Loading...
HomeMy WebLinkAboutB14-0224_A1-1_1415134560.pdf 4 F pot ■ 44 illiorios m BUILDING CODE DATA BUILDING CODE DATA 3. MEANS OF EGRESS Gorsuch - Vail Village Store Gorsuch - Vail Village Store � 3.1 Occupant Load/Exit Width per Occupied Area (Tables 1004.1.1 & 1005.1) /A\ Vail, Colorado Vail, Colorado Occupied Floor Occupant Exits I)wia 0) leall Location Occupancy Use Area OL Factor Load Reqd. 1. BUILDING DESCRIPTION Applicable Codes Lower Level M Retail sales 5,670 30 189 2 Code Edition 11/04/14 Lower Level A2 Resturant 595 15 40 1 1.1 Actual Building Area Building IBC 2012 Including Appendices: B, C, E, G, J and K Fire IFC 2012 Including Appendices: A, B, C, D, E, G, H, J Lower Level A2 Kitchen 188 200 1 1 Gross Floor Street Level M Retail sales 6,293 30 210 2 Description Occupancy Area Mechanical IMC 2012 Street Level A2 Resturant 850 15 57 2 Lower Level M, A2 7,750 S.F. Plumbing IPC 2012 r 1 L 1 V L Street Level A2 Kitchen 102 200 1 1 Street Level M, A2 - 7,787 S.F. Fuel Gas Code IFGC 2012 + FRYE Upper Level M,B 7,812 S.F. Energy IECC 2012 Upper Level M Retail sales 5,824 60 97 2 - Electrical NEC 2011 Upper Level B Office 1,268 100 13 1 Clock Tower Level 3 B 352 S.F. - pp Abatement Code UCADB 1997 Loft Office B Office 423 100 5 1 Clock Tower Level 4 B 352 S.F. Accessibility ICC/ANSI A117.1-2003 2003 ARCHITECTS Tower Level 1 B Office 270 100 3 1 Clock Tower Level 5 B 352 S.F. 3 Tower Level 2 B Office 270 100 3 1 East Loft Office Space B 432 S.F. Local Amendments Town Code of the Town of Vail Tower Level 3 B Office 270 100 3 1 Total Gross Building Area: 24,837 S.F. San Francisco Office Total Occupant Load 622 Building Classification Tel: 415.392.4433 1.2 Building Height Type 5-A Type of Construction Type 5-A Truckee Office 3.2 Number of Exits per Floor Section 1005.1 Occupancy Classification M w/ non-seperated uses B & Si Section 508.3 Min. Stair Maximum Allowed Actual Tel: 530.214.0899 Automatic Fire Sprinklers Yes Section 903.2 Min. Required Clear Width Width M B A2 M B A2 Mixed Occupancy Yes Non-seperated Vail Office inches (inches) Stories: 3 3 2 3 3 2 Per Door (inches) Height: 50' 34' MAX. Seismic Design Category Zone D Tel: 970.949.0899 Floor Occupant Load Exits Required Exits Provided Reqd. Prov. Reqd. Prov. Basic wind speed 90 mph _ www.PierceFrye.com Lower Level 231 2 5 32.0 32+ 19.3 36 min Snow Load 145 psf info@PierceFrye.com Street Level 267 2 5 32.0 32+ 23.5 36 min 2. BUILDING REVIEW Longitude: 106°22'24.95"W _ Upper Level 124 2 3 32.0 32+ 10.3 36 min Latitude: 39°38'27.44"N 2.1 Allowable Floor Area Calculations Table 503 & Sections as noted Occupancy Group: B A2 Project Information Tabular Area (At from Table503) 14,000 18,000 11,500 3.3 Miscellaneous Requirements Maximum Dead End: 20' (50'with sprinklers in B & M Occupancies) Company Name Contact Phone # Door Swing Direction: In direction of travel where occupant load is 50 or more. Architect Pierce Frye Architects Tom Frye 970-949-0899i 70 949 0899 Exit sign Illumination: Yes Structural Engineer Monroe Newell Engineers Hennes Spaeh 970.949-7768 Exit access travel distance: 200' Max without sprinklers 1016.2 Mechanical Engineer Rader Engineering Drew Rader 970-845-7910 P Allowable Area Per Floor(Aa per Equation 5 1) 14,000 Electrical Engineer Rader Engineering Drew Rader 970-845-7910 Fire Alarm System Requirements: Manual alarm system & smoke alarms Allowable Stories (506.4) (Max. 3) 3 3 2 Contractor Aspen Constructors Wally Sheata 970.331.9043 Maximum Building Area * N Bathroom Fixture Count Table 2902.1 - 6. Mercantile *Note: Area increase not required to meet tabular areas. Water closets required per table 2901.1 = 1/500 Male 1/500 Female Total buildingoccupant load = 564 = 282 Male 282 Femaleper 2902.1.1 s 00 p 2.2 Occupancy Areas- Non-seperated use-section 508.3 0 Water closets required = 1 Male accessible, 1 Female accessible �� = L-0 u Water Closets existing = 6 (non-accessible) Description Occupancies M B A2 ; U +-r Water closets proposed = 1 Male (accessible) 1 Female (accessible) Lower Level - Retail sales, Resturant M, A2 5,670 0 783 � .� 1 unisex (accessible) 4 unisex ( existing non-accessible) Street Level - Retail sales, Resturant M, A2 6,293 0 952 Note: no existing bathrooms are located on an accessible route and do not meet accessible standards. Upper Level - Retail sales, offices M, B 5,824 1,268 0 j Loft Office B 0 423 0 /1 04) Q Tower Level 1 Office B 0 270 0 �,/ J AFixture count ao'o'eol Tower Level 2 Office B 0 270 0 Tower Level 3 Office B 0 270 0 \ U 0 Total Occupied Building Area: 17,787 2,501 1,735 (31 '- V rt 2.3 Building Fire-Resistance ' n Type of Construction: Type 5-A > w Table 601 rn Fire-Resistive N Building Element Rating Primary Structural Frame 1 Exterior Bearing Wall 1 Interior Bearing Wall 1 Interior Non-bearing Walls & Partitions 0 Floor Construction & Secondary Members 1 Roof Construction & Secondary Members 1 Shaft Enclosures connecting <4 stories 1 1 Section 708.4 2.4 Exterior Wall Protection Issue Date: Table 602 Type 5-A 06/16/2014 Building Permit Wall Location Distance to Property Line Exterior Wall A07/10/2014 Building Permit Resubmit North 0' 2 hr ® 10/03/2014 Building Permit Revision East Greater than 5'to 30'to P.L. 1 hr South Less than 5'to P.L. 2 hr West Greater than 5'to 30'to P.L. 1 hr 2.5 Maximum Area of Exterior Wall Openings Table 705.8, Protected Openings Degree of Allowable Area Opening of Wall Location Fire Separation Distance Protection Opening/Level North 0'to <3' UP, S Not permitted Existing openings to remain East 10'to < 15' UP, S 45% Existing openings to remain South 10'to < 15' UP, S 45% Existing openings to remain West 10'to < 15' UP, S 45% Existing openings to remain CO , k ;.' E S. 0 -X v iERCE !‘ o. 401494 fe‹. .Drawing Title: CODE DATA INFORMATION Date: February 14, 2014 Project No: 23394.00 Drawn by: STAFF CODE DATA Checked by: AP/TF 0 N.T.S. Sheet: A 1 1 • ©2014/2015 PIERCE FRYE ARCHITECTS