Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A17-0009_Specs_1487098260.pdf
Eagle Point Resort Elevator Addition 1500 Matterhorn Circle Vail, CO 81657 Fire Alarm Submittal Manual www.fireteamsecurity.com INC I/ _ ___. ] . . ...._:____,, \,: __ ., :,......., .. v.. ` oviding ou customers with the •est ntegrated Systems Experience Project Eagle Point Resort—Elevator Addition 1500 Matterhorn Circle Vail, CO 81657 Installer/Contractor Fire Team Security, Inc. 2331 E Road Grand Junction, CO 81507 INTELLIKNIGHT FIRE ALARM CONTROL PANEL 4/0 SILENT IntelliKnight° Model 5820XL KNIGHT Addressable Fire by Honeywell Alarm Control System The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling j N line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol iwkhae= • Built in support for 127 SD devices, expandable to 508 SD 7..1%1 h devices using the SD protocol. "J'" • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, • 6 amp power supply and maximum Gentex®, Faraday, System Sensor, and Wheelock® charging l cabinet of c5 amphoursrequired cabinet enclosure is required for • FlexputTM I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a SD clear window, limiting access to the panel while providing • single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure (PN RBB) is required programming.You can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite, which is Windows°- supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an The 5820XL system operates on non digital communicator for remote alarm, trouble or supervisory condition reporting of system activity and system twisted, unshielded cable when wired has been silenced but not yet cleared in compliance with standard wiring programming.The communicator has System Power(Green): Flashes for AC practices as called out in the National the ability to seize two telephone lines failure; solid when power systems are Electric Code 760-51 specifications for to report alarms and troubles to a normal power-limited fire protective signalling monitoring facility. The communicator cables. No special wiring is required. supervises two phone lines and will 5820XLprovides 13preset notification activate a trouble signal if a line failure System Application is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns (including ANSI 3.41) Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails, two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used. Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing. The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally, the IntelliKnight system Contact ID. The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- multiple device types, including: account number. programming. Its innovative, dead-front • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. • W..Q- detector �;;`;� User Interface - - • Addressable heat sensor 'The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and large easy-to-use tactile touch ad can be or. !b- • Contact module Y- p • Relay output module used for system operation, Q V programming and maintenance. It has iv q+ m • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector(SK system trouble, system silenced and protocol only) system power. System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory.The NFPA 72: Central Station; Remote • Addressable multi modules (SK system's non-volatile event history protocol only) buffer stores 1000 events for viewing Signalling; Local Protective Signalling from the built-in or remote annunciator. Systems;Auxiliary Protected Premises The following advanced sensor Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, a mechanical firefighter's key or a valid manual, waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. supervisory(DACT non-coded) • Maintenance alert Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements programming. The JumpStart®feature MEA 429-92-E Vol. VI; FM Approved minimizes programming INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL W°dFaBased cillity Addressable Fire Alarm System Management Software SK(System Sensor) Protocol Devices U Mndows Based Up/Down load Software - 0R ® Compatible CS r al■e■ .