HomeMy WebLinkAboutA16-0068_FA-0_1478896861.pdf ..4141111140. I INSTALLATI• Z +�� e f:i ig40 -j-k(0 #fib IFC2015 Occupancy Class - Residential multi- Vail Fire&Emergencl Services11/01/16 BATTERY CALCULATIONS SYSTEM OUTPUTS family 907. 2. 11 . 2 Group R- 3. Single o r CONTROL PANEL SUPERIOR ALARM & LOCATION: 1st Level Mechanical ANNUNCIATION NOTIFICATION multiple station smoke alarms shall b e ELECTRONICS, INC. PANEL: GE Concord 4 HOURS OF SUPERVISION: 24 HOURS installed regardless of occupant load at MINUTES OF ALARM: 15 MIND IFSall of the following locations: 210 Edwards Village Blvd 0.I ° #A108 Device Device Total a 1 . On ceilingor wall outside each separate QTY PART KUNIBER Standby Alarm Standby Total Alarm M t s o r' C�inTent f`' Edwards, Colorado 81632 DESCRIPTION OF DEVICES Current Current Current a c 5 . sleeping area. 1 GE Concord 4 FACP 0.0000 0.0000 0.0000 0.0000 - 2 A H H ' 5. P) 970-926-8788 2 ATP-1000 Annunciator 0.0120 0.1100 0.0240 0.2200 c b o F �- � o 2. I n each room used for sleeping 1 60-758 4 output snapcard 0.0060 0.0400 0.0060 0.0400 0 Q Q 8 Q 3. In each story within dwelling unit Property: 4 ESL 40503 Reversal Relay0.0000 0.0570 0.0000 0.2280 °' E; ' 7 �� � � � � � y � v � .� � � 7.7' 5 SYS 4V6'TAB Monitored Smoke Detector 0.0001 0.0350 0.0003 0.1750 1 a 0 0 ca 1 h ' N .1 Korch 1 60-774 8 Zone Expansion Module 0.0380 0.2300 0.0380 0.2300 S F ¢ i; I NFPA 72 2016 29. 5. 1 . 1 Smoke alarms shall be installed: Residence o m g a 4 ESL 26000 Monitored Carbon Monoxide Detector 0.0020 0.0400 0.0080 0.1600 ' ' g g .F 5, 1 . In all sleeping rooms and guest rooms 1 SYS-MEW Interior Siren 0.0000 0.0750 0.0000 0.0750 ¢ .0 .0 H H a " c 0 1 SYS-5603 135 degree fixed heat detector 0.0000 0.0000 0.0000 0.0000 y c m c 2. Outside of each sleeping area within 21 ft of door V. � �, �, o Address: TOTAL: 0.076 1.128 - d H F H z 3. On everylevel , includingbasements. Smoke or Heat Detector X X X X X 4284 Columbine Drive STANDBY Carbon Monoxide Detector X X X X X 4. In living areas of guest suite Vail, Colorado 81657 SUB-TOTAL: 0.08 AMP Ground Fault X X X X 24 HOURS OF STANDBY: 24.00 HOURS Open Circuit X X X X X SUB-TOTAL: 1.83 AMP HOURSLow Battery X X X X X Owner: ALARM: _ AC Power Failure X X X X X N F P A 720 Brad Korch SUB-TOTAL: 1.13 AMP Telephone Line Fault-daily timer test X X X 8. 4. 1 . 1 Carbon monoxide detectors shall be installed: 4284 Columbine Drive Vail, Colorado 81657 15 MINUTES OF ALARM: 0.25 HOURS Panel Silence Feature X X SUB-TOTAL: 0.28 AMP HOURS 1 . Outside each sleeping area in immediate vicinity. General Contractor: TOTALS: 2. On every level Iconic Development TOTAL SUPERVISORY: 1.83 AMP HOURS Nice job. Approved for install. PO Box 1734 3. Other location where required by law, code or standard. Vail, CO 81657 TOTAL ALARM: 0.28 AMP HOURS Ph. 720-428-0691 TOTAL: 2.11 AMP HOURS GC: Steve Sandoval *SPARE OF20% 0.42 AMP HOURS HB1091 Single Family Homes: Carbon monoxide detectors shall MINIMUM BAIL FRY SIZE REQUIRED 2.53 AMP HOURS BAIIERIES SUPPLIED 2 x 7 amp 7.00 AMP HOURS be installed within 15 feet of bedroom door. Code Complience: 2015 International Fire Code 2016 NFPA-72 Nat. Fire Alarm Code BATTERY CALCULATIONS: MAIN ALARM CONTROL PANEL VAI L FIRE INSTALLATION STANDARDS (Rev 4/16)• 2014 NFPA-70 Nat. Electrical Code Detection location and spacing shall be per latest NFPA72 2015 IFC and as set forth : Levels: 3 Levels 1 . Installed in a corridor not more than fifteen feet from Bldg Height: the door of the farthest bedroom 14rf Roof Height 2. Smokes req'd in living rooms, family rooms, home Occupancy Loads: theaters and any rooms that may be used for sleeping. 