Loading...
HomeMy WebLinkAboutA17-0015_FA000_1491940500.pdf lilei OF go, z ec FRYrtbq X40.) /145- F' .1 a� r LEGE\ e� : '6 ��.� 04/11/17 Vail Fire&Emergency Services SYMBOL DEVICE MANUFACTURER PART MOUNTING 1cy`� li ' fi. / !011 35233) v REI ERS RESIDENCE FACP Honeywell Vista-128BPT "1'' 'r0 , 4= ir` Ade co Vista 128 FACP Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox . , .,: Standby Number of Current Total Current LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox Device Type Devices (Amps) (Amps) Main FACP CPU 1 X 0.032 = 0.032 Combination Smoke & 4193SN Serial Interface 13 X 0.00015 = 0.00045 0Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box COSMOD4W Module 3 X 0.052 = 0.156 i3 Smoke Detector 5 X 0.0005 = 0.0025 Combination Smoke and i4 Smoke/CO Detector 7 X 0.0005 = 0.0035 -co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box 6160 Keypad 2 X 0.04 = 0.08 SUM COLUMN FOR STANDBY LOAD 0.27445 � = AMPS ® P _ System Sensor 5601 Heat Detector w/4193SN Addressable module 4" square box Alarm Load _ Number of Current Total Current Device Type Devices (Amps) (Amps) E Cosmo Interface Module COSMOD4W Main FACP CPU 1 X 0.032 = 0.032 4193SN Serial Interface 3 X 0.00015 = 0.00045 COSMOD4W Module 3 X 0.075 = 0.225 KB Knox Box i3 Smoke Detector 5 X 0.035 = 0.175 i4 Smoke/CO Detector 7 X 0.04 = 0.28 6160 Keypad 2 X 0.1 = 0.2 ,O, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox z Outside Horn/Strobe 1 X 0.195 = 0.195 0 SUM COLUMN FOR ALARM LOAD 1.10745 = AMPS o_ Standby Load Required Standby Time in Hours GENERAL NOTES: E Current (Amps) Lu 0.27445 X 24 = 6.59 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN z Alarm Load Required Alarm Time in Hours ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE 0 Current (Amps) (15 MINUTES) DEPARTMENT REQUIREMENTS AND NFPA 72. Lu 1.10745 X 0.25 = 0.28 2. REFER TO MANUFACTURERS DATA SHEETS ANDcc Add Standby and Alarm Load for Required Ampere Hour Battery 6.86 INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION Multiply by the Derating Factor of 1.2 REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Total Ampere Hours Required = 8.24 PROGRAMMING AND DEVICE OPERATION. w Batteries Provided: 12AH Minimum H 0 ZONE LIST O z ZONE # DESCRIPTION o 1 SPRINKLER WATERFLOW CO 2 SPRINKLER TAMPER (70 3 LOWER LEVEL CO DETECTION o 4 LOWER LEVEL SMOKE DETECTION cc 5 MAIN LEVEL CO DETECTION (1) 0) 0 6 MAIN LEVEL SMOKE DETECTION .E J O co 7 UPPER LEVEL CO DETECTION J U o 8 UPPER LEVEL SMOKE DETECTION SEQUENCE O F z Lu 07; z Q 9 GARAGE HEAT DETECTOR 0 a O v 10 SYSTEM TROUBLE O P E SAT I O N S: w z o c>- z - o o �� '' a - 0 J C.� - O - Z M O y CD (n w N Q (n Q al Q O _ LI7 CO (6 0 Z (n I- > 1- Ji- el t 0 X a O O C L� m (n Z E W 2 CO ao cn 0 M to U 1 2 S- 2 22 z i- < (n E i- . I- m (� P) d Oi Lai m 0 1_ I- 1_ I- 1_ I- U CC O Q DEVICE Q Q D V) N Z z a o Q�WV) CC a z � z -e z � DESCRIPTION Q a CLO CLO CLO 0 0 0 X00! 1 I- I- I- I- I- I- SMOKE DETECTOR X X X F- O z - - - 0 HEAT DETECTOR X X X ti pp A roved as noted . Fix title block and CARBON MONOXIDE DETECTOR X X X identify clouded area . SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X OO CO O POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X 1- C:3, - O O PROJECT \ EOFVAT O \ : o o w IRC? El V ESS SES DE \ CE < 3090 BOOTH CREEK I . VAIL COLOADO o v c LU ALAV SYSTEV v z z D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) Q X = 2-WIRE DATA, 2-#1 6AWG EOL EOL AHJ: VAIL FIRE & EMERGENCY SERVICES J eL Z O 2 APPLICABLE CODES: 2015 hFBC, 2015 IFC, 2013 NFPA 72 < U N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG _ Z = 2-WIRE DATA CIRCUIT, 2-#16AWG D D FULLY SPRINKLERED J Q KP = KEYPAD CIRCUITING, 4-#18AWG FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM INCLUDES NEW W 0 W 0 ©o co ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE U �J CO RISER NOTES: � CO DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE Z w = UJ 1 . REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE LJJ 0 W I 121 MORE INFORMATION. PROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. HEAT DETE ORS 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS L N LN MANUFACTURERS SPECIFICATIONS. D , [El WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO C 0 Ct 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (TYP) (TYP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE LJJ = O CO PRIOR TO INSTALLATION. WIRING DIAGRAM IS O HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM U INCLUDED SUBMITTAL BOOKS. SYSTEM. . 120VAC DEDICATED POWER VISTA 128FPB Z O CL z CONTROL PANELZ FLOW SWITCH O ZCO i_ �_ TELEPHONE LINE - FIRE TAMPER SWITCH rn W O w TELEPHONE LINE - SECURITY nWP FIRE PROTECTION ENGINEER: o io OUTPUT ELL N ,O, EOLR DEBORAH SHANER, P.E. SHANER LIFE SAFETY No longer required M U DATA/COM KP I I I PO BOX 1073, FRISCO,ISCO, CO 80443 1per VFES standards. SHEET DESCRIPTION: ISE� AG SAV OUTPUT KEYPAD KEYPAD PHONE: 970-409-9082 Owner option. FIRE ALARM PLAN FAX: 970-797- 1898 DRAWN BY: DATE: DLS 3/28/17 SHEET#: FA-0.00