- -t T : Receiver [ -—"\� Automation 0.FR 5 • wpm Internet 5820XL SK-212UD Connection VisorAlarm IP Communicator 5895XL Ir.li9 --„,—rldredule 3 Form C Relays 4 3 Form C 120ays 4 ' ' Event Printer Ce _ Parallel ■ 5815XL .3 R5-C3t 1-1A SLC Recorder_ _ 5860 5824 Remote Annunciator PrinterlGatenar Module r',va” (211nits MatdSystem) � . -? F 6 Flexput- _ I/O Circuits 815XL rscan be inputs CLO Expander or outputs rn — 6 Flexput'- LT W Grunts F can be inputs r' ' or outputs 1111) ril W. u eells.sonoes.E ns,ana NAca W. 0 Pall smarts canVeln ui so nea strut.oe@[to'S 1 .1/ la SK-Ion SK-Monitor SK-Iso SK-Control-6 SR-Control B200SR SK-Acclimate SK-Zone-6 V Addressable Addessable Fault Isolator Addressable Supervised Sounder Mubicntena Zone loazdion Monitor Module Nonlcation Control B.0 smoke Interface 5860 Detector Module module Module detector Module Remote Annunciator I SK-Photo SK-Monitor-2 SK-Relaymon-2 SK-Heat B224RB 622401 B210LP 5880 6K-Photo-T Dual Mon rtor Addressable SK-Heat-BOR Relay solani ereerm Addressable Module Duel Monitor SK-H eat-HT Bose Bare BoreLED Driver Fnotoeloetnc RAT Relays Addressable Input Module Detector Heat detectors 41lit l* '11' ''' . . . I I I I Relay Interfrfae Modile SK-Beam SK-Mon-10 SK-Pull-DA SK-Duct SK-Ninimon SK-Relay-6 SK-Zone SK-Relay SKBeam-T Adutesseble SK-Pull-6A Adctessable Monitor Relay Conn! Adcressable Adrtesseble Addressable Monitor Addressable Duct Module Module Interface Relay Beam Ceteeter Module Pull Station Daector Module Module 5865-4 or 5865-3 I Use the 5380 to control up to 4 , (5865-4�c � 1 5883 Relay Interface Modules INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/lO Module 16"W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"DFeatures 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder. The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status Type of Jack: RJ31X (two required) reports, and event history. Interfaces with building control system. This document is not intended to be used for installation purposes.We try to keep our SILENT Made in America 44 KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. IntelliKnight&Jumpstart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSORY SILENT Model SD500-ARM KNIGHT Addressable Relay Module by Honeywell Place relay applications anywhere on the IntelliKnight loop with the SD500-ARM Addressable Relay Module. The SD500-ARM is an addressable device that adds great flexibility to the IntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp © 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other IntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire protection needs. Model SD500-ARM Features Addressable Relay • Two sets of Form C contacts. Module • Contacts are rated at 2A @ 30 The SD500-ARM provides two VDC or .6A @ 120 VAC. Ea= o ° m Form C contacts rated at 2A @ 30 • Up to 127 relays can be used on n o x► VDC or .6A @ 120 VAC. These each SLC loop. 0 contacts can be used for virtually • Relay programming is O O any normally open or normally completely flexible—can be closed application. mapped to zone conditions. Model SD500-ARM • Polling LED visible through Listings cover plate. Operation • UL listed, complies with Specifications NFPA 72. Each relay module is programmed p with a unique SLC loop address. • CSFM approved When an event that controls the Contact Rating: Form C • MEA Approved, 429-92-E, relay module occurs, the relay is 2A @ 30 VDC Vol. 9 triggered by the IntelliKnight panel. .6A @ 120 VAC • FM approved Standby Current: .55 mA Alarm Current: .55 mA Compatible Control Panels Ambient 32°F to 120°F • Temperature: (0°C to 49°C) 5820XL • 5820XL-EVS Mounting: 4-square electrical box • 5808 • 5700 INTELLIKNIGHT ACCESSORY Model SD500-ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's Intelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW AN 0 0 0 CAUTION REMOVE POWER PRIOR TO SERVICING IM o KA 1071 O ini :ICc1 moon 1:11 O o IC0+7I SILENT.KNIGHT l IC71 0 y II- N N--N 4-7/8" 1/4" 14-04 1" Model SD500-ARM Addressable Relay Module Dimensions it SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to odtinformation deWcannot all specifickeepur applicationsproucinforranticipate up-to-all requirements.ateandaccuratAll.specifications cover are FORM#350218 Rev. E subject to change without notice. For more information, contact Silent ©2013 Honeywell International Inc. by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610. y Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT SD500-AIM & SD500-M I M KNIGHT Addressable Input Modules by Honeywell IntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • DIP switch programmable for fast The SD500-AIM and SD500-MIM are installation addressable input modules for use with • Up to 2500 ft wiring distance from j I the Intelliknight fire alarm control either input module to contact panels (FACPs). The SD500-AIM • Use up to 14 gauge wire