HomeMy WebLinkAboutB14-0224_E1.0_1415134560.pdf 041'14 OF le 4:4Apliee r La*7) : z id cc m . SYSTEMS DISTRIBUTION AND RAtGEWAY L I C HTI NC FIXTURES ABBREVI ATI ONS AND SYMBOLS ELEGTRI GAEL C ENERAL NOTES ....- .1q031° A AMPERES) I. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE AND 22. ALL NEW CIRCUITS SHALL HAVE A GROUND HIRE INSTALLED. TTB, MDF OR IDF SYSTEM BACKBOARD MDG MAIN DISTRIBUTION CENTER (MDG) A LUMINAIRE TYPE, REFERENCING LUMINAIRE FUNCTIONING ELECTRICAL SYSTEM. 11/04/14 a SCHEDULE, TYPIGAL ALL FIXTURES. AG ABOVE COUNTER 23. ALL WIRING NOT INSTALLED IN CONDUIT AND INSTALLED IN THE CEILING SPACE SHALL BE PLENUM RATED. 0 TELECOMMUNICATION OUTLET SURFACE MTD PANELBOARD SUBSCRIPT, IF SHOWN, REFERENCES WALL AFF ABOVE FINISHED FLOOR 2. MATERIALS AND INSTALLATION SHALL COMPLY WITH GODES, LAWS AND ORDINANCES OF FEDERAL,STATE SWITCH. AND LOCAL GOVERNING BODIES HAVING JURISDICTION. 24. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TO It FLOOR MOUNTED TELECOMMUNICATION OUTLET RECESSED PANELBOARD AFG ABOVE FINISHED GRADE ENCLOSE RECEPTACLES. I ,,, 5�iih;l ;,;;r'I y 3. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L.,ETL,GSA OR ANOTHER 1 �- I'li U T IQ WALL MOUNTED LUMINAIRE RECOGNIZED TESTING LAB. 25. EACH SWITCH,LIGHT,RECEPTACLE AND OTHER MISCELLANEOUS DEVICE SHALL BE PROVIDED WITH A I rFrj TELEVISION OUTLET AHJ AUTHORITY HAVING JURISDICTION py TRANSFORMER GALVANIZED OR PRESSED STEEL OUTLET BOX OF THE KNOCKOUT TYPE,OF NOT LESS THAN NO. 14 U.S. „ SURFACE MOUNTED LUMINAIRE AIG AMPERES INTERRUPTING CAPACITY 4. ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR,EQUIPMENT AND GAUGE STEEL. CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND BUSHINGS AND ALL UNUSED 1 .I *WA Q SPEAKER - PAGING AND OR SOUND SYSTEM -►►► BRANCH CIRCUIT HOMERUN MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE BUILDING STANDARDS,EXCEPT AS NOTED KNOCKOUTS MUST BE LEFT SEALED. THERE MUST BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS AND Ox (x) - INDICATES SPEAKER ZONE 1 I RECESSED LUMINAIRE ATS AUTOMATIC TRANSFER SNITCH OTHERWISE. DEEP BOXES SHALL BE INSTALLED WHERE REQUIRED. BOXES SHALL BE SECURELY AND ADEQUATELY ---_ CONDUIT CONGEALED IN FLOOR OR I I SUPPORTED. BFF BELOW FINISHED FLOOR 5. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS,GOVERNMENTAL FEES,TAXES AND rrrrr••U••• MICROPHONE OUTLETUNDERGROUND 0 DOWNLIGHT LUMINAIRE .