3. Detectors installed toward middle of room with Occupancy Rating: consideration of bathrooms, ceiling fans and air ducts. Residential - R-3 4 Kitchens and garages are not required to have heat Structure: - CO TH I D FLOOR detection . Type VB/Non-Rated/Non-Sprinkled 5. Storage rooms, closets, unfinished crawl spaces not Sq. Footage: required to have smoke detection . 2,972 SgFt± OOCO CO T SECOND FLOOR Carbon Monoxide detection required per latest NFPA72 and Communication Type: r Colorado HB1091 . In addition : DACT/POTSLines 1 . CO to be instaled no further than 15 feet from furthest Primary Power Location: CC Bell 1 Main Elec Panel- Breaker# ANN - eo FIRST FLOOR bedroom . Submittal Prepared By: GE 2. Within 20 feet of fuel fired appliances, including stoves, Concord 4 gas, fire places, wood burning stoves or wood burning fire r- --..\ FACP SAE PANEL places. I I RISER DIAGRAM 3. Entrance vestibules from attached garages. Phonelines (1) 120 VAC Superior Alarm & Electronics Dedicated 4. Areas with gas fired appliances that pose safety risk. 210 EdwardsVill. Blvd. #A108 12VDC 8 AH Batt Backup PH 970-926-8788 FX 970-926-8790 / System Code e f e r e n c e / brad@superioralarmco.com SYMBOL DESCRIPTION MONITORING API - DENVER COLORADO FACP FIRE ALARM CONTROL PANEL OARM ADDRESSABLE RELAY MODULE REMOTE STATION SMOKE DETECTOR (PHOTOELECTRIC) Ell HORN/SOUNDER SYS# 6101-1759 DESCRIPTION CLASS STYLE TYPE HORN WITH STROBE m135 ROR (TEMP LISTED / )HEAT DETECTOR FIXEDTorr NATIONAL INSTITUTE FOR CERTIFICATION \ IN ENGINEERING TECHNOLOGIES NOTIFICATION APPLIANCE CIRCUIT B Y 4 #18 AWG FPL 15 (NUMBER INDICATES CANDELA) Fire Protection Engineering Technology A significant remodel of an existing single family residence is taking ANN ANNUNCIATOR ^I5 STROBE (NUMBER Fire Alarm Systems lace in the Town of Vail . The residence will not be sprinklered. AC POWER B Y 4 #18 AWG FPL P•� INDICATES CANDELA) p p INITIATING DEVICE CIRCUITS 4 #18 AWG FPL t-�-1 WATER FLOW SWITCH " We will install smoke and carbon monoxide combination devices inEOL END OF LINE RESISTOR t-II-1 VALVE WITH TAMPER SWITCH RE applicable locations and system will be zoned by floor. Our k FIRE DEPARTMENT "KNOX" BOX USE PLENUM RATED WIRE IN ALL PLENUM SPACES OAIM ADDRESSABLE INPUT MODULE Matt Madden installation will meet Town o f Vail Standards and applicable codes. 0MONITORED CARBON MONOXIDE DETECTOR NICET #134111 Level III Scope of Work / C WIRE CHART n 0 SMOKE/CARBON MONOXIDE COMBO DETECTOR Valid Thru 05/01/18 ORIG.6/16/16 SCALE: 1/8"=1'0" LEGEND REV. DATE NOTES: 0 A A FINAL INSP. AS BUILTS: AHJ: Vail Fire Department Mike Vaughan, Fire Marshall Permit #: Index: PAGE NAME: Title/Bldg/Calcs/Map FA-0 Cover Page A 0 AHJ : Vail Fire - Fire Marshal Mike 970-479-2252 SHEET 1 OF 4 J