J I; addressable input module mounts to a • UL listed ® I I 4"-square box. The SD500-MIM mini i= IBI input module fits inside a single gang Electrical Specifications t3, I12Iyism box. Both input modules are designed Standby Current: 0.55 mA to be used with pull stations, water flow I Alarm Current: 23 mA max for one �� switches, and other applications device; 46 mA max for two devices; SD500-AIM requiring dry contact alarm initiation 0.55 mA for each additional device devices. Line Resistance: 502 max These modules are supervised, single input contact monitors. Using an EOL Mechanical Specifications resistor, they monitor for alarm contact SD500-AIM Physical Description closures and for open circuit wiring Dimensions: fault conditions. If a fault occurs in the 4.9"W x 4.9" H x 1" D wiring, the module alerts the FACP. (12.4 W x 12.4 H x 2.5 D cm) SD500-MIM Each addressable input module is Weight: 3.6 oz (120.1 g) programmed with a unique signal line Color: Ivory cover plate circuit (SLC) loop address. SD500-MIM Physical Description Approvals Features Dimensions: 1.5"Wx2.5" Hx0.7" D NFPA71 & NFPA72 • Single contact monitorUL 864 • SD500-AIM supports Class A(Style (3.8 W x 6.4 H x 1.8 D cm) CSFM 7300-0559: 132 D)or Class B (Style B)contact Weight: 1.6 oz (45.4 g) MEA 429-92-E Vol. IX monitor wiring Environmental FM Approved for use with the 5820XL • SD500-MIM support for Class B Operating Temperature: (Style B)contact monitor wiring 32°F— 120°F (0°C—49°C) • Attractive ivory cover plate with the SD500-AIM Humidity: • Small and lightweight size allows for 10%—93% non-condensing flexible mounting options with the S D500-M I M INTELLIKNIGHT ACCESSORY SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate 10/ I',, 1....--111111 SLC St IN ■ SLC o uc IN 7c celiac!being monitored .d�w� .d%:; ii r: Glc • p ULLlsted��. 628 EOL , s . _ .... __, . tiii_. _0.. i C° All Wring is Supervised O � Power Limped �Q d o . ,,,A To contact + being monitored'V LL Listed ' ' _,., r 7E6018_ - 9 7 H + -. 1 0 hci Compatible FACPs Ordering Information 5820XL SD500-AIM Input Module 5820XL-EVS Addressable input module with ivory cover plate. 5808 5700 SD500-MIM Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA ctipkeep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350231 Rev. F subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc by Honeywell 12 Clintonville Road, Northford, CT 06472-1610.Phone: (800)328-0103 Fax: (763)493-6475 For Technical Support, Please call 800-446-6444. .www.silentknight.com SYSTEM �$ SENSOR • _F pee ?+' Multi-Voltage • �F', so Conventional Relays s 'AN r System Sensor's multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control,door control, air handling unit controls,and other types of system interfacing. Features The R-10T,R-20T,R-14T,and the R-24T models are multi- Multi-voltage operation voltage relays with terminal strip field wiring connections,mounting • track,and hardware.The R-10T is a single FORM—C(SPDT)relay with •Activation LEDs a red activation LED,and the R-14T is a four-gang 1 FORM—C(SPDT) •Easy and flexible installation relay with four red activation LEDs.The R-20T is a single 2 FORM—C •Reliable and robust design (DPDT)relay with a red activation LED,and the R-24T is a four-gang 2 FORM—C(DPDT)relay with four red activation LEDs. •Multipurpose field installations •Multi-voltage relays with terminal strip field wiring connections, The R-10E/R-20E and R-14E/R-24E are similar to the T-series mounting track,and hardware for R-10T/20T and R-14T/24T track mount relays,but they are mounted into a steel enclosure.The •Removable front cover on steel enclosure for R-10E/R-20E and R- enclosure has a removable front cover that provides easy access and 14/R-24E,which mount inside the enclosure an LED viewing hole on the top of the cover. •LED viewing hole on top of the steel enclosure's cover PR-1/PR-2/PR-3 are epoxy encapsulated multi-voltage relays.They •Extra pair of wires for redundant power input on PR-3 are single-pole double-throw relays that use a red LED as a visible •Terminal strip field wiring connections,mounting track,and indication of relay coil energization.PR—3 is hardware identical to PR-2,except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated,single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems,e.g.to supervise power supplies. Agency Listings MEA approved LISTED Multi-Voltage Conventional Relay Specifications Specifications:R-10T/R-14T/R-20T/R-24T Specifications:PR-1 Operating Voltage 18-35 VDC,18-35 VAC,115 VAC,230 VAC Operating Voltage 18-35 VDC,18-35 VAC,120 VAC Operating Current 20 mA DC max.