••� '•.. O LICENSES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE ELECTRICAL WORK. 26. WHERE FLOOR FITTINGS REQUIRE PENETRATION OF THE FLOOR SLAB,THEY SHALL BE STANDARD DEVICE �0 '� R•(�/ •• G CONDUIT LISTED BY UL FOR THE PURPOSE AND HAVE A UL FIRE RATING EQUAL TO THE FLOOR RATING. FLOOR , ' ► .....611%.0 O VOLUME CONTROL CONDUIT EXPOSED OR CONGEALED IN HALL ❑ SURFACE CEILING LUMINAIRE b. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITY COMPANIES SERVICE BOXES SHALL BE MODULAR,ADJUSTABLE FLUSH TYPE,DUAL SERVICE UNITS SUITABLE FOR WIRING •• CATV GABLE TELEVISION SHOP DRAWINGS, WHICH ARE REQUIRED BY THESE AGENCIES, FOR THEIR APPROVAL. METHOD USED. COMPARTMENT BARRIERS SHALL SEPARATE POWER FROM LOW VOLTAGE CABLING. •� OR CEILING �,'� 0 PUSH BUTTON • PENDANT LUMINAIRE PROVIDE RECTANGULAR SERVICE PLATE WITH SATIN FINISH. • �� �� 1 ((� CB CIRCUIT BREAKER 1. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF ANY MATERIALS OR APPARATUS 7 ©, o RACEWAY UPBELIEVED TO BE INADEQUATE,UNSUITABLE, IN VIOLATION OF LAWS,ORDINANCES,RULES OR REGULATIONS 2q. ALL RECEPTACLES SHALL BE SPECIFICATION GRADE NEMA 5-2OR,UNLESS OTHERWISE NOTED. 1 58 7 z; • 0a CLOSED CIRCUIT TELEVISION CAMERA (> WALLWASH LUMINAIRE CT CURRENT TRANSFORMER OF AUTHORITIES HAVING JURISDICTION. A-a . i ; ce; • RACEWAY DOWN 30. ALL LIGHT SWITCHES SHALL BE SPECIFICATION GRADE,QUIET OPERATION RATED 120/277 VOLT,20 AMPS, DISC DISCONNECT 6)AL `� <C/S GABLE TRAY (LENGTH AS INDICATED ON 1--� 1 STRIP LUMINAIRE 6. FOR ALL JOBS THAT INCLUDE DEMOLITION WORK BY THE ELECTRICAL CONTRACTOR, DURING AND AFTER UNLESS OTHERWISE NOTED. e• DRAWINGS) -3 GAPPED CONDUIT DW DISHWASHER DEMOLITION,EC SHALL MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING DEVICES THAT ARE TO REMAIN. EG .� S ''•,.....••' ��j.rre iV 0 VI SURFACE OR PENDANT TRACK LUMINAIRE SHALL REMOVE,RELOCATE, AND/OR REWORK ANY CONDUIT AND WIRING TO FACILITATE THE NEW 31. ALL FACE PLATE AND DEVICE COLORS SHALL BE APPROVED BY ARCHITECT OR OWNER/LEASEE. ••�S�ONA1-E rrrr 3 CURRENT TRANSFORMER DHS(5) DRAHING(S) CONSTRUCTION SCOPE OF WORK. FOR A LUMINAIRES THAT ARE EXISTING TO REMAIN OR EXISTING TO BE •i••••e�r�rrr- LINEAR PENDANT LUMINAIRE (LENGTH AS RELOCATED, EG SHALL GLEAN LENSES AND REPLACE ALL EXTINGUISHED LAMPS,UON. 32. PROVIDE LUMINAIRES SHOWN AS SHADED WITH EMERGENCY BATTERY BALLASTS. EMERGENCY LUMINAIRES �� �� (E) EXISTING TO REMAIN SHALL SENSE UNSWITCHED POWER TO THE SPACE AND OPERATED AUTOMATICALLY UPON LOSS OF NORMAL e- CIRCUIT BREAKER SWITCH INDICATED ON DRAWINGS/SCHEDULE) q. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS,VISIT THE SITE,AND POWER. ALL SHADED LUMINAIRES WITH 2' AND 4' LAMPS OR LONG BIAX LAMPS SHALL HAVE ONE (I) qo EG ELECTRICAL CONTRACTOR THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS AND LOCAL CONDITIONS RELATING TO MINUTE, TWO LAMP, 1400 LUMEN EMERGENCY BALLAST. ALL SHADED LUMINAIRES WITH COMPACT •-\0-1 FUSED SNITCH EXIT LUMINAIRE - SHADED INDIGATES THE WORK. FAILURE TO DO SO HILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE FLUORESCENT LAMPS SHALL HAVE A FACTORY INSTALLED q0 MINUTE EMERGENCY BALLAST. ALL ®1 FACE/ DIRECTIONAL ARROWS AS SHOWN. EF EXHAUST FAN CONTRACT. EMERGENCY LUMINAIRES SHALL HAVE REMOTE TEST SWITCHES AND VISIBLE INDICATING LIGHTS. CONNECT GROUNDING ELECTRODE CONDUCTOR THE EMERGENCY BATTERY BALLAST TO THE UN-SWITCHED LEG OF THE LIGHTING CIRCUIT INDICATED. II H10. ALL MATERIALS,AND EQUIPMENT SHALL BE ERECTED, INSTALLED,CONNECTED,CLEANED,ADJUSTED, BATTERY PACK EMERGENCY LUMINAIRE (ER) EXISTING TO BE RELOCATED TESTED,CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE MANUFACTURERS DIRECTIONS 33. ALL BATTERY BACKUP EMERGENCY LIGHTING AND EXIT LIGHTS SHALL BE HIRED AHEAD OF ANY LOCAL [--] METER EM EMERGENCY AND RECOMMENDATIONS. SWITCHING,UON. • AEMERGENCY LUMINAIRE - SHADED PROVIDE WITH INTEGRAL BATTERY BACKUP EPO EMERGENCY POWER OFF II. ALL CUTTING, DRILLING AND PATCHING OF MASONRY,STEEL OR IRON WORK BELONGING TO THE BUILDING 34. UNLESS OTHERWISE NOTED,LUMINAIRES DESIGNATED AS NIGHT LIGHT(NL) SHALL BE CONNECTED AHEAD OF I. MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT HIS WORK MAY BE PROPERLY INSTALLED,BUT UNDER LOCAL SWITCHING AND REMAIN ON 24 HOURS A DAY. Ln KO PORCELAIN LAMP HOLDER ENG ELECTRIC HATER COOLER NO CONDITIONS MAY STRUCTURAL WORK BE GUT,EXCEPT AT THE DIRECTION OF THE ARCHITECT-DESIGNER FIRE ALARMOR THEIR REPRESENTATIVE. 35. WHERE DUAL LEVEL SWITCHING IS INDICATED, THE SWITCH CLOSEST TO THE DOOR SHALL CONTROL ALLLO (R) EXISTING TO BE REMOVED OUTER LAMPS IN THE INDICATED LUMINAIRE AND THE ADJACENT SWITCH SHALL CONTROL ALL INNER e STEP LIGHT TYPE LUMINAIRE 12. E.G. IS TO REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ALL FIRE RATED PENETRATION LAMP(S) IN THE INDICATED LUMINAIRES,UON. 00 ® FIRE ALARM CONTROL PANEL F FUSE INSTALLATION REQUIREMENTS. E.G. IS TO NOTIFY ENGINEER AND ARCHITECT PRIOR TO INSTALLING ANY �� BOLLARD OR POST TOP LUMINAIRE FIXTURES WITHIN A FIRE RATED CEILING OR HALL. FIRE RATING MUST BE MAINTAINED FOR THIS TYPE OF 36. PROVIDE OWNER WITH A COMPLETE LISTING OF ALL LAMPS