Loading...
HomeMy WebLinkAboutA17-0009_A17-0009_1487098260.pdf Fire and Emergency Services 2399 N. Frontage Road W. 4► Vail, Colorado 81657 TOWN OF VA l L Tel: 970-479-2252 www.vailgov.com Fire&Emergency Services Fire Marshal FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: Office Use: 1500 Matterhorn Circle Project#: (Number) (Street) (Suite#) Building/Complex Name: Eagle Point Resort Building Permit#: Alarm Permit#: Contractor Information: Lot#: Block# Subdivision: Company: Fire Team Security, Inc. Company Address: 2331 E Road Install Elevator Detailed Scope and Location of Work: City: Grand Junction State: CO Zip:81507 recall modules and Heat detectors at each landing. Contact Name: Richard Rich Elevator lobbies are outdoor/open air. Elevator located Contact Phone: 970-683-8856 between main bldg &bldg with sleeping units. E Mail rich@fireteamsecurity.com (use additional sheet if necessary) Does a Monitored Fire Alarm Exist? Yes E No 4J I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate fire alarm sys- Does a Sprinkler System Exist? Yes(El No(E3 tern drawings and state that all the information as required is cor- rect. I agree to comply with the information and fire alarm system Work Class: drawings,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision New(❑) Addition(❑) Remodel(171) Repair codes,design review approval, National Fire Code, International Retro-Fit([) Other(❑) Building and Residential Codes and other ordinances of the Town applicable thereto. 3Type of Building: Single-Family 4) Duplex C) Multi-Family❑) ' Commercial(0 Restaurant(❑) Other(ED Contractor Signature(required) Property Information Complete Valuation for Fire Alarm Permit: Parcel#: 2103-123-25 Fire Alarm$: 170.00 (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Tenant Name: Eagle Point Condos Date Received: Owner Name: Pointes of Colorado 2014-0916 �IAII ffRf� TOWN OF VAILJ Fire&Emergency Services .MFRoy soN_ g > Fire Department Process For Commercial & Residential Fire Alarm Systems Commercial and Residential Fire Alarm shop drawing requirements at the time of submittal must include the following: X A Colorado Registered Engineer's stamp X Device locations on reflected ceiling plans X Reflected Ceiling Plans (RCP) X Typical device wiring diagrams X Battery calculations X Battery calculations X A list of specific device model numbers X Equipment cut sheets of each type of device X The number of each type of device X Information indicating the specific zones X Circuit diagrams X Point to point wiring diagram X Wiring type, size and number of conductors X The source of AC power circuits X Fire alarm panel locations X Knox Box location X Information indicating monitoring method and monitoring agency This check list has been provided to ensure that our review process may be handled in a timely manner. I have read and understand the above listed submittal requirements: Project/Street Address: 1500 Matterhorn Circle Vail, CO 81657 Contractor Signature: ,/((4' //&71 Date Signed: 419117 2014-0916