLENUM SPACES OAIM ADDRESSABLE INPUT MODULE Matt Madden
installation will meet Town o f Vail Standards and applicable codes. 0MONITORED CARBON MONOXIDE DETECTOR NICET #134111 Level III
Scope of Work / C
WIRE CHART n 0 SMOKE/CARBON MONOXIDE COMBO DETECTOR Valid Thru 05/01/18
ORIG.6/16/16 SCALE: 1/8"=1'0"
LEGEND REV. DATE NOTES:
0
A
A
FINAL INSP.
AS BUILTS:
AHJ: Vail Fire Department
Mike Vaughan, Fire Marshall
Permit #:
Index: PAGE NAME: Title/Bldg/Calcs/Map
FA-0 Cover Page A 0
AHJ : Vail Fire - Fire Marshal Mike 970-479-2252
SHEET
1 OF 4 J