UTILIZED ON THE PROJECT INCLUDING 0 �� FLA FULL LOAD AMPS INSTALLATION WITH DRYWALL TENTING. ® FIRE ALARM ANNUNCIATOR/GRAPHIC MAP MANUFACTURER AND CATALOG INFORMATION. PROVIDE A SUGGESTED SOURCE, INCLUDING CONTACT NAME 0-E EXTERIOR AREA LIGHT FD GARBAGE DISPOSAL AND PHONE NUMBER,FOR REORDERING. U 13. E.G. SHALL PROVIDE COORDINATION STUDY OF NEW AND/OR NEW GEAR COMBINED WITH EXISTING GEAR CIMNM FIRE ALARM REMOTE POWER SUPPLY DURING THE SUBMITTAL PROCESS. 31. THE CONTRACTOR SHALL VERIFY THE CEILING TYPE BEFORE ORDERING LIGHTING FIXTURES. W Ce G GROUND ca CONTROL MODULE GC GENERAL CONTRACTOR 14. SHOP DRAWINGS SHALL INCLUDE MANUFACTURERS NAMES,CATALOG NUMBERS,CUTS,DIAGRAMS AND 38. ROUGH IN FOR MECHANICAL EQUIPMENT SHALL ONLY OCCUR AFTER MECHANICAL EQUIPMENT SUBMITTALS 0 OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. ARE THOROUGHLY REVIEWED FOR CHANGES. NOTIFY ENGINEER OF ANY DISCREPANCIES. FI GROUND FAULT CIRCUIT INTERRUPTER SUBMITTALS SHALL BE IN LOGICAL GROUPS,FOR EXAMPLE,ALL LIGHTING FIXTURES,PARTIAL SUBMITTALS MONITOR MODULE WGFI DEVICESHILL NOT BE REVIEWED. 3qV. FINAL LAYOUT AND QUANTITY OF ALL FIRE ALARM DEVICES SUBJECT TO APPROVAL OF LOCAL AUTHORITY > ® HP HORSEPONER HAVING JURISDICTION. Q MANUAL PULLDOWN STATION 15. SUBMIT(3) COPIES OF THE FOLLOWING SHOP DRAWINGS FOR REVIEW. D LU W 0 DUPLEX RECEPTACLE IDF INTERMEDIATE DISTRIBUTION FAG ILITY A. SWITCH BOARD,PANELBOARDS,AND METERING EQUIPMENT 40. COORDINATE ELECTRIC WATER COOLER RECEPTACLE PLACEMENT SUCH THAT THE RECEPTACLE IS 1 1 > HALL MOUNTED ADA STROBE B. DISCONNECTS ACCESSIBLE,YET CONCEALED BY COOLER,REGEPTAGLE TO BE GFGI TYPE. �J 4 FOUR FLEX RECEPTACLE IG ISOLATED GROUND G. FIRE ALARM SYSTEM J Fe DOD. LIGHT FIXTURES 41. THE POWER AND CONTROL REQUIREMENTS FOR ALL EQUIPMENT CONNECTIONS SHALL BE CONFIRMED WITH Q ❑ ADA HORN OR SPEAKER WITH STROBE TSC SHORT CIRCUIT CURRENT E. LIGHTING CONTROLS APPROVED SHOP DRAWINGS PRIOR TO ELECTRICAL ROUGH-IN. FINAL POWER REQUIREMENTS, DIMENSIONED J SINGLE RECEPTACLE F. TRANSFORMERS ROUGH-IN LOCATIONS,LOW VOLTAGE SYSTEM CONNECTIONS,ETC. SHALL BE CONFIRMED AND MODIFIED AS ❑t MINI HORN / STROBE KVA KILOVOLT AMPERE(S) G. PROVIDE "AS-BUILT" DRAWINGS AND SUBMIT TO ARCHITECT/DESIGNER. REQUIRED. O > COMBO RECEPTACLE/SWITCH W KW KILOWATTS) 16. ALL MATERIAL,EQUIPMENT,WIRING DEVICES,ETC. SHALL BE NEW,UNLESS SPECIFICALLY INDICATED AS 42. ALL DEVICES IN OR ABOVE COUNTERS SHALL HAVE LOCATIONS AND MOUNTING HEIGHTS CONFIRMED WITH ELECTROMAGNETIC DOOR HOLD OPEN SWITCHED DUPLEX RECEPTACLE J .M1-1 ELECTROMAGNETIC TO BE REUSED. ARCHITECTURAL ELEVATIONS it OWNER PRIOR TO ROUGH-IN. ANY ADJUSTMENTS TO MOUNTING HEIGHTS w 1 LTG LIGHTING REQUIRED BY LACK OF COORDINATION WILL BE AT THE CONTRACTORS EXPENSE. U47t ® SPRINKLER FLOW SWITCH I7. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY DRAWINGS AND REQUIREMENTS. U 10 SPECIAL PURPOSE RECEPTACLE MGA MINIMUM CIRCUIT AMPERE(S) ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE ELECTRICAL 43. ALL EXISTING ELECTRICAL SERVICES NOT SPECIFICALLY INDICATED TO BE REMOVED OR ALTERED SHALL ® SPRINKLER TAMPER SWITCH UTILITY COMPANY WITHIN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THE REVIEW, REMAIN AS THEY PRESENTLY EXIST. W FLOOR MOUNTED SPECIAL PURPOSE MGB MAIN CIRCUIT BREAKER APPROVAL,ALL ASSOCIATED DOWN TIME,CONSTRUCTION SCHEDULING, DELIVERY,AND INSTALLATION OF ce •T THERMAL DETECTOR RECEPTACLE MDP MAIN DISTRIBUTION CENTER THE UTILITY TRANSFORMER. NOTIFY OWNER OF SCHEDULING CONFLICTS. 44. G.G. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES,CONDUITS, O FIXTURES AND EQUIPMENT. TURN EQUIPMENT OVER TO OWNER AS INDICATED OR REGYGLE/DISGARD ALL ® FLOOR MOUNTED RECEPTACLE DUPLEX/QUAD MDF MAIN DISTRIBUTION FACILITY 18. ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL MATCH EXISTING BUILDING EQUIPMENT AS REQUIRED. E.G. SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND ❑ •S PHOTOELECTRIC SMOKE DETECTOR ® PANELBOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR SHALL PROVIDE NEW TYPE WRITTEN TEMPORARY POWER. MLO MAIN LUGS ONLY PANEL DIRECTORIES FOR ALL NEW PANELS AND EXISTING PANELS WHICH HAVE CHANGED. PANELBOARD DUCT SMOKE DETECTOR, SUPPLY OR RETURN 5R SURFACE RACEWAY SHALL BE MARKED WHERE THE SOURCE OF POWER SUPPLY ORIGINATES, AND IF SERIES COMBINATION 45. WHERE EXISTING CEILINGS ARE REVISED FROM ACCESSIBLE TO NON-ACCESSIBLE,CONTRACTOR IS TO Ln SYSTEMS ARE UTILIZED AND THEIR LISTED AMPERE RATING. INCLUDE IN HIS BID THE COSTS ASSOCIATED WITH RELOCATING ALL ELECTRICAL EQUIPMENT REQUIRING CLOCK RECEPTACLE MTS MANUAL TRANSFER SNITCH ACCESS ABOVE THE EXISTING CEILING TO A NEW ACCESSIBLE CEILING LOCATION APPROVED BY LO O REMOTE INDICATING LIGHT (TEST SWITCH) I . DO NOT SHARE NEUTRAL CONDUCTORS FOR MULTIWIRE BRANCH CIRCUITS. WHERE THE E.G. PROPOSES THE ARCHITECT AND ENGINEER. THE USE OF ACCESS PANELS IN THE NEW CEILING TO AVOID RELOCATION OF N i QTS MN MICROWAVE USE OF SHARED NEUTRAL CONDUCTORS OR SHARED NEUTRAL CONDUCTORS ARE REQUIRED (SUCH AS THIS EQUIPMENT IS