@ 24 VDC,24 VAC,115 VAC, Operating Current 15 mA DC max.@ 24 VDC,24 VAC,120 VAC 230 VAC(R-10T/R-14T) Operating Temperature -40°F to 158°F(-40°C to 70°C) 40 mA DC max.@ 24 VDC,24 VAC,115 VAC, Humidity Range 10 93%RH 230 VAC(R-20T/R-24T) Wire Length 8-minimum Operating Temperature -40°F to 158°F(-40°C to 70°C) Dimensions 0.87"H x 2.01'W x 1.42"D Humidity Range 10%-93%non-condensing Contact Ratings 24 VDC:7 A with UR=5 mS Dimensions R-10T/R-20T:2.51.x 3.35'W x 1.2"H 120 VAC:7 A max.(0.35 PF) R-14T/R-241:10"L x 3.35'W x 1.2"H 250 VAC:10 A resistive Contact Ratings 24 VDC:7 A with VR=5 mS 30 VDC:10 A resistive 120 VAC:10 A Specifications:PR-2/PR-3 120 VAC:1/6 HP 230 VAC:7 A Operating Voltage 10 to 40 VDC Specifications:R-10E/R-14E/R-20E/R-24E Operating Current 30 mA DC max. Operating Voltage 18-35 VDC,18-35 VAC,115 VAC,230 VAC Operating Temperature 40°F to 158°F(-40°C to 70°C) Operating Current 20 mA DC max.@ 24 VDC,24 VAC,115 VAC, Humidity Range 10 93%RH 230 VAC(R-10E/R-14E) Wire Length 8-minimum 40 mA DC max.@ 24 VDC,24 VAC,115 VAC, Dimensions 0.91"H x 1.65'W x 1.22"D 230 VAC(R-20E/R-24E) Contact Ratings 120 VAC:10 A max.(resistive load) Operating Temperature -40°F to 158°F(-40°C to 70°C) 120 VAC:7 A max.(0.35 PF) Humidity Range 10%-93%non-condensing 250 VAC:10 A max.(resistive load) Dimensions R-10E/R-20E:5.11 x 3.75'W x 2.5"H 30 VDC:10 A max.(resistive load) R-14E/R-24E:11"L x 5.3'W x 2.5"H Specifications:EOLR-1 Contact Ratings 24 VDC:7 A with UR=5 mS Operating Voltage 9 to 40 VDC 120 VAC:10 A Operating Current 20 mA DC max. 120 VAC:1/6 HP Operating Temperature -22°F to 140°F(-30°C to 60°C) 230 VAC:7 A Humidity Range 10-93%RH Wire Length 8"minimum Contact Ratings 120 VAC:0.5 A max.(resistive load) 30 VDC:3 A max.(resistive load) 0 • ilia . ' PR-1 EOLR-1 PR-3 R-10E&R-20E Enclosure U 3 -litr % . •ice-.Jfmo... PR-2 R-10T R-14T R-14E&R-24E Enclosure $T SYSTEM ®2007 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Visit systemsensor.com for �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0372-005.3/07•#1782 SYSTEM �$ SENSOR (011111 . -\\ 5600 Series Mechanical • . . Heat Detectors \r--- 4 System Sensor's 5600 series mechanical heat detectors i offer a low-cost means for property protection against fire,and for non-life-safety installations where smoke �I detectors are inappropriate. ' Features Multiple configurations.The 5600 series offers a full-line of •Multiple configurations for installations: configurations to accommodate a broad range of applications.Both -Single and dual circuit models single-and dual-circuit models are available for low-and high- -Fixed temp and combination fixed temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. •Plain housing for residential installations(Model 5601 P) •Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, •Abroad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back -Single gang boxes.And these models accommodate four-square back boxes, -3.5"and 4"Octagonal when used with a square to round plaster ring.The reversible -4"square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. •Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings 13 ® MEA LISTED APPROVED approved S2101 3016008 199-03-6 7270-1209227 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90°C),and shall activate by means of a fixed temperature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature,approximately 15°F(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601 P,5603,5621,and 5623:100°F(38°C) 5602,5604,5622,and 5624:150°F(65.6°C) Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601 P,5603,5621,and 5623:135°F(57°C) 5602,5604,5622,and 5624:194°F(90°C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 15°F(8.3°C)rise per minute(models 5601P,5602,5621,and 5622 only) Mounting 31/-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact Ratings 6-125VAC/3A 6-28VDC/1 A 125VDC/0.3A 250VDC/0.1 A Input Terminals 14-22 AWG aonik x.1aowxi— '''''s0 11 ----'—''' o o 0 0 ) , 1,.. „,„.,,,,,,‘ ., /.///.. .\\,„ I , . . . . ,,,,,__ _ ____ ---- Iiia Y 3 fit taiklY i 5601P 5602,5622 5603,5623 5604,5624 5621 Ordering Information Identification Method Temperature Model Circuit on Exterior Rating Activation UL Protected Spacing-10 Foot Ceiling* 5601 P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. *Th_ SYSTEM m2006 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Usit systemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0351-002.11/06•#1676