NOT ACCEPTABLE. O 12OV. MOTORIZED SMOKE DAMPER 0 JUNCTION BOX NG NORMALLY CLOSED POWERED FURNITURE SYSTEMS),HANDLE TIES SHALL BE PROVIDED ON THE CIRCUIT BREAKERS,WITH J HALL MOUNTED J-BOX SHARED NEUTRALS,SUCH THAT IT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS. ALL V� RESCUE ASSISTANGE PHONENL NIGHT LIGHT - SEE GENERAL NOTES HANDLE TIES ARE REQUIRED TO BE INDICATED ON THE PANELBOARD SHOP DRAWINGS. FIRE FIGHTERS PHONE JACK • FLOOR MOUNTED JUNCTION BOX NO NORMALLY OPEN 20. SHOULD ACTUAL FIELD CONDITIONS REQUIRE INDICATED CIRCUIT DESIGNATIONS TO VARY, INDICATE THE �F CIRCUIT NUMBER USED ON THE "AS-BUILT" DRAWINGS. � MOLDED CASE GIRGUIT BREAKER IN OAE OR APPROVED EQUAL � e e ENCLOSURE OH OVERHEAD 21. ALL SERVICE EQUIPMENT(OTHER THAN IN DWELLING UNITS) SHALL BE LEGIBLY MARKED IN THE FIELD BY THE ELECTRICAL CONTRACTOR WITH THE MAXIMUM AVAILABLE FAULT CURRENT AS INDICATED WITHIN THESE DOCUMENTS. THE FIELD MARKING(S) SHALL COMPLY WITH ELECTRICAL SPECIFICATIONS FOR •71- 0-1 NON-FUSED DISCONNECT SWITCH P POLE READABILITY AND DURABILITY. H • PART PARTIAL CIRCUIT Q rn Ell FUSED DISCONNECT SWITCH 22. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING THROUGHOUT THE in PH, 4) PHASE EXTENT OF THE REQUIRED DISTRIBUTION SYSTEM. LO Z MAGNETIC CONTROLLER (STARTER) A. UTILIZE RIGID POLYVINYL CHLORIDE CONDUIT(PVC) IN THE FOLLOWING LOCATIONS: PNL PANEL a. UNDERGROUND EH COMBINATION STARTER/D15GONNEGT SWITCH B. UTILIZE ELECTRICAL METALLIC TUBING (EMT),MINIMUM SIZE OF 3/4", IN THE FOLLOWING LOCATIONS: z I� RCPT RECEPTACLE a. SERVICE AND FEEDERS Z 0 b. POWER CIRCUIT HOMERUN _0 17 HP MOTOR REF REFRIGERATOR c. BRANCH CIRCUITS IN CONCEALED OR EXPOSED LOCATIONS � Q d. TELEPHONE/DATA/CATV ROUGH-IN d Z O RELAY (RL) RELOCATED G. UTILIZE METAL-CLAD GABLE (MC) IN THE FOLLOWING LOCATIONS: p a. BRANCH CIRCUIT IN CONCEALED LOCATIONS U SPD SURGE PROTECTION DEVICE b. FINAL CONNECTION TO RECESSED LIGHTING FIXTURES w 0 1=I TIME CLOCK c. FINAL CONNECTION TO STEP-DOWN TRANSFORMERS 0 0 UC UNDER GOUNTER/CABINET V O PHOTOCELL UG UNDERGROUND THERMAL OVERLOAD SWITCH TYPICAL ci'-O" CEILING c 6 w , Irk 4To UON UNLESS OTHERWISE NOTED B "i $ SINGLE POLE SWITCH V VOLT(S) cc `� H wATT(s) OR HIRE NOTES: TYPICAL 8'-0" CEILING N $3 3-WAY SWITCHI. WHERE MULTIPLE LINE VOLTAGE DEVICES ARE SHOWN ADJACENT TO B o 0 0 ,- HG HIRE GUARD EACH OTHER, THEY ARE ALL TO SHARE THE SAME JUNCTION BOX, UP °O "' oN $4 4-WAY SWITCH TO FOUR GANGS. TO BOTTOM OF DEVICE (SEE NOTE 4) © n _II 1O Q o HP WEATHERPROOF N o > K KEY OPERATED SWITCH XFRM TRANSFORMER 2. WHERE MORE THAN FOUR DEVICES ARE SHOWN ADJACENT TO EACH Z OTHER, DEVICES ARE TO STACK VERTICALLY ABOVE ONE ANOTHER TOP OF GAB INET = ~ 3 SD DIMMER SWITCH IN TWO ROWS IN AS SMALL OF GANG BOXES AS POSSIBLE. I.E. SIX POWER PANEL, FIRE ALARM 2 Ox POOL EQUIPMENT SCHEDULE NOTATION DEVICES HILL USE TWO THREE GANG BOXES, FIVE DEVICES WILL USE PANEL OR MASTER CLOCK a $DOOR RECESSED DOOR SWITCH ONE THREE GANG AND ONE TWO GANG BOX. CENTER OF GABINET REMOTE FIRE ALARM cr' HS(x) LIGHTING CONTROL SYSTEM LOW VOLTAGE O KITCHEN EQUIPMENT SCHEDULE NOTATION 3. SEPARATELY GANGED DEVICES ARE NOT ALLOWED TO BE ANNUNCIATOR H Z x tt 121 DIGITAL HALL STATION. (X) INDIGATES INSTALLED ADJACENT TO ONE ANOTHER HORIZONTALLY WITHIN THE TO CENTER t ¢ N N V INDIVIDUAL HALL STATION ADDRESS. REFER 0 SAME STUD BAY. 0 o u - - o TO LIGHTING CONTROL ONELINE DRAWING. MECHANICAL EQUIPMENT SCHEDULE NOTATION N 4. AUD IBLE/VISUAL FIRE ALARM DEVICES SHOWN ARE TO BE MOUNTED Copyright©2010-All rights reserved W QS SINGLE RELAY OCCUPANCY SENSOR. Ox DETAIL NOTE AT c10" OR 6" BELOW GEILINO, WHICHEVER 15 LOWER. ADA STROBES g'-0" TO CENTER ❑' Q . ) -w O , I, TO TOP MOST G.B. OF Architectural Engineering Design Group,Inc. TO BE MOUNTED AT SO" AFF OR 6" BELOW GEILINO, WHICHEVER IS 'ADA' ACCESSIBLE / herAll design drawings and written material 1 os DOUBLE RELAY OCCUPANCY SENSOR. 11-4 the written may conet t of rcoiduplicatedtlwithout o ❑D /� LOWER. TO CENTER W x DELTA REVISION NOTE _ r vvi ADAPTABLE RESIDENTIAL the consent of Architectural (I,v II UNIT LOAD CENTERS. Engineering design Group,Inc. �' QG CEILING MOUNTED OCCUPANCY SENSOR. 5. ALL ELECTRICAL BOXES INSTALLED IN A WALL OR CEILING WITH A 6,-5" ADA STANDARD ABOVE 1 W © ELECTRIGAL WIRE SIZE MINIMUM I-HOUR FIRE-RESISTANCE RATING SHALL BE WRAPPED WITH 6'-0" COUNTER DEVICE AT 42 , AN INTUMESCENT MOLDABLE FIRESTOP PUTTY PAD DESIGNED TO 5'-4" OR ci" ABOVE COUNTER o HELP PROTECT ELECTRICAL OUTLET BOXES. INSTALL PER 5'-0" TO CENTER OF DEVIGE, E MANUFACTURERS LITERATURE. WHICHEVER IS HIGHER eE 6. ALL ELECTRICAL BOXES INSTALLED ON OPPOSITE SIDES OF A 4'-0" y COMMON HALL, LESS THAN 24" HORIZONTAL SPACING, SHALL BE 3'-6" L.o INSTALLED WITH A LAYER OF EXPANDABLE SPRAY FOAM INSULATION v0 Q c.) AROUND EACH ELECTRICAL BOX. TO CENTER op 1 o J oziI'-6" Q rN I 1 N I U ► ► ► ► 1 ► � , ^/ ce U w w > 1 DEVICE MOUNTING HEIGHT DIAGRAM F J O w w '� E1.0 SCALE: NONE Lu U (r) O a .cSHEET NO. 113 'I) a� .c a E 1 . 0 U V) ;w, .._U C.) Q